Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance | L1 | Accepted-Finance lowest tenderer L1 | |
| 2 | L2₹4.0 L+₹7,423.38 (1.88%)Accepted-Finance | L2 | Accepted-Finance Lowest tenderer L2 |
| Sl No | Description | Qty | Unit | Naturals Cool L1 | NATURAL AIRCON SOLUTION L2 |
|---|---|---|---|---|---|
| 1.00 | Renewal by Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with Rotory compressor operating on Non CFC Refrigerant suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 3 star rating of as per BEE specification and capable of performing the functions of Cooling Dehumidifying Air Circulating Filtering
The installation works for the above split type AC units includes the following.
1.Mounting / Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of 6 meters length, both units after drilling hole/holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm.
3. Insulating the suction pipe with expanded polyurethelene foam 5mm thick tubing.
4. Laying 25mm dia flexible PVC drain pipe of 6 mts. Length to drain out the condensate water being formed in the indoor unit.
5. Leak testing the entire gas unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 3 core 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 4 Meters length and up to switch within 3 Meters of location of indoor unit. (Carrier/Voltas/Daikin/Equivalent) | 6 | Nos | 45,500 ₹2,73,000 Lowest | 46,140 ₹2,76,840 |
| 2.00 | Renewal by Supply and fixing of MS Stand wall clamp support for mounting outdoor unit of split type Ac unit complete. | 6 | Nos | 960 ₹5,760 Lowest | 980 ₹5,880 |
| 3.00 | Renewal by Supply and fixing of 5/8" and 3/8" Copper Pipes with insulation foam of 6 mm thickness suitable for split type AC unit. | 53 | Mtr | 963 ₹51,039 Lowest | 1,000 ₹53,000 |
| 4.00 | Renewal by Supply and fixing water drain pipe line (1" PVC pipe) | 74 | Mtr | 55 ₹4,070 Lowest | 60 ₹4,440 |
| 5.00 | Add GST @ 18% | 1 | Nos | 60,096.42 ₹60,096.42 Lowest | 61,228.8 ₹61,228.8 |
Tender Value
₹4.0 L
EMD Value
₹3,960
Closing Date
6 Oct 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,Electrical
Office of the Executive Engineer, Electrical,PWD., Electrical Division, Thanjavur-1
Renewal of Worn out AC units in Dean Chamber ECRP ICU in Government Ranees Hospital at Pudukottai in Pudukottai District.
2026_PWD_706575_1
2-3/2026-27
Open Tender
Electrical Works
Lump-sum
45 days
Pudukottai
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹3,960
12 Oct 2026
21 Sept 2026
7 Oct 2026
21 Sept 2026
6 Oct 2026
21 Sept 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with Rotory compressor operating on Non CFC Refrigerant suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with 3 star rating of as per BEE specification and capable of performing the functions of Cooling Dehumidifying Air Circulating Filtering
The installation works for the above split type AC units includes the following.
1.Mounting / Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of 6 meters length, both units after drilling hole/holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm.
3. Insulating the suction pipe with expanded polyurethelene foam 5mm thick tubing.
4. Laying 25mm dia flexible PVC drain pipe of 6 mts. Length to drain out the condensate water being formed in the indoor unit.
5. Leak testing the entire gas unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 3 core 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 4 Meters length and up to switch within 3 Meters of location of indoor unit. (Carrier/Voltas/Daikin/Equivalent) | 6 | Nos | - | - |
| 2 | Renewal by Supply and fixing of MS Stand wall clamp support for mounting outdoor unit of split type Ac unit complete. | 6 | Nos | - | - |
| 3 | Renewal by Supply and fixing of 5/8" and 3/8" Copper Pipes with insulation foam of 6 mm thickness suitable for split type AC unit. | 53 | Mtr | - | - |
| 4 | Renewal by Supply and fixing water drain pipe line (1" PVC pipe) | 74 | Mtr | - | - |
| 5 | Add GST @ 18% | 1 | Nos | 1 | ₹1 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
CONDDEAN19PDF.pdf
Tender Documents • 1.07 MB
BOQ_849205.xls
BOQ • 0.33 MB
ICUpdktcondition.pdf
PDF • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .