Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹3.6 L+₹46,525.98 (15.0%)Rejected-Finance | L2 | Rejected-Finance That the bid is not L1 | |
| 3 | L3₹3.7 L+₹58,198 (18.8%)Rejected-Finance | L3 | Rejected-Finance That the bid is not L1 | |
| 4 | L4₹4.4 L+₹1.3 L (40.4%)Rejected-Finance 10 11 UMACHARAN BHATTACHARYA LANE SHIBPUR HOWRAH 711101 | HOWRAH | HOWRAH | WEST BENGAL | 711101 | L4 | Rejected-Finance That the bid is not L1 | |
| 5 | L5₹5.1 L+₹2.0 L (65.1%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L5 | Rejected-Finance That the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹7,835
Closing Date
15 Feb 2023, 1:00 pmClosed
ASSISTANT ENGINEER KMCH
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus
Electrical Installation work at Outside Shed for patient waiting purpose at RIO, Kolkata.(Electrical work)
2023_WBPWD_463585_1
WBPWD/AE/KMCESD/NIQ-74/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,835
10 Sept 2024
1 Feb 2023
17 Feb 2023
7 Feb 2023
15 Feb 2023
7 Feb 2023
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed FRLS copper wire (Make: Gloster / RR Kabel / polycab) in 20mm size PVC rigid conduit (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish(P-E14/Item-2g) . Avg run 12 mtr
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make-MMS] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (PWD Schedule Page- E-16/Item-7) 20mm dia.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire(Make: Gloster / RR Kabel / polycab) ) in prelaid PVC rigid conduit 'FR' (Precision make) /polythene pipe incl. necy. fittings as required (P-E9/Item-1) i) 2x1.5 sqmm + 1x1.5 sqmm copper wire (For separate plug)
ii) 2 X 4 sqmm + 1 x 2.5 sqmm ( for timer AC)
iii) 2x6 Sq.mm + 1x4 Sq.mm copper wire.
C. Plug & Sockets:--- Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make: Gloster / RR Kabel / polycab) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Legrand Mylink/Schneider/Havells) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish (P-E20/Item-3) Onboard
S & F 250V, 2nos 5A plug point incl. s & f 2 no. 5A switch (Anchor) in 175 x 100 x 65mm Powder coated (CEC make)MS box concealed in wall, backelite cover flushed in wall as to GS.
S & F OF BDB,PDB,VTPN ETC. Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand /L&T) as to GS.( 4 way DB) Vide page no D-11 item no 14
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand /L&T) as to GS.( 6 way DB) Vide page no D-11 item no 14
Supplying and fixing (2+12)way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Mk.-Legrand/L & T)(as per PWD Schedule page No-D09/Item-13)
Supplying and fixing 240V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (PWD Schedule Page No-D-6/ Item-7) (a) 6-32A SP MCB (Mk.-Legrand/L & T)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection (PWD Schedule page No- D-5/Item-D-6) (Make-Legrand /L&T) i) 40A DP Isolator
ii) . 415 V ,100 A FP for PBDB
Supply & Fixing Socket type fan regulator (Step type) (Anchor) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.(P-E6/Item-18a)
SUPPLY OF LIGHT FITTINGS :- S&D 4 feet long single commercial LED type light (1x18w) LED Tube lamp (MK Philips, master LED 18W/Crompton/ Jaquar - as per choice of EIC)
S&D 4 feet long Single commercial LED type Fluoresent light fittings (philips make cat no TMC-501 P 1 x T-TLD 20 W /Crompton / Jaquar - as per choice of EIC)
Supplying & D of LED bulk head light fitting (Philips Endura , cat no-- WT202W LED 6S CW PSU S2 PC or eqv. In all respect Osram / Jaquar/Crompton) complete set.
S & D 120 W LED outdoor Streeet Light Fittings complete with all accessories incl. Making necy. Connections( Crompton make cat no. LSTN-120-CDL-M) . (Ref crompton catalog )
D. Supply of cables :--- Supplying and Delivery of 1.1 KV Gr. following sizes Al. armoured PVC / XLPE insulated cable (Mk. Gloster / Polycab / Havell's) as mentioned below : 4 core 35 sqmm (from VTPNDB to PDB)
E. Laying of cables :--- Laying of 4 core 35 sqmm Al. armoured PVC/XLPE cable with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below : (from VTPNDB to PBDB) (Vide page no F-1,F-3 Item no 2 ,5, 6) i) on wall by clamp
ii) Concealed in wall
FIXING OF LIGHT FITTINGS :- Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only the Bulkhead fittings inside the Waiting shed with nut bolts incl. connection with ceiling rose.
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.(Vide page no C3 Item no 19)
Supplying & Fixing of PVC water proof type Loop box(Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC. & 63A FP MCB (L&T) having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,one NL on porcelain insulator etc. on wall as per direction of EIC (make-sintex) (vide A/no-127/T(E) of 20-21 it no-45)
S & D OF FAN:- S & D 1200mm sweep AC ceiling fan with all accessories on existing fan clamp as per requirement (Make-CGL, HS Plus, 5 star rated/ Usha , 5 star/Orient Energy Star)
FIXING OF FANS :- Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. Vide page no C-3, Item no 21.a.
MISCELLANEOUS Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop. Vide page no C-3, Item no 24.a.
Extra for additional one letter incl. Hifen, stroke and stop as per GS. Vide page no C-3, Item no 24.b
Painting upto 10 letters of the engraved number with approved black /red paint as required. Vide page no C-3, Item no 26.a.
Extra painting for additional one letter of the engraved number with hifen, stroke etc. with black or red paint. Vide page no C-3, Item no 26.b.
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)(Page-D14/Item-30)
Supply & errection of PVC adaptable trunking system (for covering all kind of utility service, hanging wires etc.)on wall incl. all accessories all complete. Size- 150x50mm (Mk-Legrand,Cat No-010432)
Supply & errection of flexible cover for PVC adaptable trunking system complete with all accessories. Size- 150x50mm (Mk-Legrand,Cat No-010524)
Supply & errection of PVC adaptable trunking system base joint all accessories all complete. Size- 150x50mm (Mk-Legrand,Cat No-010691)
Supply & errection of PVC adaptable trunking system cover joint all accessories all complete. Size- 150x50mm (Mk-Legrand,Cat No-010804)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.vide pg no F-5 item no. 9 (i)2.5 sqmm
(ii) 4 Sq.mm copper wire
(iii) 6 sq.mm copper wire
S & D of SMS / DMC type terminal block insulator of 200 Amp capacity (AC/DC)
S & D of digital time switch (L & T GIC make / ABB Make)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
T. K. ENTERPRISE
Messrs HI- Q - ENTERPRISE
M/S ELECTRO POWER
M/s Singh Electrical Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .