Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM 603 102 KANCHEEPURAM DIST | KALPAKKAM | KANCHEEPURAM | TAMIL NADU | 603102 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹5.2 L+₹31,790 (6.51%)Rejected-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹6.0 L+₹1.1 L (23.2%)Rejected-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹6.3 L+₹1.4 L (28.4%)Rejected-AOC NO 03 45 NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM CHENGALPATTU DISTRICT 603 102 | KALPAKKAM | CHENGALPATTU | TAMIL NADU | 603102 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹6.4 L+₹1.5 L (30.5%)Rejected-AOC NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹6.8 L
EMD Value
₹13,600
Closing Date
16 Mar 2022, 6:00 pmClosed
AGE(I) Navy Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
REPAIR/ REPLACEMENT OF UNSERVICEABLE UG CABLE, MCCB ETC AND REPAIR/ REPLACEMENT OF STREET LIGHTS, UNSERVICEABLE CABLES AT KALPAKKAM
2022_MES_508575_1
AGE(I)/NAVY/CHN/8291 of 2021 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹13,600
Yes
22 Apr 2022
16 Feb 2022
17 Mar 2022
16 Feb 2022
16 Mar 2022
2 Mar 2022
17 Feb 2022 - 23 Feb 2022
Amount
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtr deep in hard /dense soil for laying underground cables, laying pipes etc. complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and lay fine sand cushion in trenches for cable protection, spreading, levelling, Punning and consolidating complete all as specified.
Supply and laying un re-inforced precast concrete cable cover, class LV, type-I flat, size 250 mmx150 mmx40 mm in trenches over and across the cable complete all as specified.
Taking down old unserviceable old damaged GI pipe and S&F new GI pipe light grade of size 40mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
Taking down old unserviceable old damaged GI pipe and S&F new GI pipe light grade of size 50mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
Supply and lay in trenches, fixed to wall / pole/ tray etc UG cable XLPE insulated armoured heavy duty electric UG cable of cross sectional area of size 4 Core 16 Sqmm with aluminum conductor 1100 volts grade all as specified and as directed.
All as per Sl item No. 08 above but of size 2 core 16 Sqmm
All as per Sl item No. 08 above but of size 3.5 Core 25 Sqmm
All as per Sl item No. 08 above but of size 3.5 Core 50 Sqmm
All as per Sl item No. 08 above but of size 3.5 Core 70 Sqmm
All as per Sl item No. 08 above but of size 3.5 Core 150 Sqmm
All as per Sl item No. 08 above but of size 4 Core 10 Sqmm
Disconnecting taking out from trenches / pole out lived LT UG cable of size as mentioned under Item No.08 to 14 above and taking old unserviceable LT UG into credit complete all as specified and as directed by the Engineer-in-Charge complete. Note : Excavation and earth work will be measured and paid separately.
M&L for providing earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron earth strip size 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for providing earthing complete with copper plate electrode 600 mm x 600 mm x3.15mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to Copper earth strip 20x3mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 3of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( NOTE :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ).all as directed by Engineer- in charge.
Test point terminal box made out of Gun metal or Phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screws including taking down old unserviceable test point terminal box for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
S&F in repair MCCB four pole 415 volts, 50 Hz, 25 to 100 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
S&F in repair MCCB four pole 415 volts 50 Hz , 160 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
S&F in repair MCCB four pole 415 volts, 50 Hz , 250 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
S&F Metal Box size 200 X140 X95 mm internal size with hinged door(L) with 1 No PVC connector 4 way 16 Amps and 1 Nos MCB SP 6 Amps including fixing bracket,Nut,Bolts etc complete Make : Sintex Cat part No GSJB2014 or Equvalent of National.
S&F Post top Lantern Light 30 W Fitting with high luminuos efficiancy IP 65 Protected with front toughened glass of capacity with impact and corrosion resistant including all accessories and wiring including dismantiling of old unserviceable fitting Make : C&S Model No LGLC30WHPLED/WF150WHPLED or equivalent to Surya/Bajaj/Philips/Havells
S&F Double Door Vertical TPN Distribution Box 4 way complete in SS enclosure with 200 amps rated busbar.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of poles SP 6 to 32 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of poles TPN 40 to 100 Amp and current carrying capacity in the DB complete with connection testing and commissioning
S&F Cable with copper conductor PVC round sheathed (flexible) industrial cable 2.5 sqmm
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type.
All as per Sl item No. 28 above but of size 3 ½ / 4 core 70/150 sqmm
M&L for painting the Panel boards/DB Boxes/covers/DG Set/Accoustic Enclosures as required at site after scraping out completely the old paint with one coat of redoxide primer and two coats of synthetic enammel paint including carrying out minor welding works if reqired as directed by the Engineer in charge NOTE:Colour of paint shall be decided by the Engineer-in-charge.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply only LED driver for 45 watt LED street light fitting complete all as specified and directed.
Supply only LED Surge Arrester(SRPS 5K 440) for 45 watt LED street light fitting complete all as specified and directed.
EVEREST ENGINEERING WORKS
Green Ray Enterprises
S Dilli
SRI LAKSHMI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .