Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹37.9 L+₹2.7 L (7.61%)Rejected-Finance 815 TAILAK MANNA STREET MANNAPARA MONIRAMPORE BARRACKPORE NORTH 24 PARGANAS WB 700 120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹38.6 L+₹3.4 L (9.74%)Rejected-Finance 79 O P ROAD NAYABASTI BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | DAS ENTERPRISE L1 | SUROJIT GHORUI L2 | SHIVAM ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed. | 351 | Cum | 700 ₹2,45,700 Lowest | 859 ₹3,01,509 | 865 ₹3,03,615 |
| 2.00 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed.
NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications. | 2 | Cum | 300 ₹600 Lowest | 360 ₹720 | 370 ₹740 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed. | 199.19 | Cum | 400 ₹79,677 Lowest | 542 ₹1,07,962.33 | 549 ₹1,09,356.68 |
| 4.00 | Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed. | 129.65 | Cum | 288 ₹37,339.2 Lowest | 311 ₹40,321.15 | 325 ₹42,136.25 |
| 5.00 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. | 105.3 | Cum | 2,100 ₹2,21,130 Lowest | 2,329 ₹2,45,243.7 | 2,335 ₹2,45,875.5 |
| 6.00 | Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed. | 11,240 | Each | 10 ₹1,12,400 | 7 ₹78,680 Lowest | 8 ₹89,920 |
| 7.00 | Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 9.00 here-in-after), for Cable Protection, complete all as specified and as directed. | 10,000 | Each | 3 ₹30,000 Lowest | 4 ₹40,000 | 5 ₹50,000 |
| 8.00 | Taking out of interlocking paver block, any shape or size and Re-laying the same after laying of LT cable of any size and also removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed.NOTE : Sand, if required for connection of cushioning level will be measured and paid seperately. | 100 | Sqm | 185 ₹18,500 Lowest | 200 ₹20,000 | 230 ₹23,000 |
| 9.00 | Supply and Laying of Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed. | 100 | Sqm | 840 ₹84,000 Lowest | 913 ₹91,300 | 924 ₹92,400 |
| 10.00Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench/pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- Note :- Necessary earth work to be measured and paid separately. | ||||||
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
2 Sept 2025, 12:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF LT CABLES, SWITCH GEARS AND LT PANELS AT JSSC AND DIFFERENT MD ACCNS OUTSIDE VIJAY DURG UNDER GE (FW) KOLKATA
2025_MES_724738_1
8450/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹63,000
29 Sept 2025
6 Aug 2025
3 Sept 2025
6 Aug 2025
2 Sept 2025
19 Aug 2025
Amount
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth and getting out, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be included Materials and Labour required for repairing to damaged Road/ Hardstanding to match the existing Surfaces and Specifications.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180Cm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 9.00 here-in-after), for Cable Protection, complete all as specified and as directed.
Taking out of interlocking paver block, any shape or size and Re-laying the same after laying of LT cable of any size and also removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed.NOTE : Sand, if required for connection of cushioning level will be measured and paid seperately.
Supply and Laying of Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench/pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- Note :- Necessary earth work to be measured and paid separately.
10 Sqmm 4 core to 16 Sqmm, 4 core
25 Sqmm to 50 Sqmm, 3.5 Core
70 Sqmm to 150 Sqmm, 3.5 Core
185 Sqmm to 400 Sqmm, 3.5 Core
Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :- Note :- Necessary earth work to be measured and paid separately.
10 sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 4 core
50 Sqmm, 4 core
70 Sqmm, 4 core
95 Sqmm, 4 core
120 Sqmm, 3.5 Core
185 Sqmm, 3.5 Core
240 Sqmm, 3.5 Core
400 SQMM 3.5 CORE
M&L for Relaying XLPE Under Ground Cable of any description (Serviceable Cable obtained from Item No. 6.00 here-in-before) 1100 Volt grade, after Fault rectification including necessary Aluminium Thimbles, jointing and Testing, complete all as specified and as directed of the following cross sectional area :-
10 Sqmm to 16 Sqmm 2/3½/4 Core
25 Sqmm to 50 Sqmm 3½/4 Core
70 Sqmm to 150 Sqmm 3½ Core
185 Sqmm to 240 Sqmm 3½ Core
300 Sqmm to 400 Sqmm 3½ Core
Dismantling/ Disconnecting electric connection of underground LT, XLPE Cable, 1100 volts upto 35 to 400 Sqmm from both sides and locating the fault in LT cable with fault locating machine in the entire length up to 1 Km complete testing after reconnecting and commissioning of cable complete all as specified and as directed. Note : The work will be executed after obtaining proper shutdown from Substation liase with JE E/M.
Supply and fix (in replacement) ACB, 800 amps, 4 pole, with microprocessor based release, Ics=50% of Icu, manual drawout type, with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1, internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing ACB complete all as specified and directed.
S&F in repairs of MCCB, 630 amps, 4 pole, 50 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1 , internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing MCCB complete all as specified and directed.
S&F in repairs of MCCB, 400 amps, 4 pole, 50 KA, with microprocessor based release with electronic Sg (LSIg) protection unit, Ics=100% of Icu with overload, short circuit & ground fault protections with inbuilt display for current metering with high accuracy of class 1 , internal battery, communication port, inbuilt USB port for software diagnosis, all accessories incl taking down existing MCCB complete all as specified and directed.
S&F in repairs of MCCB 4 Pole, 415 V, Adjustable type 320 Amps with breaking capacity 36 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, Adjustable type 250 Amps with breaking capacity 36 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, Adjustable type 200 Amps with breaking capacity 36 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, Adjustable type 160 Amps with breaking capacity 36 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, 100 Amps with adjustable type, breaking capacity 25 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, 63 Amps with adjustable type, breaking capacity 25 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
10 Sqmm to 16 Sqmm, 4 core
25 Sqmm to 50 sqmm 3.5/4 core
70 sqmm to 150 sqmm, 3.5 core
185 sqmm to 240 sqmm, 3.5 core
300 sqmm to 400 sqmm, 3.5 core
S&F Cable Route Indicator made out of Cast Iron plate 80 mm dia fixed with MS angle iron 40x40x6mm having 60 Cm long showing MES LT Cable Size with voltage with two coats of synthetic enamel paint in blue colour over one coat of primer necessary Earth Work and Cement Concrete 1:2:4 (20mm graded crushed stone aggregates) Block of size 20x20x20 Cm including Taking out Unserviceable Cable Route Indicator, complete all as specified and as directed.
Material & Labour for PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs, as in repairs, complete all as specified and directed by the Engr-in-Charge.
S&F in repairs Street light junction box made out of 3 mm thick mild steel sheet including applying two coats of synthetic enamel paint over a coat of zinc chrome primer duly spray painted of size not less than 30 cm x 25 cm x 20 cm with locking arrangements inclusive of 20 x 3 mm thick aluminium bus bar 100 amps-04 Nos of suitable length incl MCB SP 5 amp - 01 No, fixed on and including insulators for mounting bus bar (with provision of cable entry and exit conduit), fixed at bottom portion of the pole, fixed with GI bolts, nuts and washers (of suitable size), incl taking down existing junction box complete all as specified and as directed by the Engineer-in-charge .
Dismantling carefully serviceable isolating LT Panel board of sizes 500mm x 500mm x 500mm to 1800mm x 2000mm x 600mm, duly unscrewing/ opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts incoming and outgoing terminals including cleaning the all switchgear/ accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board ater scrubbing/ cleaning the surface complete testing the Panel board till satisfaction of Engr-in-Charge, complete all as specified and directed. Note: -(i) Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate. (ii) Quantity of stainless steel hinges as per site requirement shall be deemed to be included in the quoted rate.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
SUROJIT GHORUI (BID ID -3406333)
SHIVAM ENTERPRISE (BID ID -3406321)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .