Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.1 LAccepted-AOC | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹7.3 L+₹7,580 (1.05%)Rejected-Finance 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹7.8 L+₹55,106 (7.61%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | 4₹8.5 L+₹1.2 L (16.7%)Rejected-Finance | 4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO NON FULFILLMENT OF NIT CONDITION |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
3 Jul 2023, 6:00 pmClosed
AGE(I) Fatehgarh
AGE(I) Fatehgarh Cantt
REPAIR/ REPLACEMENT OF INTERNAL WIRING FITTING AND FIXTURES IN MARRIED ACCN OF RRC, MH AND MES AT FATEHGARH CANTT
2023_MES_600405_1
AGE(I)/FAT/ET-04 OF 2023-2024
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE(I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE(I) Fatehgarh
₹18,000
Yes
4 Aug 2023
5 Jun 2023
10 Jul 2023
5 Jun 2023
3 Jul 2023
19 Jun 2023
5 Jun 2023 - 18 Jun 2023
Amount
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and as directed .
Taking down Aluminium sub main wiring of any description and in any position including GI earth wire and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed by the Engr-in-Charge.
M&L for point wiring of for the One light/ holder/fan/exhaust fan/ bell point with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) not less than 20 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc controlled by one switch switch 5/6 Amps complete all as specified & directed. Note:- (i) The quoted rate is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good with using CM 1:4 and surface finished to match the existing surface & Colour.
…ditto as above but for one 5 pin 5 Amp switch socket combination point on an independent board ..ditto as above...
…ditto as above but for one 5 pin 5 Amp socket point controlled by one switch on same board ..ditto as above…
…ditto as above but for one 16 Amp 6 Pin switch socket combination independent with 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded ..ditto as above…
S&F Switch Piano Flush type 6 Amp single pole one way complete all as specified and as directed.
S&F Switch Socket Combination 2 in 1 flush type 6 Amp 5 Pin complete all as specified and as directed.
S&F Switch Socket Combination 5 in 1, 16 Amp flush type complete all as specified and as directed.
M&L for Lamp Holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings including LED Lamp of 9 Watt and colour temp 6500K suitable for fix in angle holder complete all as specified and directed.
S&F Bell Push AC 230 volts complete all as specified and as directed.
S&F Call Bell Ding Dong AC 230 volts complete all as specified and as directed.
S&F Electronic Fan Regulator 5 stepped type complete all as specified and directed
S&F Ceiling Rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with using two single core 6 Sqmm (FRLS ) copper conductor PVC unsheathed cable with and including PVC conduit (appropriate size) ISI Marked medium grade not less than 19mm dia concealed in wall for sub main wiring & connections including 4.0 Sqmm (FRLS) insulated multistranded unsheathed copper conductor cable used as a earth wire to common earth and connection to earth dolly all as specified. Note :- (i) Two runs of 6 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor cable & PVC conduit shall be measured as one unit length. (ii) Cutting chases for concealed wiring shall be made good by the contractor at his own cost with using Cement Mortar ( 1:4) / PCC ( 1:2:4) type B-0 (using 12.5mm graded stone aggregate) and surface finished to match the existing surface.
Supply and fixing in replacement of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified and as directed.
Supply and fixing in repair MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and as directed.
Supply and fixing in repair MCB distribution board SPN 240 Volt 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and as directed.
S&F in repair of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed.
S&F in repair of MCB SPN 40 to 63 Amp Amp 240 volt 'C' 10 KA curve complete all as specifed and directed.
S&F in repair of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F LED Batten 4 Ft surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of > 120 lumens / W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.9, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.75 Sqmm and fixing arrangement for fixing the light fitting including marking CA No on LED fitting with permanent marker style and size decided by eng-in-charge complete all as specified and directed.
S&F LED batten 2 Ft surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 10W luminaire lumen >1000 lm, system efficiency of > 100 lumens / W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 45 ºC, driver efficency >85%, power factor >0.9, THD <20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification and connecting the same in electric source with and using PVC sheathed and insulated 3 core copper conductor cable of size 0.75 Sqmm and fixing arrangement for fixing the light fitting including marking CA No on LED fitting with permanent marker as style and size decided by eng-in-charge complete all as specified and directed.
S&F LED security light fitting 1x15 watt new generation energy saving & environmental friendly long life LED street light made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistence of IK07 for building security purpose complete all as specified & directed by Engineer-in- charge.
S&F in repair to metal plug & socket DB with metal plug and MCBs dobule pole and neutral enclosere with a two pin earth plug and socket suitable for 20 Amp complete with one single pole MCB complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown iln electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but with earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) including dismantling of exsisting earthing complete all as specified and as directed. Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.
M/S CHAUHAN ELECTRIC WORKS
MS. BK BROTHERS AND CO
M/S SRI JAGDAMBE TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .