Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹79.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹2+₹1 (100.0%)Rejected-Finance 5 MATHURA ROAD JANGPURA A NEW DELHI DELHI 110014 | SOUTH EAST DELHI | DELHI | 110014 | 2 | Rejected-Finance NOT L1 | |
| 3 | 3₹3+₹2 (200.0%)Rejected-Finance 3 C 301 320 SOLARIS 1 SAKI VIHAR ANDHERI POWAI MAHARASHTRA 400072 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | 3 | Rejected-Finance NOT L1 | |
| 4 | Rejected-Technical 104 A SYNTHOFINE ESTATE OFF AAREY ROAD GOREGAON EAST MUMBAI MAHARASHTRA 400063 | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | - | Rejected-Technical techno-commercially not accetable | |
| 5 | Rejected-Technical OFFICE NO 301 302 MEGACNETRE PUNE SOLAPUR ROAD HADAPSAR PUNE MAHARASHTRA 411028 | PUNE | MAHARASHTRA | 411028 | - | Rejected-Technical techno-commercially not accetable |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
31 Oct 2019, 1:00 pmClosed
SANDEEP SONAVALE
RCF THAL
IP BASED CCTV SURVEILLANCE SYSTEM
2019_RCFL_509641_1
AL-64121 IP BASED CCTV SURVEILLANCE SYSTEM
Open Tender
Miscellaneous Goods
Supply
120 days
RCF THAL
AS PER NIT
5 documents required · 5 mandatory
₹0
₹50,000
Yes
29 Jan 2020
9 Oct 2019
31 Oct 2019
9 Oct 2019
31 Oct 2019
9 Oct 2019
SUPPLY OF ITEMS AS PER FOLLOWING SPECIFICATIONS
MEGAPIXEL HD 2 MPX IP BASED PTZ DOME OUTDOOR CAMERA & ACCESSORIES as per tender specifications.
MEGAPIXEL HD 2MPX IP BASED BULLET CAMERA OUTDOOR CAMERA & ACCESSORIES as per tender specifications.
Network Video Server with keyboard, mouse, monitor, 140 TB HDD storage hardware & required software, with its accessories as per tender specifications.
Video Management Software with license for 75 cameras recording, viewing and playback capability as per tender specifications.
Client Work Station with keyboard, mouse, monitor, 2 TB HDD storage hardware & required software, for Viewing with its accessories as per tender specifications.
65" LED PROFESSIONAL SERIES 24/7 Operation HD MONITOR as per tender specifications.
24+4 PORT ETHERNET SWITCH CISCO 3850 24S with its accessories as per tender specifications.
8+2 PORT INDUSTRIAL GRADE ETHERNET POE SWITCH with its accessories as per tender specifications.
JUNCTION BOX (JB) IP65 with its accessories as per tender specifications.
42U X 800MM W X 1000MM D RACK for NVR Server with its accessories as per tender specifications.
CAT 6 ETHERNET cable Suitable for Outdoor Installations as per tender specifications.
POWER CABLE 2.5 Sq MM 3 Core Wire armoured power cable with necessary termination & laying as per tender specifications.
12 Core Single Mode Outdoor Fiber Optic Cable Of 9/125 Micron Specification.
1U Rack Mount 24 Port Fiber Distribution Unit (LIU) With Adapter Strip & Couplers, Splice tray.
SC Pigtail Single Mode 9/125
LC-SC & SC-SC Single Mode Duplex Fiber Patch Cord Of 3 Meter Each
1" PVC Conduit ISI Mark with accessories like T-joint, couplers, Aluminium Clip etc. for fixing OFC & Power Cable
Supply of SS Plate 7"x7" 4MM Thickness Grade 304 for Camera Mounting
Supply of SS Pipe 2" Dia Grade 304 with Bend/Elbow/Coupler etc. for Camera Mounting
Heavy Duty 150 mmX150 mmX80mm SS Box Grade 304 Required for mounting of each camera on wall, IP66, Make Ritall or Equivallant of CE/FCC/UL Certified, for Camera Cables Connections.
Optical Fiber Cable Pulling & Laying in GI/HDPE/PVC Conduit on Cable rack/Wall Fixing
Power Cable Pulling & Laying in PVC Conduit on cable rack/Wall Fixing
UTP Cabling in PVC Conduit on Wall/Rack/Fixing
Splicing Of Single Mode Optical Fiber Cable
Fabrication of Mounting Stand/Bracket/Wall mount Arrangement Cutting, Welding & Drilling of SS Pipe/Plate as per RCF Requirement for Installation of Bullet/PTZ Camera on Wall/Roof
Installation, Testing & Commissioning of the system. Laying & Termination of Power, OFC and UTP Cables, Installation of Pole, JB & Camera Mounting on Poles/Structure/Wall with required fabrication etc. SS Nut/Bolt of All Size as per site requirement for Mounting of Cameras and JBs. Anchor fastener of required size. Required 1" PVC Flexible Pipe 300 Meters. Required Two Pole MCB 6/10/16 Amp 20 Nos, TOP 5/15 Amp 12 Nos. Required lugs for Power Cable termination etc. PVC Gland any size required. Shielded RJ45 Connector for CAT6 300 Nos. Insulation tape Black 50 Nos. Cable tie required. DIN Rail. Any other required Job for successful Completion of CCTV System.
1st YEAR COMPREHENSIVE AMC
2nd YEAR COMPREHENSIVE AMC
3rd Year COMPREHENSIVE AMC
4th year COMPREHENSIVE AMC
5th Year COMPREHENSIVE AMC
Twenty four systems Pvt. Ltd.
UNICOM INFOTEL PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .