| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJ 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Lowest Acceptance Bidder | |
| 2 | L2₹52.9 L+₹4.1 L (8.42%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Higher Rate quoted. | |
| 3 | L3₹54.0 L+₹5.2 L (10.7%)Rejected-Finance 1472 14TH FLOOR AGARWAL CYBER PLAZA II NETAJI SUBHASH PALACE PITAMPURA NEW DELHI 110034 | NEW DELHI | NORTH WEST DELHI | DELHI | 110034 | L3 | Rejected-Finance Higher Rate quoted. | |
| 4 | Rejected-Technical N A | NA | NA | 121004 | - | Rejected-Technical Two class below enlisted |
Tender Value
₹52.5 L
EMD Value
₹1.0 L
Closing Date
13 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bikaner
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Spl repair to family Qtrs block No P-25 (01 to 10) and Provn of 01 Gd Room with attached toilet including verandah at Bikaner Mil Stn under GE (N) Bikaner
2022_MES_562473_3
CA No. CWE BKN-Token No. 38/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Bikaner
As per Tender Documents
7 documents required · 7 mandatory
₹1,000
GE (N) Bikaner
₹1.0 L
Yes
11 May 2023
21 Feb 2023
15 Mar 2023
21 Feb 2023
13 Mar 2023
1 Mar 2023
21 Feb 2023 - 27 Feb 2023
Amount
Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition) not otherwise specifically provided for in this Schedule, complete all as specified & as directed. Note : Contractor shall make arrangement to protect tiles, plumbing items, sanitary fittings, etc under the slab, etc by gunny bags with sand or any other suitable arrangement and quoted rates shall deemed to include this aspect.
Demolition of unreinforced cement concrete of any description and in any position (not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
Demolition of lime concrete of any description and in any position (not otherwise specifically provided for in this Schedule, complete all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or any thickness in floors, aprons etc, laid bedded and pointed in any mortar, complete all as specified & as directed.
Dismantling boarding, any description, fixed in any position with nails/screws complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layer on roofs, complete all as specified and as directed. Note : Tiles shall be dismantled carefully and stacked properly including segregating the serviceable & unserviceable tiles as directed. Serviceable tiles shall be reused under the respective item of this Schedule.
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts or dismantling brick work (holes cur and any other damage to jambs, wall) and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts or dismantling brick work (holes cur and any other damage to jambs, wall) and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and as directed.
Earth filling under floors or in foundations and similar locations including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. Note :- Soil obtained from excavation under serial item No. 13.00 here-in-before shall be used for filling under floors.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:3:6 type C0 (using 12.5mm graded crushed stone aggregate) as in filling up chowkat/frame hollows and similar works complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in sub base of flooring finished even and smooth without using extra cement complete all as specified.
M&L for factory made 60mm thick machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed. Note : Shape of paver blocks shall be as approved by the GE.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts, struts and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.
M&L for Damp proof course to horizontal or vertical surfaces, 40mm thick in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate, using integral liquid water proofing compound, including necessary formwork, complete all as specified and as directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.
M&L for roughly squared stone lintels, hammer dressed on face and soffits, hoisted, set and pointed in cement mortar 1:4, not exceeding 3m in length, complete all as specified & as directed.
M&L for stone slab 25mm to 35mm thick dressed true and square, in one length not less than 60cm and not exceeding 120cm in copings, window cills, chajjas, sunshades, etc., punched dressed on exposed faces and self faced on the embedded unexposed beds and joints, exposed edges rounded or chamfered as directed, set, jointed and pointed in mortar 1:4 complete all as specified and as directed.
M&L for 7.5cm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:4, complete all as specified and as directed.
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide for rough finished flat surfaces of concrete complete all as specified & as directed.
Supply and fixing factory made 30 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.
Supply and fixing factory made 30mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed.
Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour single piece extruded PVC profile reinforced with MS square tube, fixing in opening as per specifications complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with plain colour single piece extruded PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour single piece extruded PVC profile for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed..
M&L for 18mm thick single side prelaminated wood grain solid PVC sheet suitable fixed in shelves, partitions and shelves of built in cupboards, almirahs, book cases, toilets boxes, racks, pelmets and similar work etc with & including necessary hardwork fittings (stainless steel auto hinges, stainless steel designer handle, locking arrangement) complete all as specified & as directed.
Taking down & out loose & damaged concrete/cement plaster from soffits of ceiling, floor/RCC roof slabs, vertical surfaces of columns, beams etc including exposing and removing rust from the reinforcement by rubbing with wire brush and removal of debris to a distance not exceeding 100m and depositing complete all as specified and as directed.
M&L for cleaning existing reinforcement bars with wire brush / rotary wire brush making the surface free from cement skin, loose particles, dirt, etc and applying rust remover ('Rustoff 100' of Sika / '8832 GM' of Pidilite or equivalent of Fosroc / Dr. Fixit) on the rebars and removing the loose rust particles after minimum 24 hours by wire brush, all as per manufacturer’s instructions, complete all as specified and as directed. Note : Mode of measurement shall be affected surface area of column, beam, slab, etc.
S&F hard drawn steel wire fabric, weight not exc 4 Kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, supplied and fixed in reinforcement, complete all as specified & as directed.
M&L for cement based polymer modified anti corrosive rebar coating system ('SikaTop Armatec-108' of Sika or equivalent of Dr. Fixit / Fosroc) to existing reinforcement all as per manufacturer’s instructions, complete all as specified and as directed. Note : Mode of measurement shall be affected surface area of column, beam, slab, etc.
M&L for one layer of 20mm thick concrete {comprises composition 1:2:1 plain cement concrete i.e. one part of cement (43 Gde OPC), two parts of fine aggregate and one part of 10mm and down size trap stone aggregate} mixed with 'Sprayset SL' of Fosroc (or equivalent in Sika / Dr. Fixit) 2.00 to 2.50% by weight of cement and 12.50 to 16.50 litre of water mixed as per manufacturer’s instructions and guniting by pressure nozzle with a delivery capacity of 2.5 Kg per Sqm over column, beam, roof slab, etc, complete all as specified and as directed.
S&F butt hinges of size 100mm stainless steel ISI marked complete all as specified and as directed.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified and directed.
Supply & fixing butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin type B-21 anodised complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed.
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F 150 mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified and as directed.
S&F 150mm size aluminium handle, cast type, anodised, complete all as specified & as directed.
S&F 150mm size Extruded aluminium handle, fabricated type, anodised, complete all as specified & as directed.
S&F mild steel pressed handle, 150 mm size, oval type, stove enameled black complete all as specified and as directed.
S&F in repair mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & as directed.
S&F stainless steel drapery rod of 25mm inner dia & 1.6mm wall thickness (in lengths as directed) with & including stainless steel sockets & decorative finial at both ends and pair of stainless steel brackets & stops fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F in repairs mild steel chromium plated tubular curtain/drapery rod 20mm dia (in lengths as directed) with & including pair of projecting type fancy mild steel chromium plated brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F 250 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F 250 mm long mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed.
Supply and fixing Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
All as per serial item No. 67.00 here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified.
S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.
S&F factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.
S&F factory fabricated pressed steel frame/box windows, ventilators with glazed and fly proof shutters provided to size and dimensions as specified & shown on drawing No. BTD-888R Sheet No. 1/5 to 5/5 & BTD-889 Sheet No. 1/4 to 4/4 with & including MS grill, MS fillets, pintol hinges, tower bolts, MS handles, peg stays, MS lugs, locking arrangement, dash through bolt where required, etc complete all as specified & as directed. Notes : (i) PCC for filling in frames, glass, wire gauge and painting shall be measured & paid for separately under respective items. Provision of all other items as shown & specified on drawings shall deemed to be included in quoted rate of this item. (ii) The quoted rate shall deemed to include provision of cutting holes of suitable depth in walls for inserting lugs etc and making good dismantled portion in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate and CM (1:3).
M&L for 10mm thick plaster (screed bed) over roof slab in CM 1:4, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and as directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 litre/sqm and provide a layer of APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick, reinforced with polyester non woven fabric (weighing not less than 150 gms/sqm) laid on primed surface complete all as described in Para 11.44.5 of SSR Part-I, complete all as specified and as directed. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps.
M&L for preparing surfaces of concrete roof slab by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.20 Kg per sqm including cleaning surfaces and provide a layer 150 micron polythene sheet laid on primed surface, complete all as specified and as directed. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps.
M&L for Lime concrete terracing as specified in roof complete all as specified & as directed. Note : For lime concrete, mudia kankar (Source : NAL) and Kolayat coarse sand in lieu of brick aggregates and Surkhi respectively as specified in MES Schedule Part-I shall be used.
M&L for 40mm thick brick tiles, joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, laid on roof over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed.
All as per serial item No. 76.00 here-in-before but except brick tiles complete all as specified & as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified & as directed.
M&L for Flush pointing in cement mortar 1:4 to bricks laid flat or brick tiles in pavings, floors, surface channels, roofs, etc, complete all as specified & as directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base in floor, surface finished fair and even complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for machine cut Kota stone slab 18 to 20mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in cooking platform & similar works and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for Non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for Non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for Non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 450mm x 300mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in plinth protection/ hard standing surface finished even and smooth without using extra cement complete all as specified and directed. Note :- Plinth protection/hard standing shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for 10mm thick rendering in cement and mortar 1:3 in sunken portion, mixed with liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for removal of loose concrete and cleaning the surfaces and filling the cracks with Polymer modified mortar using Dr Fixit Pidicrete URP or other equivalent product as approved by GE and thereafter applying two coats of Dr Fixit Bathseal WPC or other equivalent product as approved by GE in Sunken areas complete all as per manufacturer’s instructions, specified & directed. Note : Where contractor desire to use equivalent product of Dr Fixit Pidicrete URP and Dr Fixit Bathseal WPC, he shall submit the technical literature of equivalent products to establish the equivalency of products to the entire satisfaction of GE and both products shall be of same manufacturer as approved by the GE.
M&L for 15mm thick rendering in two layer on concrete surfaces of chajjas consisting of 1st layer of 10mm thick plaster in CM 1:4 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4, 2nd layer mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished fair & even, complete, all as specified and directed. Note : - Supply only liquid water proofing compound shall be measured and paid for separately.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of ceiling and applying two coats of white wash complete all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty on walls complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
M&L for preparation of plastered surfaces and applying two coats of Exterior emulsion paint/ weather proof exterior grade paint of approved shade/tint over a coat of suitable priming paint on walls/ceiling/fascia/chajja/pillars including filling of cracks with smooth finished wall care putty complete all as specified and as directed.
M&L for complete removal of existing treatment of walls/ceiling including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of Exterior emulsion paint/ weather proof exterior grade paint of first quality by using of approved shade/tint over a coat of primer including sealing the cracks all as specified in manufacturers instruction Make : STP Ltd / Asian Paint (Apex Ultima) / Berger Paint (Weather coat long) complete all as specified and directed.
Supply and fixing 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces complete all as specified.
S&F 4mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane, complete all as specified and as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 15mm bore complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 15mm bore obtained serviceable vide serial item No. 109.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 20mm bore complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 20mm bore obtained serviceable vide serial item No. 112.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings complete, laid in trenches, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for galvanized steel water tubing medium grade of 25mm bore with & including all fittings complete, laid in trenches, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for galvanized steel water tubing medium grade of 40mm bore with & including all fittings complete, laid in trenches, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 25mm bore pipe fixed complete all as specified and directed.
M&L for Gun metal globe or gate valve, with iron wheel head, screwed both ends, ISI marked for 40mm bore pipe fixed complete all as specified and directed.
Supply & fixing mild steel clamps made of flat iron 50x6mm in two halves for tapping through 100 to 200mm bore GI/CI/DI water pipe line including made to shape, drilling and welding of 25mm GI socket and necessary rubber insertion, nut, bolts & washers complete all as specified and as directed.
Disconnecting & taking down the existing unserviceable water tank with ball valve and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
S&F in repairs Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed in repair complete all as specified and as directed.
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed in repair complete all as specified and as directed.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 550x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
S&F vitreous china squatting pan (Orissa pattern) water closet (white) of size 550x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity connected to water closet with inlet, ball valve, float and handle complete all as specified & as directed.
S&F PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity connected to water closet with inlet, ball valve, float and handle complete all as specified & as directed.
S&F in repairs vitreous china wash hand basin, white, flat back of size 580mm x 450mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
S&F vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, including CP pillar tap heavy duty with PVC connetion and including 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
S&F vitreous china urinal, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified.
S&F sink made of stainless steel 1mm thick for Kitchen or laboratory with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to brick wall, connecting union to pipe, overall minimum size 495mm x 420 mm with bowl size 410mm x 330mm x160 mm including 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, including taking down old unserviceable sink with fittings complete all as specified and as directed
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes, complete all as specified & as directed. Make : Cat Part No. ‘G4902A1’ of ‘Parryware’ / Cat Part No. ‘F2002101’ of ‘Cera’ / Cat Part No. ‘CQT-23011B’ of ‘Jaquar’ / Cat Part No. ‘9202’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F 15mm bore fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore complete all as specified and directed.
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed.
S&F in repairs 15 mm bore bib tap, brass, chromium plated, long body, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule, including CP brass wall flange, complete all as specified & as directed. Make : Cat Part No. ‘G4906A1’ of ‘Parryware’ / Cat Part No. ‘F2002152’ of ‘Cera’ / Cat Part No. ‘CQT-23047’ of ‘Jaquar’ / Cat Part No. ‘9208’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F in repairs 15mm bore Stop valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 20mm bore Stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F 15mm bore Stop valve fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F 15mm bore Angle stop valve, fancy type and cup of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 15mm bore Angle stop valve, brass, chromium plated, fancy type, screwed down, high pressure with capstan head, screwed both ends for iron pipe or for union, including CP brass wall flange, complete all as specified & as directed. Make : Cat Part No. ‘G4907A1’ of ‘Parryware’ / Cat Part No. ‘F2002201’ of ‘Cera’ / Cat Part No. 'CON-059KN’ of ‘Jaquar’ / Cat Part No. ‘9210’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F in repair 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete, all as specified & directed.
S&F in repairs Overhead Shower rose, round type, brass, chromium plated, Fancy type, 125 mm dia (minimum) with 200mm long (minimum) shower arm or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe of 15mm bore or union complete all as specified and as directed. Make : Cat Part No. ‘T9809A1’ of ‘Parryware’ / Cat Part No. ‘F7010212AB’ of ‘Cera’ / Cat Part No. ‘BOS-87’ of ‘Prayag’ or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F chromium plated shower rose 125mm size with or without CP arms swivel joint, including fixing to steel pipe or union and fixed complete all as specified and directed.
S&F in repairs tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, fixed complete all as specified and as directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, fixed complete all as specified and as directed.
S&F in repairs Soap dish holder brass chromium plated fixed on wall with PVC rawl plug & cadmium plated brass screws complete all as specified & as directed.
S&F in repairs stainless steel Kitchen plate rack of overall minimum size 600mm x 900mm x 250mm, with partitions for small/large plates etc, made out of 0.63mm stainless steel sheet, fixed with rawl plug and CP steel screws complete all as specified and as directed. Make : Cat Part No. P-336 of Prayag or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 100mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.
S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 75mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed.
Supply and fixing 110 mm bore PVC (SWR) bends any radius complete all as specified.
Supply and fixing 75 mm bore PVC (SWR) bends any radius complete all as specified.
S&F in repairs 110 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal provided complete all as specified and directed.
S&F in repairs 75 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal provided complete all as specified and directed.
Supply and fixing PVC (SWR) vent cowl for 110mm bore pipe complete all as specified.
Supply and fixing PVC (SWR) vent cowl for 75mm bore pipe complete all as specified.
S&F PVC (SWR) floor trap dia of outlet 75mm, with PTMT grating including jointing with solvent cement including taking out old unserviceable trap complete all as specified and directed.
M&L for 150mm bore reinforced concrete pipe, class NP2, laid and jointed complete with collars, laid and jointed on concrete bed complete including testing, and including demolition and breaking up drain pipes set in cement mortar complete all as specified & as directed. Note :- Excavation & earthwork shall be measured and paid separately.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150mm bore pipe complete all as specified and as directed.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. including placing in position and set in CM (1:4) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule.
S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed. Note :- Excavation & earthwork shall be measured and paid separately.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls including dismantling & taking out or down old unserviceable 110mm bore PVC (SWR) drain pipe with fittings complete all as specified & as directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls including dismantling & taking out or down old unserviceable 75mm bore PVC (SWR) drain pipe with fittings complete all as specified & as directed.
Supply and fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
Supply and fixing 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F in repairs 32mm/38mm dia waste pipe fitting brass chromium plated for wash hand basin/ sink, complete all as specified and as directed.
S&F urinal spreader of PTMT any colour for fixing with 15 mm bore pipe (Minimum weight 60gms) complete all as specified & as directed.
M&L for Valve Pit of internal size 90cm x 90cm x 90cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2.
M&L for construction of Soak Well for 25 users, brick masonry, complete, all as specified and shown on drawings (BTD-830 Sheet No. 1/1).
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for Modular point wiring for one light /fan /bell /buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/ drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed. Notes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE.
All as per serial item No. 175 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 175 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 175 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F bell push, flush type, 5 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed.
S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed.
S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F Modular Fan step regulator, 120 Watt - 2 module, complete all as specified and as directed.
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, ISI marked, fixed in repairs, complete all as specified and as directed.
S&F LED mirror fitting 1x10 Watt, 6000 K, 2 feet, basic all purpose surface and wall mounted LED batten with powdered coated aluminium housing & integrated electronic driver & all accessories including connection with 2 core flexible copper cable 23/0.00076 from ceiling rose to fitting connection with following specification, complete all as specified and as directed :- (a) Lumen efficacy of system should be minimum 105 Lumen per watt. (b) Voltage operating range : 160 to 270 Volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection device for 2.5 KV. (l) CRI : Minimum 80 Make: Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH of Havells/ Model “LDL-10-WW” of M/S Crompton/ Cat Part No. LL20-111-XXX-65NE3/BCLSB or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Philips, Cat Part No. LED 20S PSU CW GR S2/ Crompton Greaves, Cat Part No. LDDR20-CDL Dazzle Ray/ Bajaj, Cat Part No. BCLAB 20W or equivalent make here-in-after in appendix 'B'
Supply, installation, commissioning & testing Light Emitting Diode (LED) based street light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 2500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), including taking down old unserviceable light fittings complete all as specified and as directed.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based street light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 2500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based Flood light fitting, 100 Watt with & including LED lamp, housing made up of LM6 pressure epoxy powder coated die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt, a minimum system lumen output of not less than 16500 lumens, Correlated Colour Temperature (CCT) shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 10%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/ polycarbonate/ toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed on wall with stand bracket for mounting of flood lights, complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, including taking down old bracket complete all as specified and as directed.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
Supply and fixing sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs, 415 Volts with 200 Amps rated bus bar, SPN, 12 way, suitable for MCBs, fitted with and accessories, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply and fixing MCCB TPN, DB, 4 way vertical type 440 volts, 03 Phase, IP-43 protection, IK-09 with rated bus bar 200 Amps, double door suitable for MCCB as in incomer and MCBs as out going, double door type, grouted in walls with accessories, including taking down old existing unserviceable DB with fixtures of any type complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs, 415 Volts with 200 Amps rated bus bar, SPN, 8 way, suitable for MCBs, fitted with and accessories, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
S&F MCB, 40 Amps, Double Pole, 415 Volts, 10 kA, ‘D’ Curve, with over load and short circuit protection, complete all as specified and as directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, complete all as specified and directed.
Supply and fixing Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, 300mm sweep, 230V, 50 Hz, 1200 RPM, Copper winding and connecting with & including 1.5 sqmm, three core, flexible multistranded copper conductor cable and connected from ceiling rose to fan complete all as specified & as directed.
Supply & fixing Exhaust fan of 300mm sweep made of steel body, heavy duty, double ball bearing, copper wound, steel body, 1200 RPM, Single Phase 230 Volt, 50 Hz AC supply complete with blades, frame and louver shutter and connecting up with & including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn into & including flexible PVC conduit and fixed by using 4 Nos, 100mm long 8mm dia bolt nuts and washers and grouted in wall in CM (1:3) complete all as specified & as directed.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CMM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed. Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates.
Supply, installation & testing electric Geyser (water storage type) of capacity 25 litre, vertical mounting type, glass lined inner tank, rust proof outer body, 2 KW heating element, suitable for 230 V Single Phase 50 Hz AC supply, 5 Star rating, energy efficient, 8 Kg/sqcm pressure withstanding capacity, Class I, ISI marked, with & including Thermostat with Thermal Cutout, heating indicator, Multi functional valve (acts as pressure release valve, non-return valve, expansion valve and vacuum release valve), fixed all as per manufacturer’s instructions, including PVC connection with brass nipple 15mm bore, 600mm long with ISI marked, stainless steel, suitable for hot and cold water for geyser fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original, complete, all as specified & directed. Make : Havells (Model No. Monza EC), Cat Part No. GHWAMFSWH025/ Bajaj Calenta Storage/ Crompton Solarium Qube.
S&F Evaporative Air Cooler in steel body (Desert Cooler) with propeller type cooler fan with motor (ISI marked) 1400 RPM (4 Pole) three speeds, nominal capacity 4000 Cum/hour, fan size 450mm, type of blade - Plastic (HIP), submersible water pump, filter pads, power consumption - 225 Watts (maximum), electric driven, single phase, 230 Volts, 50 Hz, capacitor 4 mfd, including all accessories, complete all as specified & as directed. Notes:- (i) Filter panels, front, grill and top of the cooler body shall be made of 0.80 mm galvanized steel sheet. The sump tank and rest of the body shall be made of 1.00 mm thick galvanized steel sheet. The galvanised steel sheet shall be ISI marked and shall have zinc coating not less than 100 gms/sqm and shall conform to IS : 277. (ii) All internal surfaces including inside of the tank, fan blades, motor body, pump, pump body and frame shall be painted with water resistant paint conforming to IS: 9862. The outer surface of the cooler shall be spray painted with synthetic enamel paint of approved shade/tint. (iii) The desert cooler shall be fitted with adjustable grill with separate on/off switch of 5/6 Amp rating (ISI marked) for cooler fan and water pump and three stage speed regulator (Low, Medium, High) for three speed cooler fan motor. (iv) Suitable nylon bushes shall be provided in the grill for easy and smooth movement of louvers. (v) The filter pads shall contain wood wool. The filter pads shall be fixed over the panel and secured by clamping guard of galvanized wire of 2mm dia (approx.) and net size 100 mm (approx.) square/rectangular. The wire guard shall be fixed in the clamps to avoid any sagging. (Description of serial item No. 209.00 contd…)
Description of serial item No. 209.00 contd… (vi) The drain plug of brass/stainless steel shall be fitted in such a way so as to be able to completely drain the water from the tank. (vii) The inside wiring connection shall be through suitable non-ferrous thimbles and the live contacts of rotary switch shall be protected by suitable enclosure of insulating material. The electrical cords of the motor and the pump shall be sheathed type. (viii) The cooler shall be provided with front filling arrangement and with 3 core copper stranded conductor size 23/0.0076 cable connecting cord (ISI marked) of 2.50 mtrs length fitted with 3 pin moulded plug top of 5/6 Amp rating (ISI marked). (ix) PVC pipe 15mm bore shall be heavy duty high density. (x) Overall minimum dimensions including water tank (sump) of the cooler shall be as under :- (a) Width – 660 mm (measured at front side) (b) Height – 860 mm (measured at front side) (c) Depth – 660 mm (d) Height of water tank – 228 mm (xi) Cooler fan with motor and submersible pump shall be of make :- Khaitan / Usha / Bajaj / GEC / Crompton / Orient / Polar / Havells. Makes of other material such as switches, copper cord etc shall be as specified in Particular specifications / Appendices. (xii) Above aspects shall deemed to be included in quoted rates.
Taking down geyser of any capacity from wall and refixing of geyser with including fixing arrangement complete all as specified and directed.
Taking dwon and refixing tamper proof energy meter electronic type single phase 10-60 Amps current rating single phase 230 Volt AC with electric connection and necessary fixing arrangement complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete including dismantling & taking down old unserviceable sub main wiring complete all as specified. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including taking down old unserviceable cable complete all as specified and as directed. Note :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 6 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified. Note : -(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI pipe complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M/S BUDHRAM BISHNOI
Ram Parkash Constructions Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .