Executive Engineer Div-XVI Margao.
Vidhyut Bhavan, Annex Building Aquem Margao Goa
Work of S.E.T.C of new 100KVA Distribution Transformer Centre at Talem, Gaondongrim to solve low voltage problem faced by the residents of Talem under Sub DivisionIII, Canacona, Division-XVI, Margao
2025_ED_26168_1
Tender No 22(2025-26)
Open Tender
Electrical Works
Percentage
365 days
Sub Division III Canacona
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹37,740
21 Aug 2026
12 Nov 2025
9 Dec 2025
12 Nov 2025
8 Dec 2025
12 Nov 2025
COST OF MATERIAL
Supply of 9.0 meters long R.C.C. Pole.
Supply of 7.5 meters long R.C.C. Pole.
Supply of stay set for 7.5 Mtrs long RCC Pole as per technical specification
Supply of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification
Supply of Enamelled danger board as per DRG No. CEE/490
Supply of Hot dip galvanised structure material for mounting Distribution box
Supply of HDGI L.A./S.A. cross arm clamps suitable for 9mts RCC pole as per Drg No. CEE/E-524.
Supply of HDGI L.A./S.A. cross arm clamps suitable for 7.5 RCC pole as per Drg No. CEE/E-524.
Supply of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching.
Supply of Loss Level-II 100KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification.
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.
Supply of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification.
Supply of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification.
Supply of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705.
Supply of HDGI 2 pin LT cross arm channel type as per Drg. No. CEE/E/704.
Supply of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The LT Pin Insulator shall be as per technical specification.
Supply of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. The LT shackel insulator shall be as per Technical specification.
Supply HDGI G.I. Hexagonal head bolts and hexagonal nuts conforming to IS 1363 part I to III 1992 as amended upto date of the size 3 ½" x 5/8" or 4" x 5/8",6"x5/8", 8"x5/8" or as per the requirement.
Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials: 1) Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date 2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category "A" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest. 3) 1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4) Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV) 5 Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug
Supply and Fixing of CAMR Modem as per technical specification.
Supply of XLPE cable armoured 3 ½ core 185 sqmm 1.1kv grade.
Supply of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade.
Supply of XLPE cable 11KV 3C X 300 sq.mm armoured
Supply of XLPE cable 11KV 3C X 95 sq.mm armoured
Supply of H.S 11K V Straight through joint 3 core, 300 SQMM
Supply of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core
Supply of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core
Supply of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
Supply and filling of sand in plinth uner floors , trenches including waterin, ramming consolidating, dressing complete.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size)excluding cos t of centering and shuttering and finishing for foundations.ALL WORKS UPTO PLINTH LEVEL
Providing Centering and shuttering including struttings, propping etc and removal of formwork
Supply and Providing of 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations.
Brick work using common burnt building bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 75 kgs/ cm2 (wire cut bricks)
Supply and laying of burnt clay wire cut bricks of 75 Kgs/cm2 class.Wire cut bricks.
Supply of GI Tubular Fencing complete with gate and side dismantling syatem as per the specification for distribution transformers and feeder Pillars (size 4M X 3M X 2M) with concreting for GI fencing supports with plinth(0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1:3:6 and brick masonary [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT, suitable for high salinity coastal areas].
Supply and Laying of Cuddappa of size 600mm length x 250mm width and 1 inch thick and covered with earth/ sand upto depth of 0.15mts. Confirming to IS 1255-1967 at non-road crossing.
Supply of Class B HDGI pipe of diameter 150 mm dia.
Supply of Class B HDGI pipe of diameter 100 mm dia for cable rising.
Supply of GI Flat 25 x 5 mm.
Supply of RCC Cable route Marker
COST OF ERECTION
Erection of 9.0 meters long R.C.C. Pole.
Erection of 7.5 meters long R.C.C. Pole.
Erection of stay set for 7.5 Mtrs long RCC Pole as per technical specification
Erection of HDGI stay rod with plate complete for 9 mts. Long RCC pole as per technical specification
Erection and commissioning of MS Distribution Box alongwith 12nos. 200A Kit Kat fuse and MCCB of 400Amps, 415 Volts. The box shall be fabricated with MS sheet 12 gauge with overlapping rain proof slit ventilators on both sides of the distribution box with wire mesh to prevent entry of insects with pin head door hinges locking arrangement and shall have required number of bus bars made out of Aluminium strips of size 40 x 10mm for connecting MCCB, fuses and cables (for 4 feeder arrangement) & other accessories. The box shall also have 'magnetic hold' arrangement to ensure that the box doors always remains in 'closed' positiion when shut even without latching.
Erection, testing and commissioning of Loss Level-II 100KVA, 11/0.433KV 3 PH. Aluminium Wound Distribution Transformer as per technical specification.
Earthing complete with 40mm GI Pipe, 2.5 mts long alongwith 20 kgs each salt, charcoal complete with brick masonary.
Stringing of AAC ' ANT ' conductor of size 7/3.14mm. The stringing rate includes transportation, jointing, etc. 7.44 Kms of conductor shall be strung as phases for LT line. The conductor shall be comply to the technical specification.
Supply and Stringing of AAC ' GNAT ' size 7/2.21mm conductor for neutral, streetlight and jumpering as well as guarding. The conductor shall be comply to technical specification.
Fixing of HDGI 4 pin LT cross arm channel type as per Drg. No. CEE/E/705.
Fixing of HDGI 2 pin LT cross arm channel type as per Drg. No. CEE/E/704.
Fixing of a) L.T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN & b) Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The LT Pin Insulator shall be as per technical specification.
Fixing of a) L.T. brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN & b) G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. The LT shackel insulator shall be as per Technical specification.
Providing of Low Tension metering to the DTC by Suplying, Installing and commissioning of following Materials: 1) Epoxy resin Cast L.T. CT coil of 300/5A, Class-0.5s, 50Hz,660V, Burden 15VA conforming to IS-2705 / 1992 as amended upto date 2) Electronic 3Phase,4wire ,Trivector Meter ,LT CT operated 3x240V,-/5A,50Hz, class 0.5s, Category "A" (DLMS COSEM Protocol) for DTC with RS 232 Optical port and complience to BIS ICS Doc: ETD 13(6211) and latest. 3) 1.1KV multistand copper conductor 2.5sq.mm, XLPE insulated, armoured control cable conforming to relevant IS amended upto date.4) Pole mounted M.S Box ( outdoor type) for Electronic Meter as Drawing No.EE/VIII/64(REV) 5 Al. L shape flat 40mm suitable for mounting on bushing rod and brass lug
Erection of XLPE cable armoured 3 ½ core 185 sqmm 1.1kv grade.
Erection of XLPE cable armoured 3 ½ core 120sqmm 1.1kv grade.
Erection of XLPE cable 11KV 3C X 300 sq.mm armoured
Erection of XLPE cable 11KV 3C X 95 sq.mm armoured
Erection of H.S 11K V Straight through joint 3 core, 300 SQMM
Erection of H.S.11 KV Termination kit indoor 300 sqmm. XLPE 3 core
Erection of H.S.11 KV Termination kit indoor 95 sqmm. XLPE 3 core
Erection of H.S.11 KV Termination kit outdoor 95 sqmm. XLPE 3 core
3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU.
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Disposal of exavated soil
Erection of GI Tubular Fencing complete with gate and side dismantling syatem as per the specification for distribution transformers and feeder Pillars (size 4M X 3M X 2M) with concreting for GI fencing supports with plinth(0.3x0.3x0.5) Cu.mx12 nos. Each ratio 1:3:6 and brick masonary [Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT, suitable for high salinity coastal areas].
Laying of Class B HDGI pipe of diameter 150 mm dia.
Erection of RCC Cable route Marker
Erection of LED Street Light 30Watts
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 22.06 MB
BOQ_26603.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .