Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC 29 KESHULI AKOUR MADHUBANI MADHUBANI BIHAR 847230 UDYAM BR 20 0037592 | MADHUBANI | BIHAR | 847230 | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | L2₹21.9 L+₹22,782.70 (1.05%)Rejected-Finance H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹22.0 L+₹34,048.60 (1.57%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
13 Aug 2022, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Provn of store room for TRU and parking shed at TMQ at AF Stn Darbhanga under GE (AF) Bihta
2022_MES_516430_4
8213/BHT/DBG/E8
Open Tender
Civil Works
Item Rate
180 days
Darbhanga
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹50,000
Yes
23 Sept 2022
20 Jul 2022
15 Aug 2022
20 Jul 2022
13 Aug 2022
29 Jul 2022
Amount
Surface excavation n exc 30cm deep and averaging 15cm and getting out in Soft/ loose soil complete all as specified and as directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m deep and getting out in soft/ loose soil omplete all as specified and as directed.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in foundation concrete, filling and mass concrete complete all as specified and as directed.
M&L for brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for MS TMT bars 8mm dia and over cut to length, bent to shape required, including cranking, bending,spirally for hoping for columns, hooking end and binding with and incl mild steel wire (annealead) not less than 0.9mm dia, complete all as specified and directed.
Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spaces and binders complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed aggregate) mixed with water proofing compound as in DPC course complete all as specified and as directed.
Supply only Liquid water proofing compound.
M&L for RCC Nominal Mix 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers lintels over 1.5m span, complete all as specified and as directed.
Use and waste of formwork to sides and soffits of, bressummers lintels, rough finished complete all as specified and as directed.
M&L for RCC as in slab supported on columns, beams, walls etc in roofs, landing etc and like Type B 1 (1:2:4) (using 20mm garded stone aggregate) Nominal Mix, complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping), incl fair finish surface complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide, complete all as specified and as directed.
M&L 15mm thick rendering on fair faces of brick masonary or concret surfaces in cm 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M & L Rendering 15mm thick on other than fair faces on brick masonary or concrete surfaces in cm 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L prepration of newly plastered external surface of wall and applying two coat of cement base paint over a coat of chalk whiting complete all as specified and as directed.
M&L for Prepration of newly plastered surface of walls and applying three coat of white washing, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, waterning and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated material n,exc 50 m and depositing where directed at a level n, exc 1.5m above the starting point complete all as specified and as directed.
M&L steel work in tubular trusses /posts including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 -1979 graded SI 240, complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed.
M&L for hard core (broken bricks) of gauze n exc 63mm deposited, spread in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L 100 thick PCC 1:3:6 type B2 (using 40mm graded stone aggregates) as in base course to floor finish, hardstanding, sub base etc complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) finished surface even & smooth without using extra cement as in plinth protection complete all as specified and as directed.
M&L for 40mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in floor finished even and smooth using extra cement complete all as specified and as directed.
S&F glass dividing strip 38mm wide and 3mm thick and inserted to certain design all as specified and as directed.
M&L 2nd class H/wood chowkhats, plain, solid, straight, wrought, framed, rebate on the solid,rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F 30 mm thick flush shutter , solid core construction ,with block board core and plywood face panel ,commercial type on both side complete all as specified and as directed.
M&L for Hold fast for fixing of chowkats and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and as directed.
S&F mild steel medium weight cold rolled butt hinges 100 mm long complete all as specified and as directed.
S&F aluminium anodised, barrel tower bolt of extruded section 150mm long complete all as specified and as directed.
S&F 125 mm long aluminium handle, cast type, anodised complete all as specified and as directed.
S&F aluminium alloy anodised sliding door bolt with hasp staple (bolt type), 250 mm long,and fixing clip of sheet cast or extruded section or fixing bolt cast aluminium alloy and fixed complete all as specified and as directed.
M&L applying two coats of synthetic enameled painting over a coat of pink primer to new wooden surfaces of any description exc 10 cm width or girth including prepration of surface complete all as specified and as directed..
M&L Preparing Surfaces treating small articles such as stop, gully grating, holdfasts ends of posts backs backs of chowkats etc, area tarred n.exc 0.1 sqm each complete all as specified and as directed.
S&F steel window side hung shutters including projecting type hinges with steel handle and steel pegs stay complete with glazing bars complete all as specified and as directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
S/F 3mm thick ordinary quality sheet glass in squares n.exc 0.5 sqm in each pane glazing with oil putty complete all as specified and as directed.
M&L for window guard bars, plain let in and fixed independently in wooden frames L or T section support for shelves etc., and similar articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
S&F Steel rolling shutters, Thickness of laths in 1 mm with ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indi?cated, complete: push pull or manual type incl Safety lever locks mild steel with 4 levers complete all as specified and as directed.
M & L for preparation of new steel surfaces and applying 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer primer, complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 5 cm but n exc 10 cm wide, complete all as specified and as directed.
Use and waste of formwork to sides and soffits of, bressummers lintels, rough finished complete all as specified and as directed.
Forming contraction (dummy) joints 50mm deep x 10mm wide filled with sealing compound grade 'B' complete all as specified and directed.
Material and labour for point wiring for One light point with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, ISI marked, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, ISI marked, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed. (a)One light or fan point controlled by one way switch
(b) 3pin 5 Amp socket outlet on independent board complete all as specified and directed.
(c) 3 Pin 5 Amp socket outlet on same board complete all as specified and directed.
S & F Switch Piano, flish button, single pole one way, 5 Amp,230 Volts complete all as specified and directed.
S & F socket flush type 5 pin 5 Amps shutter complete all as specified and directed.
S & F ceiling rose surface bakellite of three terminals complete all as specified and directed.
S & F Sheet metal enclosre for MCB DB SPN double door 4 way 240 Volts with 200 Amps rated bus/bars complete all as specified and directed. Make:-.Havells/Legrand/Hager
S & F MCB SPN 63 Amp ISI marked convient to 'C' Curve breaking capacity 10 KA complete all as specified and directed. Make:-Havells/Legrand/Hager
S & F MCB Single pole 240 Volts 6-32 Amp ISI marked convienent to 'C' Curve breaking capacity 10KA complete all as specified and directed. Make-Havells/Legrand/Hager
Supply and laying & testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 25 Sq mm 2 core including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. Make:- Nicco/Plaza/Gloster/Havells/polycab.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified and directed.
M&L for sand cushioning for cable with river washed sand and pinning to provide required cover as per SSR Part –I complete all as specified and directed.
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., complete all as specified and directed:- (a) 40 mm bore dia
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ complete all as specified and directed.
S & F LED building security Light fitting complete 70 Watt with high power energy saving pressure die cast aluminium IP 66 roadway luminiarys heat resistant toughened glass with frame better optics for uniform distribution with high power LED as Ligh source including with the help of GI pipe(medium grade) and bracket ,etc complete all as specified and directed. Make - Crompton Cat Pat No LSTP-70-CDL or equivelent make and model of PHILIPS/Havells
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 4.0 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade, ISI marked complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing surface complete all as specified & directed.
Supply & fixingin repair of decorative batten type fittings with E-Lite LED Quadra Glow decorative fitting. 4 step dimming with a click of switch from 22W complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:/HAVELLS or eqv in Crompton/Philips
S&F Ceiling fan regulator electronic step type.Make-Anchor complete all as specified and directed.
Supply and fixing Ceiling fan of 1200 mm sweep,230V,350-370 RPM,with air delivery of 215 cmm or more with BEE 5 star rated including provn of fan hook made of MS of required size and shape,hanging with the help of down rod upto 04 feet and connecting with provn of 3 core copper cable of size 1.5 sqmm from ceiling rose to fan complete all as directe dwith all aceesories complete all as specified and directed. Make-Havells/Crompton/Usha
SHIV SHAKTI TRADERS
PAPPU ROY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .