Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹2.5 Cr | L1 | Accepted-AOC Being lowest and reasonable. |
| 2 | L2₹2.7 Cr+₹20.1 L (8.01%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹2.7 Cr+₹20.1 L (8.01%) | L2 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
11 Jun 2022, 6:00 pmClosed
Chief Engineer
HQ CE DELHI ZONE, DELHI CANTT-10
ADDN ALTN AND SPECIAL REPAIR TO BLDG NO P-33 AT IML UNDER GE (SOUTH) AT DELHI CANTT-10
2022_MES_505845_2
CA NO CEDZ/TOKEN-08 of 2022
Open Tender
Civil Works
Item Rate
270 days
DELHI CANTT
MES contractor enlisted in MES under class B cat a i having deposited Standing Security of Rs 400000.00 with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹2,000
GE South Delhi Cantt
₹3.3 L
Yes
4 Aug 2022
7 May 2022
13 Jun 2022
7 May 2022
11 Jun 2022
28 May 2022
Amount
M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members :- (i) Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing including light grit blasting where necessary as recommended by Engr-in-charge. (ii) Further, cleaning using biocide(as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. Sand blasting to be done to remove trace of paint. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer. (vi) Apply a more coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete all as specified and directed. (vii) Sprinkle sand cover over surface to receive new
M&L for followings :- (i) Removing plaster & finishes all around the coloumns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. Superficial area of member to be considered for measurement
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
Providing and fixing NRV Nozzles- a. Identifying the building component to be repaired for structural cracks/ porosity/ honeycombing/ imperfections by injection grouting. b. With the help of electrically operated angle grinder with diamond saw blade, make V shaped groove crack line, for identified cracks, of up to 10mm wide and up to 10mm deep. The crack line will be cleaned by air blower. c. Sealing of exposed V groove 10 mm deep and 10 mm wide crack line/ honeycombing/ imperfections with solvent free, moisture tolerant, thixotropic, structural adhesive mortar.
d. Drilling holes of 12mm dia, up to 75-100 mm deep in beams and columns and 50-75mm deep(but not exceeding half of the thickness of the slab) in slab at the interval of 300-500 mm in staggered manner or along the crack line as directed by the Engr-in-charge including cleaning of the holes by air blower and inserting 10-12 mm dia NRV (Non-Returnable Value) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix it inside the hole by applying thixotropic epoxy solvent free moisture tolerant putty to ensure complete sealing and allow to cure the system for minimum of 8 Hrs before grouting including cutting nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work of grouting, etc. complete
Providing and Grouting Injecting low viscosity grout by pressure and using pressure epoxy injector with accessories till nozzles refused to accept the grout, Including Mixing material components part a and part b in required quantities as per manufacturer instruction by weigh batching Filling the grouting gun with grout, and maintaining desired pressure in the gun, air compressor and at exit (minimum 3 to 4 kg/Cm2) by a mechanism to monitor both pressure gauges and controlling the same by release valves and release the grout as per requirement simultaneously to grout the structural element through prefixed nozzles till its refusal. Seal the nozzle with thixotropic epoxy putty after the refusal. The epoxy shall be Sikadur 52 LP IN and shall have following requirement : Viscosity : ~ 250 mPas at +30°C Mixed Density : 1.1 kg/l (at +27°C) TensilSt : ~ 50 N/mm2 (after 7 days at +30°C cure) (as per ASTM D 638), Compressive St : ~ 70 N/mm2 (7 Days ) (As per ASTM C 579) Modulus of Elasticity in Tension ~ 2000 N/mm2 (after 7 days at +30°C cure) (As per ASTM D 638)
Note :leakages through other nozzles or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost
Supply & fixing 12mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specifed by manufactuer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA). (The cost of drilling hole &chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed. Steel is also measured with this item.
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 12 & 16mm dia bar-drilling length 120 to 160mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item)
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L and applying on hardened concrete surface organic migratory corrosion inhibitors (MCI) of minimum two coats of amino alkanolamine (AMA) nature. the location will be approved by Engr-in -Charge. The product shall have proven test report by mott MacDonald and BRE
Description of Work / Item(s)
Amount
Demolition unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of PCC in ground floors and pavings n.exc 15 cm thick below or above ground level (unreinforced) complete all as specified and directed
Demolition of cement concrete in above ground floors exc 15cm thick above ground floors complete all as specified and directed
M&L for applying a coat of cement slurry @ 0.488 Kg/Sqm mixed with tapercreate @ 0.253 Kg/Sqm after cleaning and drying the old/new surfaces(Make of tapercreate M/S CICO Engg Services) then applying the layer of fibre glass cloth while the above coat is still green. The overlap of fibre glass cloth shall be not less than 100 mm.(Make of fibre glass cloth M/S The Structure Water Proofing Co Pvt Ltd) and then applying 1.5 mm thick layer @ 1.288 Kg/Sqm mixed with taper create @ 0.570 Kg/Sqm and coarse sand @ 1.289 Kg/Sqm. Allow the treatment to air curing for four hours followed by water curing for 48 hours complete all as specified and directed
M&L for 10 mm thick cement plaster on brick/ concrete surface in CM 1:3, finished even and smooth surface with out using extra cement but mixing water proofing compound at the rate of 2% of cement by weight complete all as specified and directed (Note :-WPC shall be paid separately).
Supply only liquid water proofing compound complete all as specified and directed
M&L Cement concrete Type E-2 (1:5:10) using 40 mm graded stone aggregate in mass concrete in sunken floor complete all as specified.
M&L 75 mm thick PCC type D-2 (1:3:6) using 40 mm graded stone aggregate as in sub base of flooring complete all as specified and directed
S&F coloured glazed ceramic tiles of size 350mm x 250mm x 7 mm thick, on vertical surfaces such as dados etc, set and jointed in neat cement slurry and pointed in white cement over and including 10 mm thick rendering in CM 1:4 including dismantling old tiling including cement mortar bedding (but not backing) of any description and thickness and removal of rubbish off the premises complete all as specified and as directed.
M&L for 16-18 mm thick marble (Green) udaipur machine cut bedded jointed & pointed with grey cement slurry including cutting & polishing over 15mm thick screed bed in CM 1:4 complete all as specified and directed
M&L non skid coloured ceramic tiles jointless 7 to 8mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match over and including 15mm thick screed bed in cm 1:6 for laying floor finish complete all as specified and directed
M&L 40mm thick PCC flooring 1:2:4 type B1 (using 20mm graded stone aggregate) finished even & smooth without using extra cement complete all as specified and directed
M&L 100mm thick PCC flooring 1:2:4 type B2 (using 40mm graded stone aggregate) finished even & smooth without using extra cement complete all as specified and directed
S&F for rorational moulded of 500 Ltr capacity polyethylene water storage tanks (cylindrical vertical with closed top with threaded type lid cover) in position all as specified in SSR Part-I complete all as specified and directed
M&L 75mm thick PCC 1:3:6 type C2 as in plinth protection finished even & smooth without using extra cement and groove filled with bitumen grade 'A' complete all as specified and directed
S&F viterous china wash down water closet pan (Pedestal pattern EWC) white incl 'P' or 'S' trap and making good the disturbed surface to match with the existing complete all as specified and as directed.
S&F plastic water closet (EWC) seat cover white closed pattern with flat bottom and cover incl mild steel chromium plated hinging device complete all as specified.
S&F brass chromium plated health faucet for WC with 1.20 Mtr long PVC flexible pipe complete all as specified and directed .
S&F bathroom glass corner shelf with side rail of size 300mm best quality (as per sample) complete all as specified and directed
Supply and fixing in repairs Vitreous China urinals, full stall type type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flusing cistern with brackets push pipe grating, waste pipe and union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern and trap). complete all as specified and directed
M&L for vitreous china wash hand basin flat back size 550x400 mm size white excluding taps waste chain and plug and porcelain stopper but including brackets and 32 mm dia waste fittings brass chromium plated with long screwed shanks and fly nuts, 32MM X 600 MM long PVC waste pipe complete flange end bedded in red lead cement and other end fixed complete all as specified and directed
Dismantling Cast iron pipe 100 dia incl all fittings of any description and in any position complete all as specified and directed
Dismantling Cast iron pipe 75mm dia incl all fittings of any description and in any position complete all as specified and directed
S&F 100 mm dia sand cast iron soil waste and vent pipe in any length with or with out ear with cement joint fixed to walls including MS steel flat iron 25X3 clamp complete all as specified and directed
S&F 75 mm dia sand cast iron soil waste and vent pipe in any length with or with out ear with cement joint fixed to walls including MS steel flat iron 25X3 clamp.
S&F 100mm dia Bends with or without oval assess door complete all as specified and directed
S&F 75mm dia CI Bends with or without oval assess door or diminishing pieces or tapers complete all as specified and directed
S&F Branch pieces,Tee junction with bore of pipe 100 mm, single (equal or unequal), ordinary or inverted, spigot or socket type or with parallel branches with Ovel Access door complete all as specified and directed
S&F Branch pieces, Tee junction with bore of pipe 75 mm, single (equal or unequal), ordinary or inverted, spigot or socket type or with parallel branches with ovel Access door complete all as specified and directed
M&L 75 mm out let dia CI floor trap incl jointing to waste pipe in run lead complete all as specified and directed
M&L in repair 150X150 mm Salt glazed stoneware gully traps, square or round mouthed type 'P' complete all as specified and directed
Taking down cement plaster on brick/concrete surface including racking out joints heacking for key scrubbing down with water etc complete all as specified and directed
M&L rendering with ready mixed plaster 15 mm thick on any type of faces of brickwork or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering with ready mixed plaster 5 mm thick on ceiling surfaces surface, finished even and smooth without using extra cement complete all as specified and directed.
Taking down chowkhats or frames with shutter exc 1.5 sqm and nexc 4.00 sqm each but without taking off shutters from the frame complete all as specified and directed
All as per Srl item No 35 here-in-before but nexc 1.5 sqm each
M&L for Aluminium anodised with powder coated door with shutter , chowkats /frame made with Aluminium section of size 100 x 44 x 2 mm thick vertical styles of shutters made with sections 84 x 44 x 2 mm thick and top / middle / bottom rail of shutter with sections 112 x 44 x 2mm thick including 5 mm thick tinted glass panes , inserted including necessary fixing arrangement ,jointing cleats ,glazing clips , rubber packing aluminium anodised beading, screw sets, floor stoppers, hinges, tower bolts 200 mm size, mortice lock 100 mm size 4 lever , round handles etc , fitted to shutter and frames fixed in positon including hold fast of size 25 x 3 mm flat , 150 mm long , 6 nos in each frame including cutting holes in brick work and embedded in PCC 1:2:4 bed block of size 150 x 150 x 150 mm each and match the existing surfaces complete all as specified and directed
S&F factory made solid panel FRP door shutter 30mm thick premoulded design made out of solid core, laminated 1.5 mm to 2mm thick GRP/FRP made of superior all seson, weatherresistant polyyester get coat followed by laminating polyster resin of 450 gm glass mat termite all as per manufacturers specification.
S&F factory made solid FRP door frame of size 90mm x 45 mm made out of FRP sheet , complete all as specified and directed
S&F 100mm long butt hinges stainless steel complete all as specified.
S&F 150mm long aluminium anodised barrel tower bolt extruded section all as specified.
S&F 150mm long extruded aluminium alloy handle complete all as specified.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed
S& F in repairs factory made PVC cupboard frame of size 75 mm x 40 mm with a wall thikness of 4mm , made out of extruded 4 mm thick prelam PVC sheet of density 600 / cbm manufactured by an ISO -9001-2015 certified company , reinforced with 15 mm x 15 mm MS square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners and jointed with 2 nos of 150 mm long brackets of 10 mm x 10 mm MS Square tubes .The door frame shall be fixed to wall using 65 /100 long MS screws to be provided for each vertical member and minimum of 2 nos of screw to be provided horizontal member etc. complete all as specified and directed
S&F factory made PVC flush type shutter and partition of 18 mm thickness with one side lamination & other side balancing lamination sheet consisting of Carcass 18mm thick PVC sheet of density 600 / cbm manufactured by an ISO -9001-2015 certified company ,and all required brackets 5.5 screw etc. The panell shall be fabricated using adhesive and screws where ever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish as per make and specificationmentioned as per drawing including necessary fittings, locking and fixing arrangement ie piano hinges, handles, magnetic catches etc complete all as specified and directed
Hacking out old broken glass of any size, thickness, quality or description from metal frame nexc 1.5 sqm each complete all as specified and directed
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares not exec 0.5 sqm each pane complete all as specified and directed
Preparation of newly plastered surfaces on wall complete incl M&L for three coats of white wash on wall complete all as specified and directed
Preparation of newly plastered surfaces on wall complete incl M&L for two coats of oil bound distemper including a coat of alkali resistant cement primer, white or tinted complete all as specified and directed
Preparation of newly plastered surfaces on Ceiling complete incl M&L for two coats of oil bound distemper including a coat of alkali resistant cement primer, white or tinted complete.
All as per Srl item No 50 here-in-before but three coats of white wash on ceiling complete all as specified and directed
M&L preparation of old decorated plastered or plastered wall surfaces including pilasters and cornices etc including brooming down or steel wire brushing and applying two coat of white lime wash complete all as specified and as directed.
M&L for grinding existing internal surfaces complete removal through electrically operated grinder preparation of surfaces complete all as specified and directed
M&L for priming on wall plastered and other surfaces with alkali resistant priming paint over 2mm thick wall care putty complete all as specified.
M&L for distermper on walls two coat with distemper oil emulsion white or tinted over 2mm thick wall care putty complete all as specified.
M&L for priming on ceiling plastered and other surfaces with alkali resistant priming paint over 2mm thick wall care putty complete all as specified.
M&L for distermper on ceiling two coat with distemper oil emulsion white or tinted complete all as specified and directed
M&L for preparation of old decorated surfaces on ceiling & applying two coats of white lime wash complete all as directed.
M&L for preparing old decorated wooden surfaces of any desc not otherwise described over 10 cm width or girth & applyijng one coat of synthetic enamel paint of any colourcomplete all as specified.
M&L for preparing old decorated steel surfaces of any description not otherwise described over 10 cm width or girth & applying one coat of synthetic enamel paint of any colour complete all as specified.
M&L for preparation of new surface of wall and applying two coats of 100% anti fungal acrylic emulsion exterior grade whether proof paint over a coat of weather resistant acrylic primer on wall in operation of each coat wise and after application of first coat of primer / paint surface shall be got approved by GE in token of their satisfactory application and there after subsequent coat shall be applied complete all as specified and directed. Note: The surface shall be got approved by the GE before application of paint.
Cutting chases for concealed water tubing or concealed conduct wiring etc.and making good cutting n exc 10cm girth in brick wall complete all as specified and as directed
S&F 15mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as directed.
S&F 20 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as directed.
S&F 25 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as directed.
S&F 32 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as directed.
S&F 50 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as directed.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 15 mm dia including taking down of old GI pipes and connections complete all as specified and directed
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 20 mm dia including taking down of old GI pipes and connections complete all as specified and directed
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 50 mm dia including taking down of old GI pipes and connections complete all as specified and directed
S&F in repairs 10 ltrs capacity PVC Low level flushing cistern including PVC syphon and float valve with float, PVC long bend for out let connection of cistern with WC complete fixing and connecting bend with WC all as specified and directed.
S&F 15 mm bore dia of pipe fancy type brass CP mixer, cast copper alloy , with capastan heads, chromim plated, screwed down high pressure, with or withour lettered 'HOT or Cold' with long screwed shanks and fly-nuts, acrewed for iron pipe and fixed complete all as specified
Cutting of trees including cutting of trunk n.exc 30cm girth and branches and digging out roots from floor or roofs and walls of up to four storied bldg and making good the dismantled portion in cement mortar 1:3 to match the existing surfaces complete all as specified.
Dismantling Brick tiles or terracing tiles single layer on roofs complete all as specified and directed
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as directed
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and directed
M&L 50 mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5 mm graded aggregate), as in roof ,padding to maintain the uniform slope complete all as specified and directed. Note : - WPC shall be measured & paid separately.
M & L for rendering 10 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement all as specified and directed.
S&F APP based polymeric water proofing membrane minimum weighing 3 Kg/sqm and 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm laid over and including applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm by torch application including cleaning of surface all as per approved manufacturer's instructions. complete all as specified and directed Note:-The water proofing treatment shall be carried out by manufacturer or their auth applicators as per manufactures instruction and as directed
M&L for preparation of new surface of APP membrane and applying two coats of aluminium paint at surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for complete all as specified and directed
M & L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and directed
Supply only water proofing compound. complete all as specified and directed
Demolition of brick work built in CM incl quoins, arches, pillers etc complete all as specified and directed
M&L brick work in cement mortar (1:6) using sub class 'B' bricks, straight or curved on plan exc 6 mtr mean radius complete all as specified.
M&L brick work in cement mortar (1:4) using sub class 'B' bricks, straight or curved in plain exc 6 mtr mean radius in half brick th wall complete all as specified and directed
Demolition of RCC of any description, in any position roofs, floors (other than ground floors), beams staircases, landing, chajjas, RCC overhead tank and similar suspended work and Removing excavated material /demolition material exc. 1.50 km but n exc.5 km including taking down from upto four storey complete all as specified and directed
M&L for form work to chajjas and similar items including edges thick finished rough complete all as specified and directed
M&L for RCC 1 : 2 : 4 type B-1 (using 20mm graded stone aggregate) as in chajjas complete all as specified
S&F 10mm dia and over TMT bar as in reinforcement of RCC of any description cut to length bent to shape required including cranking, bending, binding with MS wire not less than 0.90mm dia complete all as specified and directed
S&F 8mm dia TMT bar as in reinforcement of RCC of any description cut to length bent to shape required including cranking, bending, binding with MS wire not less than 0.90mm dia complete all as specified and directed
M&L in repair 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints laid in trenches or in floors including Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) and fixed to wall with MS flat iron clamp 25X3 mmcomplete incl taking down old rain water pipes complete all as specified and directed
M&L in repair PVC (SWR) bend any radius suitable for 110mm bore of pipe complete all as specified.
M&L for RCC 1 : 2 : 4 type B1 using 20mm graded stone agg as in roof slab suported on wall beam and columns in floor slab landings balconies canopies deck slabs and in shelves and the like complete all as specified
M&L for form work to soffits of suspended slab such as roof slab and similar work not exc 200mm thick finished rough complete all as specified and directed
All as per Srl item No 96 here-in-before but edges of concrete slab
M & L for 20-22 mm thick Machine cut kota single piece stone slab for steps and size 22''x22'' for flooring over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 15mm thick screed bed in CM 1:6 and rounding of edges, rubbing and polishing complete all as specified and directed.
All as per Srl item No 98 here-in-before but in riser of steps, skirting dado and pillar laidown cement screed complete all as specified and directed.
Material and labour for re-inforced precast cement concrete 1:2:4 type B-1 using 20 mm graded aggregate as in manhole cover slabs round, square or rectangular in shape set in cement mortar 1:4 complete all as specified and directed
Material and labour for re-inforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, coping, benching, roof kerb or mud stops, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, apex stones, including form work to concrete surfaces complete all as specified and directed
Supply and fix in repairs cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches or in floors or fixed to walls, bore of pipe 50 mm complete all as specified and directed
Supply and fix in repairs cast iron cowl for 50 mm bore of pipe complete all as specified
S&F Chromium plated soap dish with screw complete all as specified and directed
S&F aluminium Peg set of 3 pegs as per sample complete all as specified and directed
S&F Grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed
S&F Brass chromium plated shower rose 125mm size with arm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F Grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and directed
M&L Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed
M&L Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) complete all as specified and directed
M<owel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and directed
M&L Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed
M&L 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and directed
S&F 15 mm dia Bib taps long body, cast copper alloy with crutch or capstan head , screwed down, screwed for iron pipe or for brass ferrule and fixed, fancy type chromium plated complete all as specified and directed
S&F in repair 15 mm dia fancy type Bib taps long body, cast copper alloy with crutch or capstan head , screwed down, screwed for iron pipe or for brass ferrule and fixed, fancy type chromium plated complete all as specified and directed
S&F for 15mm fancy type chromium plated with long shunk and cup concealed type stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed (Minimum weight 15mm-90gms) complete all as specified and directed
S&F for 15mm fancy type chromium plated stop valves/angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed (Minimum weight 15mm-90gms) complete all as specified and directed
S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed
S&F 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed
S&F drappery curtain rods stainless steel 30mm dia of approved quality with decorative wooden finish and two number brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod including 8 Nos (min) match up rings etc complete all as specified and directed.
Supply & Fix 15mm nominal internal bore PVC connection 450 mm long with two brass nuts and PVC washer complete all as specified and directed
M & L Chequered cement concrete tiles 25cm x 25cm x 22 - 25mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigment laid on screed bed or bedding layer of mortar 20 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed
M & L for vitrified ceramic double charged coloured tiles 10mm thick (square/rectangular) polished, area of each tile exceeding 0.36 but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchset & jointed in neat cement slurry & pointed in coloured cement to match over and including 15mm thick screed bed inCM 1:6 for laying floor finish & roughening of floor by chiseling
M&L for vetrified ceramic double charged coloured tile 10 mm thick (rectangular) of size 600 x 100mm as in skirting set and jointed in neat cement and pointed in white or coloured cement to match etc including 10mm thick screed plaster in CM 1:4, complete all as specified and directed.
M&F for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing and including 20mm thick screed bed in cm 1:6 for laying floor finish & roughening of floor by chiseling complete all as specified and directed
M&F for 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing and including 15mm thick rendering on wall in CM 1:4 complete all as specified and directed.
S & F 40mm dia 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene random fittings for over flow pipe of PVC water tank including connection to tank fixed complete to walls, ceilings or in floors etc complete all as specified and directed
S & F 40 mm PP-R connection nipple for water tank to overflow PP-R pipe 40mm dia complete all as specified and directed
S&F in repair of 15mm Stop valves, cast copper alloy screwed pressure, with capstan head , screwed both ends for iron pipe for unions and fixed, but fancy type, chromium plated with long shank concealed type complete all as specified and directed
S&F MS round bars 10 mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for guard bars complete all as specified and directed
S&F fabricated aluminum window with powder coated anodized aluminum frame of section 63.5mm x 38.10mm x1.5mm thick, shutter with section 47.62mmx44.45mmx1.5mm thick including aluminum anodized “D “ handle, hinges, peg stays, tower bolts, etc including jointing cleats for fixing builder's hardware fittings & stainless steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples including necessary fittings/fixture /aluminum snap beads and provn of window AC/Cooler opening whre ever required with openable shutters complete all as specified. Note: Measurement shall be taken for clear opening i.e. out to out of window frame as a whole including all fittings and fixtures and no extra shall be paid separately.
M&L for 6mm dia powder coated aluminium decco grill, (minimum thickness of powder coating 50 micron), section No-104, 100mm aperture of hexagonal design and pattern as approved complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of 100% anti fungal acrylic emulsion exterior grade whether proof paint over a coat of weather resistant acrylic primer including preparation of old decorated surface of wall in operation of each coat wise and after application of first coat of primer / paint surface shall be got approved by GE in token of their satisfactory application and there after subsequent coat shall be applied complete all as specified and directed. Note: The surface shall be got approved by the GE before application of paint.
Demolition of cement concrete (Reinforce) of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L preparation of old surfaces of steel of any description not otherwise described width or girth and applying two coats of synthetic enamel paint complete all as specified.
M&L for Providing type B0 1:2:4 (12.5mm graded aggtegate) precast cement concrete louvres and jallies, 25mm thick (mea sured solid), set in cement mortar 1:4 including all mould- ings but excluding frame complete all as specified.
Excavation in trenches n.exc1.50m wide and n.exc 1.50 m in depth for manholes & sewage lines and getting out in soft/loose soil complete all as specified and directed
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
Removal of excavated surplus soil to a distance n.exc 50 metre at a level n.exc 1.5m above or below the starting point. complete all as specified and directed.
S & F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, laid in trenches or floors of 100 mm dia sand cast pipe complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes of 100mm bore including packing under and haunching against sides of pipes after they are laid and tested. complete all as specified and directed.
S&F in repair 0.56mm plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, joints, drip and straight flashing (length and girth as fixed) complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
M&L for MS hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and directed.
M&L preparation of New surfaces of steel of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over and including a coat of redoxide, zinc chrome primer complete all as specified.
Description of Work / Item(s)
Amount
Taking down carefully the old U/S aluminum point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed
M&L light/fan/bell point controlled by one way modular switch with PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.5 Sqmm suitable for fixing in concealed PVC conduit with modular sunken pressed steel terminal boxes 2 mm thick of required size and modular white cover plate and frame in different module housing for fixing modular switches/modular socket and modular fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.5 Sqmm used as earth wire to commen earth and connected to common dolly drawn in same conduit complete all as specified and directed (Note :- Rates are inclusive of cutting/chases for mounting Modular metal box concealed in wall and making good to the disturbed surfaces with OBD/colour wash/white wash and wall putty where ever required)
(a) One light / fan / bell point controlled by one No one way switch
(b) One light point controlled by two 2-way switch
(c ) One 3 pin 5 Amps socket outlet point controlled by one number one way switch on independent board Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 sqmm for earthling complete
(d) One 3 pin 5 Amps socket outlet point controlled by one number one way switch on same board.
(e) All as per item No 2 here-in-before but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 amp socket .
(f) All as per item No 2 here-in-before but point wiring with 4 Sqmm single core copper cable for phase and neutral and earth continuity wire with 4 Sqmm
S&F Modular box with MCB 25 Amp complete with metal box and 3 pin top plug for AC complete all as specified and directed. Note :- Rates are inclusive of cutting/chases for mounting Modular metal box concealed in wall and making good to the disturbed surfaces with OBD/colour wash/white wash and wall putty where ever required
Supply & Fixing switch modular single pole, one way 6 Amp, 01 module. complete all as specified and directed
M&L modular switch piano flush type 6 Amp two way ISI marked. complete all as specified and directed
Supply & Fixing modular socket 6 Amp-2/3 pin combined, 2 module. complete all as specified and directed
Supply & Fixing switch modular single pole, one way 16 Amp, 01 module. complete all as specified and directed
Supply & Fixing modular socket 6/16 Amp-2/3 pin combined, 2 module. complete all as specified and directed
S&F ceiling rose surfaces bakelite minimum size 65x50mm with two/ three terminals complete all as specified and directed
S&F modular bell push flush type 5 Amps ISI marked complete all as specified and directed
S&F in replacement bell ding dong AC 230 V, single pole, ISI marked.complete all as specified and directed
S&F modular ceiling fan regulator step type 120 W-2. complete all as specified and directed
S & F of LED of Integrated Aluminium Batten T5 20 watt - 4 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type complete with including fliexble wire all as specified and directed in replacement of old unsv existing 36 Watt tube light fitting with Make Bajaj Cat Part No-BCLAB 20W WH LED P/ Crompton Cat Part No- LDL-20-CDL / Wipro Cat Part No-LL20-281-XXX-65AL1
S&F in replacement LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete with Make- Havells Cat Part No – HEXAFT10WLED857SSYMBOPC / Crompton Cat Part No- LBHE-10-CDL / Wipro Cat Part No- WP1099
Supply and fixing in replacement surface mounted round shaped LED downlight with durable housing with Al heat shrink with diffuser to give glare free light 12 watt LED 6000K/6500K lamp type from ceiling of stairs/common areas, complete all as directed. Make : Bajaj Cat Part No-BGSLO12W6000K / Wipro Cat Part No-WP1076 / Crompton Cat Part No – LCDSPLN-R-12-CDL.
S & F LED Integrated with Aluminium Batten T5 10 watt - 2 Ft White, indoor decorative PVC extruded T5 LED battern -integrated type as fixing for mirror light complete with including flexible wire all as specified and directed in replacement of old unserviceable existing 15 Watt CFL light fitting complete all as specified and directed. Make- Bajaj Cat Part No-BCLSB10 WH / Crompton Cat Part No-LCTLN-10-CDL / Havells Cat Part No-ENDURALINEARNEOBS10WLED865SPCWH
S&F in replacement of LED Building security light fitting 30 Watt including fabrication of GI bracket 40mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut, bolts, & washers etc and all as directed. Make – Crompton Cat Part No-LSTS-30-CDL-M / Havells Cat part No-ENDURAPEARLSL30WLED757SASYTOPCMP / Bajaj Cat Part No – BCLST30W LED
S & F LED RETROFIT LAMP of 12 Watt LED lamp for wall mounting fiiting\ Holder complete all as specified and directed
Supply and fix in replacement of BLDC (Bruishless Direct Current) ceiling fan of 1200mm sweep, not less than 350 RPM, not less than Air Delivery 215 cfm, Voltage 220V, high air follow with with silence operation, having full copper motor & ribbed 3 Nos A/M blades. The BLDC motor fan shall have 100% rust-free blade. the fan shall have BEE 5 star rating and compliant with IS-374 and making ncessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan complete all as specified & directed (Note : Existing fan to be deposited in MES yard)
S & F metal body exhaust fan heavy duty 300 mm sweep, 230 Volts, single phase1400 RPM with copper wound and louvers including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan all as per site requirement complete all as specified and directed
Supply and fix wall fan Airboll Hi-Speed of 450mm with economy range high speed having full copper motor & high quality plastic (acrylic) blades for higher air delivery, powder coating provides longer life complete with accessories 230 Volts including necessary electric connection of suitable PVC copper wire from ceiling rose or switch board to wall fan complete all as specified & directed Make : Havells of Model No : Airboll Hi-Speed Wall Fan or equivalent make of Philips/Bajaj/Almonard
M&L for opening of hole through out the wall as suitable for exhaust fan of size 250mm & 300mm sweep and fixing of nut-bolts with 4" anchor fastner of suitable size and making food the disturbed surface and all as per site requirement. Note : The rates are inclusive in respect of under this item as above hole opening civil work with MS faster bolt of 8mm dia and 100mm (minimum) long for fixing of exhaust fan and MS fastner clamps strip 38 mm wide and 5mm thick (min) to hold exhaust fan complete all as directed
Supply and fix MCB DB SPN 8 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 200 Amp rated bus bar complete all as directed.
M&L in replacement MCB SPN 'C' curve 63 Amps 240 Volts, 10 KA complete all as directed
M&L in replacement MCB SP 'C' curve 06 to 40 Amps 240 Volts complete all as directed
M&L for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as directed
M&L for submain wiring of two runs of 10 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn through PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as directed Note : The rates are inclusive of Cutting / chasing and making good to disturbed surface with CM 1: 3 and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash /white wash complete.
Supply & Fixing in replacement of sheet metal enclouser MCCB DB IP 20 double door bus bar neutral link earth bar and din rail VTPN 6 way. Make :-Indo Asian Cat Part No 811894 or equivalent in Legrand/ABB
Supply & Fixing in replacement of on distribution board MCCB 250 Amps, 3 Pole, 415 Volts with 36 kA including electrical connection with bus bar or incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and directed
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing as directed
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as directed
S&F in replacement of AC single phase static energy meter of accuracy Class 1.0, 240 volts, 50 Hz with polycarbonate body and backlight LCD display of rating 10-60 Amps measure and display KWH, V, Current 1, KW, p.f. last month history of KWH, MD in KW with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box all as specified and directed Make :- HPL/L&T/Secure (Note: Contractor will ensure that meter is working accurately to the satisfaction of Engr-in-Charge).
Supply & fixing of water storage heater 5 star rating glass line coating of capacity 25 ltr, vertical type, AC, Single Phase electric, 230 Volt, complete with heating element, thermostat, 3 core lead, Plug top, safety valve, including electric and water connection with suitable nut, bolts & washers and making good to disturbed surface complete all as specified and directed “Make- Crompton / Bajaj /Usha / AoSmith /Havell’s
S&F 15mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including connections complete all as directed.
S&F bib tap 15mm bore of cast copper alloy (heavy duty) CP fancy type scrwed to iron pipe and fixed complete all as directed
S&F Angle Valve of 15 mm dia cast copper alloy (heavy duty) CP fancy type screwed for iron pipe and fixed complete all as directed
S&F PVC connection with brass nipple 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25 ltrs capacity of geyser as hot and cold water connection complete all as specified and directed
S&F decorative wall light mounting suitable for LED lamp upto 12 Watt completed all connections all as specified and directed. Make :- Havells Cat Part No –LHF0E1TZ10014/ Halonix Cat Part – HLWB-01-B22/Philips model – Comet.
S&F MCB SP ‘C’ Curve 63 Amps, 10kA, 240 Volts all as specified and directed
S&F in replacement Sheet metal enclosure of size 300 x 250 x 150 mm suitable for mounting single phase meter fabricated from CRCA sheet with anti corrosive dust and vermin proof. Note:- The meter cover shall have a transparent window. The window shall be of transparent, high grade UV stabilized engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover all as specified and directed
Description of Work / Item(s)
Amount
Supply & install ,testing and commissioning of transformer as per IS : 1180 part - I, EEL-2 step down, copper Cu 99.9% purity, electrolytic grade wound 11KV/433 Volts (at no load) AC 3 phase 50 Hz 400 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondary side (LV) and having taping at +5% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 50 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree Celsius transformer shall be of BOLTLESS core design.
Transformer shall be double wound, core type with low loss, non-ageing, high permeability CRGO prime core grade M-3/ M-OH / ZDKH /TCH grade, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076 and as per IS-1180 part - I of 2014 marked. Flux Density at rated voltage and rated frequency should be 1.688 T the transformer shall be designed as per CBIP manual 317 for over-fluxing withstand capacity of 110% continuous, 125% for 1 minute and 140% for 5 seconds. and over loading capacity of transformer shall be as per 6600 , Noise level as per NEMA TR1, with class A insulation, Tank pressure, Vacuum withstand capability & minimum clearances as per CBIP manual, No Load Current within 1% to 2% of Full load current Transformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with Energy Efficiency Level - 2 and shall comprise of the following accessories :- Note: (i) OEM of transformer should be BIS and BEE certified for all the ratings of the transformer that are to be submitted. (ii) Rate Quoted shall include the cost of Earth work and Foundation for installation as per OEM Recommendation
(a) One cable box for HT connection, three Nos procelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers
(b) One cable box on LT side (secondary side) consisting of connection through Bus Bar Trunking/cable termination.
(c) Oil conservatror with filter type drain valve and oil level guage
(d) De-hydrating breather with first fill fo dehydrating agent (Sillica gel).
(e) Explosive vent, Thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain soild cast steel detachable rollers.
(f) Oil temparature meter and winding temparature meter having range 0-120 degree celsius.
(g) Two earthing terminals on tank cover to facilitate fixing for earth stirp earthing of body.
(h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(k) First filling of new and unused transformer oil, filtered and tested upto 60 KV dielectric strength at 2.5 mm air gap between testing electrodes.
(l) Lifting lugs
(m) Pressure release valve.
(n) Foundation as per manufacturers recommendations.
l) hv side 3 nos surge arresters
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5core complete all as specified and directed
Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out complete all as specified and directed
Returning, filling incl spreading, levelling, watering and well ramming layers not exc 25 M for cable laying complete all as specified and directed
Removing/excavated soil to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point all as specified and directed.
Supply and filling of river sand in layers for cable trenches complete all as specified and directed
S&Laying sub class B bricks size 250x125x75 mm having minimum compressive strenth 75mm Kg/sqm laid in trenches for cable protection etc complete all as directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed
Taking out carefully LT cable of size 120 sqmm to 150 Sqmm 3.5 core from trench/pole complete all as specified and directed
Dismantling the existing corroded/damaged LT pannel/feeder pillar boxes of any size by disconnecting all the incoming / out going cables, sealing the cable ends, disconnecting incoming / out going MCCB's from bus bar chamber and removing all the items complete all as specified and directed
Supply, installing, testing and commissioning in replacement outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Incomer of the panel having ACB 4 pole , 630 Amp , 50 kA , 415 Volt AC Horizontal draw out type motorized (EDO) , front operated with Microprocessor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No, Digital Multifunction Meter (Accuracy class 0.5) with LCD display for measuring of current, voltage, power, power-factor, energy parameters etc and Aluminium bus bar of rating 1000 Amp, 4 pole , mounted on SMC insulator- set of four. Outgoing of the panel having following : (i) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 25 KA with microprocessor release - 06 Nos. All outgoing busbar shall be of current carrying capacity not less than the rated current of MCCBs. All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands
Supply, laying trough trenches / walls / ceilings and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core from LT panel to VTPN DB of Each Floor (4 floors) complete all as specified and Directed.
Earthing complete with GI plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 25 x4mm (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron electric arc welding all joints all as specified and shown in electrical plate no 5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with PCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia medium grade for protection of earth electrode 20 mm dia for watering complete all as specified and directed and tested on completion
M/S Chhavi Constructions Co
A R construction
A R construction
A R construction
Bidder Name
A R construction
M/S Chhavi Constructions Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .