Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹44.0 L+₹1.5 L (3.57%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹44.7 L+₹2.2 L (5.15%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | L4₹45.1 L+₹2.6 L (6.22%)Rejected-Finance | L4 | Rejected-Finance 4TH LOWEST | |
| 5 | L5₹45.7 L+₹3.2 L (7.49%)Rejected-Finance | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
18 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT TO PLUMBING SANITARY FITTINGS ROOF TREATMENT FLOOR WALL TILES INCLUDING CERTAIN EM WORKS OF CERTAIN BLDG OF 28 AD REGT 707 TSU 955 AD REGT WKSP LT AD BTY AND DEPOT BTY AT ZONE B AREA AT GMS UNDER GE I GOS
2021_MES_445547_1
8000/24/21-22/0923/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹86,000
Yes
7 Aug 2021
25 May 2021
21 Jun 2021
25 May 2021
18 Jun 2021
11 Jun 2021
Amount
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 75 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 20-25 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 15 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and smooth without using extra cement to receive the topping layer complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) light colour shade polished,area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per Item No. 07 above but on vertical surface of wall of size not exceeding 0.36 sqm,as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 300 x 200 mm x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles including 10mm thick rendering in CM 1 :4 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick screed bed in CM 1 :6 complete all as specified and directed.
All as per Item No. 10 above but on vertical surfaces area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as skirting including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 20mm thick screed bed in CM 1 :6 complete all as specified and directed.
All as per Item No. 12 above but on vertical surfaces area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as skirting ncluding 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like 15mm thick in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
M&L for vitreous china wash basin, white,flat back, size 550 x 400 mm with brackets, including supply & fixing pillar cock 15 mm bore CP fancy type, PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc complete all as sapecified and directed.
S&F in repair viterious china squatting pan orissa pattern size 580x440mm white integal foot rest & including 10 lit cap flushing cistern PVC low level & flush pipe including concrete bedding & including P trap 100mm complete all as specified and directed.
M&L for Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed.
S & F in repair vitreous china wash down water closet pan (pedestal pattern), white, 'P' or 'S' type, inc. 10 litres, PVC flushing cistern, L L, white, with inlet,ball valve, float & brackets, inc. flush pipe, PVC tube 32mm dia. & inc. plastic water closet seat, black, closed pattern with flat bottem, & cover & M S CP or aluminium hinging device, complete all as specified and directed.
S&F PVC 10 litres capacity valveless ,syphonic action type low level flushing cistern ,white including flush pipe, cantilever brackets ,inlet, ball valve, float and handle, PVC connection 15mm dia etc complete all as specified and directed.
S&F health faucet with fluxi pipe and hand shower ,the length of hose 1.50 mt fitted to the tap complete all as specified and directed.
S&F in repair EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour complete all as specified and directed.
Taking up or down 15 m bore GI steel tubing and connections including cleaning if refixing required complete all as specified and directed.
Taking up or down 20 mm bore GI steel tubing and connections including cleaning if refixing required complete all as specified and directed.
Taking up or down 25 mm bore GI steel tubing and connections including cleaning if refixing required complete all as specified and directed.
S&F 15 mm bore GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20 mm bore GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25 mm bore GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors complete all as specified and directed.
Refixing 15 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Refixing 20 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Refixing 25 mm bore old steel tubing and connections in new or old position (wall, floor, ceiling etc) complete all as specified and directed.
Dismantling water tanks of any description, capacity exc 500 and not exc 1000 litres and removing from site complete all as specified and directed.
Dismantling water tanks of any description, capacity exc 1000 and not exc 2000 litres and removing from site complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)1000 litre capacity hoisted and fixed in position complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)2000 litre capacity hoisted and fixed in position complete all as specified and directed.
S&F in repair Ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 20 mm bore of pipe complete all as specified and directed.
S&F in repair\ Ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 25 mm bore of pipe complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mm bore of pipe complete all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for iron pipe of 25 mm bore of pipe complete all as specified and directed.
S&F in repair for 15mm bore of pipe pillar taps cast copper alloy, with capstan head chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair Stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions for 15 mm bore of pipe complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc of tank capacity exc 500 litres and not exc 1000 litres complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tank and from mouths of circulating pipes etc of tank capacity exc 1000 litres and not exc 2000 litres complete all as specified and directed.
S&F in repair bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated of 15 mm bore of pipe complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate, in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 Type B-2 using 40mm graded stone aggregate in pavement/hard-standing laid in alternative panels, surface finished even and smooth without using extra cement, including necessary form work, complete all as specified and directed.
M & L 100 mm thick PCC 1:3:6 type C-2, using 40 mm graded crushed stone aggreates as in flooring finished even and fair complete all as specified and directed.
M&L 50 mm thick Sand cushning below interlocking paver tile complete all as specified and directed.
Machine pressed precast concrete interlocking paver block any shape and size fixing with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed.
S&F CP 2 way bib cock complete all as specified and directed.
S & F in repair Lid/cover of water tank capacity of 1000/500Ltrs including necessary cleats/clamps complete all as specified and directed.
S&F in repair PVC waste pipe for urinal/WHB/sink complete all as specified and directed.
S&F SS toilet paper holder with flap complete all as specified and directed.
S&F in repair Waste fittings 32 mm dia, brass, chromium plated for sinks/basins etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 100 mm internal dia of pipe complete all as specified and directed.
M&L for 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed.
M&L for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius with out access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius with out access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 90 gms) complete all as specified and directed.
S&F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190 gms) complete all as specified and directed.
S&F soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F CP Wall mixture complete all as specified and directed.
S&F glass shelf assembly consisting of 5.5mm thick sheet 12 cm wide with chromium plated bracket guard railing 60cm long complete all as specified and directed.
S&F cornner glass shelf of size 9"*9" shelf and frond,circle in design fixed over chromium plated brackets of heavy duty with frond linings with glass fixed in wall with necessary screws complete all as specified and directed.
S&F stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nut and securing ends of stays to wall or roof for 50 mm bore of pipe complete all as specified and directed.
Removing / taking out plants roots prtrouding from wall / vertical surfaces / horizontal surfaces in including removal of roots cleaning and making good by applying bonding agent algibound fepx algi coal ec 100,filling with cement mortar 1:4 with using water proofing compound complete all as specified and directed. (NOTE:- The quoted rate including water proofing compound)
S&F vitreous china wash down water closed white/colour cascade EWC incl necessary fittings seat cover in built flushing cistern and making good the disturbed surfaces complete all as specified and directed.
S&F table top WHB cascad oval counter top WHB coloured 550 x 490mm complete all as specified and directed.
Demolition of brick work / stone boulder masonry built in cement mortar complete all as specified and directed.
M & L brick work with fly ash bricks, Straight or curved on plan exc 6m mean radius,built in CM 1:6 complete all as specified and directed.
Use and waste of form work to soffits of supended slabs such as roof slabs, floor slabs, landings and similar works n.exc 200mm thick (Horizonal or slopping) for rough finished surface of concrete complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type B-0 1:2:4 (using 12.5mm graded stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M&L for mild steel TMT bars, 5mm dia and over upto and incl 10 mm dia in spacers, stirrups and binders , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to Fe-410-W or Fe 290 (as in rungs/handles) complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
M&L rendering 15mm thick in CM 1:6 to brick work or concrete surface finished even and smooth with out using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in two layers with 10 mm thick in CM 1:6 and top 5 mm thick in CM 1:4 finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of white wash over a coat of primer complete all as specified and directed.
M&L wire brushing and cleaning top surface of cement concrete including flashings and junction of parapet etc. and surface painting with a layers of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m. blinded with grit or pea size gravel @ 0.006 cu.m. per sqm and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed.
M&L for PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using (12.5mm graded stone aggregate ) as in sunken floor mixed water proofing compound @ 3% by weight of cement content,finished surface even and smooth with using extra cement complete all as specified and directed. Note : water proofing compound shall be measured seperatly.
M&L rendering 15mm thick cement plaster as in brick/concrete surface of sunken portion using water proofing compound @3% by the weight of cement content in cement mortar 1:3 complete all as specified and directed. Note : water proofing compound shall be measured & paid seperately
Taking down carefully old UNSV aluminium point wiring with wooden batten /concealed and all accessories of (light, fan, socket or power) such as switches socket ceiling rose, fan regulators, light fitting, main switches DB’s etc and making good disturbed surface complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC conduit duly concealed continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light/Call bell point controlled by one, one way switch.
One fan point controlled by one, one way switch.
One exhaust fan point controlled by one, one way switch.
One 5 Amp socket point controlled by one switch on independent board
One 5 Amp socket point controlled by one switch on same board
All as per Item No.93 above but with cable PVC insulated 4.0 Sqmm in and including PVC Conduit incl continuous earthing with cable PVC insulated 2.5 Sq mm copper conductor for power socket 15Amps complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC casing caping duly fixed on walls continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire , MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.
One fan point controlled by one switch.
On 3 pin 5 Amps socket outlet point on independent board
On 3 pin 5 Amps socket point on the same board
One light point controlled by two two way switches
All as per Item No. 99 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket complete all as specified and directed.
M&L for point wiring in existing conduit with PVC insulated, unsheathed, single core multistandard copper conductor cable 1.5 Sqmm, stranded copper conductor in and including PVC insulated 1.5 Sq mm copper conductor cable for earth continuity wire and MS box including laminated top sheet cover,washer & screw complete all as specified and directed. for One light point controlled by one, one way switch.
One fan point controlled by one switch.
On 3 pin 5 Amps socket outlet point on independent board
On 3 pin 5 Amps socket point on the same board
One light point controlled by two two way switches
All as per Item No. 105 above but with cable 4 sqmm including 2.5 sqmm cable as earth wire for 15/16 amp socket complete all as specified and directed.
S&F switch socket combination 2-in-1, 5 pin 5 Amp complete all as specified and directed.
S&F switch socket outlet 5 pin 5 Ampcomplete all as specified and directed.
S&F switch socket combination 2-in-1, 5 pin 5 and 15 Amp complete all as specified and directed.
S & F switch piano (Flush type) 5 amps, 240 Volts, single pole one way complete all as specified and directed.
S & F switch piano (Flush type) 5 amps, 240 Volts, single pole two way complete all as specified and directed.
S&F modular socket 6A , 2/3 pin combined 2 module complete all as specified and directed.
S&F modular switch 6A complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular socket 6A / 16A , 2/3 pin combined 2 module complete all as specified and directed.
S&F modular 6A 1 module 2 way switch complete all as specified and directed.
S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC complete all as specified and directed.
S & F for Bell push modular 6 Amps single module complete all as specified and directed.
S&F modular Ceiling rose 3 termianl complete all as specified and directed.
S&F modular white cover plate with frame for module 3 incl modular metal flush box complete all as specified and directed.
All as per Item No. 124 above but for 6 module complete all as specifed and directed.
All as per Item No. 124 above but for 8 module complete all as specifed and directed.
All as per Item No. 124 above but for 12 module complete all as specifed and directed.
All as per Item No. 124 above but for 18 module complete all as specifed and directed.
S&F Bakelite Sheet cover plate of size (5x5) complete all as specified and directed.
S&F Bakelite Sheet cover plate of size (8x5) complete all as specified and directed.
S&F Bakelite Sheet cover plate of size (11x13) complete all as specified and directed.
S& F in replacement of PVC Gang box Square type for fittings complete all as specified and directed.
S& F in replacement of PVC Board box of following Size complete all as specified and directed. (4x4)
All as per Item No. 133 above but size :- (6x8)
All as per Item No. 133 above but size :- (8x10)
S&F ceiling rose, bakelite three terminal complete all as specified and directed.
S & F bell ding dong electric single phase 240 Volt. complete all as specified and directed.
S & F ceiling fan regulator electronic step type socket mounting type complete all as specified and directed.
S & F in repair LED light fitting 18/ 20 Watt T5 batten type,PVC extruded batten with decorative end caps complete with polycarbonate /glass tube 4Ft White , internally pre-wired and including connecting up with suitable twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S & F in repair of light fittings (2Ft) with wall mounted LED pattern with polycarbonate housing & integrated electronic driver of 9W cap T5(max lenght upto 600mm) complete all as specified and directed. (Note : Contractor shall submit warratny for 03 yrs)
S&F in repair LED Porch light/surface mounting downlighter type with round surface,PDC Al housing light fittings of 10 W cap 3000K incl taking down the old unsv complete all as specified and directed. (Note : must for warrenty of 3 yrs to 5 yrs)
S&F in repair recess mounting LED low forfole slim fit downlights with high lumin out put of 12 wats cap with celing cutout 160mm oval/round of ht 25mm complete prewired incl necessary electrical connections complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 36W, sIze 2'x2' including taking down the old rusted tube light fitting complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x2' including taking down the old rusted tube light fitting complete all as specified and directed.
S & F in repair recess mounting LED Endura slim pro plus ceiling light suitable for armstrong/grid ceiling complete capacity 24 W, sIze 1'x1' including taking down the old rusted tube light fitting complete all as specified and directed.
S&F in repair Globe Decorative wall light fixture made up of Polycarbonate,suitable for LED incl LED Bulb 10W B-22 Series complete all as specified and directed.
S&F in replacement of bldg security light fitting LED type of 20 watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDs as light source and electronic driver. mounting bracket suitable to house the light fittinhg , with its Galvanised Flat Iron clamps conntected nuts bolts etc complete all as specified & directed. (Note : must for warrenty of 3 yrs to 5 yrs)
M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 4.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 2.5 Sq mm, stranded copper conductor complete all as specified and directed.
M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 1.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 2.5 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 1.5 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 6.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L in replacement of 2 Runs of cable PVC insulated but unsheathed 10 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 6.0 Sq mm, stranded copper conductor complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S& F in replacement 3 core 1 Sqmm round Sheathed copper wire complete all as specified and directed.
S & F in replacement of sheet metal enclosure vertical DBs with provision for FP MCCB frame upto 100A in 16,KA as incomer 4 way double door made complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door MCB DB, SPN 12 way complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door MCB DB, SPN 8 way complete all as specified and directed.
S & F in replacement of sheet metal enclosure double door MCB DB, TPN 4 way complete all as specified and directed.
S & F in replacement of MCCB 100 Amps 4 Pole 25 KA 415Volts complete all as specified and directed.
S & F in replacement of MCCB 63 Amps 4 Pole 16 KA 415Volts complete all as specified and directed.
S & F in replacement of TPN 40 Amps 415Volts complete all as specified and directed.
S & F in replacement of TPN 63 Amps 415Volts complete all as specified and directed.
S & F in replacement of MCB SPN 16 TO 32 Amp 10 KA 240 Volts complete all as specified and directed.
S & F in replacement of MCB, SP 6 to 30 Amp 240 Volts rating complete all as specified and directed.
S&F in replacement of exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and directed.
S & F in minor repairs to FTL fittings by replacing bi-pin holders, connectors , tube rods chokes of any type and capacity etc complete all as specified and directed. Note : Tube rods and chokes are measured separately
Supply only Electronic Ballast suitable for 36/40 watts FTL conventional light fittings complete all as specified and directed.
Supply only Electronic Ballast suitable for 28 watts FTL conventional light fittings complete all as specified and directed.
Supply only tube rod 36/40watt for 4 feet tube light fittings complete all as specified and directed.
Supply only tube rod 28 watt for 4 feet tube light fittings complete all as specified and directed.
S&F in replcment of single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed.
M&L for replacement of earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level)with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers protected with & including 15 mm dia light grade GI pipe necessary excavation and earth works, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light grade including PCC pit with Pre cast RCC (1:2:4) cover, GI funnel with mesh test point, testing & commissioning complete all as specified and directed.
HARAGOURI SUPPLIERS
DHABALESWAR ENGINEERING WORKS
M/s Ats Electricals
R K Traders
G.KRISHNA MURTHY AND PARTNERS
M/S JAGANNATH SASMAL
M/S SIWALIK AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .