Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹24.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹32.8 L+₹8.6 L (35.4%)Rejected-AOC | ₹32.8 L+₹8.6 L (35.4%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹34.0 L+₹9.8 L (40.4%)Rejected-AOC | ₹34.0 L+₹9.8 L (40.4%) | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹48,440
Closing Date
30 Jun 2021, 5:00 pmClosed
GE GOMANTAK VASCO
GE GOMANTAK VASCO DA GAMA VASCO GOA PIN403802
Provision of Shed for DG set POL store and Pressure Testing Equipment at BWS Goa and Provision of Deficient facilities at NAI GOA under GE Gomantak Vasco
2021_MES_448588_1
8265/E8
Open Tender
Support/Maintenance Service
Works
180 days
VASCO DA GAMA
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹48,440
Yes
8 Nov 2021
4 Jun 2021
1 Jul 2021
4 Jun 2021
30 Jun 2021
14 Jun 2021
Amount
Schedule 'A' Part I B/R Portion
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock all as specified and as directed.
M&L for Cement concrete (1:4:8) type D2 as in foundations, filling and mass concrete all as specified and as directed.
M&L for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar complete all as specified and directed.
Use & waste of Formwork to sides of pilars, posts, struts, piers, columns and stanchions, rough finished surfacdes of concrete all as specified.
Formwork to sides and soffits of roof beams, beam, haunchings, girders, bressummers, including supports, overhangs, etc. aslo splays between floors and beams, etc. complete all as specified and directed.
Use & waste of Formwork to chajjas, incl edges and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.
Use & waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.
M&L for RCC (1:1½ :3) using (20mm graded stone aggregate) as in foundations footing, plinth beams, bases for clumns and basement slab, under reamed piles and mass concrete complete all as specified.
M&L for RCC (1:1½ :3) using (20mm graded stone aggregate) as in columns, pillars, posts & struts complete all as specified.
M&L for RCC (1:1½ :3) using (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for RCC (1:1½ :3) using (20mm graded stone aggregate) as in chajjs complete all as specified.
M&L for RCC (1:1½ :3) using (20mm graded stone aggregate) as in roof slab supported on walls, beams and columns (Horizontal or sloping) complete all as specified.
M&L for Pre-cast cement concrete type C1 (1:3:6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc 25cm thick soil complete all as specified and directed.
Removing excavated materials (soft/dis integrated rockl) to a distance n.exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M&L Hard core, broken to gauge n exc 63 mm for plinth protection/under floor as directed by Engr in charge.
Material & Labour for Cement concrete type B-1, 1:2:4 (20mm graded) 40 mm thick PCC as in hard standing incl necessary form work etc complete.
M&L 75 mm thick cemet concrete type, C2 1:3:6 using (40 mm graded aggregate) as in plinth protection finish the surface even and smooth all as specified and as directed.
M&L for machine cut Kota stone slab of size 600mm x 600m x 18 to 20 mm thick as in flooring, laid and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finished complete over and including screed bed if 15mm thick in CM 1:6 all as directed.
M&L for machine cut Kota stone slab of 18 to 20mm thick, in riser of steps, skirting, dado etc. over & including 10mm thick rendering (bedding layer) in CM 1:4, laid and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finished complete.
M&L 100mm thick for cement concrete type, C2 1:2:4 (20 mm graded aggregate as in flooring finished even and fair using extra cement.
S & F Glass dividing strips, 3 mm thick and 22mm width inserted in position, conform to design complete all as specified and directed.
M & L 15 mm thick rendering on fair faces of concrete in CM 1:6 finish the surface even & smooth without using extra cement complete all as specified and directed.
M & L 15 (10+15) mm thick rendering in two layer on fair faces of concrete in CM 1:4 finish the surface even & smooth without using extra cement complete all as specified and directed. (NOTE : ll nd coat 5mm thick with WPC)
Supply only Liquid water proofing compound.
M & L for rendering in CM 1:3, 10 mm thickness on top of roof slab finishing the surface even and fair without using extra complete all as specified and directed.
S &F water proofing treatment to the roof slab and chajja using 4mm thick APP modified membrane sonsisting five layer menbrane with features as specified, weighing not less than 4.0 kg/Sqm laid over a coat of cold applied bituminous primer @ 0.2 litre per Sqm on surface provide a layer of APP modified membrane by torching application including sealing the overlap with torching with 150 mm on length side and 100 mm on width side as per manufacturer's instruction including joints and changes in direction be covered with thin cement slurry in CM 1:3 mixed with SBR latex @ 200 ml/bag of cement cuved well before laying of membrane all as per manufacturer's instructions and provide a finishing coat with solar reflective bituminous aluminium paint @ 0.10 kg/m2 as prescribed by manufacturer if membrane to the satisfaction of Engineer-in-Charge. Note:- 1. Irrespective of the lap the net covered area will only be measured for payment.
M&L 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pined joints
Material & Labour for Cement concrete type B-1, 1:2:4 (20mm graded) PCC bed for Holdfasts.
M&L sanding newly tarred or painted surfaces with clean sharp sand all as specified and directed.
M&L Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint.
M&L treating small articles such as stop, covers, gully gratings, holdfasts,ends of posts, backs of chowkasts, etc. area n exc 0.1 sq. m each.
M&L 35 mm thick 2nd class HW plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats.
M&L for preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M & L for steel window with side hung shutter including hinges, handle, pegstays with glazing bars complete.
S&F for 4mm th sheet glass ordinary quality, pane n.exc 0.5 sqm each.
M & L for Two coats of synthetic enamel paint to newly steel surfaces.
S&F 100mm long Stainless steel Butt hinges fixed to door frame.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed
S&F 150mm long Fancy type Aluminium handles, cast type, anodised.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S & F powder coated (50 micron) window or ventilator shutter and frame any type (slidding or openable) with frame or other similar work etc section fabricated by using the JINDAL/INDAL/HINDALCO/sections including necessary roller, wheel clear handals locking arrangements also to receive 4.8mm thick glass with aluminum chanel beading and stainless steel scrw including and rubber gasket beading etc complete (the weight of rubber gasket beading will not be measured with the weight of aluminum shuter glass will be measured and paid separately) All scections as approved by GE.
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/Rectangular n exc 0.5 sq. m in each pane complete all as specified and directed.
Supply and fixing Aluminum powder coated deco grill make DG 104 (10 mm thick section) with frame of section not less than 0.136 kg/rm.
S&F aluminum alloy anodised wire mesh of size 1.5mm x 3 mm mesh 20 Gauge thick of make M/S Kiran Netting or equivalent as approved by GE.
S&F 500 Ltrs Rotational moulded polyethylene water storage tanks sintex (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S & F 20mm Ball brass valves high pressure with polythine float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F 25mm dia stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 25mm- 92gms) complete all as specified and directed.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed.
S&F 25mm Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to, ceilings or in floors etc., any type of pipe all as specified and as directed.
S&F 15mm Unplasticised PVC pipes od pressure rating 10 kgf/cm2 fixed complete to conseled in walls walls, ceilings or in floors etc., any type of pipe all as specified and as directed.
S&F 110 mm dia PVC (SWR) vent pipes single socketed in any length with rubber rings joints all as specified and as directed.
S&F 15mm dia chromium plated Bib taps, screwed for iron pipe. Complete all as directed.
M & L for three coats of white wash on newly plastered celing surfaces all as specified and as directed.
M&L for preparation of new plastered surface & applying two coats of oil bound distemper (OBD) over a coat of white chalktening on wall complete all as specified and directed by Engineer-in-charge.
Material & Labour two coats of acrylic emulsion extenior paint (anti fungal painting-APEX or Equivalent) over a coat of acrylic amulsion primer including preparation of new concrete surface of any descripton all as specified and directed by Engr-in-Charge.
S&F for Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections (Fe-290 (Gde E-165).
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings, MS pipe for post and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc (Fe-290 (Gde E-165).
S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Fe-290 (Gde E-165).
M&L for appling two coat of Anti corrosive enemal paint over a coat of primer on new steel surfaces of any position not otherwise described over 10 cm width or girth including preparation of surfaces all as directed/specified.
Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
Dismantling of Plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof overings.
Dismantling wrought iron or mild steel work of any description not otherwise provided
Demolition of Brick work or stone/boulder masonry, built in Cement mortar including all quoins, archers, pillars, etc, but excluding ashlarfacings, dressed stonework and precast concrete articles all as specified and directed by Engr in charge.
Excavating in post holes (Or similar) each n exc 0.50 Cum getting out returning filling in ramming earth or broken rubble mixed with each around, in layers n exc 25 cm watering and removing surplus soil to a distance exc 50 m and making good surface.
M&L for preparation of new steel surfaces and apply two coat of synthetic enamel paint over a coat of anti corresive primer.
M&L for preparation of new plastered surface and applying two coats of white wash.
M & L for PCC 100mm thick 1:4:8 type D2 using 40 mm graded aggregate.
M&L for Sand cushioning 50 mm thick spread, levelled, compacted to recive interlocking tiles all as specifed and directed.
M&L for Machine pressed rubber mould pre cast concrete interlocking pavar blocks (with grey cement and pigment) any shape and size conforming to IS-15658-2006 of 80 mm thickness, M-40 grade all as specified and directed.
Dismantling post or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground, post embedded in concrete complete all as specified and directed.
Excavation in post holes each not exceeding 0.50 cum getting out, returning filling in and well ramming earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50 mtr and making good disturb surfaces as in soft/loose soil.
M & L cement concrete type C1, 1:3:6 (using 20 mm graded aggregate) as in post hole and foundation filling and mass concrete all as specified and as directed.
S & F mild steel work like angle iron, flat iron etc in posts and struts in fencing incl cutting tops to shape as directed, drilling holes, notching for wire etc including all necessary drilling conforming to Fe 290 Gde E-165.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square length of bolt exc 5cm and n exc 10cm long and 12mm dia.
Supply only Mild Steel galvanised chainlink fencing any size (100x100x4mm dia) including provisioning of binding wire all as spcified and as directed.
Fixing only Mild Steel galvanised chainlink fencing any size or type of standard, rails etc including provisioning of binding wire all as spcified and as directed.
M&L for Two coats of synthetic enamel paint over one coat of primer including preparation of new steel surfaces all as spcified and as directed.
Schedule 'A' Part II E/M Portion Internal Electric Supply
M & L for one point wiring with 1.5 sqmm PVC insulated un-sheathed cable with stranded copper conductor FR-LSH confirming to IS : 694 of size 1.5 Sq mm single core, including one No 1.5 Sq single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn through and incl concealed stove enamelled steel conduit of 20mm dia size including all accessories etc as required of suitable dia for one light / exhaust fan point controlled by one flame proof switch complete as directed.
Supply and Fixing of flame proof 2X16/20 watt LED tube light fitting fitting with IP65 protection complete with all accessories ,internally pre-wired including conecting up with suitable size twin core FRLS copper conductor as directed . Make: Crompton/Bajaj/Sudhir/Havells
S & F Flame proof exhaust fans AC single phase 230/240 V of size 305 mm sweep,1440 RPM with louvers all as specified.
Supply and Fixing of flame proof rotory switch in LM-6 enclosed in and including aluminium body enclosure with threaded cover with toggal action switch operated by a shrouded knob single pole, 10 Amps with double entries through way suitable for 20mm dia ERW threaded rigid steel conduit and 01 No MS plug of 20 mm dia . Make- SUDHIR Cat part No RI/A/146-3 (or) equivalent Make- BALIGA/FCG Power
Supply and Fixing of flexible metalic hose conduit from junction box to tube light fitting not less than 500mm long of size M20/3/4" conduit M x M / FM x M / F 500mm Make- SUDHIR Cat part No MH/145 (or) equivalent Make- BALIGA/FCG Power
Supply and Fixing of 90 degree flameproof bend Make- SUDHIR Cat part No BN/C/165 (or) equivalent Make- BALIGA/FCG Power
Supply and Fixing of flameproof Union (MXF) Make- SUDHIR Cat part No ACC/2C/2019 (or) equivalent Make- BALIGA/FCG Power
Supply & Fixing sheet metal enclosues(DB) for MCB's, 2 way ,single pole & neutral ,240 volt,double door with IP-43 complete.
Supply & Fixing sheet metal enclosues(DB) for MCB's, 4 way ,single pole & neutral ,240 volt,double door with IP-54 complete.
Supply & Fixing SPN MCB,AC, 'C' curve , 230 V, 6-32 Amp complete.
Supply & Fixing SP MCB,AC, 'C' curve , 230 V,0.5 - 6 Amp.
Material and labour for earthing complete with GI steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including necessary earth work and excavation of in any type of strata, chamber in PCC 1:2:4 type B-2 with PCC Cover , GI tubing 20 mm dia for watering and 15mm dia GI tubing for protection of wire etc all as per electrical plate No.3 of SSR part I including connecting to electrical equipments and testing on completion.
Material and labour for point wiring complete as specified with 1100 V grade 1.5 Sqmm two runs of single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS, drawn through and including PVC casing and caping (ISI Marked) with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including one run of 1.5 sqmm single core PVC insulated and unsheathed copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for the following:-
(a) One light/fan/exhaust fan point controlled by one switch.
(b) One 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
Material and labour for point wiring complete as specified with 1100 V grade 4 Sqmm two runs of single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS drawn through and including PVC casing and caping (ISI Marked) with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket etc including 4 Sqmm one run of single core PVC insulated and unsheathed copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for one 6 pin switch socket outlet 15 Amps on independent board controlled by one switch.
Supply & Fixing switch piano flush button single pole one way 05 Amps Make :Anchor
Supply and fix switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal.
Supply and fix switch socket combination 2 in 1, 5 pin, 15 Amp flush type universal.
Supply and fix ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete.
Supply and fixing 25W 4ft long LED batten light fitting with 2.5 KV voltage surge protection ,PF >0.9 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size
Supply & fixing in repairs Brushless DC Motor (BLDC) ceiling fan 1200mm sweep, 5 star rated (ISI Marked), 230 volts least power consuming fan of 26W, having PCB Housing in the bottom canopy including connection rod as per existing size of length of GI pipe medium grade complete incl fan haanging hook all as per specified and directed. Make : Usha/Havells/Bajaj
Schedule 'A' Part II E/M Portion Lightening Protection System
Air termination single pointed aluminium rod 12mm dia and 300mm long complete fixed on insulators all as directed by Engr-in-Charge.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including three Nos 8mm dia 25mm long hex head screw all as specified and directed by Engr-in-Charge.
M & L for Aluminium Strip 25 X 3mm with saddle and fixing screws and clamps for supporting on GI pipe etc for roof conductors and down conductors above ground all as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mm×600mm× 6mm buried directly in ground earth pit not less than 2.25mtr below normal ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including GI strip 32x6mm earth lead by means of 2 nos bolts, nuts,check nuts and washers of galvanised iron upto test point including 20mm dia medium grade GI pipe of suitable length as watering pipe with funnel and wire mesh including excavation and earth work in any type of soil, PCC pit in PCC (1:2:4) type B1 using 20mm grade stone aggregate angle iron frame work with RCC 1:2:4 cover 40mm thick reinforced with 8mm dia deformed bars @ 150mm C/C both ways and handlecomplete all as shown in electrical plate No 3 of SSR 2009(Part-I) and testing on completion.
M & L for GI strip 32x6 mm buried in ground as earth continuity conductor for loop earthing all as directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
Removal of disintegrated rock to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
Schedule 'A' Part II E/M Portion External Electric Supply
Supply ,laying & testing XLPE insulated PVC sheathed heavy duty LT electric cable 1100 volts grade galvanised steel strip armoured with stranded aluminium conductor cross sectional area 10 sqmm 2 core,IS-7098 Part-I including centre gland, lugs,jointing materials etc laid in trenches/road crossing/on pole or wall etc .all as specified and directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in Soft disintegrated rock .
Material & Labour for fine river sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cm for cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment.
Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm.
M & L for GI tubing (light grade) with all fittings,laid in trenches, or fixed along with walls /poles,bore of pipe 40mm for cable protection.
SACHIN CONSTRUCTIONS
M/s Gayatri Contruction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .