Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹700Admitted-Finance | ₹700 | L1 | Admitted-Finance |
| 2 | L2₹4,252.16+₹3,552.16 (507.5%)Admitted-Finance | ₹4,252.16+₹3,552.16 (507.5%) | L2 | Admitted-Finance |
| 3 | L3₹29,772+₹29,072 (4153.1%)Admitted-Finance | ₹29,772+₹29,072 (4153.1%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical ACCORDING TO CONDITION 1 OF THE TECHNICAL BID |
| 5 | Rejected-Technical 1241 4TH FLOOR SOLITAIRE CORPORATE PARK BUILDING NUMBER 12 ANDHERI GHATKOPAR LINK ROAD ANDHERI EAST | - | - | Rejected-Technical ACCORDING TO CONDITION 1 OF THE TECHNICAL BID |
| Sl No | Description | Qty | Unit | Maxwell Scientific Store L2 | KOGTA MEDICAL STORE L1 | M.G. DISTRIBUTORS L3 |
|---|---|---|---|---|---|---|
| 1.00ANGIOGRAPHY ITEMS | ||||||
| 1.01 | FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 9Fr.) (standard Length)
• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French.
• 10-11 cm Long
• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire
• With haemostatic valve to prevent back leak and air aspiration
• Integral side port with attached 3-way stopcock
• With suture eye for securing sheath
• Kink resistant
• With dilator-hub lock mechanism to prevent its back- out during insertion
• With smooth and resistance free insertion | 1 | Nos | - | - | - |
| 1.02 | Radial glide sheath INTRODUCER
SHEATH with outer diameter one Fr size Under. (6 Fr sheath with outer diameter of 5 Fr)
• Size 5 French/ 6 French/ 7 French
• Sheath should be between 10-20 cm long
• 0.021 and 0.025 inch guide wire compatible
• Hydrophilic Coating
• 20-22 G needle length 2’ inch
• Guide Wire Should be available in 3 forms A.) Plastic Short Angle
B) Flex Straight
C) Nitinol Floppy
• With haemostatic valve to prevent back leak and air aspiration
• Integral side port with attached 3-way stopcock
• With suture eye for securing sheath
• Kink resistant
• With dilator-hub lock mechanism to prevent its back-out during insertion
• With smooth and resistance free insertion | 1 | Nos | - | - | - |
| 1.03 | LONG INTRODUCER SHEATH (20-50 cm long) (size 4Fr. -11Fr.)
• Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 French
• Sheath should be between 20-50 cm long
• 0.035 or 0.038 inch guide wire and compatibility
• With haemostatic valve to prevent back leak and air aspiration
• Integral side port with attached 3-way stopcock
• With suture eye for securing sheath
• Kink resistant
• With dilator-hub lock mechanism to prevent its back-out during insertion
• With smooth and resistance free insertion | 1 | Nos | - | - | - |
| 1.04 | TRANS RADIAL INTRODUCER SHEATHS 4F-6F-
• Size 4 French/ 5 French/ 6 French
• 07-10 cm long
• Guide Wire Should be available in 3 forms A.) Plastic Short Angle
B) Flex Straight
C) Nitinol Floppy
• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches
• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibility
• With haemostatic valve to prevent back leak and air aspiration
• Integral side port with attached 3-way stopcock
• With suture eye for securing sheath
• Kink resistant
• With Dilator hub-lock mechanism to prevent its back-out during insertion
• With smooth and resistance free insertion | 1 | Nos | - | - | - |
| 1.05 | LONG BRAIDED INTRODUCER SHEATH-
• Size 6 French/ 7 French/ 8 French/ 9 French and above
• Should be 30-90 cm and above
• 0.021 or 0.025 inch guide wire compatible
• With haemostatic valve to prevent back leak and air aspiration
• Integral side port with attached 3-way stopcock
• With suture eye for securing sheath
• Kink resistant
• With dilator-hub lock mechanism to prevent its back-out during insertion | 1 | Nos | - | - | - |
| 1.06 | PTFE COATED DIAGNOSTIC GUIDE WIRE –(EXCHANGE LENGTH, REGULAR STIFFNESS)-
• Should be available in 0.021,0.025,0.032,0.035 and 0.038 inches size
• Should be between 240-300 cm long Should be available as straight & J-shaped tip
• Should be available in variable lengths of flexible/floppy end
• Should be available in variable J tip sizes
• Should be available fixed as well as movable core. | 1 | Nos | 269.89 ₹269.89 Lowest | - | 319 ₹319 |
| 1.07 | PTFE COATED GUIDE WIRE-REGULAR LENGTH, EXTRA STIFF SHAFT STRENGTH)-
(AMPLATZ TYPE)-
• Should be available in 0.032/0.035/0.038 inches size
• Should be 145-180 cm long
• Should be available as straight & J-shaped tip | 1 | Nos | - | - | 759 ₹759 Lowest |
| 1.08 | PTFE COATED GUIDE WIRE-EXCHANGE LENGTH, EXTRA STIFF SHAFT STRENGTH)-
(AMPLATZ TYPE)-
• Should be available in 0.032/0.035/0.038 inches size
• Should be 240-300 cm long
• Should be available as straight & J-shaped tip | 1 | Nos | - | - | 759 ₹759 Lowest |
| 1.09 | HYDROPHILIC DIAGNOSTIC GUIDE WIRE- (RADIFOCUS TYPE) REGULAR LENGTH, REGULAR STIFFNESS)-
• Must be available in 0.021, 0.025, 0.032, 0.035 inches size
• Should have super elastic alloy core
• Should have super flexible wire tip
• Should be available in straight and angled tip
• Should be between 150-180 cm long (regular and exchange length both should be available) | 1 | Nos | 789.89 ₹789.89 | - | 499 ₹499 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
25 Sept 2020, 5:00 pmClosed
Member Secretary
Member Secretary, RMRS , MBGH, Udaipur
Rate contract of Angiography items
2020_RNTMC_199440_3
03/9-9-2020
Open Tender
Miscellaneous Goods
Item Wise
365 days
Member Secretary, RMRS, MBGH
Please refer Tender documents.
2 documents required · 2 mandatory
₹400
Yes
Member Secretary, RMRS , MBGH, Udaipur
₹1 L
Yes
Member Secretary, RMRS , MBGH, Udaipur
23 Nov 2020
15 Sept 2020
26 Sept 2020
15 Sept 2020
25 Sept 2020
21 Sept 2020
16 Sept 2020
ANGIOGRAPHY ITEMS
FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 9Fr.) (standard Length) • Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French. • 10-11 cm Long • Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire • With haemostatic valve to prevent back leak and air aspiration • Integral side port with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back- out during insertion • With smooth and resistance free insertion
Radial glide sheath INTRODUCER SHEATH with outer diameter one Fr size Under. (6 Fr sheath with outer diameter of 5 Fr) • Size 5 French/ 6 French/ 7 French • Sheath should be between 10-20 cm long • 0.021 and 0.025 inch guide wire compatible • Hydrophilic Coating • 20-22 G needle length 2’ inch • Guide Wire Should be available in 3 forms A.) Plastic Short Angle B) Flex Straight C) Nitinol Floppy • With haemostatic valve to prevent back leak and air aspiration • Integral side port with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
LONG INTRODUCER SHEATH (20-50 cm long) (size 4Fr. -11Fr.) • Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 French • Sheath should be between 20-50 cm long • 0.035 or 0.038 inch guide wire and compatibility • With haemostatic valve to prevent back leak and air aspiration • Integral side port with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
TRANS RADIAL INTRODUCER SHEATHS 4F-6F- • Size 4 French/ 5 French/ 6 French • 07-10 cm long • Guide Wire Should be available in 3 forms A.) Plastic Short Angle B) Flex Straight C) Nitinol Floppy • Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches • 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibility • With haemostatic valve to prevent back leak and air aspiration • Integral side port with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With Dilator hub-lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
LONG BRAIDED INTRODUCER SHEATH- • Size 6 French/ 7 French/ 8 French/ 9 French and above • Should be 30-90 cm and above • 0.021 or 0.025 inch guide wire compatible • With haemostatic valve to prevent back leak and air aspiration • Integral side port with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion
PTFE COATED DIAGNOSTIC GUIDE WIRE –(EXCHANGE LENGTH, REGULAR STIFFNESS)- • Should be available in 0.021,0.025,0.032,0.035 and 0.038 inches size • Should be between 240-300 cm long Should be available as straight & J-shaped tip • Should be available in variable lengths of flexible/floppy end • Should be available in variable J tip sizes • Should be available fixed as well as movable core.
PTFE COATED GUIDE WIRE-REGULAR LENGTH, EXTRA STIFF SHAFT STRENGTH)- (AMPLATZ TYPE)- • Should be available in 0.032/0.035/0.038 inches size • Should be 145-180 cm long • Should be available as straight & J-shaped tip
PTFE COATED GUIDE WIRE-EXCHANGE LENGTH, EXTRA STIFF SHAFT STRENGTH)- (AMPLATZ TYPE)- • Should be available in 0.032/0.035/0.038 inches size • Should be 240-300 cm long • Should be available as straight & J-shaped tip
HYDROPHILIC DIAGNOSTIC GUIDE WIRE- (RADIFOCUS TYPE) REGULAR LENGTH, REGULAR STIFFNESS)- • Must be available in 0.021, 0.025, 0.032, 0.035 inches size • Should have super elastic alloy core • Should have super flexible wire tip • Should be available in straight and angled tip • Should be between 150-180 cm long (regular and exchange length both should be available)
HYDROPHILIC DIAGNOSTIC GUIDE WIRE- (RADIFOCUS TYPE) EXCHANGE LENGTH, REGULAR STIFFNESS)- • Must be available in 0.021, 0.025, 0.032, 0.035 inches size • Should have super elastic alloy core • Should have super flexible wire tip • Should be available in straight and angled tip • Should be between 240-300 cm long (regular and exchange length both should be available)
DIAGNOSTIC JUDKINS SHAPE CATHETER (JR/JL) & PIGTAIL, Multi purpose, AMPLATZ, IMA, NIH COURNAND catheter etc. • 4 French/5 French/6 French/7 French/8 French/ catheters in various standard curves and lengths should be available Like JL 3.0 To 5.0 and so on for each type for catheter
TRANSRADIAL DIAGNOSTIC CORONARY CATHETER (Opti torque type) • 4 French/5 French/6French/ diagnostic coronary catheters must be with various curves and shapes like ULTRA CURVE, IKARI CURVE, TRANSFORMER CURVE, TRACTIVE CURVE, and various shapes like tiger jockey shapes etc. and length dedicated for trans radial coronary angiography and brachial approach also • Soft tip compression (GF) for atraumatic tip should be equal to or less then 100 • Soft atraumatic, radiopaque tip with increased visibility • Double-braid wire enhancing strength, torque and kink resistance
SPECIAL SWAN GANZ CATHETER WITH Safety Wedge:- • 4 F catheter should allow the passage of at least 0.021 inch, 5F-0.025 inch, 6 F-0.035 inch and 7 F, 8F-0.038 inch, PTFE/ hydrophilic guide wire • Must be available in 4F, 5F, 6F, and 7F and 8 Fr. Sizes • Catheter should be tapered at tip to ensure uniform diameter of the whole catheter • 10 cm marking along catheter body to confirm insertion depth. • Balloon at distal tip with standard shape & volume. Kit must be with all accessories.
BERMAN CATHETER- • Must be available in 4F, 5F, 6F and 7F sizes • Should have 6-8 holes proximal to the balloon for dye injection • Catheter should be tapered at tip to ensure uniform diameter of the whole catheter • 10 cm marking along catheter body to confirm insertion depth. • balloon at distal tip with standard shape & volume. Kit must be with all accessories.
SYRINGE FOR PRESSURE INJECTOR INSTALLED IN RNT MEDICAL COLLEGE, UDAIPUR- • Should be compatible with existing machines at RNTMC • Should be of standard volume & material
DOMES FOR TRANSDUCER FOR INVASIVE PRESSURE MONITORING- 1. Should be compatible with existing available system like Bard, Philips, should meet or exceed data Scope at RNTMC 2. Should meet or exceed highest standards 3. Quality Certification form authorized agencies to be provided
INTRAVASCULAR RETRIEVER-SNARE (‘AMPLATZ GOOSENESK’ TYPE)- Snare kit should include with all accessories like sheath etc. • A snare and its compatible sheath • Should have nitinol shaft • Should have 90 degree preformed snare loop • Variable size of loop (5-35 mm)
INTRAVASCULAR RETRIEVER- MICROSNARE (‘AMPLATZ GOOSENECK’ TYPE)- With all accessories like sheath etc. Microsnare kit should include • A microsnare, compatible micro-catheter micro-catheter, introducer and a torque device • Should have nitinol shaft • Should have 90 degree preformed snare loop • Variable sizes (2-7 mm)
RENAL DOUBLE CURVE CATHETER, HEAD HUNTER, SIMMONS-SONS, VERTEBERAL SHEPHERED COOK • In various standard lengths and curves. 4F TO 7F for femoral & radial approach (separate length must be available)
RADIAL COMPRESSION BAND (TR BAND TYPE)- • Special two Balloon designed for spot compression of radial puncture site.
MANIFOLD WITH ATTACHED TUBINGS (ANGIO KIT) • Manifold 2 port with smooth movements of knob • One luer lock control syringe (10 or 12 ml) for contrast injection • Two large bore tubing (with flow regulating knob) of length 150-200 cm one for pressure monitoring and another for contrast, with flow regulating knob.
Maxwell Scientific Store
M.G. DISTRIBUTORS
M.G. DISTRIBUTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .