| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 CrAccepted-AOC | ₹18.9 Cr | L1 | Accepted-AOC Being lowest and reasonable tender |
| 2 | L2₹19.4 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹19.4 Cr | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹20.9 CrRejected-Finance | ₹20.9 Cr | L3 | Rejected-Finance Not being the lowest |
| 4 | L4₹26.2 CrRejected-Finance | ₹26.2 Cr | L4 | Rejected-Finance Not being the lowest |
Tender Value
₹19.5 Cr
EMD Value
₹13 L
Closing Date
22 Jul 2021, 6:00 pmClosed
Cheif Engineer (Navy) Mumbai
HQ Cheif Engineer (Navy) Mumbai, 26, Assaye Building, Colaba, Mumbai
PROVISION OF DEFENCE CIVILIAN MARRIED ACCOMMODATION (TYPE II) AT DEFENCE CIVILIAN RESIDENTIAL AREA(DCRA), GOA
2021_MES_416540_3
87869/E8
Open Tender
Civil Works
630 days
Vasco
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (P) Vasco
₹13 L
Yes
30 Jul 2021
11 Jun 2021
26 Jul 2021
11 Jun 2021
22 Jul 2021
8 Jul 2021
12 Jun 2021 - 18 Jun 2021
Amount
Total amount of Sch 'A' Part-I (BUILDINGS & STRUCTURES) brought forward from Serial Page No. 31
Total amount of Sch 'A' Part-II ( EXCAVATION , EARTH WORK, SITE CLEARANCE AND DEVELOPMENT) brought forward from Serial Page No. 34
Total amount of Sch 'A' Part-III (INTERNAL WATER SUPPLY) brought forward from Serial Page No.36
Total amount of Sch 'A' Part-IV ( INTERNAL ELECTRIFICATION ) brought forward from Serial Page No.39
Total amount of Sch 'A' Part-V ( SEWAGE DISPOSAL) Brought forward from Serial Page No.41
Total amount of Sch 'A' Part-VI ( AREA DRAINAGE )brought forward from Serial Page No. 43
Total amount of Sch 'A' Part-VII ( EXTERNAL WATER SUPPLY ) brought forward from Serial Page No.45
Total amount of Sch 'A' Part-VIII ( EXTERNAL ELECTRIFICATION ) brought forward from Serial Page No. 48
Total amount of Sch 'A' Part-IX ( LIGHTNING PROTECTION ) brought forward from Serial Page No.49
Total amount of Sch 'A' Part-X (LIFT )brought forward from Serial Page No.54 (R)
Total amount of Sch 'A' Part-XI ( FIRE FIGHTING ) ) brought forward from Serial Page No.57
Total amount of Sch 'A' Part-XII ( ROAD, PATH, CULVERT & HARD STANDING ) ) brought forward from Serial Page No.59
Total amount of Sch 'A' Part-XIII ( FENCING & GATE ) brought forward from Serial Page No. 61
Total amount of Sch 'A' Part-XIV ( DEMOLITION ) brought forward from Serial Page No. 64
Sch 'A' Part- XV - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
INTERNAL WATER SUPPLY :- S & F 15 mm dia CP brass angle valve with CP nuts and washers, CP brass wall flange with any other items complete including cutting and making good the wall whereever required all as specified & directed.
Supply and Fixing 100mm bore Sluice Valve class PN 1.60 complete all as specified and directed.
EXTERNAL WATER SUPPLY:- Supply install test and commissiong of centrifugal pump set , electric driven complete with all accessories suitable for pumping water 600 LPM discharge at 50 m head coupled with suitable size of electric motor AC 3 phase ,50Hz including supply and fixing the items, such as , necessary connection from starter to motor terminal using proper size of copper cable including ,connection of suction pipe from pump to foot valve, delivery pipe connected to the raising mains of the over head rservoir by means of suitable joints painting the suction and delivery pipe with super enamel paint over a coat of primer as per standared code of colour including MS base plate complete complete all as specified and directed.Note : Suction and delivery pipes shall be measured and paid under appropriate items ( main water supply pump for building)
Note - Energy Efficient Motors-Motors shall comply with following a. All permanently wired poly phase motors of 0.375kW or more serving the building and expected to operate more than 1500 hours per year and all permanently wired poly phase motors of 50kW or more serving the building and expected to operate more than 500 hours per year shall have a minimum acceptable nominal full load motor efficiency not less than IS 12615 for energy efficient motors b. Motors of horsepower differing from those listed in the table shall have efficiency greater than that of the next listed kW motor 0.64% c. Motor horse power rating shall not exceed 20% of the calculated maximum load being served,d. Motor nameplate shall list the nominal full- load motor efficiencies and the full load power factor e. Motor users should insist on proper rewinding practices for any rewound motors. If the proper rewinding practice can not be assured, the damaged motor should be replaced with a new, efficient one rather than suffer the significant efficiency penalty associated with typical rewind practices f. Certificates shall be obtained and kept on record indicating the motor efficiency. Whenever a motor is rewound, Appropriate measures shall be taken so that the core characteristics of the motor is not lost due to thermal and mechanical stress during removal of damaged parts after rewinding a new efficiency test shall be performed and a similar record shall be maintained
Supply and fix Foot Valve conforming to IS 4038, 80 mm dia. Make - kirloskar, L&T
Supply and fix CI sluice valve of 80 mm dia both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed MAKE : Kirloskar/Upadhyay/L&T Ext WS 2
Supply and fix CI sluice valve of 100 mm dia both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed MAKE Kirloskar/Upadhyay/L&T [ Ext WS 2 + FF 3 nos]
Cutting the existing DI/CI pipe of 200/100 mm dia and reducing to required length in position for inserting new Tees, branches etc. including fitting excavation, refilling, ramming complete
Supply and lay pipe ductile Iron , S/S including specials, Class “K9” , 100 mm dia including specials. (For re-route and tapping point to sump)
Supply and laid spigot/flanged/ socketed DI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 80mm to 300mm dia.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, LT panel board ,made out of 2 mm thick CRCA Sheet single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HAGGER/SCHNEIDER ( main water supply pump )
INCOMING:-
(a) MCCB with thermal magnetic release,MCCB 4 pole, 40 Amps, 50 Hz, 415 Volt, 25 KA - 1 No
(b) Busbar TPN of size 100 apms - 1 set
OUTGOINGS:-
(a) MCCB TP 32 Amps, , 50 Hz, 415 Volts, 25 KA -02 Nos (pump)
(b)Automatic Starter delta starter for 12.5 HP pump -02 Nos
(e) Phase Indicating lamps (RYB) LED type -03 Nos
(f) Single phasing preventer -02 No
Construction of brick masonry valve chamber of size 900x900x900 mm (internal dia) suitable for 150 mm dia sluice valve with necessary earth work excavation plain cement concrete (1:4:8) using 40 mm graded stone aggregate, 75 mm thick in cement mortar (1:6), 15 mm thick plastering in CM ( 1:6) inter nally including flooring and externally rep to 15 mm below ground level plain cement concrete (1:4:8 ) type B1 using 20 mm graded stone aggregate in coping, MS sheet cover made out of 3 mm thick MS sheet flat iron frame and bracing with locking arrangement ,applying two coats of synthetic enamel paint including dismantling removing the existing damaged chamber completely ,removal of debris to a distance not exceeding 50 mtr & depositing where as directed by Engr - in- charge
Supply, Installation, Testing and Commissioning of Float type Point Level Sensor and elecronicLevel indicator in digital/anologe showing at least 4 level duly wired and connected with the following specifications; senser Type: Magnetic Magnet: Ring type Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon Make: RECKTRONIC DEVICES AND SYSTEMS / TECHTROL / CRISTAL/UNIVERSAL
INTERNAL ELECTRIC SUPPLY
S &F Lamp holder insulated body with back plate and Including LED lamp 9 watt for angle holder all as per specified
S &F modular Box sheet metal with socket 3 pin, suitable for 20 Amps flush type universal including 16 amp c series MCB protected.(For Geyser & 1 Power point in m bedroom)
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x18/20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make-WIPRO /HAVELLS /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extrudedalluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ,2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc. make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
S & F LED Security/Street light fittings 25 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc. Make- WIPRO /HAVELLS /JAQUAR /PHILLIPS
Fabricate,supply & fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting
S&F Fresh air Exhaust fan of size 230 mm/225 mm sweep pvc body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make Make , - Havells/Crompton Greaves/Bajaj
S&F Energy efficient BEE five star rated ceiling fan, 1400 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. -Make : Crompton Greaves/ Bajaj/Orient
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed. -Make : Crompton Greaves/ Bajaj/Orient
MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBTPE004DD/ LEGRAND CAT NO-607715/ / schneider/ ABB
MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail ,230 Volts SPN with 12 way Double door , IP-43-IK09 protection grade,L&T CAT NO-DBSPN008DD/ LEGRAND CAT NO-607711/ / schneider/ ABB
MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 4 way Double door IP-43-IK09 protection grade
MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 32 Amps ( for commen lighting DB)
MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
S & F ISI marked RCBO 32 A, 30 mA, 230 V DP for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed.
S & F ISI marked RCBO 16 A, 10 mA, 230 V DP for AC applications, conforming to IS 12640 (Part-2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters complete all as specified and directed.
Supply, Installation, test and Commissioning CPRI approved factory fabricated,Indoor type, LT Pannel Board made out of 2.00 mm thick CRCA Sheet dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Test-ing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HEGGER/SCHNEIDER (location - in meter Room)
(a) MCCB 320 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No. (incoming)
(b) MCB 63 A 10 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -10 No. (outgoing )
(e) Aluminum TPN bus bar 500 Amps - 01 Set
(h) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Supply and Installation of Smart Single Phase Meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Radio Frequency (RF) communication facility in Cyanconnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from prepaid billing software ( Note-elecronic energy meter to be fixed in clear polycarbonate acrylic cover BOX) MAKE: Secure, L&T, Schneider
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) [ Int Elect 4 + fire fighting 2 +Ext WS 4
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 32 x 6mm GI strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt,Earthing lead 32x6 up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) NOTE-: GI earth strip beyond 7.5 meter shall be measured and paid for separately under relevant item of schedule . [ Lightning protection -8 +Ext WS2 + Ext ES 16 +DG SET 6
Earthing complete with copper earth plate electrode 600mm x600 mm x 3.15mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth 20x3 mm copper strip by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm bronze flat including earthing pit , charcoal common salt,Earthing lead 20x3 up to 7.5m long, 20mm dia medium grade GI watering pipe, GI Protection pipe 40 mm dia up to 7.5 m long ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2014 (part-I) NOTE-: Copper earth strip beyond 7.5 meter shall be measured and paid for separately under relevant item of schedule .
Supply and lay Co-Axial Cable RG-6 dia drawn through conduit
S &F TV Socket
S&F Exhaust fan of size 225mm /230 mm sweep metal body complete with and louvers connecting up including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose to exhaust fan. Make - Havells Cat No Ventilair DB Neo grey or equivalent in Crompton Greaves/Bajaj
Supply and Installation of Data Concentrator Units (DCU) with the following specifications: • Data Concentrator Unit (DCU) compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with the static energy Meter in the corresponding frequency band and with the data server through GPRS and shall have minimum data transfer rate of 9600 bps, internal memory to store data of upto 200 modules (GSM chips cost as per requirement is deemed to be included) Make: Secure, L&T, Schneider or authorized channel partner/vendor of the company
Configuration of Cloud Hosted multi user web based Software for the meters with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the following data: (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency (b) Monthly and quarterly billing survey data for cumulative energy and max demand (ii) Prepaid Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would be available in both Prepaid and Postpaid Billing options. The billing module would also have a payment solution where it different modes of payment would be recorded. (iii) Occupation and Vacation Module: The system would support occupation / vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events.
(iv) Customer Portal The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. The clients would also have Android and iOS mobile apps to view energy, bill and make online payments. (v) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vi) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (vii) Meter Master Data The system would support meter master data repository. The system would support meter replacement process. (viii) Excel Export The system would support export of metering and billing data in excel format. Make: Innologix, SAP, Oracle
FENCING : Supply abnd fix PVC coated MS galvanised chain link fencing of size 75x75mm of any type of standar, rail straining bolts etc including provision of bindingg wire.
LIFT : Supply, install and commissioning of factory made vermin proof LT panel indoor cubical type of suitable size made out of 2.0 mm thick MS Sheet and MS angle section 50 x 50 x 6 mm on PCC 1:2:4 type B-1, plateform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasket ‘U’ type for natural flow of air, complete dust and vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factory made (Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 microns including making connections and general construction confirming to IS -8623 of 1993 comprising of the following complete all as specified and directed.(Main LIFT Panel) :-
Incomming
a) Copper bus bar 150 Amps TPN fixed on insulator not less than 1.0 mtr long bus bar -1 set
b) Incoming MCCB, 100 Amps, 4 pole, 415 Volts AC having rupturing capacity 25 KA - 01 No
Outgoings
(a) MCB, 40 Amps, 3 pole, 415 Volts AC having rupturing capacity 10 KA - 02 No
(b) MCB, 32 Amps, 3pole, 415 Volts AC having rupturing capacity 10 KA - 02 No
(e) Indicator Lamp LED type (R-Y-B) with holder-01 set of three.
FIRE FIGHTING
supply and fix suitable Air release valve of 100 mm dia, PN 1.6 including. necessary support and painting with two coats of enamel paint over a coat of primer etc. complete, for wet riser termination.
Supply, installation, testing & commissioning of fire brigade inlet unit 3-Way with necessary fitting 150mm dia fire brigade inlet for tank filling by fire brigade shall be four way with flanged gun metal instaneous male female inlet coupling connection for connection with fire brigade vehicles or tanker. The inlets skall be provided with ABS Quality by plastic blank caps with chain and arrangement for attaching the blank cap & chain to the fire brigade inlet as per specification.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT panel board ,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–Make of MCCB/MCB -LEGRAND/L&T/HAGER ( Fire fighting panel )
(a) Incoming MCCB 32 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider -01 No
(b) Aluminium Busbar TPN of size 100 apms - 1 set
OUTGOINGS:-
(a) MCCB 4 POLE 25 Amps,25 KA - 1 Nos
(b) DOL Starter for 15 HP Pump set-1 Nos
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
(g) Single phasing preventer -01 No
M & L for Low smoke Zero helogen flame retardent fire alaram cable 2 core, 1.5 mm² copper conductor confirming to BS7629-I , BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performance silicon rubber with electrostatic screen of aluminium fire barrierType LT53 outer sheathconfirming to BS 7655 , red in colourdrawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply and fix double wall corrugated, High Density Polymer Ethyl pipe for laying of Electric cable of size 160 mm outer dia and 135 mm inner dia with IS : 14930 (Part 2) : 2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as speicified and directed by Engineer-in-Charge.. Make - Dura line/Tijaria/TELEREX. (For cable 3.5x630 sqmm,3.5x400 sqmm)
Supply and fix double wall corrugated, High Density Polymer Ethyl pipe for layinng of Electric cable of size 120 mm outer dia and 103 mm inner dia with IS : 14930 (Part 2) : 2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as speicified and directed by Engineer-in-Charge.. Make - Dura line/Tijaria/TELEREX. (For cable 3x95 sqmm, )
Supply and fix double wall corrugated, High Density Polymer Ethyl pipe for layinng of Electric cable of size 63 mm outer dia and 50 mm inner dia with IS : 14930 (Part 2) : 2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as speicified and directed by Engineer-in-Charge.. Make - Dura line/Tijaria/TELEREX. (For cable 3.5x35 sqmm, 4x25 sqmm , 4x16 sqmm,4x10 sqmm)
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, OUTdoor type , double door, APFC capacitor bank Panel Board of size as recommended by manufactrer 70 KVAR with 6 steps (25+12.5+12.5+10+5+5) WITH MD-XL CAPACITOR AND MCCB AS INCOMER Automatic Power Factor Correction panel , made out of 3.15 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System,The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprosing of following. Make of pannel L&T/ SCHNEIDER/ABB
EXTERNAL ELECTRIC SUPPLY
INCOMER
MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T -01no
ROM+SPDR - 1 no
Auxiliary 1 c/o +TAC 1 c/o- 1 no
OUTGOING CAPACITOR FEEDERS : -
25 KVAr Capacitor feeder comprising of:- ( 1 Nos. )
80A, BUSSMANN FUSE 80ET,-3 nos
Thyristor switching module 25kVAR, 440V , TSM,LTTSM-1 nos
7% Detuned Aluminium Reactor 25KVAr 440V-1 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 30 kVAr,sutable for 480V , LTXL - 1 NOS
Push Button ON/OFF -2nos
Indicating lamps 2 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 1
6A DP MCB , C CURVE 1 NOS
12.5 KVAr Capacitor feeder comprising of:- ( 2 Nos. )
40A, BUSSMANN FUSE- 6 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM - 2 NOS
7% Detuned Aluminium Reactor 12.5KVAr 440V LTAL,CAT NO-0712B2- 2 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 15 kVAr,sutable for 480V - 2 NOS
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
10 KVAr Capacitor feeder comprising of:- ( 1 Nos. )
40A, BUSSMANN FUSE- 3 NOS
Thyristor switching module 25kVAR, 440V,TSM,LTTSM -1 NOS
7% Detuned Aluminium Reactor 10 KVAr 440V LTAL,CAT NO-0712B2- 1 NOS
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 12.5 kVAr,sutable for 480V - 1 NOS
Push Button ON/OFF -2nos
Indicating lamps 2 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 1
6A DP MCB , C CURVE 1NOS
5 KVAr Capacitor feeder comprising of:- (2 Nos. )
16A, BUSSMANN FUSE 6 nos
Thyristor switching module 10kVAR, 440V,TSM,LTTSM - 2nos
7% Detuned Aluminium Reactor 5 KVAr 440V,LTAL,CAT NO-0712B2-2 no
Ultra heavy duty capacior LTXL , BOX type oil Filled Capacitor bank 7.5 kVAr,sutable for 480V ,LTXL- 2nos
Push Button ON/OFF -4nos
Indicating lamps 4 NOS
Auxiliary Contactor {2NO+2NC} 24V DC Coil Voltage MXO- 2
6A DP MCB , C CURVE 2 NOS
Incomer Metering
APFC relay 6 stage {BLR CM – 06T MB } -1 NO [230/ 110 V, 1/5A, 50 Hz] [Transistor output + Single CT sensing + RS 485 MODBUS]
Digital Voltmeter (3Ph, Class 1) -1 NO
Digital Ameter (3Ph, Class 1, 5A) -1 NO
Metering CT --/5A, Class-1- 3 NOS
SMPS 5A, Input 230V AC Output 24V DC -1 NO
ON Delay Timer 0-10 Sec.,Coil 24V DC -1 NO
Auxiliary Contactor {4NO} with 24V DC}-3 NOS
Indicating Lamp(R,Y,B)-3 NOS
6A SP MCB-3 NOS
6A DP MCB
6A FP MCB -1 NO
8" {EBM NADI} Fan -1 NO
Supply, install, testing and commisioning of Distribution transformer mounted on massoniry platform stepdown , 11KV/0.433KV , Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest ammanmendts , Outdoor type double opper wound suitable for 50 Hz system of capacity 315 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in steP of 2.5 %. Losses should be confined to the limits specified as follows: :maximum allowable losses at full load (100 % ) & Half Load ( 50 % )shall not be exceeded 1.12 % & 0.79 % Respectivly as per GRlHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028 and comprising with the standerd fittings/Technical specifications mentioned below. Make -M/s Rajasthan transformer & switch gear ltd / Indian Transformer Electricals, Gurgaon / PME/ITL/Voltamp
(a) Lifting lug for transformer and tank.
(b) Earthing terminal rating and diagram plate.
(c ) Air release device.
(d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve.
(f) Conservator tank with oil level indicator
(g) Silica jel breather
(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.
(k) Type of connection Delta/Star
(l) Type of cooling: Oil and Natural Air.
(m) Vector group:DYN 11.
(n) Temperature rise over an ambient of 50 °C maximum.
(o) Cable end box on both side for HT/LT cables of suitable size.
(p) Provision of thermometer with pocket.
(q) Provision of oil and winding temperature gauge.
Supply and fix cable route indicator made of round CI disc embossed HT / LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.
Supply and fix aviation obstruction light 10W of LED type twin with doom and other fixing accessories. (Make : Bajaj/Crompton Greaves/Philips)
S&F energy saving and environmental friendly long life LEd street light 35 W made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having IP65 protection and impact resistance of IK07 with 10KV Built-in surge Protection device. (Make : Bajaj/Crompton Greaves/Philips)
Supply and fix bracket made out of 40mm dia GI light grade tubing not less than 1.5mtr long bent to shape 120 deg including pole clamps (2no) made out of 30x5 mm MS flat, and nut bolts and washers etc all as directed
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, Aluminium busbar of capacity 600 Amps, out door cubical type floor mounted factory made double door dust, CPRI approved and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings. (Main Panel)
INCOMING:-
(a) MCCB with thermal magnatic release, 4 pole, 630 Amp, 50 Hz, 415 Volt, 36 KA - 1 No (Incoming)
(b) Aluminium TPN Busbar 800 Amps - 1 Set
OUTGOINGS:-
(a) MCCB, 3P, 200 Amps, 50 Hz, 415 Volts, 36 KA -02 Nos (APFC & spare)
(b) MCCB, 3P, 400 Amps, 50 Hz, 415 Volts, 36 KA -01 Nos (Bldg panl)
(c) MCCB, 3P, 125 Amps, 50 Hz, 415 Volts, 36 KA -01 Nos(AMF panel)
Supply install test and commission LT Panel board, CPRI approved, TPN 415 Volts, 50 Hz, Aluminium busbar of capacity 600 Amps, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings :- (DG panel)
INCOMING:-
(a) MCCB with thermal magnitic release, 4 pole, 125 Amps, 50 Hz, 415 Volt, 35 KA - 1 No
(b) Aluminium TPN Busbar 200 Amps - 1 Set
OUTGOINGS:-
(a) MCCB, 3 pole, 100 Amps, 50 Hz, 415 Volts, 36 KA -01 No (lift Panel)
(b) MCCB, 3 pole, 32 Amps, 50 Hz, 415 Volts, 36 KA -04 No (PH , FF Panel , commen lighting & spare)
(c) MCB SPN 6A -01 No. (Aviation Light)
(d) MCCB, 3 pole, 16 Amps, 50 Hz, 415 Volts, 25 KA -02 No (ST light)
(e) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T cat no- T2 DD T7/MDS/GIC - 1 no
(f )Power contactor ML-3 , 3 pole rating not less than 40 A with 230 coil make L&T/SEIMENS - 1 no. (g ) MCB SPN 6 amps-1 no.
Supply and fix M & L Hot dip galvanised Iron octagonal pole of height 6 mtrs minimum galavnising of 70 microns, top 70 mm , bottom 130 mm and 3 mm sheet thickness in single section without any weld joints with square plate of minimum dimensions 225x225x12 mm foundation bolts, single arm GI bracket of 900x1000 mm for mounting the light fitting at an angle of 120 degree,backelite sheet with one 6 A SP MCB and 16 mm stud type connectors -04 nos inside the pole at the door opening for cable connections,common template s minimum 01 for each 15 poles all fixed complete with foundation bolt of size M24 x700mm including necessary earth work, PCC foundation as per manufacturers recommendations and specifications all as directed Mast and pole shaft shall be be as per BSEN 10025,IS 5986, ASTM A572 , Foundation as per manufacturers instructions Galvanization as per IS-4759/2629 Make of pole- Bajaj / Jindal /Crompton/Shubham-
DG SET
(a) Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 62.5 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz supply, 1500RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following.
(b)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. Make of engine: Kirloskar / Ashok leyland / Cummins / Greaves, Make of Alternator: Kirloskar /Stamford / Crompten / Jyoti
(a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator.
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 24V Battery. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-12 volts(1x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.
(c) Alternator: Suitable rated 62.5 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make: stampford/crompten/kirloskar/ Jyoti
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 63 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(f) AMF control circuit with 4 pole MCCB 125 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
LIFT: Comprehensive maintenance and repairs of fully automatic electrically operated passenger lifts of any Make and installed capacity of 08passengers -2 nos and 13 passengers 1 no to serve G+9 floors with AC variable voltage & variable frequency (VVVF drive) complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic centre opening doors wth VVVF door drive (electric motor driven mechanism), sliding stainless steel door automatic rescue device (ARD) system , 3D infra red sensor in full height of door) and built in announcing system without hand set 04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 60 months ( including defect liability period of 24 months ) for all days including holidays etc after expiry of defects liability period as shown below and all as specified and dierected to GE. Note : (i)Contractor shall carryout comprehensive maintenance (routine, daily , weekly , monthly , quarterly , half yearly, yearly ) as per attached Performa and maintain all the lifts in serviceable condition 24 hrs X 365 days without any extra cost .(ii) WO for maint of lifts shall be issued by GE after completion of defect liability period for every consequent year for total period of 3 years.(ii) Final bill shall be paid after certified completion of work for each WO seperately (iii ) The Contractor shall conclude an MOU with the lift manufacturer to provide comprehensive AMC of the lift for five years from the date of commissioning/ completion. The copy of MOU shall be submitted to GE for record, giving out complete terms and conditions of the AMC before completion is issued by GE.
(iv) In case of non function of Lift even after 24 hours after the defect is noticed or notified either in writing or through a social media message by GE or his rep, a penal recovery @ Rs 3000 per day shall be effected (v) Any defect in to a Motor ,ARD ,OLD,door drive , senser , limit switch ,Rope/belt ,Control Panel ,car panel with indicators, air circulating fan, Led lights & Misc Item etc shall be considered as outstanding defect & Penal charge will be applicable as above in Note (iv )
(a)1st year after expiry of defect liability period ( 03 Nos of Lift )
(b) 2nd year expiry of defect liability period ( 03 Nos of Lift )
(c) 3rd year after expiry of defect liability period ( 03 Nos of Lift )
ARBORICULTURE
Supply, stacking and laying spreading in layers n exc 25cm thick with approved good earth as approved by GE obtained outside of MD land.
Supply, stacking and laying including spreading to a uniform thickness of 10cm with approved sweet soil as approved by GE obtained outside of MD land.
Supply, stacking and laying including manure mix sweet soil to a uniform thickness of 50mm including troting the soil with insecticides/antitermite powder/solution (approx 1.5 kg of dust and 25ml of duresban per 20 cum of mixed soil) and spreading, levelling, shapping etc all as specified.
Supply and planting/laying Mexican grass for lawn including watering daily manuaring and maintaining upto a period of 90 days from the date of completion of plantation till the grass forms a thick lawn, free from weeds & fit for mowing
Supplying and planting of best quality hedge plants including watering daily manuaring and maintaining upto a period of 90 days from the date of completion of planting.
Supplying and planting of best quality red palms including watering daily manuaring and maintaining upto a period of 90 days or more from the date of completion of planting.
Supplying and planting of best quality flowers plants including watering daily manuaring and maintaining upto a minimum period of 90 days or more from the date of completion of planting
(a) Ixora
(b) Hibiscus
(c ) Lantana
SOOD ASSOCIATES PVT LTD
JAI CONSTRUCTION CO.
Beejay Associates Contracts Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid