Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹11.5 L+₹89,595 (8.44%)Rejected-Finance | L2 | Rejected-Finance Not Lowest. | |
| 3 | L3₹11.8 L+₹1.2 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest. | |
| 4 | L4₹12.1 L+₹1.5 L (13.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest. | |
| 5 | L5₹12.2 L+₹1.6 L (14.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest. |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
13 Oct 2020, 6:00 pmClosed
GE Kamptee
Garrison Engineer, Military Engineer Services, Kamptee Cantt - 441 001
REPAIRS AND CLEANING OF DRAINAGE, SEPTIC TANKS, SEWAGE LINE, MANHOLES AND CERTAIN B/R WORKS IN AREA-II AT KAMPTEE.
2020_MES_379871_1
8205/E8
Open Tender
Civil Works
Item Rate
270 days
Kamptee
Class E, Cat a (i)
7 documents required · 7 mandatory
₹500
Yes
GE Kamptee
₹20,000
Yes
29 Oct 2020
22 Sept 2020
15 Oct 2020
23 Sept 2020
13 Oct 2020
8 Oct 2020
23 Sept 2020 - 7 Oct 2020
Amount
Taking of existing cover of septic tanks/ soak well & cleaning of septic tank/ soak well of any size/ capacity by dewatering and taking out sludge in liquid mud, silt or in solid state after emptying the solid/waste water by mannual or by mechenical mean as sucking pump and trolly and removing the same to a distance not exc 50 mtr distance and put into newly excavated earth and placing back in position the removed cover complete all as specified and directed. Note:- (i) The excavation and earth work of pit in any type of soil is deemed to be included in the unit rate quoted by contractor. (ii) No extra payment shall be made for dewatering and cleaning with water which shall deemed to be included in the unit rate of this item. Net quantity of sludge removed shall be measured and paid as quoted by the contractor.
Taking of existing cover of septic tanks/ soak well & cleaning of septic tank/ soak well of any size/ capacity by mechenical sewage sucking pumping machine and transport the sludge in to a mechanical sewage carrier tank for removing the same to a distance 10 to 15km from defence land and placing back in position the removed cover complete all as specified and directed. Note:- Net quantity of sludge removed shall be measured and paid as quoted by the contractor.
Cleaning of blocked sewer/ sewage line of any discription (SGSW/ RCC/ CI pipe) of 100mm/ 150mm/ 200mm dia or any dia at any depth by rodding or by mechanical means and well flushing the complete sewer line with water from manhole to manhole to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed.
Taking off existing manhole cover & cleaning of manhole (any size/ depth) by dewatering and taking out rubbish/ sludge etc by mannual or by mechanical means and removing the same to a distance not exc 50mtr distance and put into newly excavated earth and placing back in position the removed cover complete all as specified and directed.
Cleaning of blocked / chocked WC (any pattern) including sewer/ sewage line of any discription (SGSW/ RCC/ CI pipe) of 100mm/ 150mm/ 200mm dia or any dia at any depth by rodding or by mechanical means and well flushing the complete sewer line with water upto first manhole to the entire satisfaction of Engineer-in-Charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed.
Cleaning of blocked / chocked Nahani Trap/ floor trap including drain/ sewer/ sewage line of any discription (SGSW/ RCC/ CI pipe) of 100mm/ 150mm/ 200mm dia or any dia at any depth by rodding or by mechanical means and well flushing the complete sewer line with water upto first manhole to the entire satisfaction of Engineer-in-charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed.
Excavation over areas not exc 1.5 m deep and getting out in hard / dense soil complete all as specified and directed.
All as per item No. 7 above but depth exc 1.5m and not exc 3.0m deep complete all as specified and directed.
All as per item No. 7 above but depth exc 3.0m and not exc 4.5m deep complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L for loose filling with broken bricks of guage 80 to 150mm in soakage pits / soakage wells complete all as specified and directed.
Demolition of cement concrete bed in hauching and breaking up drain pipes SGSW, set in cement mortar of 100mm dia complete all as specified and directed.
All as per item No 14 above but 150mm dia complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in bed to drain pipe 150mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed.
All as per item 16 above but for 100mm bore complete all as specified and directed.
M&L for 100mm bore SGSW drain pipe grade 'A', laid in trenches and jointed in CM 1:1 complete all as specified and directed.
All as per item No 18 above but 150mm bore complete all as specified and directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for cement concrete1:2:4 type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands coping/ cills including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs, for manholes etc and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed.
M&L for mild steel TMT bars 8mm dia and over cut to length, bent to shapes as required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' old size burnt bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' old size burnt bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with sub class ‘B’ common burnt clay bricks, old size, in one brick thick honey comb walling, built in cement mortar (1:4) complete all as specified and directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not exc 200mm thick and flat fair finished surfaces complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs and in shelves and the likes complete all as specified and directed.
M&L for framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described, exc 10cm width or girth & applying with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down cement or cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick work or concrete sufaces including finished even and fair complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms etc complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in surface channel and drain finished even and smooth using extra cement complete all specified and directed.
Dismantling of cast iron pipe of 100mm dia jointed in cement mortar and taking out in trenches, if required complete all as specified and directed.
S&F to wall cast iron soil, waste and vent pipes, 100mm in any length with or without ears, with cement joints complete all as specified and directed.
All as per item No 40 above but 75mm bore complete all as specified and directed.
S&F CI bends (any radius) disminishing pieces or tapers (larger bore mearsured) for 100mm dia complete all as specified and directed.
All as per item No 42 above but 75mm bore complete all as specified and directed.
S&F CI 100mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed.
All as per item No 44 above but for 75mm bore complete all as specified and directed.
Dismantling PVC pipes (110/75mm) jointed in cement mortar and taking out of trenches/ from walls including fittings as bends, branch pieces, traps etc complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends, any radius complete all as specified and directed.
All as per item No 47 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110m bore junction double, (Double T) equal or unequal complete all as specified and directed.
All as per item No 49 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed.
All as per item No 51 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius with access doors complete all as specified and directed.
All as per item No 53 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
All as per item No 55 above but 75mm bore complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding and taking out rubbish off the premises complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 6 to 7mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exc 0.11 sqm, in floors etc, set and jointed in neat cement slurry over 15mm screed bed in CM 1:6 and pointed in white or colored cement to match complete all as specified and directed.
M&L for coloured glazed ceramic tiles 300x450x6 to 7mm thick, in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles including rendering 10mm thick in CM 1:4 complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed to wall with clamps including taking up or down existing GI tubing complete all as specified and directed.
S&F in repairs vitreous china white squatting pan "Orissa Pattern" of size 580 x 440mm, with integrated foot rest (excluding flushing sistern, flush pipe etc) including making good to floor complete all as specified and directed.
S&F in repair white vitreous china wash down water closet pan (pedestal pattern) including plastic water closet seat, white/ black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe and fixing bolts (excluding flushing cistern) etc complete all as specified and directed.
S&F in repair 10 litre capacity PVC valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.23,775.00]
M/s Rahul Traders
MVN Enterprises
M/s DS Khekde
M/s M.G. Hargunani
M/s T.S.JOHAR
Bidder Name
MVN Enterprises
SHUB CONSTRUTION
M/s T.S.JOHAR
M/s Rahul Traders
M/s DS Khekde
M/s M.G. Hargunani
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .