Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC 1ST FLOOR PRABHA SHOPPING COMPLEX OLD PAHARGAON DOLLYGUNJ PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 UDYAM AN 01 0000143 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Being the Lowest tenderer | |
| 2 | L2₹19.1 L+₹1.5 L (8.32%)Rejected-Finance SHOP NO 6 BENGALI CLUB MIDDLE POINT SRI VIJAYA PURAM 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance Quoted amount is higher than the L1 tenderer | |
| 3 | L3₹19.9 L+₹2.2 L (12.6%)Rejected-Finance GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Quoted amount is higher than the L1 tenderer | |
| 4 | L4₹20.7 L+₹3.1 L (17.7%)Rejected-Finance 290 NEW PLOT JAWAHAR NAGAR JAMMU JAMMU JAMMU KASHMIR 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L4 | Rejected-Finance Quoted amount is higher than the L1 tenderer |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
29 Apr 2024, 6:00 pmClosed
Garrison Engineer (P) North
GE(P) North, Port Blair, Minniebay,
REPAIR MAINTENANCE OF EM INSTALLATION LT PANELS WATER SUPPLY INSTALLATION UG CABLE PIPE LINES STREET LIGHTS DG SET INTERNAL ELECTRIFICATION ALONG WITH FITTINGS AND FIXTURES COOLING APPLIANCES AND ALLIED SERVICES AT HUT BAY
2024_MES_648697_1
8167
Open Tender
Civil Works
Item Wise
270 days
GE (P) North, Port Blair (Hut Bay
As per Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (P) North
₹46,000
Yes
25 Sept 2024
30 Mar 2024
6 May 2024
30 Mar 2024
29 Apr 2024
15 Apr 2024
30 Mar 2024 - 8 Apr 2024
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in any type of soil complete all as specified and directed.
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil complete all as specified and directed.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point complete all as specified and directed.
M&L for sand cushioning to under ground cable in layers ( 8 cm before laying the cable and 15 cm after laying the cable and punned into 18 cm thickness) in trenches for cable protection complete all as specified and directed.
Supply and laying precast concrete cable cover slab class LV type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
Laying only precast concrete cable cover class LV type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. Note :- Serviceable covers removed shall be relayed under this item.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 6 Sqmm 2 Core in trenches/along the wall/ including making all connections complete with lugs, suitable cable glands as required at site complete all as specified and directed.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 10 Sqmm 4 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site complete all as specified and directed.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 16 Sqmm 4 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site complete all as specified and directed.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 35 Sqmm 3.5 Core in trenches/along the wall/ including making all connections complete with lugs, suitable cable glands complete all as specified and directed.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 50 Sqmm 3.5 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site complete all as specified and directed.
Supply & Lay XLPE insulated, heavy duty 11000 volt grade electric HT UG cable with multistranded aluminium conductor of size 95 Sqmm 3 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site complete all as specified and directed.
S & F in repairs out door heat shrink type end termination cable jointing kit for 11 KV (Earthed) grade cable 95 Sqmm complete all as specified and directed.
S & F in repairs out door heat shrink type stragight through cable jointing kit for 11 KV (Earthed) grade cable 95 Sqmm complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth complete all as specified and directed.
M&L for Straight through heat shrink joint complete type LT XLPE cable upto 1.1 KV complete with all accessories for 4 Core 10/16/25 Sq mm cable complete all as specified and directed.NOTE: Excavation & Earth work shall be mesured & paid sepreately under relevent Item of this Schedule.
All as per Item No 16 here in before but of size 35/50 Sqmm x 3 1/2 Core complete all as specified and directed.
All as per Item No 16 here in before but of size 70/95 Sqmm x 3 1/2 Core complete all as specified and directed.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting complete all as specified and directed.
Taking down old unserviceable street light fittings from the street light poles and replacement of burnt/worn out accessories and refixing the same in existing position including testing after repair complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix in replacement FRP looping box of size 140 X 140 X 95 mm or nearest size complete all as specified and directed.
Supply and fix in replacement FRP looping box of size 103 X 103 X 73 mm or nearest size complete all as specified and directed.
Supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade including taking down old unserviceable cable complete all as specified and directed.
M&L for fixing, testing of contactor ML-2, 3pole, 415 volt coil, 230 volt complete as in panel including removing of old unserviceable conductor complete all as specified and directed.
M&L for repair DIN type astronomical programmable street light timer with current rating 16 amps complete all as specified and directed.
Material & labour for opening cover of garden light checking connections, repacing of lamps LED tye 5 Watts, 230 volt suitable for garden light fitting complete all as specified and directed.
M&L for filtration and dehydration of transformer oil using filtertion plant to remove moisture and carbon contents to achieve dielectric strength of oil not less than 50KV in 2.5 mm gap, Oil samples of each transformer are to be tested before and after filtration test, results to be recorded on a printed format and also painting the date of test on the equipment with synthetic enamel paint all as specified and directed and also including disconnecting the HT and LT cables and cleaning the bus bar surfaces and reconnecting the cables by providing copper washers, bolts, nuts, replacing of silica gel breather etc all as specified and directed. Notes:- (i) Oil required for topping up for filtration will be measured and paid separately under respective item of BOQ . (ii) The quoted rates shall also be deemed to include for proper cleaning of the tank surfaces to make the same free from sludge etc. (iii) The rate is deemd to be inclusive of trasportation of Oil filteration machine to Hut Bay
Supply only and filling of Transformer insulation oil as per IS 335-1993 having die electric strength minimum 50 KV in 2.5 mm gap for topping up in transformer complete all as specified and directed.
Material and labour for scrapping of old paint from the exposed steel surfaces and applying two coats of Aluminium paint over a coat of Red oxide primer on 11 KV two pole structure including GOD & operating rod, including scrapping of old on PCC Pole and applying 2 coats of cement based paint, greasing & applying petroleum gelly to current carrying contacts etc, complete all as specified and directed.
Supply and fix in replacement of GI steel tubing light grade 40mm dia for laying in ground, along the pole in coping, road crossing etc for cable protection including necessary fittings , clamps for supports, etc complete all as specified and directed.
Supply and fix gun metal globe or gate valve of dia 25 mm with iron wheel head screwed both ends for iron pipe and fixing complete conforming to IS -778 with ISI mark grade-1 alongwith one no of union including taking down existing unservicable gate valve complete all as specified and directed
Supply and fix 25 mm dia ball valves high pressure PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and including fittings such as cockets and nipples etc including taking down existing unservicable ball valve complete all as specified and directed.
Supply and fix brass/PVC foot valve of 50 mm dia including making threading in suction pipes complete all as specified and directed.
M&L for taking down of centrifugal monoblock pump set of capacity 3 HP/5HP, servicing including dismantling/ opening of body, cleaning of body, replacing of bearing, gland packing etc, oiling, greasing, reassembling complete, painting and refixing complete all as specified and directed.
M&L for taking down of monoblock pump set of capacity 3 HP/ 5HP, re-winding of burnt winding overhauling inlcuding dismantling/ opening of body oiling, greasing, reassembling complete etc, and testing complete all as specified and directed.
Supplying and laying in repair of 25 mm dia CPVC pipes SDR 11 & including Plain CPVC SDR 11 fittings complete all as specified and directed.
Supplying and laying in repair of 50 mm dia CPVC pipes SDR 11 & including Plain CPVC SDR 11 fittings complete all as specified and directed.
Cleaning of underground sump of capacity 30000 ltrs by pumping out water from U/G sump by pump set as directed at site and taking out the remaining water at bottom by buckets manually as required, cleaning internal surfaces of the sump with wire brush, removing scale and dirt . Taking out soil, sand and mud settled at the bottom and finally cleaning with bleaching powder and marking date of cleaning on outslide with synthetic paint and size of letters not less than 100mm complete all as specified and directed.
Cleaning of underground sump of capacity 10000 ltrs by pumping out water from U/G sump by pump set as directed at site and taking out the remaining water at bottom by buckets manually as required, cleaning internal surfaces of the sump with wire brush, removing scale and dirt . Taking out soil, sand and mud settled at the bottom and finally cleaning with bleaching powder and marking date of cleaning on outslide with synthetic paint and size of letters not less than 100mm complete all as specified and directed.
Supply and fixing Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-forming to Fe.290.Gde-E-165PVC. (For Four Pole and Transformer fencing) complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type (For Fencing of Four pole structure and Transformer) complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:6 cement mortar complete all as specified and directed.
M&L for rendering 10 mm thick plaster on fair faces of brick work or concrete surfaces with cement of type 1:6 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Supply and lay 63mm graded stone aggregates inside GOD fencing, including leveling complete all as specified and directed.
Supply & fix MCCB 63 Amps Three Pole with breaking capacity 16 KA all as specified and directed.
Supply & fix MCCB 100 Amps Three Pole with breaking capacity 16 KA all as specified and directed.
Supply & fix MCCB 160 Amps Three Pole with breaking capacity 36 KA all as specified and directed.
Supply & fix MCCB 200 Amps Three Pole with breaking capacity 36 KA all as specified and directed.
Supply & fix pin type insulator for 11 KV Two Pole Structure complete all as specified and directed.
M&L in replacement of earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below GL) with top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanized earth strip 25X4 mm, earth plate surrounded from all sides by with 15cm thick packed layer of charcoal dust and common salt filling in alternate layer and electrode connection by using galvanized earth strip 25 X 4 mm connected by mean of bolt ,nut,chck nut & washer of galvanised iron, provision of 40 mm dia GI pipe medium grade for protection of gi strip & 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber,ms funnel ,wire gauge, 50mmthick RCC 1:2:4 TMT bars on both ways including necessary excavation in any type of soil rturning filling in removal of surplus soil to distance n.exc 50mrts complete all as shown in electrical plat no 3 of schedule part-1 2009 all as specified and directed and testing on completion
Supply & fix Gang operate device (GOD) of 11KV upto 400 amp complete all as specified and directed.
Supply & fix Expulsion fuse of 6.6KV upto 400 amp complete all as specified and directed.
M&L for carrying out routine checks of silent type DG Set of 160 KVA Stamford make alternator coupled with cummins engine, including checking of coolant level and top up of collant, draining out & supply and refilling of engine oil, replacing of fan belts, replaing of lube oil filter, fuel filter & fuel water seperator, checking of level of distelled water in battery & top up of water. Note:- Make of Engine oil, Coolant Oil, fan belt, filters etc shall be as per specified of OEM of DG Set and as approved by Engineer-in-Change.
M&L for carrying out routine checks of silent type DG Set of 125 KVA Stamford make alternator coupled with cummins engine, including checking of coolant level and top up of collant, draining out & supply and refilling of engine oil, replacing of fan belts, replaing of lube oil filter, fuel filter & fuel water seperator, checking of level of distelled water in battery & top up of water. Note:- Make of Engine oil, Coolant Oil, fan belt, filters etc shall be as per specified of OEM of DG Set and as approved by Engineer-in-Change.
M&L for carrying out routine checks of silent type DG Set of 10 KVA Kirloskar, including checkingof coolant level and top up of collant, replacing of fan belts, replaing of lube oil filter, fuel filter & fuel water seperator, checking of level of distelled water in battery & top up of water complete all as specified and directed. Note:- Make of Engine oil, Coolant Oil, fan belt, filters etc shall be as per specified of OEM of DG Set and as approved by Engineer-in-Change.
M&Lfor servicing of Split type Air conditioner 1.5 TR capacity of Voltas make inverter type AC of model 185VJZJR32, including taking down the out door and indoor units, takong out cooling coil and washing complete with water and caustic soda, cleaning of cooling coil, fan/blower drumand air filter with air blower, oiling greasing to mechanical parts and checking all connections of electrical parts, checking leakage in pipe line, arresting leakage in gas pipe line etc all as directed at site. Note - The quoted rate is deemed to be inclusive of disconnecting of copper tubing and brazing while refixing.
M&L for servicing of Split type Air conditioner 1 TR capacity of Voltas make inverter type AC of model 185VJZJR32, including taking down the out door and indoor units, takong out cooling coil and washing complete with water and caustic soda, cleaning of cooling coil, fan/blower drumand air filter with air blower, oiling greasing to mechanical parts and checking all connections of electrical parts, checking leakage in pipe line, arresting leakage in gas pipe line etc all as directed at site. Note - The quoted rate is deemed to be inclusive of disconnecting of copper tubing and brazing while refixing.
M&L for taking down of unserviceable capacitor 2.5 to 4 mfd for split AC 1.5 TR and supply & fix new capacitor of rating 2.5 to 4 mfd suitable for existing 1.5 TR Voltas make inverter type AC of model 185VJZJR32 complete all as specified and directed.
Supply and fix PC board of 1.5 TR capacity including taking down old unserviceable one complete all as specified and directed.
Taking down unserviceable out door unit fan/blower fan motor of 1.5 TR and fixing new blower fan motor suitable for existing 1.5 TR Voltas make inverter type AC of model 185VJZJR32 complete all as specified and directed.
Taking down unserviceable out door unit fan blade for split type AC of 1.5 TR and fixing new fan blade suitable for existing 1.5 TR Voltas make inverter type AC of model 185VJZJR32 complete all as specified and directed.
Supply only refrigerant gas R32 in manufactures sealed cylinder complete all as specified and directed, Note - (i) Payment shall be made for Net weight of gas. (ii) The contractor shall ensure no leakage of gas
M&L for taking down of unserviceable compressor for split AC 1/1.5 TR and supply & fix new compressor suitable for existing 1/1.5 TR Voltas make inverter type AC of model 185VJZJR32 complete all as specified and directed.
Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces to walls floors etc. complete all as specified and directed.
M&L for point wiring with PVC insulated unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws for One light / fan / bell point controlled by one switch complete all as specified and directed.
All as per Item No 68 here in before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches complete all as specified and directed.
All as per Item No 68 here in before but for ne 5A 2pin/3pin switch socket out let multipurpose on independent Board complete all as specified and directed.
All as per item No. 03 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board complete all as specified and directed.
Supply & fix in repair switch piano single pole flush type 5A, 240 V one way complete all as specified and directed.
Supply & fix in repair bell push flush type 5 amp, 250 Volts complete all as specified and directed.
Supply & fix in repair switch socket combination 2 in 1, 5 Amps multipurpose flush type complete all as specified and directed.
Supply & fix in repair switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed.
Supply & fix in repair Ceiling rose surface bakelite three terminal, 240 V complete all as specified and directed.
Supply & fix in repair electronic fan regulator Step type 2 module type 240V suitable for ceiling fan complete all as specified and directed.
Supply and fix in repair bell ding dong AC 230 V single pole complete all as specified and directed.
Supply and fix in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.. Make: Crompton Cat no. CCS-100-20-65-HL2-DP-NWH or equivalent in Philips/Bajaj/Havells.
Supply and fix in replacement tube light fitting 10 W, 230 volts, with slim decorative box type batten prewired, PC Batten, efficiency of 100 Lumence/Watt, including fixing mounting blocks 2 Nos, 1.5 sqmm 3 core Pvc insulated copper conductor cable complete all as specified and directed. Make: Crompton Cat no. CCS-102-10-65-SL-DP-NWH or equivalent in Philips/Bajaj/Havells.
Supply & fix in repair MCB DB Double Door SPN 12 way 240 volts all as specified and directed.
S&F in repair single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed.
Supply & fix in repair MCB SP, 240 volt, 6 to 32 Amps, 10 KA, C Curve complete all as specified and directed.
Supply & fix in repair MCB SPN, 240 volt, 40 to 63 Amps, 10 KA, C Curve, complete all as specified and directed.
Supply & fix in repair MCB TPN, 415 volt, 16 to 32 Amps, 10 KA, C Curve complete all as specified and directed.
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated FR multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly complete all as specified and directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
Taking down carefully ceiling fan, exhaust fan of any make and any sweep and dismentaling of blades canopy down rod etc & remove to store for repair and refix the same including provision of 3 core 1.5 sq mm copper flexiable cable from ceiling rose to connector complete all as specified and directed.
Overhauling of Ceiling Fan 1200 mm Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts, replacing of ball bearing, capacitor etc and testing complete all as specified and directed.
Supply and fix Capacitor up to 2.5 Mfd all as specified and directed
M&L for opening of body of exhaust fan of 250/300mm sweep removing of burnt winding cleaning, Rewinding of fan by super ennameled copper insulated wire as per existing guage, varnishing, heating assembling, replacing of bearing, capacitor and testing complete all as directed by Engineer-in-charge.
Supply and fix Capacitor up to 4 Mfd all as specified and directed.
M&L for taking down existing defective storage water heater 25 ltrs storage Capacity for carrying out repairs work such as replacing worn out parts, heating element of 2 Kw,safety valve, non return valve, indicator and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, complete all as specified and directed.
Bharat Udyog
BABBAR ENGINEERS
Allied Trading Company
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .