AGE I RD AVADI CHENNAI 600054
REPAIRS AND MAINTENANCE OF WATER SUPPLY PLUMBING MACHINERY AND OTHER CONNECTED WORKS AT CVRDE AVADI
2020_MES_331762_2
8229/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Avadi
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,800
Yes
3 Jul 2020
14 May 2020
13 Jun 2020
14 May 2020
9 Jun 2020
26 May 2020
14 May 2020 - 26 May 2020
Amount
Disconnecting electrical connections of centrifugal pump set and decoupling the pump and motor, removing from the installed position by putting dummy plate to suction and delivery pipe, transporting to work shop. Disassemble the motor, removing the burnt out windings and cleaning the slot with CTC, rewinding the same with suitable super enameled copper conductor, insulating varnishing, removing, replacing the worn out bushes/ bearing and re-assembling motor and pump shaft repair by lathe work for proper alignment, replace gland rope, rubber coupling, washers, nuts and bolts or smooth function with one coat of primer & two coat of synthetic enamel paint after scraping the body surface of pump & motor with emery paper, writing letters, assemble the motor & pump set Transporting to site coupling, connecting electrical & pipe connections testing complete for following capacity all as specified and directed. (a) 30HP Pump set at pump house residential area.
M&L for Disconnecting and removing the existing monoblock pump set from the installed position by putting dummy plate to suction and delivery pipe line, transporting to workshop. Disassemble the motor removing the burnt out windings, cleaning slots with CTC, and rewinding the same with suitable super enameled copper conductor, insulating varnishing, removing, replacing the worn out bushes/ bearing and pump shaft repair by lathe work for proper alignment, replace gland rope, rubber coupling, washers, nuts and bolts for smooth function with one coat of primer & two coat of synthetic enamel paint after scraping the body surface of pump & motor with emery paper, writing letters ,assemble the motor & pump set Transporting to site coupling, connecting electrical & pipe connections testing complete for 20HP cap at Residential area pump house complete all as specified and directed by Engineer-in-charge.
All as per above item No 2 but capacity 15 HP at Technical area pump house
All as per above item No 2 but capacity 15 HP at Residential area pump house
All as per above item No 2 but capacity 7.5 HP at Residential area pump house
All as per above item No 2 but capacity 7.5 HP at Technical area pump house
All as per above item No 2 but capacity 5 HP at Technical area pump house
All as per above item No 2 but capacity 5 HP at Residential area pump house
All as per above item No 2 but capacity 3HP at Residential area pump house
M&L for painting one coat of primer & two coat of synthetic enamel paint over pump set, foundation channel complete after scraping existing paint from surface with emery paper, writing letters of pump set capacity 30HP Centrifugal pump set at Residential area complete all as specified and directed by Engineer-in-Charge.
All as per above item No 10 but capacity 20HP monobloc pump set Residential area
All as per above item No 10 but capacity 15HP monobloc pump set at Residential area
All as per above item No 10 but capacity 7.5 HP pump set Residential area
All as per above item No 10 but capacity 3 HP pump set Residential area
All as per above item No 10 but capacity 15 HP monobloc pump set at Technical area
All as per above item No 10 but capacity 7.5 HP monobloc pump set at Technical area
All as per above item No 10 but capacity 5 HP monobloc pump set at Technical area
All as per above item No 10 but capacity 5HP monobloc pump set Residential area
S&F in replacement of Direct-On-Line starter in sheet metal enclosure Type MK suitable for motor rating upto 7.5HP, 415V, 50Hz relay range 13-22A complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of fully automatic star delta starter in sheet metal enclosure Type MK 1F suitable for motor rating upto 15HP, 415V, 50Hz relay range 14-23A complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of dry run protection relay with single phase protection unit microcontroller current based type with digital meter suitable for starter rating upto 40A, 415V in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnecting pipeline and servicing water filtration unit tank by dismantle the filtration unit remove the unserviceable filter components complete and fill with following (a) multigrade filter complete and fill fine sand & coarse sand 10/5mm sylex suitable for removing 20micron sediment.(b) activated carbon filter for suitable to remove 900mg and suitable qty of pebbles with including repair/alternation work in tank. removing existing paint from outer surface of filtration cylinder tank and apply one coat primer and two coat of synthetic enamel paint and servicing control valve, checking the back washing valves and testing & commissioning the entire unit complete etc all as specified and as directed by Engineer-in-Charge.
M&L for medium grade GI tubing 80mm dia with all fitting and fixed at suction & delivery line of pump set complete including taking down unserviceable GI 80mm all as specified and as directed by Engineer-in-Charge.
M&L for medium grade GI tubing 50mm dia with all fitting and fixed at sunction & delivery line of pump set complete including taking down unserviceable GI 50mm all as specified and as directed by Engineer-in-Charge.
M&L for medium grade GI tubing 40mm dia with all fitting and fixed at sunction & delivery line of pump set complete including taking down unserviceable GI 40mm all as specified and as directed by Engineer-in-Charge.
M&L for GI tubing 20mm dia medium grade pipe after disconnecting between pump house service tank& pump set (priming pipe) including taking down unserviceable tubes 20mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L for sluice valve flanged & drilled holes type of size 150mm bore with high tensile S/S spindle duly ISI marked class PN 1.6 with jointing material and nut, bolt, washer complete including taking down of unserviceable sluice valve all as directed by Engineer-in-Charge.
All as per item No 28 here in before but sluice valve size 100mm dia
All as per item No 28 here in before but sluice valve size 80mm dia
M&L for replacement of gunmetal globe/gate valve with iron wheel head, screwed both ends of 80 mm sizes ISI marked complete all as specified and as directed by Engineer-in-Charge.
All as per item no 31 here in before but 50 mm size
All as per item no 31 here in before but 40 mm size
All as per item no 31 here in before but 25 mm size
M&L for removing old paint and apply one coat of primer & two coat of synthetic enamel paint over suction and discharge GI pipe line 40, 50 to 80mm dia including writing letters/marking arrow at water supply installation as specified supply Installation as specified and as directed by Engineer-in-Charge. Note : Tint of paint shall be as direction of AGE(I).
S&F chloroscope test kit with sheet metal enclosure box suitable for testing residual chlorine range ppm 0.1PPM to 2PPM at water supply installation including taking down unserviceable chloroscope complete all as specified and as directed by Engineer-in-Charge.
S&F fix valve chamber ms cover 6mm thick size 1200x900mm size including angle iron 40x40m size writing identification distribution area/ number by paint including unserviceable MS angle and sheet etc all as specified and as directed by Engineer-in-Charge.
M&L for replacement of fabricated MS angle iron/channel of any section and foundation bolts, nuts and washer made of of MS of suitable sizes including painting for motor/pump bed foundation including cement work with PCC in grouting etc complete all as specified and directed by Engr-in-charge.
M&L for Aluminium strip 25 X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including taking down un/s aluminium conductor complete all as specified and directed. Note :- rate including for scuffolding, safet belt and safety accessories for working 20Mtrs height of OHT.
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete including taking down unserviceable test point terminal complete
M&L Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6mm thick, buried directly in ground (earth bit not less than 2.25 metrs deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32 x 6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel shall be protected by 40mm dia GI light grade protection pipe, watering pipe 20mm dia GI pipe medium grade Connected to GI meshed funnel, alternative layers of charcoal and salt on all side of carth plate including necessary earth work excavation, PCC 1:3:6 earth chamber with RCC 1:2:4 cover complete all as shown in Electrical plate No, 3 including testing and taking down old earthing complete all as specified and directed by Engineer-in-Charge. Note: Quoted rate includes GI earth strip upto 7.5m and GI 40mm dia light grade protection pipe upt 7.5m. Earth strip and Protectio pipe beyond 7.5 metre shall be measured and paid separately.
Supply and fix water level indicatior mechanical type including suitable pully, stainless steel roap, float and MS level indicator scale with marking in 10cm scale for indicating 18m hight OHT water level at ground level complete including taking down unserviceable water level indicatior with accossories complete all as specified and as directed by Engineer-in-Charge.
Supply and fix water level indicatior mechanical type including suitable pully, stainless steel roap, float and MS level indicator scale, marking 10cm scale with suitable angle iron support ,painting for indicating UG sump water level at ground level complete including taking down unserviceable water level indicatior with accossories complete all as specified and as directed by Engineer-in-Charge.
S&F LED type Aviation Obstruction light Aluminium body ,Red colour with Flashing operation controller fixed from top of the 20 mtrs stage OHT with suitable fixiing materials including taking down old fittings complete all as specified and directed by Engineer-in-Charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 2core 4 sq.mm with suitable FRP support clamps for fixing upto OHT avaition light including taking down unserviceable cable cable complete all as specified and directed by Engineer-in-Charge.
Supply only O-tolidine regent solution in 500 ml bottle.
Supply and fix in replacement of dial pressure gauge 0-100 PSI all as specified and directed by Engineer-in-Charge.
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long complete including taking down unserviceable terminal rode complete all as specified and directed by Engineer-in-Charge.
SAMYDOSS CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .