Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.1 L+₹3.5 L (21.1%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.3 L+₹5.7 L (34.5%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.8 L+₹6.2 L (37.7%)Rejected-AOC M S GMR CO 151 2 MAHENDRA NILAYAM 11TH MAIN 2ND CROSS BEHIND SRI RAMA TEMPLE KAMMAGONDANAHALLI JALAHALLI WEST BANGALORE 560 015 | BENGALURU URBAN | KARNATAKA | 560015 | L4 | Rejected-AOC L4 | |
| 5 | L5₹23.4 L+₹6.9 L (41.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jan 2020, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIRS/REPLACEMENT OF LT PANEL BOARD, MCCBs SERVICING OF LT ACB AND LT OH LINE/UG CABLE AND ALLIED WORKS AT AFS STATION YELAHANKA
2019_MES_307422_2
8750/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹60,000
Yes
22 Jun 2020
9 Jan 2020
18 Jan 2020
9 Jan 2020
16 Jan 2020
10 Jan 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in not exceeding 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm all as specified and as directed.
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable all as specified and as directed. Note:- For measurement purpose punned thickness only shall be considered.
Supply and laying in trenches, LT underground cable of size 4 core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-cahrge.
All as per item No 6 here-in-before but 10 sqmm 4 core
All as per item No 6 here-in-before but 25 sqmm 3.5 core
All as per item No 6 here-in-before but 35 sqmm 3.5 core
All as per item No 6 here-in-before but 50 sqmm 3.5 core
All as per item No 6 here-in-before but 70 sqmm 3.5 core
All as per item No 6 here-in-before but 95 sqmm 3.5 core
All as per item No 6 here-in-before but 120 sqmm 3.5 core Note: For Sl No 6 to 13 ,necessary excavation and connected items shall be measured and paid separately under respective items of this schedule
Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 50/80/100mm dia suitable for 0.4mpa working pressure.
Suppl and fix GI tube light grade of dia 40mm incl fixing of necessary clamps for protection of cable laying and fixed to walls/pole etc. all as specified and directed.
Supply and laying GI tubing light grade 50 mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable
Supply and laying GI tubing light grade 80 mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable
S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15cm size including taking down old unserviceable one.
Restringing of LT overhead lines conductor of any size (Conductor will be measured separately, if required)
Supply and fix terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm product code no GSJB-1414 including ,Backlite 4 way connector,MS Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections incl MCB SP 6-32 Amps complete all as specified and as directed. Make - Sintex
S&F PVC spacers for 4 wire LT 1100 Volts grade overhead line all as directed.
S&F PVC spacers for 2 wire LT 1100 Volts grade overhead line all as directed.
Supply and fix cable route indicator made out of 3 mm thick MS sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size of cable with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed by Engineer- in- charge.
Supply,install and commmissiong of LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coats of syntehtic enamel paint over a coat of red oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps 4 pole ,415 Volts,50 Hz of breaking capacity 16 KA as incomer including taking down old terminal boxes complete all as specified and directed.
Supply and fix bus bar box of size 0.45x0.3x.50 mtrs fabricated by 3 mm thick MS sheet outdoor type,mounted/fixed on angle Iron frame of MS equal angle size 40x40x6mm of height 0.90 mtr and fixed in ground complete box with dust/vermin proof including aluminium flat of size 50x 6 mm fixed as bus bar over the insulators,sleeved for three phase and neutral and spray painting the box with two coats of enamel paint over a coat of metal primer complete all as specified and directed by Engr-in-charge including necessary excavation,PCC for fixing the box all as directed.
Supply and jointing staright through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 25 sqmm to 3.5x 70 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge
Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for3.5x 95 sqmm to 3.5x 120 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge
Supply only CTs suitable for existing LT panel board of capacity 400 to 630 Amps all as specified and as directed.
Supply only CTs suitable for existing LT panel board of capacity 250 to 320 Amps Amps all as specified and as directed.
Supply only CTs suitable for existing LT panel board of capacity 63 to 200 Amps Amps all as specified and as directed.
Supply only LED indicator lamps (R Y B ) suitable for existing panel all as pecified and directed.
Supply only MCCB 400 Amps,4 pole 415 Volts,50 Hz,36 KA adjustable thermal and magnetic based type all as specified and directed.
All as per item no 33 Above but 200 Amps 4 pole 36 KA adjustable and magnetic based type
All as per item no. 33 Above but 100 Amps 4 pole 25KA adjustable type
All as per item no. 33 Above but 63 Amps 4 pole 16KA adjustable type
Supply only digital ammeter 100 amps range suitable for mounting existing panel all as specified and directed
Supply only digital voltmeter 500 Volts range suitable for mounting existing panel all as specified and directed
Preparing old faded painted surfaces of 9 m/11 m long steel tubular/RCC/PCC/Rail pole complete including all accessories such as cross arms bracings, brackets etc and paints with two coats of Aluminium paint of approved colour including writing pole number with paint same as existing earlier all as directed.
Preparing of old faded paint surface and painting with paint to existing LT PCC/RCC/steel tubular poles of size 9m/11 mtr long upto the height of 1.2m from the bottom with approved white and blue colour alternatively including numbering of poles same as existing earlier all as directed
Supply and fix sheet metal enclosures for MCB distribution board 415 Volts Triple pole and neutral 4 way Double door flushed inside the wall with 200 Amps rated busbar including flushing the DBs inside the walls and making good the disturbed surface also matching with the existing surface incl taking down old unsv DBs complete all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 12 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MCB Triple pole and Neutral , 415 volts, 35 to 63 Amps 10 KA, all as specified and as directed.
Supply and fix MCB Single pole & neutral 240 volts, 5 to 30 Amps 10 KA all as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 30 Amps 10 KA all as specified and as directed by Engr-in-Charge.
Supply and fix Triple pole and earth encloser(32A 3P+N+E) with a three pin and earth plug socket complete all as specified and directed. Make - Indo Asian Cat No. 811961 or equivalent Schneider/Legrand.
Supply and Fix MCB TPN 32 Amps, 10 KA rupturing capacity. Make - Indo Asian Cat No. 811239 or equivalent Schneider/Legrand.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 32x6 mm upto 7.5 meter length by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I of 2009 connected to and including earthing test point or disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 20mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 all as specified and directed by Eng-in-charge.
Dismantling taking out air circuit breaker 1000 amps capacity 3 pole 415 volts 50 Hz and removing mechanical assembly fixed and moving contact set and replacing mechanical parts like spring, bushes, levers and checking for worn out contacts, overvoltage and under voltage settings and replacing the following electrical parts (i) fixed contact assembly (ii) moving contact assembly, (iii) pole assembly (iv) Arc chute . Reassembling, testing and commissioning completely all as directed by Engineer in charge Note:- Replacement of unserviceable electrical parts will be measured and paid for separately under relevant items of this schedule.
Supply and fixed contact assembly for 1000 Amps 3 pole 415 volts ACB all as specified and as directed by Engineer in charge
Supply only moving contact assembly for 1000 amps 3 pole 415 volts ACB all as specified and as directed by Engineer in charge.
Supply only pole assembly for 1000 amps 3 pole 415 volts ACB all as specified and as directed by Engineer -in- charge.
Supply only Arc chute for 1000 amps 3 pole 415 volts ACB all as specified and as directed by Engineer- in- charge.
Dismantling taking out air circuit breaker 800 amps capacity 3 pole 415 volts 50 Hz and removing mechanical assembly fixed and moving contact set and replacing mechanical parts like spring, bushes, levers and checking for worn out contacts, overvoltage and under voltage settings and replacing the following electrical parts (i) fixed contact assembly (ii) moving contact assembly, (iii) pole assembly (iv) Arc chute . Reassembling, testing and commissioning completely all as directed by Engineer in charge Note:- Replacement of unserviceable electrical parts will be measured and paid for separately under relevant items of this schedule.
Supply and fixed contact assembly for 800 Amps 3 pole 415 volts ACB all as specified and as directed by Engineer in charge
Supply only moving contact assembly for 800 amps 3 pole 415 volts ACB all as specified and as directed by Engineer in charge.
Supply only pole assembly for 800 amps 3 pole 415 volts ACB all as specified and as directed by Engineer -in- charge.
Supply only Arc chute for 800 amps 3 pole 415 volts ACB all as specified and as directed by Engineer- in- charge.
Supply and fix aluminium lugs suitable for UG cable of size 6 Sqmm to 25 Sqmm all as specified and as directed.
All as per item No 65 but of size 35 Sqmm to 50 Sqmm
All as per item No 65 but of size 70 Sqmm
All as per item No 65 but of size 95 Sqmm
All as per item No 65 but of size 120 Sqmm
Preparing old faded surface of existing LT panel/feeder pillar located at various places by rubbing and removing the old paint complete and painting with two coats of super enamel paint over a coat of red oxide primer including writing of incoming and outgoing feeder details as required size of letters all as specified and directed.
Cleaning of all the substations located at technical and domestic area once in a month as per Engr-in-charge's instructions by applying cloth for removing dirt on all the installations located inside the sub stations and cleaning also includes the following:- Cleaning of side wall and roof, Cleaning of floor, Removing the dirt away from the sub station all as specified and as directed. Note:-(i) The rate for labour to be included in the quoted rate. (ii) The quoted rate shall also include the rate of materials like cottton, Broom, MAFF, Stick for mountingBroom, Phenol which are required for the cleaning of installations
devan enterprises
Vinayaka Enterprises
G.M.R.& CO
RAMESH BABU CO
Shanthi Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .