Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr Quoted ₹3.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹3.5 Cr+₹30.6 L (9.59%)Rejected-Finance | ₹3.5 Cr+₹30.6 L (9.59%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹4.0 Cr+₹77.4 L (24.2%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | ₹4.0 Cr+₹77.4 L (24.2%) | L3 | Rejected-Finance Being L3 |
Tender Value
₹4.2 Cr
EMD Value
₹4.9 L
Closing Date
7 Feb 2024, 6:00 pmClosed
Chief Engineer Lucknow Zone,
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt PIN -226002
ADDITION/ALTERATION CUM SPECIAL REPAIRS TO VARIOUS STORAGE SHEDS OF OD FORT PRAYAGRAJ.
2023_MES_632102_1
CELZ/PRG/T-08 OF 2023-24
Open Tender
Civil Works
Item Rate
540 days
Prayagraj
As per NIT
8 documents required · 8 mandatory
₹2,000
Yes
GE (E) Prayagraj
₹4.9 L
Yes
30 Mar 2024
11 Dec 2023
14 Feb 2024
11 Dec 2023
7 Feb 2024
24 Jan 2024
Amount
B&R WORKS Dismantling of AC sheet (corrugated or semi corrugated etc) including AC ridges as in roof covering complete all as directed.
Material & Labour for 6 mm thick asbestos cement corrugated or semi corrugated sheet as in roof covering, walls etc fixed with L or J type hooks or cranked bolts complete all as specified & directed.
All as per Item No 2 here-in before but except AC sheet (Note :- AC sheet shall be reused retrieved from dismantling from item No 1 here in before.)
S& F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed.
S&F 1.00 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories
S&F in repair Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed
S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
Demolition of brick work or stone/boulders masonary built in cement mortar including all quoins arches pillar etc but excluding Ashlar facing, droved stone work and forecast concrete articles complete all as directed.
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, laying of pipes & cable etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cespits, manholes pier hold etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard / dense soil
Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as directed.
Removing excavated material any type of soil to a distance not. exc. 50 mtr and depositing where directed at a level nexc 1.5 mtr above the starting point.
M&L for Cement concrete 1:4:8 ,type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for reinforcement cement concrete M-25 (design mix) using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforcement cement concrete M-25 (design mix) using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforcement cement concrete M-25 (design mix) using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bar 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Use and waste of formwork to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter rough finished flat surface concrete complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished square, rectangular or polygonal surface concrete complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat surface concrete complete all as specified and directed.
M&L for brick work with Fly ash bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
Cutting out bricks,forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall built in 1:6 cement sand mortar
M&L for brick work with sub class 'B' bricks laid flat bedded and jointed in CM 1:6 and pointed in CM 1:3 complete all as specified and directed.
M&L for brick work with sub class 'B' laid flat on edge of drain, bedded and jointed in cement mortar CM 1:6 and pointed in CM 1:3 complete all as specified and directed.
M&L for brick work with sub class 'B' laid flat on edge of drain, bedded and jointed in cement mortar CM 1:6 and pointed in CM 1:3 but except brick complete all as specified and directed. Note:- Bricks obtained from item No 11 shall be reused after cleaning.
M&L for plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate in surface channel, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
Extra for fair finished drains or channel, n.exc 24cm inner girth in cement concrete using extra cement incl forms moulds, mitred stopped ends, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed
M&L for providing 100mm thick Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in floor, laid in panel as in sub base of floor complete all as specified and directed
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' in 100 mm thick concrete slab complete all as specified and directed.
M&L for providing 50mm thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in floor, (Laid in alternate pannel) finished the surface fair complete all as specified and as directed
M&L for 20mm thick wearproof topping as specified (incorporating an approved metallic floor hardner in ration of 1 part cement : 4 part hardener ), laid on concrete floors and pavings, and finished the surface even and smooth complete all as specified and directed. (Note:- Metalic hardner shall be measured and paid seperately as supply only under respective item)
Supply only metallic floor hardner complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'B' complete all as specified and as directed
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'B'.complete all as specified and as directed
Taking down cement or cement lime plaster of any description on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar 1:4 on faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed.
Preparing newly plastered or un plastered surfaces of wall and applying two coat of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for applying three coats of white wash on wall including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed.
S&F 1.25mm thick steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type with locking arrangment complete all as specified and as directed.
Repair of rolling shutter any type exceeding 10.0 Sqm but not exceeding 25.0 Sqm and greasing/oiling complete with locking arrangement for smooth functioning of the shutter including taking down and refixing of the rolling shutter after applying two coats of synthetic enamel paint in existing colour/shed complete all as specified and directed. NOTE: (i) The unit quoted rate inclusive of replacement of any spare parts required for smooth functioning and no any extra claim shall be entertained on this account.
Supply only Ball bearing suitable for rolling shutters complete all as specified and directed. Note : Quantity can be exceed or decrease during repair of rolling shutter
S&F in repair Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to grade Fe 290 Gde-E-165 complete all as specified and directed.
S&F expended metal or welded steel wire fabric weight exc 4 Kg per square metre fixed complete to steel member complete all as specified and directed.
M&L for preparation of old steel or iron surface of any description, exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as directed.
Hacking out old broken glass from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as directed.
S&F rough cast wired glass, 6.4mm thick area exceeding 1Sqm but not exc 1.5 Sqm and glazing with oil putty in square complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all asdirected.
Material and labour second class hardwood timber scantling as in framed trusses work clean sawn in repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store complete all as specified and directed.
Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosate paint complete all as specified and directed.
M&L for 2nd Class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats 30 mm thick as in ventlator complete all as specified and directed.
Taking down shutter of any description not exc 1 Sqm each complete all as directed.
M&L for applying two coat of synthetic enamel paint on wooden surface over a coat of pink primer of any decription over 10 cm width or girth including prepration of new wooden surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on wooden surface of any decription over 10 cm width or girth including prepration of old wooden surfaces complete all as specified and directed.
S&F 75 mm long MS Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 100 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
M&L for angle iron as in fencing post including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for brickwork using bricks obtained from item No 11 here-in-before i.e except bricks straight or curve on plan exc 6m mean radius ,built in CM 1:6 complete all as specified and directed.
Removing cement mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing off rubbish
M&L for providing pre cast RCC 1:2:4 , Type B-1 using 20mm graded crushed stone aggregates as in Cover Slab of drain and set in cement sand mortar in 1:4.complete all as specified and directed.
S& F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as directed.
Dismantling of brick tiles laid bedded and pointing in cement mortar complete all as directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as directed.
Taking down rolling shutter of any description of area not exc 20 sqm each complete all as directed.
Removing Demolished building materials from site etc to outside MD land where places earmarked by civil authorities including loading, unloading and stacking at the destination complete all as directed.
E/M Works Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and directed.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity and removing the same from site and keeping in safe custody for resuse issue on credit to contractor as directed by Engr in Charge and making good the disturbed surface/portion of walls complete all as directed.
Taking down carefully sub main wiring of any Nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories all as directed.
M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 1.6 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 3.0 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded green colour copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed.
All as per item No 80 here-in-before but 3pin ,5amp socket out let on the same board with other switch complete all as specified and directed.
All as per item No 80 here-in-before but one 3 pin, 5 Amp socket out let on independent board complete all as specified and directed.
All as per item No 80 here-in-before but one 3 pin , 15 Amps socket on independent board/ two pin earth plug socket with 2.5 Sq mm cable multi stranded copper conductor complete all as specified and directed.
S&F switch piano, single pole one way 5 Amps 240 Volt capacity flush type all as specified and directed.
S&F 3 pin 5 Amps socket outlet flush type all as specified and directed.
S&F switch piano, single pole one way 15 Amps 240 Volt capacity flush type all as specified and directed.
Supply and fixing socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
S&F ceiling rose of suitable size of bakelite 240 Volts three terminal as specified and directed.
Supply and draw sub main wiring of two run 1.5 sqmm single core FR PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of size not less than 20 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 1.5 sqmm single core FR PVC insulated unsheathed copper earth continuity conductor all as specified and directed. NOTE : (Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one unit length.) including making good disturbed surface all as specified and directed.
Supply and draw sub main wiring of two run 6.0 sqmm single core FR PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of size not less than 20 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 6 sqmm single core FR PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. NOTE : (Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one unit length.) including making good disturbed surface all as specified and directed.
S&F LED tube light fitting 1 x 20 watt, decorative , ultra slim round profile LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S & F Duranto LED highbay light 100W with fin ventilation technology for better thermal management and with cutting edge LED technology and highbay range that offers an industry leading efficacy of 150 Lm/W specially designed to deliver unmatched performance in adverse industrial envirnments with its robust housing design and cater to diverse applications with multiple options of beam angles,fixed on wall/ceiling/trusses including electric connection with twin flexible copper wire and testing complete all as specified and directed .
Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 Sqmm including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fix wall fan, AC single Phase. 230V of size 400 mm sweep with blades, complete and all as specified Make : Crompton Greaves, Usha, Bajaj,
Supply and fixing Exhaust Fan high quality mettalic body, copper winding,resistant to colour change 450 mm sweep, 1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 8 way ISI marked all as specified and directed.
Supply and fixing MCB SPN 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , con-nected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:2:4 type B-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
S & F LT UG XLPE cable PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade of size cross-sectional area 3 1/2 core x 95 sq mm , fixed on walls / ceilings / trusses of complete incl taking down the old unserviceable cables complete all as directed
Taking down LT distribution panel and cut outs etc. of any type and capacity and removing the same from site and carefully deposit to MES store as directed by Engr in Charge and making good the disturbed surface/portion of walls/surface etc , complete and all as directed
Supply,installation , commisioning & testing of LT indoor type pedestal panel , factory made, cubical, powder coated with fabricated 3.15mm thick of CRCA sheet with angle iron/ flat iron frame work, bus bar chamber, front openable hinge door with locking arrangement and common openable hinged door from the rear side, floor mounting type, protection and as per IS, and sitable size as given by manufaturing ,comprising of following:-
(a) INCOMING (i) Rectangular Aluminum strip of size 50 x 8 mm fixed on insulated mounting arrangement - 04 Nos
(ii) MCCB FP 200Amps,415 Volt with Microprocessor release 36 KA, adjustable type - 01 No
(iii) Digital Multi function meter -01 No
(b) OUTGOING (i) MCCB 160Amps FP,415 Volt, 25 KA , -2 Nos
(ii) MCCB 63 Amps TP ,415 Volt ,25 KA , - 1 No
Supply & fixing in repair sheet metal enclosure Vertical TPN DB 4 Way as per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for one No 200 Amp,4 pole MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed.
Supply and fixing in repair MCCB ,TPN, 100 Amps, 50 Hz, 25 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
M/s DHARAM VIR GHAI
imran construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .