Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | ₹35.5 L Quoted ₹35.6 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹38.7 L+₹3.1 L (8.82%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹38.7 L+₹3.1 L (8.82%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹38.8 L+₹3.1 L (8.85%)Rejected-Finance | ₹38.8 L+₹3.1 L (8.85%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹39.0 L+₹3.4 L (9.55%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹39.0 L+₹3.4 L (9.55%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹39.4 L+₹3.8 L (10.6%)Rejected-Finance 20 23 MANASKAMANA ROAD BANSBARI MORE PS ENGLISHBAZAR DT MALDA | ENGLISHBAZAR | MALDA | WEST BENGAL | 732101 | ₹39.4 L+₹3.8 L (10.6%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹69,400
Closing Date
28 Jun 2021, 6:00 pmClosed
GE DIPATOLI
GARRISON ENGINEER MES DIPATOLI MIL STN P.O. - HOTWAR RANCHI (JHARKHAND) 834 012
REPAIR MAINT TO UNSERVICEABLE INTERNAL WIRING, LIGHT FITTINGS IN MD OTM BLDGS OF ENGR REGT, ASC BN EME BN AREA UNDER GE
2021_MES_446383_1
8000/1681/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
DIPATOLI
CLASS D CATEGORY a(i)
8 documents required · 8 mandatory
₹500
Yes
GE DIPATOLI
₹69,400
Yes
10 Jul 2021
2 Jun 2021
30 Jun 2021
2 Jun 2021
28 Jun 2021
16 Jun 2021
Amount
PHASE - I : REWIRING Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) complete, including fixture and fittings such as swithes, ceiling roses, pendants, regulators, Sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit at site and making good disturbed surfaces of walls, floors, roofs etc complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls, floors, roofs etc complete all as specified and as directed.
Taking down old/unserviceable MCB DB SPN any capacity by disconnection of electric connection including MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed.
Taking down Old/ Unserviceabl MCB DBs TPN / Main Switches by disconnection of electric connection including old unserviceable MCCBs, MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm, single core, multi stranded copper conductor PVC insulated and unsheathed FR cable 1100 Volts grade, drawn through PVC concealed conduit pipe med grdae 20/25 mm on wall/ceiling, including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes 1.6 mm thick, chromium plated screw /Modular plate with frame and modular concealed GI sheet metal boxes ( 16 Gauge) as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and concealed GI sheet metal boxes, modular plate with frame, cutting of hylem sheet for fixing of switch and scoket including cutting chases etc in wall and making good to disturbed surface and matching with existing wall, ceiling surfaces.
All as per Ser item No 5 here-in-before but one 3 Pin Socket out let 5 Amps on the same board complete all as specified and directed.
All as per Ser item No 5 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board complete all as specified and directed.
All as per Ser item No 5 here-in-before but one bell/buzzer point controlled by one push button on the independent board complete all as specified and directed.
All as per Ser item No. 5 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size complete all as specified and directed.
All as per Ser item No 5 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm, single core, multi stranded copper conductor PVC insulated and unsheathed FR cable 1100 Volts grade, drawn through PVC casing / caping 20/25 mm on wall/ceiling, including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes 1.6 mm thick, chromium plated screw /Modular plate with frame and modular concealed GI sheet metal boxes ( 16 Gauge) as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and concealed GI sheet metal boxes, modular plate with frame, cutting of hylem sheet for fixing of switch and scoket including cutting chases etc in wall and making good to disturbed surface and matching with existing wall, ceiling surfaces.
All as per Ser item No 11 here-in-before but one 3 Pin Socket out let 5 Amps on the same board complete all as specified and directed.
All as per Ser item No 11 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board complete all as specified and directed.
All as per Ser item No 11 here-in-before but one bell/buzzer point controlled by one push button on the independent board complete all as specified and directed.
All as per Ser item No.11 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size complete all as specified and directed.
All as per Ser item No 11 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly complete all as specified and directed.
S&F Switch Piano type 2 way switch 5 amp 230 v complete all as specified and as directed.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed.
S&F Socket outlet 2-in-1, 3 pin, 5 and 15 amps, flush type complete all as specified & directed.
S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified and as directed.
S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified and as directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F 120 w, electronic fan regulator Rotary step type 240 Volts single phase, 50 Hz complete all as specified and as directed.
M&L for Angle lamp holder (metal ring), PVC /Polycarbonate type with back plate complete all as specified and directed at site.
S&F 10 Amp 1 Way modular switch, 240 volts one module complete all as specified and directed. Make : Anchor Roma cat part No 21011 or equivalent as per list of makes.
S&F 10 Amp 2 Way modular switch, 240 volts one module complete all as specified and directed at site. Make : Anchor Roma cat part No.21022 or equivalent as per list of makes.
S&F 10 Amp modular bell push switch, 240 volts one module complete all as specified and as directed. Make : Anchor Roma Cat part No.21044 or equivalent as per list makes.
S&F modular switch 20 Amp 1 way switch one module, 240 volts complete all as specified and directed at site. Make : Anchor Roma cat part No.21066 or equivalent as per list of makes.
S&F modular socket 10 Amp multi socket for Cell phone pin or 2 pin & 3 Pin, 240 volts, two module complete all as specified and as directed. Make : Anchor Roma cat part No.30373 or equivalent as per list of makes.
S&F modular socket one way 20 Amp & 10 Amp Twin Socket (heavy duty), 240 volts two module complete all as specified and as directed. Make : Anchor Roma Cat part No.30828 or equivalent as per list of makes.
S&F regulator modular step type one way 220 volt two module complete all as specified and as directed. Make : Anchor Roma Cat part No.30828 or equivalent as per list of makes.
S&F TV socket modular one module complete all as specified and as directed. Make : Anchor Roma Cat part No.21157 or equivalent as per list of makes.
S&F telephone socket modular one module complete all as specified and as directed. Make : Anchor Roma Cat part No.20857 or equivalent as per list of makes.
S&F in replacement of modular USB Charger complete all as specified and as directed. Make : Anchor Roma Cat part No.20460 or equivalent as per list makes.
S&F in replacement blanking plates for covering of MCCB DB open space complete all as specified and directed at site. Make : Anchor Roma cat part No.21598 or equivalent as per list of makes.
S&F in repacement switch socket combination 2 in 1, 3 pin 5 and 15 amp flush type as per existing model and size complete all as specified and directed at site.
S&F in repacement switch socket combination 2 in 1, 5 pin 5 amp flush type as per existing model and size complete all as specified and directed at site.
S&F in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps complete all as specified and directed at site. Make-Havells Cat part No. DHDPUSN020/DHDPUDP020 or equivalent as per list of makes.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
Description all as per ser item No. 41 here-in-before but 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 41 here-in-before but 2 x 4 sqmm and 1 x 4 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 41 here-in-before but 2 x 6 sqmm and 1 x 6 sqmm for earth wire complete all as specified and as directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade, drawn in with and including PVC casing / caping 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
Description all as per ser item No. 45 here-in-before but 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 45 here-in-before but 2 x 4 sqmm and 1 x 4 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 45 here-in-before but 2 x 6 sqmm and 1 x 6 sqmm for earth wire complete all as specified and as directed.
M&L fot fixing PVC Casing/ caping 20/25 mm on wall/ceiling, including replacement of old unserviceable PVC casing /caping, for existing old serviceable point wiring for existing old serviceable point wiring of 1.5mm,/2.5mm,/4mm /6 sqmm, existing wiring/Submain wiring drawn through new PVC Casing caping/conduit on wall/ceiling, including replacement complete all as specified and as directed. (Note:- The rate quoted is deemed to be included for taking down of unserviceable PVC Casing caping/ conduit including cutting & fixing charges & making good to disturbed surface matching with existing surfaces.)
Supply and fix MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. Make -Havells Cat part No.DHDPSHODRW04 or equivalent as per list of makes.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. Make -Havells Cat part No.DHDPSHODRW08 or equivalent as per list of makes.
Supply and fix MCB DB SPN 12 way double door with metal door suitabl for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directedcomplete all as specified and directed at site. Make -Havells cat part No.DHDPSHODRW12 or equivalent as per list of makes.
Supply and fix MCB DB TPN 4 way double door with metal door suitable for Provision of incommer MCCB and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. Make -Havells Havells cat part No.DHDLVDRWGOFO04 or equivalent as per list of makes.
S&F in replacement of MCCB 3 Pole 415 volt 100 amp 50 Hz adjustable type with breaking capacity 10 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCCB 3 Pole 415 volt 63 amp 50 Hz adjustable type with breaking capacity 10 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 volt 100 amp 50 Hz adjustable type with breaking capacity 25 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 volt 63 amp 50 Hz adjustable type with breaking capacity 25 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make Havells cat part No. DHMGCSPF006-32 or equivalent as per list of makes.
S&F in replacement of MCB SP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles. Make -Havells cat part No.DHMGCSPF063 or equivalent as per list of makes.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles. Make -Havells cat part No.DHMGCDPF040 or equivalent as per list of makes.
S&F in replacement of MCB DP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make -Havells cat part No.DHMGCDPF063 or equivalent as per list of makes.
S&F in replacement of isolator DP 40 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator TPN 40 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator TPN 80 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator TPN 100 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of LED tube light fitting 1x18/20 watt 230 Volt decorative ultra slim linear LED Lighting with extruded polycarbonate, including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Cat/part No. LUMILINEPLUSBS18WLED865SPCSS of Havells or equivalent in philips/Wipro/Jaguar.
S&F in replacement of Lienear and compact 9 watt LED mirror light with decorative end caps plocarbonate body and ribbed opal diffuser including 2/3 core flexible copper wire with flexible pipe ceiling rose to light fittings complete all as specified and as directed. Make : Cat/part No. LUMILINEBS9WLED865SPCWH of Havells or equivalent in philips/Wipro/Jaguar.
S&F in replacement of environmental friendly ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity comprising of high brightness LEDs IP 54 protection with all accessories including connecting up with 2/3 core twisted flexible copper conductor cable complete all as specified and as directed. Make : Philips cat part No. CWLL01V109XX or equivalent in Havells / HPL.
S&F in replacement of LED batten tube light fitting 20/22 watt 230 Volt decorative Endura Linear Neo LED Light fitting with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.Including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : - Cat/part No:-ENDURALINEARENEOBS22WLED830SPCWH of Havells or equivalent in Philips/HPL/C&S
S&F in replacement Decorative wall light fitting CT2 10 W made up of polycarbonate,complete all as specified and directed at site. Make : Havells Cat Part No.LHDL03160099 or equivalent in philips /Wipro
Supply and fix in replacement 'JUNO' integral post top lantern copper dust painted cast aluminium spigot,spun aluminium canopy with clear acrylic cover with 20 Watt LED lamp including all accessories such as Bracket, GI Pipe and prewired complete all as specified and directed at site. Make : Jaguar cat part No. 340.33.NGG or equivalent in Havells/ HPL
Supply and fix in replacement 'JUNO' integral post top lantern copper dust painted cast aluminium spigot,spun aluminium canopy with clear acrylic cover with LED lights including all accessories such as Bracket,GI Pipe and prewired complete all as specified and directed at site. Make : Havells cat part no. CORALMINIPT1 WLED757PSYMTOPC or equivalent in C&S/ PHILIPS/L&T
S&F in replacement of building LED security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site.Make : Havells Cat No:-ENDURACITYLITEPLATPLUSSL35WLED 757SASYBOPC or equivalent in Philips/C&S
S&F in replacement of Ultra slim LED celing light fitting 20 watt, warm white type 230 Volt made from extruded aluminium housing frame (recesss/pendant) complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : C&S/Havells/ HPL
S&F in replacement of Ultra slim LED panel tube light fitting 36 watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) 2' x2' Complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : Cat/part No LSVR01S036XN of Jaguar/ /Havells cat part No.LHEWBPP7PL1w036/ Indus plus of HPL
M&L for repair/greasing of ceiling fan of any size sweep single phase celing fan of any size opening from any height or any locations, fan opening from hook, clamp & refixing the same after cleaning and greasing with requird necessary cutting/ welding/ grinding job or required store such as nuts, bolts, washer and suitable length mild steel/ down rod duly making holes etc complete all as specified and as directed.
S&F in replacement PVC ventilating air fan single phase 250 mm sweep complete with louver shutter and including making hole of suitable size, fan base after cutting of brick/stone wall of suitable size of water proof ply wood complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
S&F in replacement PVC ventilating air fan single phase 300 mm sweep complete with louver shutter and including making hole of suitable size, fan base after cutting of brick/stone wall of suitable size of water proof ply wood complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
Supply, Laying on replacement, connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with aluminium conductor cable complete all as specified and as directed. Note:- Excavation, earthwork and protection of cable shall be measured and paid seperately.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified and as directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed.
Supplying and spreading dry river sand for cable cushioning in trenches complete all as specified and as directed. Note:- Punned down thickness shall be considered for measurement. .
Supply and lay kiln burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection complete all as specified and as directed.
M &L for GI Earthing complete with GI earth plate electrode (60cm x 60cm) x6 mm thick buried directly in ground vertically to size of depth not less than (0.90x 0.90)m x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth wire of size 8.00 mm dia 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers, testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 5 of SSR Part - I connected to earthing lead with Main switch/main control board, filling with charcoal dust 200 Kg, and common salt 100 KG, including necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade, PCC chamber (1:3:6) type C1 (for even finish on both the faces) and RCC cover (1:2:4) Type B1, (450 x450)mm x 50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod complete all as specified and as directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC. Note : i) Earthing test must be carried out in presence of Engr-in-Charge/JE E&M. ii) The earthing result not more than 2 Ohms or desired earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of RAR.
PHASE-II : OUTSOURCING OF METER READER Outsourcing of services for Noting and recording the readings of electric consumptions of electronic energy meters of any type and any capacity located at different consumers premises (commence w.e.f 1st of each month for 26 days) for Married officers accommodations, Single officers accommodations, PBORs Md accommodations,Private parties including bulk consumers i.e Offrs MESS, Schools, CSD, URC etc), staff of KV School, MES/Defence Civilian accommodation etc. situated in Dipatoli Mil Station under GE Dipatoli on monthly basis by deploying adequate menpower / meter reader (Minimum 02 Nos) on all working days except sunday and holidays for approximate 2200 electric meters for 11 months. ie-2200x11=24200 Meters (approx) including followings :- (a) Entering the readings in user's Meter Reading Cards and also entering in a seperate register held with meter reader duly signed by users of respective premises including entry in auditable Meter Reader Book and submitting the data upto 10th of each month to BSO or as directed by Engineer-in-Charge. (b) Entering and updating the rentable register as per occupation/vacation reports of all officers accommodation as per allotment and PBORs Md accommodation as per reports recd from respective on monthly basis. (c) Entering the vacant accn in the register of vacant qtrs on monthly basis and Submitting the report/register to BSO ,GE Dipatoli every Month before 10th day. (d) Preparing following documents of all residential/domestic Govt" accommodations / Private and commercial consumers defence civilians/MES key personnels residing in Govt' accns:- (i) Feeding the recorded reading data to central computer in BSO office every month for each consumer. (ii) Preparing the Return of recoveries for electric consumption as per required format quarterly for all service officers and PBORs only. (iii) Submitting the RR to BSO GE Dipatoli. every quarter before 10th day of residential / domestic govt accn and each month before 10 th day of all private and commercial consumers. (e) The contractor shall arrange to provide 1 x Computer (desk top) with printer & power back up and CD driver facility required for prepartion/uploading of bills for data entry operators during entire contract period and may take back after completion of contract after deleting / formating of entire datas. The computer and other connected periperhals are under custodian of Engineer-in-Charge for contract period. The cost of this shall deemed to be included in the quoted rates.
M/s Ray construction
M/s R R MUKHERJEE & CO
M/S KAMLESHWAR SINGH
M/s Mukesh and company
M/S Akash Enterprises
M/S.R.S.Chauhan and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .