Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹25.2 L+₹21,130.40 (0.85%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹25.3 L+₹35,216.60 (1.41%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹25.5 L+₹57,382.80 (2.30%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹25.6 L+₹65,663.25 (2.63%)Rejected-Finance DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DARJEELING WEST BENGAL 734201 | DARJEELING | WEST BENGAL | 734201 | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹23.6 L
EMD Value
₹48,000
Closing Date
6 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
ADDN / ALTN AND UPGRADATION OF BLDG NO P-99 AT LEBONG UNDER AGE(I) DARJEELING
2023_MES_613760_1
CWE/136-WE/10 OF 2023-24
Open Tender
Civil Works
Item Rate
240 days
Darjeeling
Class E, Category a(I)
8 documents required · 8 mandatory
₹500
AGE (I) Darjeeling
₹48,000
8 Jan 2024
14 Aug 2023
7 Sept 2023
14 Aug 2023
6 Sept 2023
29 Aug 2023
14 Aug 2023 - 21 Aug 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Add to item 11007 if fixed with L-type or J-type or cranked hook bolts in lieu of screw, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F of mild steel hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts conforming to Fe-290 Gde E-165, complete all as specified and directed.
S&F of framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), complete all as specified and as directed.
S&F of anodised aluminium snap grid frame work of size of grid 605 x 605mm, for false ceiling, complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / aluminium framework with screws in ceiling flat or sloping, complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes even and rough, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles, complete all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles, complete all as specified and directed.
M&L for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments, complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces, complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of tiles, complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) with water proofing compound @ 3% by weight of cement or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M&L for 5 mm thick rendering in cement mortar (1:3) on concrete surfaces in ceilings and finished even and smooth (without using extra lime or cement), complete all as specified and directed.
Supply only integral water proofing compond, all as specified and as directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering) including 3mm thick wall care putty on wall, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of cement paint over a coat of alkali resistant priming paint, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of ceiling and applying two coats of oil bound distemper (distemper oil-emulsion) over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) including 3mm thick wall care putty on ceiling, complete all as specified and directed.
M&L for complete removal of existing treatment on plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying one coat 3mm thick of wall care putty and then applying two coats of distemper oil emulsion(OBD), white or tinted over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) after preparation of wall surfaces, complete all as specified and directed.
M&L for complete removal of existing treatment on plastered or unplastered surface of ceiling including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying one coat of oil bound distemper (distemper oil-emulsion) over a coat of priming coat (Chalk whiting, on plastered surfaces, preparatory to distempering) including 3 mm thick layer of wall care putty on ceiling after preparation of wall surfaces, complete all as specified and directed.
M&L for complete removal of existing treatment on plastered or unplastered surface of wall including brooming down or steel wire brushing, scrapping down smoke scoot, mould, moss and efflorescent salt, trading oil and greasy spot and applying two coats of cement paint over a coat of alkali resistant priming paint after preparation of wall surfaces, complete all as specified and directed.
Taking up or down old 15 mm bore steel water tubing and connections, including cleaning for refixing or removal to store or from site, complete all as specified and directed.
Taking up or down old 20 mm bore steel water tubing and connections, including cleaning for refixing or removal to store or from site, complete all as specified and directed.
Taking up or down old 25 mm bore steel water tubing and connections, including cleaning for refixing or removal to store or from site, complete all as specified and directed.
S&F of 15 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed.
S&F of 20 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed.
Refixing old 15 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Refixing old 20 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Refixing old 25 mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.), complete all as specified and directed.
Supplied and fixed in repairs of 15 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
Supplied and fixed in repairs of 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F in repairs of 20 mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 mm - 210 gms. / 25mm-455gms/ 40mm - 690 gms), complete all as specified and directed.
S&F in repair 15mm bore dia bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F in repair 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F of vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including mild steel chromium plated health faucet suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook and plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
S&F of 100mm bore of pipe ‘P’ or ‘S’ traps without vent horn, complete all as specified and directed.
S&F of PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type, complete all as specified and directed.
S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed.
S&F of towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms), complete all as specified and directed.
S&F of 1mm thick stainless steel sink with drainage board kitchen or laboratory type with waste pipe, plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size of sink 915mm x 460mm and bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
Dismantling water tanks of capacity exc 500 and n exc 1000 litres and removing to store, complete all as specified and directed.
S&F of rotational moulded polyethylene water storage tanks of capacity 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-l and directed.
S&F of grating doom 100mm dia of PTMT (Minimum weight 25gms), complete all as specified and directed.
Taking down chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down shutters of any description n exc 1 sq. m each, complete all as specified and directed.
Taking down shutters of any description exc 1 sq. m and n exc 2 sq. m each, complete all as specified and directed.
Dismantling unframed timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and directed.
M&L for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with one coat of creosote oil, complete all as specified and directed.
M&L for second class hard wood, 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
S&F of 35 mm thick (batten thickness) second class hard wood, glazed and skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
M&L for second class hard wood, 30mm thick glazed and skeleton windows shutters, ventilators shutters etc. are provided with stiles and rails, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24(b); supplied and fitted to chowkats, complete all as specified and directed.
S&F of solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing and as directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed.
S&F of 100 mm size butt hinges, medium weight, cold rolled mild steel and fixed, all as specified and directed.
S&F of 75 mm size butt hinges, medium weight, cold rolled mild steel and fixed, all as specified and directed.
S&F of 150 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of 100 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 125mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, all as specified and directed.
S&F of 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, all as specified and directed.
Hacking out old broken glass, exc 1.5 sqm (any thickness, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
S&F of 3.0mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F of 3.0mm thick sheet glass ground or obscured or frosted, on one side, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S&F of small fittings such as brackets of any type latch and hinge block, shaped door window stops and the like in second class hard wood article not exc 200 cu. cm each, complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for brickwork with fly ash bricks(old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6), complete all as specified and directed.
M&L for preparation of new wooden or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
S&F of bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for hardcore using broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete(1:3:6), type C-2 (40 mm graded stone aggregate) as in plinth protection, hard standing, path etc including finish the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for plain cement concrete(1:3:6), type C-2 (40 mm graded stone aggregate) in surface channels and drains, complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitered / stopped ends etc all as specified and as directed.
M&L for 40mm thick plain cement concrete(1:2:4), type B-1, (using 20mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc, all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed.
S&F of 180mm bore PVC (SWR) gutter drain pipe, complete all as specified and directed.
S&F of 180mm bore PVC (SWR) joint socket, complete all as specified and directed.
S&F of 180mm bore PVC (SWR) joint tee, complete all as specified and directed.
S&F of 180mm bore PVC (SWR) joint tee with end cap, complete all as specified and directed.
S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed.
M&L for plain cement concrete (1:2:4), type B-1 (using 20 mm graded stone aggregates) in coping, bed plates, parepet, plinth course including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not specifically provided for, complete all as specified and as directed.
M&L for providing precast cement concrete (1:2:4), type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces with plain fair faces, including chamfers, weatherings, throat- ing etc. and set in cement mortar (1:4), complete with joints to match complete all as specified and directed.
S&F of TMT bars 10 mm dia and over, cut to length, bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F in repairs of 20mm dia harrison rails (curtain rails), anodised aluminium alloy with fixing brackets, stops, rollers etc., all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Taking down carefully sub main wiring of any size/core/type including conduit/ cashing/ batten of any type and making good disturbed surfaces to match with the existing surface roof/ wall/ floor, complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for light / Fan / Bell on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for light / Fan on independent board, point controlled by two way switchs including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Three run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 pin socket outlet 5 amps on the same board with other switches including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 pin socket outlet, 5 amps on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for point wiring with 2.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 25mm dia (concealed), medium grade with all necessary fittings, concealed wiring for one 3 / 5 pin socket outlet, 5 / 15 amps on independent board, point controlled by one switch including 2.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes:- (i) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 2.5 Sq.mm for phase and neutral and one run of 2.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed)
M&L for modular switch one way 6 Amps, 1 module, 240 Volts, all as specified and directed.
M&L for modular switch two way 6 Amps, 1 module, 240 Volts, all as specified and directed.
M&L for modular bell push 6 Amps 1 module, 240 Volts, all as specified and directed.
M&L for modular socket, 6 Amps - 2/3 pin combined 2 module, 240 Volts, all as specified and directed.
M&L for modular socket, 6Amps / 16Amps - 2/3 pin combined 2 module, 240 Volts, all as specified and directed.
M&L for modular switch one way 16 Amps, 1 module, 240 Volts, all as specified and directed.
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
M&L for modular blank plate, 1 module, 240 Volts, all as specified and directed.
M&L for modular white cover plate with frame, 2 module, 240 Volts, all as specified and directed.
M&L for modular white cover plate with frame, 3 module, 240 Volts, all as specified and directed.
M&L for modular white cover plate with frame, 4 module, 240 Volts, all as specified and directed.
M&L for modular white cover plate with frame, 6 module, 240 Volts, all as specified and directed.
M&L for modular metal flush box, 1/2 module, 240 Volts, all as specified and directed.
M&L for modular metal flush box, 3 module, 240 Volts, all as specified and directed.
M&L for modular metal flush box, 4 module, 240 Volts, all as specified and directed.
M&L for modular metal flush box, 6 module, 240 Volts, all as specified and directed.
M&L for Buzzer, Ding Dong AC. 230 volts, single pole, all as specified and directed.
Supply and fixing in repair / replacement of LED lights fitting 4feet, 1x 22W, 230V, AC decorative ultra slim extruded aluminium batten fixure with high lumen output, environmental friendly, energy efficient including LED tube light and bipin holder, connector block, driver etc. with all accessories internally pre-wired connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, all as specified and directed.
Supply and fixing in repair / replacement of LED lights fitting 2feet, 1x 8W, 230V, AC compact commercial batten type with high lumen output, environmental friendly, energy efficient including LED tube light and bipin holder, connector block, driver etc. with all accessories internally pre-wired connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, all as specified and directed.
Supply and fixing in repair / replacement of building security light fittings new generation energy saving and enviornmental friendly long life versatile pressure die-cast aluminium IP66 protection with acrylic cover of LED 35 Watts luminaire including GI bracket of suitable size with clamp, complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, all as specified and directed.
S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC conduit of required size with accessories for sub main connection including 4.0 Sqmm FRLSH insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 4.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
Supply and fixing in repair / replacement of MCCB 100 Amps with breaking capacity 16 KA including sheet metal enclosures, all as specified and directed.
Supply and fixing in repair / replacement of triple pole and neutral (TPN) DB with sheet metal enclosure, 4 way, single door, 415 volt with rated bus bar suitable for mounting incoming and outgoing MCBs double pole / single pole including fixing on suitable rectangular block, complete all as specified and directed.
Supply and fixing in repair / replacement of single pole and neutral (SPN) DB with sheet metal enclosure, 8 way, double door, 240 volt with rated bus bar suitable for mounting incoming and outgoing MCBs double pole / single pole including fixing on suitable rectangular block, complete all as specified and directed.
Supply and fixing in repair / replacement of miniature circuit breaker (MCB) of single poles (SP), current carrying capacity 6 to 32 Amps with breaking capacity 10KA 'C' curve, 240/410 volt duly fixed with lugs / sockets / thimbles, complete all as specified and directed.
Supply and fixing in repair / replacement of miniature circuit breaker (MCB) of single poles and neutral (SPN), current carrying capacity 40 Amps with breaking capacity 10KA 'C' curve, 240 volt duly fixed with lugs / sockets / thimbles, complete all as specified and directed.
Supply and fixing in repair / replacement of miniature circuit breaker (MCB) of four poles (4P), current carrying capacity 63 Amps with breaking capacity 10KA 'C' curve, 415 volt duly fixed with lugs / sockets / thimbles, complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC chamber with PCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge
Supply and fix, installation and testing metalic (steel) body electric water heater(Geyser), vertical type with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including PCC work with drilling holes if studs provided, complete all as specified and directed.
S&F of 15 mm bore tubes 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
S&F of 15mm bore dia stop valves, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
S&F of 15mm bore dia bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
Cutting existing steel tubing for alterations or additions (Each cut measured) and screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector), necessarily done in position without taking down, complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
RAI CONSTRUCTION
Darjeeling Enterprises
M/S TSHERING BHUTIA
REEMA TAMANG AND SONS
Damdoo Bhutia
HIRA SINGH
BIMAL BHATTRAI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .