Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 11 97 SADALATLIGUDA CHOWDARIGUDA HYDERABAD TELANGANA 500088 | MEDCHAL MALKAJGIRI | TELANGANA | 500088 | L1 | Accepted-AOC BEING LOWEST AND ACCEPTABLE | |
| 2 | L2₹19.2 L+₹72,515.50 (3.92%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹20.7 L+₹2.2 L (12.0%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹21.2 L+₹2.7 L (14.4%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹19.2 L
EMD Value
₹38,500
Closing Date
2 Oct 2024, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR PIN-342011
PROVN OF DG SET AT TECH AREA AT AF STN JAIPUR
2024_MES_671335_1
88083/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) AF JAIPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF JAIPUR
₹38,500
Yes
18 Oct 2024
4 Sept 2024
4 Oct 2024
4 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
Supply, Installation, testing and commissioning of Factory Assembled silent Diesel Engine driven generating set,415volt, 3 phase, 4wire,engine as per IS 10002/10001 and alternator as per IS 13364 of capacity 100 KVA at 0.8 PF, complete with sound proof canopy made of powder coated with specially designed lifting hooks, meet the latest CPCB IV norms of 75DB at 1 M distance at 75% load, Inbuilt AMF Panel and PCC foundation with Anti Vibration Mounts (AVMs) as per OEM Manufacturer guideline all as spd and directed and comprising of following :- (a) Engine: 4 cylinder, In line,1500 RPM, water cooled, four stroke, rated power 92 Kw, diesel engine for 100 KVA alternator as per is 10002/10001 with sensor for low oil pressure, high water temprature including microprocessor based engine control panel , 12V DC start system with battery and fuel tank for 8 hr run all as spd and directed. (b) Alternator: alternator of rated capacity 100 KVA at 1500 RPM, 0.8 lagging pf, 415 volts, 3 phase, 4 wire, Brushless,Single Bearing,self excited, self regulated an AVR with +- 1% voltage regulation, class H insulation all as spd and directed. (c) Control Panel: Control panel should have following parameter (i) Genset DIsplay Parameters( Line/Phase Voltage, Line Current,Frequency,Avg Voltage,Avg Current,Phase and Total KW,KWh and PF) (ii) Engine Display Parameters( Coolent Temp,Fuel status,Speed,Running Hrs, No of Starts, Battery Voltage. (iii)Electrical safeties(Under/Over voltage,Under/over frequency,Phase failure, Phase sequence reverse,over current,over kw) (iv) Mechanical Safeties (Under/OverSpeed,Low Lub oil Pressure,High engine coolant temprature,Battery charging indication,Low fuel level,start/stop fail. Location: Airforce station Technical Area . Make: Cummins/Ashok Leyland/Caterpillar
Excavation in trenches not exc 1.5 mtrs wide & not exc 1.5 mtrs in depth for taking out/laying of pipes/cables etc & getting out in Hard/Dense soil complete all as specified and directed .
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed .
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground cables of size. Outer/Inner dia of pipe 50/38 mm with all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately). Rate for Inserting cable in pipe deemed to be included in quoted rate.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, using galvanised iron strip 25×4mm as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. NOTE : (i) Earth resistance value should be less than 5 Ohms (ii) Item includes the cost of 7.5 m GI pipe for protection of earth strip.(iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quoted rate. (iv) excavation and earth work shall be measured and paid separately.
S&F MCCB 3 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA complete all as specified and directed
LAKSHMI ASSOCIATES (BID ID -3107363)
M.S. ENTERPRISES (BID ID -3123038)
PRAJAPATI E and S ENGG CO (BID ID -3121915)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .