Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.0 LAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹98.8 L+₹7.2 L (7.91%)Rejected-Finance OFFICE NO 2 GROUND FLOOR CO OP HSG SOCIETY SBS ROAD COLABA MARKET MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than being Lowest | |
| 3 | L3₹1.3 Cr+₹34.3 L (37.5%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L3 | Rejected-Finance Other than being Lowest | |
| 4 | L4₹1.4 Cr+₹44.6 L (48.7%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance Other than being Lowest | |
| 5 | L5₹1.5 Cr+₹54.3 L (59.3%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Other than being Lowest |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
14 Feb 2023, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR TO LEAKAGE SEEPAGE PLASTERING JOINERIES WALL FLOOR TILES AND OTHER MISC WORKS AT OLD RS AND RASHI COMPLEX UNDER AGE B R II OF GE NW NAVY NAGAR COLABA MUMBAI
2023_MES_574033_1
8129/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar
Class B
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹2.2 L
Yes
12 Apr 2023
9 Jan 2023
16 Feb 2023
9 Jan 2023
14 Feb 2023
30 Jan 2023
9 Jan 2023 - 27 Jan 2023
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including chaina mozaic, WC etc complete all as specified and directed by Engr-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Treatment of sunken floor slab compraises of the following specifications and complete all as specified and directed by Engr-in-Charge. :-
(i) Material and labour for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate mixed with integral water proofing compound @ 3% by wt of cement consumed.as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately)
(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.( WPC shall be measured & paid separately)
(iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty.
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(v) Material and labour for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately)
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (GI pipes shall be paid separetely).
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Cutting holes in bricks or RCC walls exc half brick built in cement mortar including making good after inserting and setting spouts complete all as specified and directed by Engineer-in-Charge.
GI pipe 50mm dia medium grade laid on sunken floor complete all as specified and directed by Engineer-in-Charge.
Material and labour for filling with PCC 1:5:10 type E2 (1 Cement : 5 coarse sand : 10 graded aggregate 40 mm nominal size) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Dismantling floor, hearth, or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour non-skid coloured Ceramic tiles 6 to 7mm thick (square/rectangular) area of each tile exceeding 0.06sqm but not excceding 0.11 sqm, in floors etc, set and jointed in epoxy mortar and pointed in white of coloured cement to match including 20 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour Coloured glazed ceramic tiles 300 x 200 x 7mm on vertical surfaces set & jointed in neat cement slurry and pointed in white cement mixed with pigment complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for rendering 10mm thick in cement mortar 1:4 on backing coat of wall tiles etc complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour non-skid coloured Ceramic tiles 6 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not excceding 0.18 sqm, in floors etc, set and jointed in epoxy mortar and pointed in white of coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 sqm each complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per Item No 11 above but exc 1.5 sqm but n exc 4 sqm each complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour machine cut Kota stone ( greenish colour, pre mirror polished) slab in one piece as in double steps cill of aluminium slding window 18 to 20 mm thick over 20 mm thick screed bed in cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour machine cut Kota stone ( greenish colour, pre mirror polished) slab in one piece as in lintel and sides of aluminium sliding window 18 to 20 mm thick over 15 mm thick rendering in CM 1:3 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing powder coated anodised aluminium frame/track or shutters for windows, ventilators etc. with one or more rebates including joining cleat for fixing etc.fixed or sliding type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws locking arrangements etc. complete all as specified and directed by Engineer-in-Charge. Note: Minimum 25 micron anodisation for all aluminium sections)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour powder coated aluminium grill with suitable aluminium anodised frame section of ‘F’ section of size 23.4 x 15.3 x 1.4 mm thick manufactured by M/S Deco grill pattern DG-102 (80 X 66mm) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 4mm thick plain sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 4mm thick frosted sheet glass ordinary quality and glazing with aluminium and neoprene beads in square n. exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing Aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm, cut to required size and fixed to Aluminium doors,windows shutter aluminium wire staples complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repairs aluminium serrated finish 20mm dia curtain rod of approved pattern and shade with all fittings as per site requirement such as end block, rounded block, brackets, CP screws, rovel plug, etc. complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 2omm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of fplain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles. & rails with suitable PVC sheet beading, and joined together with sovent cement, suppling & fixing in the frame at site as per complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixing in opening complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down shutters of any description exc 1.5 sqm and n exc 4 sqm each complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing factory made shutter 35 mm thick second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc edges of framing, plain chamfered or rounded fitted with cut and mitred beads fo securing gauge etc suzes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 35 mm thick factory made Flush shutters , solid core constrution with block board core and plywood face panels, commercial type on both side complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 100 mm extruded aluminium handles, fabricated type anodised complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 100mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 75mm stainless steel medium weight butt hinges complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 150 mm extruded aluminium handles, fabricated type anodised complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 300 mm long aluminium alloy , anodised sliding door bolt with hasp and staple ( bolt type ) and fixing bolt and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 140 mm overall length floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 100mm size stainless steel medium weight butt hinges complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for two coat synthetic enamel paint over a coat of pink primer on new wooden surface of any description over 10 cm width or girth not otherwise described including prepration of surface complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repairs Aluminium wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm, cut to required size and fixed to doors,windows shutter (wooden/aluminium), with wooden beading (any size)or aluminium wire staples and removing old beading, complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repairs for vitreous china squatting pan Orissa pattern of size 580 x 440 mm white with back inlet and integral footrest and anti syphonnage pipe including 'P' or 'S' trap and provn of lime concrete complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repair Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repair 32mm dia waste coupling of PTMT (half or full threaded) minimum weight 32mm- 45gns complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing Unplasticised PVC pipes of pressure rating 10 kgf/cm2 of 50 mm bore fixed complete to walls, ceiling or in floors including bend and sockets etc; any type of pipe complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repair PVC valveless, syphonic action type, flushing cristern, 10 ltr capacity low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing Flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for CI Nahani trap dia of outlet 75mm fixed in repairs including jointing to waste pipe in runlead fixed in cement concrete type B 1 (1:2:4). complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing PTMT grating doom over Nahani trap and floor trap of 100mm Dia (Minimum weight 25 gms) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down CI soil/waste/vent/rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing CI soil/waste/vent pipe in any length with ears 100mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per item 47 above but except pipe complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing CI soil/waste/vent pipe in any length with ears 75mm bore (sand cast) in any length with cement joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per item 49 above but except pipe complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing CI bends (any radius) for soil/waste pipes 100mm bore diminishing pieces or tapers on walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing CI bends (any radius) for soil/waste pipes 75mm bore diminishing pieces or tapers on walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing CI branch piececs single (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 100mm bore pipe (Y or T) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing CI branch piececs single (equal or unequal) ordinary or inverted (spigot or socked type) with parallel branches for 75mm bore pipe (Y or T) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down PVC rain water pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing PVC (SWR) bends 160mm bore any radius complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing PVC (SWR) bends 110mm bore any radius complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking up or down GI tubing and connections 15 mm bore including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Refixing old GI tubing and connection15 mm bore in new or old position in ( Walls, ceiling, floors etc) with old accesories complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing GI Tubing 15 mm bore medium grade with all fitting and fixed comlete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repairs bib taps15 mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repairs stop valves 15 mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Complete removal of existing treatment from wall & ceiling surfaces by scrapping, washing & applying two coat of Acrylic emulsion paint exterior grade (100% Acrylic) over one coat of primer inluding necessary scaffolding, Safety net etc all complete as direted by Engr-in-Charge. Note :- 1. Work to be carried out upto G+14th floor. 2. Second coat to be applied after inspection of 1st coat complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any discription including racking out joints hacking for key scrubbing down with water in patches n.exc. 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for rendering 15mm thick in CM 1:6 on other than fair faces of bricks work or concrete finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for 05 mm thick plastering in CM 1:3 on concrete surface on ceiling finished even and smooth complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for 20 mm thick plastering in two coats 15 mm thick backing coat in CM 1:6 and 5 mm thick setting coat in CM 1:4 mixed with water proofing compound @ 2% by weight of cement on fair faces of brick work or concrete wall surfaces finished even and smooth without using extra cement and using welded mesh where required all as specified including scaffolding, Safety net etc complete all as specified and directed by Engineer-in-Charge. (Note :- WPC and welded mesh shall be measured and paid separately)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply only integral water proofing compound of approved ISI complete all as specified and directed by Engineer-in-Charge.
Supply only Welded steel wire fabric not exc 4 kg per sqm for plastering in concrete surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour preparing newly plastered surfaces of walls and applying two coats of Acrylic based exterior paint exterior grade (100% Acrylic) over a coat of primer & bio wash on wall complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per item 74 above but on ceiling complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repairs Sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wasters, including bedding in cement mortar to dwarf walll or including fixing cantilever brackets and connecting union to pipe over all size 915mm x 460 mm bowl sie 410mm x 330 mm x 160mm complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repair 1mm thick plate rack made of stainless steel, 600 x 750X250mm(Wt not less than 7.5 Kg) including brackets and embedded in brick wall all as specified and as per manufacturers instruction complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repair 15mm bore dia brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing in repair health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union fixed in repair complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply and fixing Chromium plated shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of chromium plated including fixing to steel pipe or union fixed in repair complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Demolition of existing treatment of any type and preparing the surface by cleaning the concrete surface with wire brush and high pressure water jet and ensure that it is free of dust, oil, grease, loose particles vegetation roots etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with liquid water proofing compound and 1:30 slope to be maintained complete all as specified and directed by Engr-In-Charge.
Supply only integral water proofing compound.(ISI Marked) complete all as specified and directed by Engr-In-Charge.
Material and labour for 10mm thick rendering in CM 1:4 with mixed with liquid water proofing compound on fair faces of brick work or on concrete surfaces complete all as specified and directed Engr-In-Charge.
Material and labour for preparation of newly plastered/RCC surface making surface completely dry and applying primer conforming to IS 3384-1965 @ 0.30 Kg/Sqm to be applied on prepared surface till the surface is properly impreganted.water proofing treatment shall be provided with APP modified water proofing membrane 4 mm thick ( weighting not less than 3.00 Kg/Sqm on prepared suface after the primer has dried the membrane will be laid by torching to the surface as per manufacturer instruction and under strict supervisition .APP polymeric water proofing membrane shall consist of center core of 160 GSM Non Woven polyester mat protected on both side with a high quality polymeric asphaltic mix will be protected both side with thermo fusible HMHDPE film having the technical specification, laying procedure , overlap fusing methology and treatment around rain water pipe spout and tank stagging and similar location as per zonal specfication .After laying membrane apply a layer of blown biumen (conforming to IS 702) 85/25 grade @1.2 Kg/Sqm with blinding material such as sand in dry condition @ .5 to 1.00 Kg/Sqm shall be dusted over the bitumen complete all as specified and directed by Engr-In-Charge.
Material and labour for Cement concrete 1:2:4 type B-1 ( 20 mm graded crushed stone aggregate) as coping ,roof padding, in roof kerb or mud stops ,water through and like including weathering,silghtly rounded or chamfered angle and throating with necessary formwork complete all as specified and directed by Engr-In-Charge..
Material and labour for plain cement concrete tiles 30cm x 30cm x 22 to 25 mm thick with grey cement and no pigment machine pressed, set jointed and pointed in neat cement slurry in roofs , including 15 mm thick screed bed or bedding layer for laying tiles in C:M 1:4 complete all as specified and directed
Dismantiling of Asbestos cement/Galvalume/GI (Corrugated, semicorrugated, etc.)sheets in roof covering complete all as specified and directed by Engr-In-Charge.
Supply and fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed by Engr-In-Charge.
Dismantling mild steel work as in angles, tubular ,brackets of vally gutter of any description and in any position complete all as specified and directed by Engr-In-Charge.
Material and labour and fabrication of mild steel work Fe-290 (Gde E-165 as in posts, purlins, rane gantires, rafter ,rails,wind tie nut & bolt etc and fasteningsetc and heavy brackets framing (MS tube, beam,tee,angle,channels,flat section etc and other sections) including distance pieces,cleats etc complete all as specified and directed by Engr-In-Charge.
Supply and fixing including fabrication framed work in MS Flat iron such as grills, gratings, etc with end of bars shouldered and/ or riveted or bolted with nuts and bolts framework conforming to Fe 290 Gde E-165 complete all as specified and directed by Engr-In-Charge.
Material and labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-In-Charge.
Material and labour for preparation of old steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-In-Charge.
Material and labour non-skid coloured Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not excceding 0.38 sqm, in floors etc, set and jointed in epoxy mortar and pointed in white of coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-In-Charge.
Hacking out old broken glass (any thickness, quality or description) from wooden frame or stone concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engr-In-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar complete all as specified and directed by Engr-In-Charge.
Material and labour 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in subbase to floors complete all as specified and directed by Engr-In-Charge.
Material and labour machine cut kota stone slab flooring 20 to 25 mm thick over 15mm thick cement screed bed in CM 1:6 laid & jointed with grey cement slurry & pointed with pigment to match the shade of the slab including rubbing & polishing (Mirror finish) complete all as specified and directed by Engr-In-Charge.
Material and labour for applying two coats of water proofing coating system by applying shalicry - 215 of STP ltd/Rain coat 601 of Dr Fixit/Barrier coat of Araldite Ltd. over a coat of respective primer including prepariation of plaster surfaces or complete removal of existing treatment filling up of all cracks with approved crack fillers complete all as specified and directed by Engr-In-Charge.
Removing demolished material outside MoD land complete all as specified and directed by Engr-In-Charge. (Note:- For item No 85 to 104 Work to be carried out at G+14 bldg including top roof, parapet and shaft walls with scaffolding & safety measures in repairs and in patches).
M/s. MAYUR ENTERPRISES
BOB ENTERPRISES
ASHOK CONSTRUCTION
S S ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .