Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.5 L+₹2.1 L (9.32%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.6 L+₹2.3 L (10.1%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹25.3 L+₹2.9 L (12.9%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹25.8 L+₹3.4 L (15.2%)Rejected-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
29 Sept 2020, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/REPLCEMENT OF GI/CI PIPE LINES INCLUDING OF VALVES AND MAINTENANCE OF WATER TREATMENT PLANT IN DOMESTIC AND TECHNICAL AREA AT AFS YELAHANKA
2020_MES_370912_2
8818/E8
Open Tender
Civil Works - Canal
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹60,000
Yes
22 Dec 2020
15 Sept 2020
1 Oct 2020
15 Sept 2020
29 Sept 2020
16 Sept 2020
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth getting out in hard/dense soil, for removing/laying pipes complete all as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 Cms all as specified and as directed.
Removing excavated material not exceeding 50mtr and depositing where directed to a level not exceeding 1.5 metre above the starting point all as specified and as directed.
Dismantling and taking down the clogged/unserviceable GI pipe 15mm dia from trenches/floor/wall all as specified and as directed. Note: Excavation, refilling & removing surplus soil shall be measured and paid separately.
All as per Item No 04 hereinbefore but of size 20 mm dia all as specified and as directed.
All as per Item No 04 hereinbefore but of size 25mm dia all as specified and as directed.
All as per Item No 04 hereinbefore but of size 40mm dia all as specified and as directed.
All as per Item No 04 hereinbefore but of size 50mm dia all as specified and as directed.
All as per Item No 04 hereinbefore but of size 80 mm dia all as specified and as directed.
Taking up cast iron water mains including all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead of pipe of size 100 mm dia all as specified and as directed.
Taking up cast iron water mains including all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead of pipe of size 150 mm dia all as directed.
Material and Labour for GI pipe 15mm dia medium grade laid in trenches/fixed on wall/floor all as specified and as directed.
All as per Item No 12 hereinbefore, but of size 20mm dia all as specified and as directed
All as per Item No 12 hereinbefore, but of size 25mm dia all as specified and as directed
All as per Item No 12 hereinbefore, but of size 40mm dia all as specified and as directed
All as per Item No 12 hereinbefore, but of size 50mm dia all as specified and as directed
All as per Item No 12 hereinbefore, but of size 80mm dia all as specified and as directed. Note for item No 12 to 17: Excavation, refilling & removing surplus soil shall be measured and paid separately.
Supply laying jointing and testing of Ductile pipe iron class K-7 socket and spigot type of size 100 mm dia all as specified and as directed by Engr-in-charge
Supply laying jointing and testing of Ductile pipe iron class K-7 socket and spigot type of size 150 mm dia all as specified and directed by Engr-in-charge
Material and labour for DI specials for bends (any type, radius and angle) tapers any type,(straight ,bend, increasing, decreasing, or double socket etc) Tee pieces single branch."Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs up to 150mm bore Di pipes all as specified and as directed.
Material and labour for jointing of DI pipes with rubber tyton joints of size 100 mm dia all as specified and as directed.
Material and labour for jointing of DI pipes with rubber tyton joints of size 150 mm dia all as specified and as directed.
Dismantling and taking down unserviceable sluice valve 150mm dia from valve chamber/pipe line all as specified and as directed by Engr-in-Charge
All as per item no.23 hereinbefore but of size 100 mm dia all as specified and as directed
All as per item no.23 hereinbefore but of size 80 mm dia all as specified and as directed
Dismantling and taking down unserviceable gun metal gate valve/globe valve 20mm dia from valve chamber/pipe line all as specified and as directed by Engr-in-Charge
All as per Item No-26, hereinbefore but of size 25mm dia all as specified and as directed
All as per Item No -26, hereinbefore but of size 50mm dia all as specified and as directed
Material and labour for sluice valve 150mm dia both end flanged PN 1.0 with fixing arrangements such as bolt / nuts, rubber packing’s etc all as specified and as directed.
All as per item No.29 hereinbefore but of size 100 mm dia all as specified and as directed
All as per item No.29 hereinbefore but of size 80 mm dia all as specified and as directed
Material and labour for gun metal gate valve both end screwed of size 20 mm dia all as directed by Engr-in-charge
All as per Item No-32 here in before, but of size 25 mm dia all as specified and as directed
All as per Item No-32 hereinbefore ,but of size 50 mm dia all as specified and as directed
Dismantling and taking out the Unserviceable 50 mm dia column pipe from the bore wells.
Supply and Fixing of GI column pipe heavy grade 50mm dia with ISI mark with GI heavy socket at one end all as specified and as directed
Material and labour for removing unserviceable lead joints from CI pipe line and making proper run lead joints of size150mm dia complete including necessary excavation, refilling and removing the surplus soil all as specified and as directed.
All as per Item No-37, hereinbefore but for size of 100mm dia pipe line all as specified and as directed.
All as per Item No-37, hereinbefore but for size of 80 mm dia pipe line all as specified and as directed.
Dismantling and unscrewing the bolt/nuts, taking out the suction pipe along with unserviceable foot valve of 150mm dia all as specified and as directed.
All as per Item No-40, hereinbefore but of size 100 mm dia all as specified and as directed.
All as per Item No-40, hereinbefore but of size 80 mm dia all as specified and as directed.
Material and labour for CI foot valve flanged type of size 150mm dia complete with bolts/nuts, washers, rubber packing etc all as specified and as directed.
All as per Item No-43, here in before but of size 100 mm dia all as specified and as directed.
All as per Item No-43, here in before but of size 80 mm dia all as specified and as directed.
Dismantling and taking down unserviceable Non return valve 100 mm dia from pipe line all as directed by Engr-in-Charge
All as per Item No-46, hereinbefore but of size 80 mm dia all as specified and as directed
Material and labour for Non return valve 100mm dia both end flanged with fixing arrangements such as bolt / nuts, rubber packing’s etc all as directed.
All as per Item No-48 but of size 80 mm dia all as specified and as directed.
Chemical and Bacteriogical analysis of water as per IS-10500, sample collected from bore wells/shallow wells/BWSSB water /user point all as directed by Engr-in-Charge. Note- water to be tested once in every 6 month and approved at NABL LAB.
Construction of valve chamber of size 900 mm x 900 mm x 900 mm internal size suitable for sluice valve, with PCC (1:4:8) type (D2) for foundation one brick wall in cement mortar (1:4) PCC (1:2:4) type B1 for coping rendering in CM (1: 4) 15 mm thick including provision of mild steel sheet cover 3.15 mm thick on 40 x 40 x 6 mm angle iron frame work with two coat of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation, earth work and demolishing the damaged valve chamber and removing debris as directed, all as specified and as shown on drawing.
SRINIVASA ENTERPRISES
yashaswini buliders
Mahant Construction Co.
ANAND REFRIGERATION
Thirumala Construction
B5BUILDING SOLUTIONS
RAMESH BABU CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .