Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
20 Nov 2026, 11:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
SANDEEP SINGH
POWERGRID CORPORATION OF INDIA LIMITED FARIDABAD, SECTOR-16A
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
NR1/NT/W-CIVIL/DOM/I00/26/13920
Open
Civil - All
Works
Jind
₹5,000
₹2.2 L
26 Oct 2026
26 Oct 2026
24 Nov 2026
26 Oct 2026
20 Nov 2026
26 Oct 2026
Package Name Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Specification No. Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702)
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682)
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-4, Sch-7 and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-4b (Maintenance Charges during and after Defect Liability Period) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Sole Bidder 1 Sole Bidder 1
Joint Venture 2 or More JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 1 0 Sole Bidder 1 0
Name of Sole Bidder
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1 POIU
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682) Schedule - 2 Dis
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
#REF! To: As per Percent on Sch-2 #REF!
#REF! #REF! Total Discount #REF!
Name : #REF! #REF!
Address : #REF! #REF!
#REF! #REF! Multipackage Discount #REF!
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : #REF! Printed Name : #REF!
Designation : #REF!
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Schedule - 1
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. 0.0 Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. 0.0 SCO Bay 5-10, near Haryana Pollution Control
…….. …….. …….. …….. …….. …….. 0.0 board Office, Sector 16A, Faridabad, Haryana 121002 Multipackage lum-sum 0.00%
INSTALLATION CHARGES Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Header PR Activity No DSR CODE Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
PART A (Substation Portion)
1 15.58 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantledmaterials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. 18 2.34.1 Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos/ Lindane emulsifiable concentrate of 20% cum 5.00 Included 0.00 0 0
2 2.10.1.2 Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 18 2.35.2 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall below concrete or masonry apron using chemical emulson @ 2.25 litres per linear metre including drilling & plugging holes etc. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Rmt 8.00 Included 0.00 0 0
3 4.2.8(M) Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)/40mm nominal size bricks bats. 18 15.7.4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar Cum 8.36 Included 0.00 0 0
4 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to f loor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 18 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm cum 18.20 Included 0.00 0 0
5 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 18 DSR 14.83 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. cum 63.08 Included 0.00 0 0
6 5.9.1 Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete 18 DSR 14.82 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge sqm 50.00 Included 0.00 0 0
7 5.9.3 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 18 DSR 15.60 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. sqm 298.77 Included 0.00 0 0
8 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers 18 DSR 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). sqm 429.72 Included 0.00 0 0
9 5.9.6 Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts 18 DSR 5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers sqm 245.57 Included 0.00 0 0
10 5.9.7 Centering and shuttering including strutting, propping etc. and removal of form for: Stairs, (excluding landings) except spiral-staircases 18 5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. sqm 18.81 Included 0.00 0 0
11 5.9.19 Centering and shuttering including strutting, propping etc. and removal of form for: Weather shed, Chajjas, corbels etc., including edges 18 DSR 11.4 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. sqm 25.49 Included 0.00 0 0
12 5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 18 DSR 13.1.1 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Kg. 16076.71 Included 0.00 0 0
13 6.4.2 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 18 DSR 13.16.1 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) cum 95.28 Included 0.00 0 0
14 6.13.2 Half brick masonry with common burnt clay F.P.S. non modular bricks of class designation 7.5 in superstructure above plinth level up to floor V level. - Cement mortar 1:4 (1 cement: 4 coarse sand) 18 DSR 13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. sqm 275.46 Included 0.00 0 0
15 6.15 Extra for providing and placing in position 2 Nos., 6mm dia M.S. bars at every third course of half brick masonry. 18 DSR 6.47 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). sqm 181.76 Included 0.00 0 0
16 8.2.1.1 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble. Area of slab upto 0.50 sqm 18 Making opening in walls :Making openings in existing walls for doors, Cables, Service pipelines, AC ducting etc. without damaging the surroundings and making good the affected areas with smooth plaster in mix proportion 1:4, inclusive of lintel support in Cuddapah stone of thickness 25mm to be provided where ever required. Cost to be inclusive of filling the excess opening with brick bats and finishing the same in smooth plaster in cement mortar 1:4 & applying waterproofing treatment, proper curing, giving supports to walls, etc. complete & disposal of debris at location off the premises at specified location or as directed by Site -in-charge. sqm 26.16 Included 0.00 0 0
17 8.2.1.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble. Area of slab over 0.50 sqm. 18 Providing and fixing 150mm thick (overall) 2-Hour Fire Rated, triple-layered drywall partition with acoustic insulation, using a heavy-duty structural G.I. framework. The framework shall comprise 90mm G.I. floor and ceiling channels (90x45x0.9mm thick) and 89mm G.I. 'C' studs (89x44x12x0.9mm thick) placed at 600mm c/c. The cavity shall be infilled with 100mm thick Rockwool insulation (68 kg/cum density) for sound insulation (Thermal conductivity of 0.461 w/mk). The framework shall be clad on both sides with three layers of boards (total 30.5mm thickness per side). First (inner) layer: 8mm thick Cement Bonded Particle Board (as per IS: 14276) fixed with 25mm self-drilling screws. Second (middle) layer: 10mm thick Cement Bonded Particle Board fixed with 38mm self-drilling screws. Third (outer) layer: 12.5mm thick Gypsum board fixed with 50mm self-drilling screws. All joints between the three layers must be staggered to avoid through-joints. All boards to be fixed to the GI framework at 300mm c/c. The outer gypsum surface shall be finished flush using jointing tape and gypsum jointing compound as per the manufacturer's specifications to provide a seamless surface ready for primer and painting. Perimeter gaps/expansion joints to be sealed with a 6mm dia backer rod & Elastomeric sealant. All materials and execution complete as per drawings, BS 476 fire resistance standards, and the direction of the Engineer-in-Charge. sqm 69.09 Included 0.00 0 0
18 8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red. Area of slab over 0.50 sqm. 18 Providing and fixing 100mm thick (overall) double-layered dry wall partition with a 1-Hour Fire Rating, using a structural G.I. framework. The framework shall comprise 51mm floor and ceiling channels (0.55mm thick, 32mm equal flanges) and 51mm G.I. studs (0.55mm thick, unequal flanges of 40mm and 42mm) placed at 600mm c/c. The cavity shall be infilled with 50mm thick Rockwool insulation (60 kg/cum density) for sound and thermal insulation (Thermal conductivity of 0.461 w/mk). The framework shall be clad on both sides with a double layer of boards. The first layer shall be 12mm thick Cement Bonded Particle Board (as per IS: 14276) fixed with 25mm self-drilling screws. The second (outer) layer shall be 12.5mm thick Gypsum board fixed with 38mm self-drilling screws. Joints of the two layers must be staggered to avoid through-joints. All boards to be fixed to the GI framework at 300mm c/c. The outer gypsum surface shall be finished flush using jointing tape and jointing compound as per manufacturer's specifications to provide a seamless surface ready for primer and painting. All materials and execution complete as per drawings, BS 476 fire resistance standards, and the direction of the Engineer-in-Charge." sqm 10.86 Included 0.00 0 0
19 8.4 Extra for fixing marble OR granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 18 INTERIOR GRADE COMPACT HIGH-PRESSURE LAMINATE (HPL): Providing and fixing 6 mm thick High Pressure interior compact Laminate from urea free, self-supporting General Purpose Compact Laminates containing thermosetting phenolic resins treated Kraft papers as core material and Amino plastic resin treated decor papers on the finish surface. Compact laminates should fulfil the criteria of fire rating classification as per the applicable standard. These self-supporting compact laminates conform to CGS grade as per IS:2046-1995, EN 438:2016 and NEMA LD3-2005 quality standards. The compact laminates with Antibacterial and Antifungal properties (conforming to JIS Z2801:2010 and ASTM G21-2015 standards respectively) and fulfils the applicable indoor air quality ertifications for Greenguard-Gold, GRIHA and GreenPro certification. Compact laminates/boards should be resistant to immersion in boiling water for 2 hours and show an increase on thickness and mass <2%, boards to have a density >1.35 gm /cm3. The compact board should be Impact resistant, termite resistant, scratch resistant, Surface wear resistance, Resistance to color fastness and such performance properties as per the requirements of the applicable IS, EN or NEMA standard. (The manufacturer should provide 10 years warranty on manufacturing related defects.) Finish and color of compact laminates should be finalized under direction of Engineer – in-charge. Compact laminates should be installed on 25 x 50mm aluminum tube or an approved tube size fixed at a maximum center-to-center distance of 600mm and full length equivalent to the length of the compact board. Fixing should be as per riveting or screws or by adhesive with appropriate provisions for expansion gaps. Finish and color of Interior clads should be approved under engineer-in-charge direction. metre 10.61 Included 0.00 0 0
20 9.46.3 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 25 mm dia 18 Supplying Sintered Stone of size 3000 mm × 1200 mm with minimum 5.5 mm thickness, manufactured through an advanced sintering process using 100% natural raw materials, free from resin, binders, and factory-reinforced with fiberglass mesh backing for enhanced strength and safety, suitable for exterior and interior wall applications with matte and slip-resistant finish, weighing approximately 45 kg per slab, the slabs shall have surface hardness minimum 8 on Mohs scale, breaking strength minimum 1000 N, water absorption 0.08%, stain resistance Class 5 (cleanable with hot water), fire classification Class A2S1d0 (non-combustible), and resistance to chemical attack, atmospheric pollution (smog), frost, thermal shock, UV radiation, and bacterial growth,SRI 95 NSF certification, IGBC compliance, minimum 25-year warranty against colour fading from the OEM. metre 58.72 Included 0.00 0 0
21 9.47.2 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) 18 Installation of Sintered Stone of size 1200 × 3000 × 5.5 mm, as per approved drawings and design, shall be carried out using aluminium rectangular tubes of size 25 × 50 mm with minimum 1.5 mm thickness. All aluminium sections shall be of approved make and quality, free from defects and corrosion. Approved structural sealant and aluminium cleat L-angles of size 25 × 25 mm with 1.5 mm thickness shall be used for aluminium framing of the slab. Aluminium L-brackets of size 50 × 50 mm with SS anchor fasteners shall be used for erection and anchoring of the aluminium framing to RCC / masonry walls. All fixing screws shall be SS self-tapping type, corrosion-resistant. Vertical runners of aluminium rectangular tubes shall be fixed at maximum 600 mm C/C, and horizontal runners shall be fixed at maximum 1200 mm C/C, ensuring proper alignment, level, and plumb. Prior to fixing the slab, the substrate surface shall be thoroughly cleaned, dry, and free from dust, oil, and loose particles. Approved VHB tape shall be applied as a temporary holding medium along with structural sealant to ensure proper bonding. Adequate expansion and movement joints shall be maintained as per manufacturer’s recommendations. All joints between slabs shall be sealed using weather-resistant silicone sealant of approved colour, with masking tape applied to achieve neat and uniform joint lines. The installation shall be carried out strictly as per manufacturer’s guidelines, specifications, and as directed by the Engineer-in-Charge / Architect. metre 8.92 Included 0.00 0 0
22 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 18 Supply and Installation of 12mm Plain/textured PET Acoustic panels ,density 2400 GSM, ASTM E84 Class A fire rated, low VOC, and suitable for green building certification. V-grooving must be executed using a CNC machine to ensure precise, smooth cuts in accordance with the design provided by the Architect or EIC. Any color as per approval of EIC/Architect from Acoustics Shade card. Kg. 200.00 Included 0.00 0 0
23 9.68.1 Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete (Copper oxidised as per IS 1378) : 300 mm weighing not less than 330 grams 18 Supply and Installation of 12mm PET Acoustic Privacy Screen, 100% Polyethylene Terephthalate (PET), Density: 2400 GSM, ASTM E84 Class B Fire Rated, Low VOC, NRC Certificate and Testing 100Hz to 5000Hz and Response on various frequencies. Any color as per approval of EIC/Architect from Acoustics Shade card. each 80.00 Included 0.00 0 0
24 9.79.2 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.: 50 mm 18 Supply and Installation of 12mm Premium high quality Printed PET Acoustic Sheet, 100% Polyethylene Terephthalate (PET), Density: 1750 GSM, ASTM E84 Class B Fire Rated, Low VOC, NRC Certificate and Testing 100Hz to 5000Hz and Response on various frequencies. Qualified for Green Building Certification.Printing must be done with UV Printer and should not fade atleast for 5 years. Printing will be as per design given by Architect. each 25.00 Included 0.00 0 0
25 9.80 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. 18 Supply and Installation of 12mm V-Grooving PET Acoustic panels ,density 2400 GSM, ASTM E84 Class A fire rated, low VOC, and suitable for green building certification. V-grooving must be executed using a CNC machine to ensure precise, smooth cuts in accordance with the design provided by the Architect or EIC. Any color as per approval of EIC/Architect from Acoustics Shade card. each 16.00 Included 0.00 0 0
26 9.81.2 Providing and fixing bright finished brass handles with screws etc. complete: 100 mm 18 Providing and fixing Premium Acoustic Wooden Tiles / Wall Panels for ceilings/internal wall cladding , engineered for high acoustic performance and aesthetics. The base material shall be selected from standard options including Standard MDF / Pine Eco-Friendly MDF / Green Moisture Proof MDF / Black HD / Plywood / Teak Wood / Oak Solid Wood / Fine Wood , having a panel thickness of 15mm The panels shall feature factory-approved surface finishes in laminate or premium natural wood veneer (options including Sapeli, Walnut, Mahogany, Cherry, Natural Teak, Beech, Oak, Teak, Maple, Wenge). The backing of the panels must be strictly laminated with an integrated Fire-resistant sound-absorbing fleece. Panels must be allowed to acclimatize in the installation environment for at least 48 hours prior to fixation. Panels shall be fixed with structural GI frameworks framing to the true wall/ceiling soffit structure plumb and level. Fixing Process: Panels must be mechanically locked utilizing secure tongue-and-groove or specialized clip profiles, avoiding visible facial fastenings unless specifically detailed by design. Airflow/Cavity: Maintain a sound-distribution airspace cavity behind the panels as instructed to achieve optimum certified NRC ratings. The acoustic perforation configuration shall be precisely executed in accordance with the design drawings using standard factory models (8-2, 10-2, 14-2, 26-3, 30-2, 60-4, 124-4, or 192) , delivering a Noise Reduction Coefficient (NRC) rating ranging between 0.7 to 1.0 , and meeting Euro Class B-s1,d0 / ASTM E84 fire safety standards. The framework installation involves a GI strut channel/wooden batten grid system securely anchored to the base wall/ceiling soffit, including necessary mounting clips, tongue-and-groove jointing alignments, edge profiles, scaffolding, labor, and final clean-up, completed to the satisfaction of the Engineer-in-Charge each 80.00 Included 0.00 0 0
27 9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 18 Ply Panelling "Providing and fixing Commercial Plywood (BWR grade conforming to IS: 303 / BWP grade conforming to IS: 710) as a single skin base paneling to existing partitions or peripheral masonry walls. The unexposed (wall-facing) surface and all cut edges of the plywood shall be treated with two coats of approved anti-termite and anti-fungal chemical before installation. The plywood shall be fixed perfectly plumb and level using heavy-duty PVC/nylon sleeves and fully threaded Stainless Steel (SS) countersunk screws of appropriate length at a maximum spacing of 300mm c/c both ways. All joints between plywood sheets shall be filled with approved wood filler/epoxy putty and sanded perfectly flush. The exposed face shall be prepared (including necessary sanding, leveling, and application of suitable primer/base coats where required) to directly receive secondary finishes such as Laminate, Wallpaper, Fabric, Glass, Veneer, or Slat panels. The rate shall include making necessary, accurate cut-outs for electrical switch-sockets, data points, and HVAC grilles, ensuring the openings are neatly finished so that no gaps are visible after fixing the faceplates. Work includes all materials, labor, T&P, and staging, complete as per Architect's design, drawings, and the direction of the Engineer-in-Charge." Mode of measurement - Length x height up to True ceiling Quoted rates to include General Notes and all the above points as required and approved by Architect 19 mm thick each 10.00 Included 0.00 0 0
28 9.96.2 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm 18 "Providing and fixing Commercial Plywood (BWR grade conforming to IS: 303 / BWP grade conforming to IS: 710) as a single skin base paneling to existing partitions or peripheral masonry walls. The unexposed (wall-facing) surface and all cut edges of the plywood shall be treated with two coats of approved anti-termite and anti-fungal chemical before installation. The plywood shall be fixed perfectly plumb and level using heavy-duty PVC/nylon sleeves and fully threaded Stainless Steel (SS) countersunk screws of appropriate length at a maximum spacing of 300mm c/c both ways. All joints between plywood sheets shall be filled with approved wood filler/epoxy putty and sanded perfectly flush. The exposed face shall be prepared (including necessary sanding, leveling, and application of suitable primer/base coats where required) to directly receive secondary finishes such as Laminate, Wallpaper, Fabric, Glass, Veneer, or Slat panels. The rate shall include making necessary, accurate cut-outs for electrical switch-sockets, data points, and HVAC grilles, ensuring the openings are neatly finished so that no gaps are visible after fixing the faceplates. Work includes all materials, labor, T&P, and staging, complete as per Architect's design, drawings, and the direction of the Engineer-in-Charge.":Ply Panelling 12 mm thick each 30.00 Included 0.00 0 0
29 9.97.2 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm 18 Ply Panelling "Providing and fixing Commercial Plywood (BWR grade conforming to IS: 303 / BWP grade conforming to IS: 710) as a single skin base paneling to existing partitions or peripheral masonry walls. The unexposed (wall-facing) surface and all cut edges of the plywood shall be treated with two coats of approved anti-termite and anti-fungal chemical before installation. The plywood shall be fixed perfectly plumb and level using heavy-duty PVC/nylon sleeves and fully threaded Stainless Steel (SS) countersunk screws of appropriate length at a maximum spacing of 300mm c/c both ways. All joints between plywood sheets shall be filled with approved wood filler/epoxy putty and sanded perfectly flush. The exposed face shall be prepared (including necessary sanding, leveling, and application of suitable primer/base coats where required) to directly receive secondary finishes such as Laminate, Wallpaper, Fabric, Glass, Veneer, or Slat panels. The rate shall include making necessary, accurate cut-outs for electrical switch-sockets, data points, and HVAC grilles, ensuring the openings are neatly finished so that no gaps are visible after fixing the faceplates. Work includes all materials, labor, T&P, and staging, complete as per Architect's design, drawings, and the direction of the Engineer-in-Charge." Mode of measurement - Length x height up to True ceiling Quoted rates to include General Notes and all the above points as required and approved by Architect 6 mm thick each 50.00 Included 0.00 0 0
30 9.97.4 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm 18 Writable Lacquered Glass Panelling "Providing and fixing of 6 mm thick annealed writable lacquered glass manufactured industrially by curtain coating process with PU lacquer (50 micron thick), conforming to EN 16477 standards for back painted glass , of approved color by Architect/ Client fixed with compatible SGG Glassmate Ultrafix or equivalent - Neutral Alkoxy based Silicone having Shear Bond Strength (Dry, 24 hours), greater than 450 kpa and tack free time of 10 to 30 mins compatible for installation of mirror and lacquered glass ; Mirror mounting tape MIRROR MOUNTING TAPE - Foam based double sided adhesive tape for instantaneous adhesion, compatible with mirror and lacquered glass having Shear bond strength (Dry, 15 mins) of 250 to 350 kpa) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. The contractor should submit test reports for backpainted glass from manufacturer - High humidity Resistance (conforms to BS EN 1036 1999); Color fastness ISO 105B02 standard & Mechanical Resistance ISO 7784 ( Taber Abrasion test ) ISO 2409 ( Cross Hatch Test ) standard The manufactured backpainted glass should be environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strenght (1000 MPa) & tensile strenght (40 MPa),same as float glass." Quoted rates to include General Notes and all the above points as required and approved by Architect On Walls & Partitions each 90.00 Included 0.00 0 0
31 9.97.5 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100x10 mm 18 Ply Box for Junction Box covers (minimum size - 600mm x 600mm) Providing and Fixing of 19mm thk. Commercial Ply frame to cover Junction box to avoid undulations and to provide support to junction box covers, etc. complete as per Architect's instruction, detailed design and drawings. each 120.00 Included 0.00 0 0
32 9.100.1 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 18 Prelam Board Boxing for Cassette AC Providing & fixing Prelam Board Boxing for cassette units fixed in 1200mm x 300mm/ 600mm x 600mm grid ceiling with Aluminium framing as shown in the drawing. Rate shall be inclusive of all necessary cutouts and necessary hardware items required as per design and drawing, etc. complete to the satisfaction of the Architect. each 60.00 Included 0.00 0 0
33 9.100.2 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm 18 Fire Doors Providing and fixing Single leaf Metal Fire Doors of approved make with a vision panel 310mm X 310mm (For Fire Exit) of 120 minutes Rated Insulated Fire Door Tested in accordance to BS: 476 Part – 20 and IS: 3809: 1979, CNP – 2150. Powder Coated Finish of approved Shade Door Frame: Providing of Door Frame of section 120mm X 70mm with fire intumescent seal strip of size 10mm X 4mm for fire and smoke sealing mounted in the grooves of the frame and coated with fire retardant intumescent Primer coating. Concealed drop seal to be considered. Powder Coated Finish of approved Shade Hinges: Providing of ball bearing hinges of approved size with S.S. Screws - 5nos per shutter. Door Closer: Door Closer to be of fire rated of approved make. Handle: Fire rated approved Make & size handles in SS finish to be included in cost.Dead Lock Size: 1200 X 2700mm Single leaf Fire Rated Door with Vision Panel each 110.00 Included 0.00 0 0
34 9.101.2 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper 18 Readymade Trap Door Providing & fixing 600mm x 600mm Moisture Resistant Gypsum Board Access Panel with Powder coated Aluminium framing with stiffners, push-catch closing mechanism with door retaining safety cable and hook, concealed locking arrangement, Single layer of 12.5 mm tapered edge frame is then screw fixed to ceiling section with 25 mm dry wall screws at 230mm center. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. The work shall also include jointing and fixing to a flush finish of tapered edges of Gypsum board with recommended filler, paper tapes and two coats of putty/ primer suitable for gypsum board to achieve a smooth finish as per manufacturer's specifications. (for sizes above 5 sqft), etc. complete as per Architect's instruction, detailed design and drawings. each 40.00 Included 0.00 0 0
35 9.114.2 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type) 18 Solid Core doors Providing and fixing Laminated Door: 35mm thick door with 29mm Solid Core (Stiles & Rails) and 3mm HDF (High Density Fiberboard) skin on both sides. Finished with Laminate (Both Sides - AMERICAN WALNUT Woodgrain or as per approval of Architect/EIC) and 6mm Steam Beech edge lipping. Includes Engineered (LVL) laminated frame (150 x 51 mm), 50mm architraves (12mm thick) on both sides, 45x15mm stops, and factory recesses for hinges and locks. Hardware paid separately. Solid Core doors in Laminate finish Size- 1500 X 2400mm Double Leaf solid Door Opening without Vision panel with D type handles each 80.00 Included 0.00 0 0
36 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 18 Solid Core doors Providing and fixing Laminated Door: 35mm thick door with 29mm Solid Core (Stiles & Rails) and 3mm HDF (High Density Fiberboard) skin on both sides. Finished with Laminate (Both Sides - AMERICAN WALNUT Woodgrain or as per approval of Architect/EIC) and 6mm Steam Beech edge lipping. Includes Engineered (LVL) laminated frame (150 x 51 mm), 50mm architraves (12mm thick) on both sides, 45x15mm stops, and factory recesses for hinges and locks. Hardware paid separately. Solid Core doors in Laminate finish Size- 1200/1000 X 2400mm Single Leaf solid Door Opening without Vision panel with D type handles each 22.00 Included 0.00 0 0
37 10.26.1 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.: M.S. tube 18 Solid Core doors : Providing and fixing Laminated Door: 35mm thick door with 29mm Solid Core (Stiles & Rails) and 3mm HDF (High Density Fiberboard) skin on both sides. Finished with Laminate (Both Sides - AMERICAN WALNUT Woodgrain or as per approval of Architect/EIC) and 6mm Steam Beech edge lipping. Includes Engineered (LVL) laminated frame (150 x 51 mm), 50mm architraves (12mm thick) on both sides, 45x15mm stops, and factory recesses for hinges and locks. Hardware paid separatelySolid Core doors Size- 900 X 2400mm Single Leaf solid Door Opening without Vision panel with D type handles kg 75.00 Included 0.00 0 0
38 11.20.3 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement 18 Solid Core doors Providing and fixing Laminated Door: 35mm thick door with 29mm Solid Core (Stiles & Rails) and 3mm HDF (High Density Fiberboard) skin on both sides. Finished with Laminate (Both Sides - AMERICAN WALNUT Woodgrain or as per approval of Architect/EIC) and 6mm Steam Beech edge lipping. Includes Engineered (LVL) laminated frame (150 x 51 mm), 50mm architraves (12mm thick) on both sides, 45x15mm stops, and factory recesses for hinges and locks. Hardware paid separately. Solid Core doors in Laminate finish Size- 750 X 2400mm Single Leaf solid Door Opening without Vision panel with D type handles sqm 105.34 Included 0.00 0 0
39 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 18 Solid Core doors Providing and fixing Laminated Door: 35mm thick door with 29mm Solid Core (Stiles & Rails) and 3mm HDF (High Density Fiberboard) skin on both sides. Finished with Laminate (Both Sides - AMERICAN WALNUT Woodgrain or as per approval of Architect/EIC) and 6mm Steam Beech edge lipping. Includes Engineered (LVL) laminated frame (150 x 51 mm), 50mm architraves (12mm thick) on both sides, 45x15mm stops, and factory recesses for hinges and locks. Hardware paid separately. Solid Core doors in Laminate finish Size- 1000 X 2400mm Single Leaf sliding door without Vision panel sqm 185.51 Included 0.00 0 0
40 11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 18 Standard Door Closer: Providing and fixing Dormakaba TS 68 EN 2-4 surface-mounted rack and pinion door closer for standard internal doors. sqm 47.46 Included 0.00 0 0
41 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm 18 SS Ball Bearing Hinges: Providing and fixing SS 304 grade ball bearing butt hinges (Size: 102 x 76 x 3mm). sqm 163.01 Included 0.00 0 0
42 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete: Size of Tile 600x600 mm 18 Mortise Sash Lock Case: Providing and fixing heavy-duty mortise sash lock case for latch and deadbolt operation. sqm 23.39 Included 0.00 0 0
43 12.21.1 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 18 Euro Profile Cylinder: Providing and fixing brass Euro profile pin cylinder. metre 208.53 Included 0.00 0 0
44 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 18 Lever Handle Set: Providing and fixing SS 304 grade return-to-door (D-shape) lever handles on rose with escutcheons. each 8.00 Included 0.00 0 0
45 12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter 18 Concealed Flush Bolts: Providing and fixing lever-action concealed flush bolts for the inactive leaf of double doors. metre 25.20 Included 0.00 0 0
46 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm bend 18 Floor Mounted Door Stops: Providing and fixing Dormakaba SS 304 floor-mounted dome door stops with rubber buffers. each 10.00 Included 0.00 0 0
47 12.42.6.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm Shoe 18 Providing and fixing self-supporting Restroom Cubicles of standard dimensions (approximate size: 1000mm Width x 1500mm Depth x 2000mm Overall Height, including a minimum 600mm wide door and 100mm to 150mm floor clearance) made of 12mm thick Compact Laminate. The laminate shall be manufactured using urea-free, thermosetting phenolic resin-treated Kraft papers as the core material, and amino plastic resin-treated decor papers on the finished surfaces. Material Certifications: The board must conform to IS: 2046-1995, EN 438:2016, and NEMA LD3-2005 quality standards. It must possess Anti-virus (ISO 21702:2019), Anti-bacterial (JIS Z2801:2010), and Anti-fungal (ASTM G21-2015) properties, and meet the indoor air quality certification for Greenguard Gold standards. Hardware & Accessories: The work includes providing and fixing all necessary hardware as per manufacturer's specifications and Architect's instructions. Fasteners shall be SS-316 grade. The hardware package shall include: Hinges: SS-316 grade spring-loaded hinges in a black powder-coated finish with antique gold lacquered hinge covers. Locks: Zinc die-casted slide bolt with occupancy indicator in an anodized metallic antique gold over charcoal black finish. Coat Hook: Zinc die-casted body in anodized antique gold finish with fine spark texture on PVC buffer parts. Profiles: Aluminium U & F-profiles with snap-fit screw covers made from Aluminium alloy grade 6063-T6, anodized in charcoal black matte finish. Legs: Zinc die-casted adjustable foot (mid-panel mounted or divider setback leg) in a dual-color finish of charcoal black and antique gold, anchored to the floor providing a ground clearance of 100mm to 150mm. Top Rail: Box-shaped extrusion top rail with end caps, made of Aluminium alloy grade 6063-T6 in charcoal black matte anodized finish, fixed to pilasters with SS-316 screws. Accessories: Rubber noise-deafening tape for doors, and all necessary SS-316 screws and heavy-duty wall plugs. All work to be perfectly plumb, level, and complete in all respects as per the drawings and the direction of the Engineer-in-Charge. each 10.00 Included 0.00 0 0
48 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 18 Providing and fixing Urinal Modesty Panels (Divider Panels) made of 12mm thick Compact Laminate (HPL) in a standard single plain color. Dimensions & Tolerances: The panel size shall be 500mm (Width) x 900mm (Height). The panel shall be wall-mounted with a bottom clearance of 650mm from the finished floor level, achieving an overall height of 1550mm. The laminate board must strictly adhere to a maximum warpage criteria of 3.0 mm per 1000mm as per EN-438 standards. Hardware & Accessories: The panel shall be fixed securely to the wall using standard SS-304 grade accessories. The hardware package includes: SS-304 grade Right Angle Brackets / U-channels. SS-304 grade fully threaded screws. Heavy-duty PVC wall plugs. All work shall be executed perfectly plumb, level, and complete in all respects as per manufacturer guidelines, Architect's drawings, and the direction of the Engineer-in-Charge. each 20.00 Included 0.00 0 0
49 13.1.2 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 18 Providing and fixing 12mm thick clear frameless toughened glass door with machine-polished edges, complete with a peripheral frame/jamb made of 1.5mm thick SS 304 grade sheet in brushed/satin finish, securely anchored to masonry/concrete with heavy-duty fasteners and sealed with structural silicone. The work includes supplying and installing all necessary SS 304 grade hardware, including a heavy-duty concealed double-action floor spring, top and bottom patch fittings, top pivot, patch center lock with key cylinder, and 600mm long SS 304 back-to-back pull handles. The rate is inclusive of all materials, hardware, EPDM gaskets, skilled labor, scaffolding, and transportation to complete the installation in perfect line, plumb, and level. Measurement shall be in Square Meters (Sqm), taken clear from jamb to jamb and floor to top jamb. sqm 545.39 Included 0.00 0 0
50 13.2.2 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) 18 Torsion Spring, Aluminium, Custom Perforated, Powder Coated tile Ceiling System (Wooden finish): Providing and Fixing of torsion spring Plank Ceiling System comprising of Tile of 600mm wide and 1200mm long manufactured out of 0.90 mm thick Aluminium Alloy 3105. The planks shall be perforated perforated 2.5mm dia 5.5mm c/c with 16% open area.The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel . The Tile will be manufactured on advanced CAD/CAM equipment that includes several levelling stages in the manufacturing process. Torsion Spring panel with two side legs die formed and two end legs die formed and punched to receive torsion springs (min two springs each end or side) for secure engagement into Tee Grid main runners which are factory punched to receive torsion springs. Tiles will be square edged. The metal ceiling panels shall be downward accessible with a minimum of four (4) torsion springs per panel. The Tile shall be Polyester powder coated in white colour. Main Runners: 24mm deep, inverted “Tee” sections, 3.6m long, with factory punched flanges to receive torsion spring assembly. Main Tee on center spacing to match panel length. Cross Runners: 24 mm deep, inverted “Tee” sections designed to interlock in to web of main tee section on designated spacing. Cross tee length to match panel length. Cross tees are spaced spacing 1200mm on center maximum. Suspension System: As per manufacturer standard considering type of plenum and its height. Paint finish: The panels will be pre treated in latest nano technology process and electro statically powder coated with automatic Carona system and cured with gas catalytic technology. Acoustic Felt: Non-woven felt made of glass-reinforced fibre glued over the perforation for sound absorption - NRC- 0.7. The ceiling system should meet the required standards for GreenPro certification and should qualify as green product as per CII green products and services council. The manufacturer should be ISO 9001: 2015 Quality Management System Certification compliant. sqm 822.36 Included 0.00 0 0
51 13.16.1 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 18 Providing and fixing U Baffle Aluminium plain panel (Non-perforated) ceiling of approved colour consisting of panel size 100 mm deep X 50 mm width using 0.60 mm thick, panel length upto 6.0 mtr. The Baffle shall be rollformed. Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3105 (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be clipped to a baked enamelled Aluminium carrier of 30 mm wide x 47 mm high x 0.5 mm thick, Black Colour coated, one leg of the carriers with cut outs to hold the panels in a module of 150 mm. Panel carrier shall be suspended by means of threaded rod at a distance of 1.20 mtr c/c. Paint Finish: Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, Exposed side with a full primer and finish coat on a Continuous Paint Line. Ceiling Finish above U Baffle Ceiling : Ceiling area above U Baffle to be painted in black colour before fixing this system QUALITY : All Products to be Green Pro & Siesmic Certified Products. sqm 313.56 Included 0.00 0 0
52 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 18 Providing and fixing vertical linear baffle ceiling made out of Galvanized Mild Steel in 0.6mm thickness. The baffle units shall be in size of [Customized Different Heights] 120(H) x 30mm(W) x Customized(L). The ceiling baffle units shall be installed at the distance of 130mm from c.c. All Baffle to be provided with end cap matching the similar finish of baffle and connected to one another with longitudinal splice connectors. The baf-fle units should be attached perpendicularly to C-channel carriers of size 30 x 30 mm x 1.2mm thick at 1200mm cen-tres as per the requirement of DIN EN 13964, and sus-pended with M6 threaded rod hangers spaced 1200mm c.c. Tolerances according to TAIM,DIN EN 13964 & Quality controlled to ISO 9001:2008. Finish: Wooden finish film having Flame resistant, non toxic and VOC free properties. sqm 728.82 Included 0.00 0 0
53 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 18 Providing and fixing Triangular Hook On metal Ceiling system manufactured out of 0.7mm Thk Galvanized Mild Steel. The metal panels are suspended form-fitting and tension-free by means of a special sub structure. Panels to be cus-tom made perforated to 20x20x20mm Triangular CNC Punched Pattern @ 34.7mm Centres having sound absorp-tion of minimum. 0.5 with use of special acoustic tissue pasted at the back of panels. Panels to come in sizes 1000x1000x1000mm ( Can vary as per requirement).Panels to be powder coating win selected Non Metallic RAL finish with Coating thickness of appx 70-80 µm. Demounting is performed without tools. Tolerances and quality require-ments according to TAIM, DIN EN 13964 and durlum. Deliv-ery and installation of a System S4/5 substructure consist-ing of U 1040 form punched angles as a lateral grid which is suspended pressure-rigid from the bare ceiling with threaded rods using official approved dowel plugs. The an-gles are to be connected together at the ends by means of U 1041 longitudinal connectors. The spacing of the grid an-gles is according to the requirements of DIN 18168 and DIN EN 13964 as well as the loads of the system and are to be determined and checked by the contractor. On the grid an-gles, U 1005 A Z-shaped carrier profiles 1.50mm Galvanized steel are attached as longitudinal profile with M6 bolts [se-cured against loosening]. The longitudinal connection of the Z-shaped carrier profiles are made by means of U 401 pro-file connectors. The spacing of the Z-shaped carries profiles is to be matched exactly to the spacing of the hook-in sides of the metal panels so that panels rest tension-free in the system. Care is to be taken to ensure horizontal and flush alignment. It is only permissible to use structure compo-nents that have been approved by the manufacturer of the metal panels. All parts are made of galvanised steel. Sub-structure: Proprietary hook on substructure, M6 Threaded rods/fasteners, other fixing accessories included. The maxi-mum suspension allowed is upto 2.0 mtr. No additional framing, bridging, lateral supports considered in the quoted prices. The system should be in accordance with Material class A2-s1, d0 according to EN 13501-01 “non-combus-tible”, as per the Direction of Arch-in-charge. The system will meet fire retardant standards of BS 476: Part 6 & Part 7. Tolerances according to TAIM, DIN EN 13964 and quality controlled to ISO 9001:2015, LEED certification by IGBC. Manufacturer shall have the fully automatic powder coating system with power and free conveyorize 3mtr/minute capacity. Powder coating plant shall be equipped with latest modern technology with fully auto-matic inline Pre-treatment using nano technology, Inline automatic water Drying system after pretreatment. Per bag of 50kg cement used in the mix 208.10 Included 0.00 0 0
54 13.41.1 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 18 Providing and fixing metal lay in ceiling where the panel is laid form-fitting & tension free on a T 15 visible grid profiles to ensure easy demounting without tools. The ceiling planks shall be in size of 600x600x0.70mm (thk) base Aluminium sheets. Panels shall be Tegular edged with 8mm vertical drop for pleasing aesthetics with 20% perforation area with 2.5 mm dia holes and having 0.5 NRC. The metal panels to be laid in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections consisting of Main "Tee", size 15W x 32H x 3600L mm made from 0.30 mm thick sheet spaced at 1200mm centre to centre and Cross "Tee", size 15W x 32H x 1200L mm made of 0.30 mm thick sheet to be interlocked between the main T run ners at the distance of 600mm centre to centre to create 1200x600mm mod ule. Main "Tees" to be suspended from ceiling using GI slotted cleats fixed to ceiling with anchor fasteners, 4mm GI adjustable rods with galvanized level clips spaced at 1200mm centre to centre along the Main Tee. The first suspension from the perimeter trim should not exceed 300mm. The tiles shall be cleaned through eco-friendly cleaning process. Tolerance & quality require ments according to TAIM,DIN EN 13964. For LEED: Certified by IGBC. sqm 1681.31 Included 0.00 0 0
55 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 18 Linear Aluminium Un-perforated Multiple Width 80,130,180 Ceiling System with 20 mm open groove: Providing and fixing Linear Ceiling of 80B,130B,180B un-perforated Aluminium panel ceiling of approved colour consisting of panel 80mm wide / 130mm wide/ 180mm wide x 15mm deep x 0.5mm thick with square edges, panel length up to 6 mtrs, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3105 (Al. Mg) for higher strength and good roll forming characteristics. Panel shall be clipped to a baked enamelled Aluminium panel carrier of 62mm wide x 29mm deep made of 0.95mm thick in standard length of 5mtrs made of double baked enamelled Aluminium alloy AA 3005 (Al. Mg.) black with cut outs to hold the panels in a module of 150mm (width of gap 20mm open) and at a distance 1.55mtrs without insulation and 1.35mtrs with insulation. The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter and a Galvanised suspension spring clip at a distance of 1.7mtrs c/c. Paint finish: Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, one side with full primer and finish coat, the other side (inner side) with a Primer Coating and Skin Coat on a Continuous Paint Line. Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. The Manufacturer should have high precision High Speed Cold Roll Forming Machines with a experience of 10yrs. Product should be able to comply Greenbuilding certification IGBC Green Pro Certificate, Siesmic Zone V Certification & ISO 9001-2015. Fire Rating to comply for BS 476 Part 6 & 7. sqm 914.87 Included 0.00 0 0
56 13.62.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 18 CLOSED PERFORATED METAL CEILING SYSTEM WITH ACOUSTIC MESH: Providing and fixing Luxalon 300 closed Perforated 2.0 mm diameter 5mm centre to centre with Non Woven textile Aluminum False ceiling of approved colour consisting of panel 300 mm wide x 30 mm deep x 0.7 mm thick with bevel edge having panel length up to 6 mtrs coil coated on continuous paint line, double baked and roll formed for higher strength and good roll forming characteristics. The panel ends will be raised up to 29 mm. The panels abut each other with a narrow ‘V’ groove. Panel shall be clipped to a baked enameled aluminum carrier of 41.5 mm wide x 62 mm deep x 0.95 mm thick in standard length of 5 mtrs, made of double of 300 mm closed at distance 2.00 mtrs. Panel carrier suspended by means of 6 mm thick galvanized threaded Rod complete as per specification drawings and as directed by Engineering-in-charge. Paint Finish:Aluminium panels shall be chromatised for maximum bond between metal and paint enamel twice under high temperature, one side with a full primer and finish coat, the other side (inner side) with a primer coating and skin coat on a continuous paint line. PANEL: Panels shall be cold rolled formed panels of 300 mm wide, 30 mm deep and 0.7 mm thick with a 5 mm beveled edge creating a 10 mm ‘V’ groove made from corrosion resistant AI-Mg Alloy AA3105’. The maximum length of each panel shall be 6000 mm. The panels are recyclable, lightweight and strong. Panels are perforated 2 mm diameter & 5 mm C/C giving 15% openness. The panels shall have non woven textile acoustic tissue glued over whole perforated area. CARRIER: The carrier on which the panels shall be clipped on to will be 41.5 mm wide and 62 mm deep made of black stove enameled 0.95 mm thick Aluminium Alloy with length of 5 mtr. The Manufacturer should have high precision High Speed Cold Roll Forming Machines with a experience of 10yrs. Product should be able to comply Greenbuilding certification IGBC Green Pro Certificate, Siesmic Zone V Certification & ISO 9001-2015. Fire Rating to comply for BS 476 Part 6 & 7. sqm 43.24 Included 0.00 0 0
57 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 18 DSR 12.45.3 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with taperedflanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :.Gypsum False Ceiling 12.5 mm thick tapered edge gypsum moisture resistant board : sqm 2410.13 Included 0.00 0 0
58 17.1.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 18 Providing and making suspended plain Gypsum board cove ceiling with lighting profile having a minimum horizontal span of 300-600 mm, a vertical fascia drop of minimum 150 mm, and an internal upstand lip of 50 mm to create a concealed lighting niche. The framework shall comprise of standard galvanized iron (GI) sections including perimeter channels (20x27x30x0.55mm), intermediate channels (15x45x15x0.9mm) suspended from the soffit using GI ceiling angle (25x10x0.55mm) and cleat/rawl plugs at a maximum spacing of 1200 mm center-to-center. The framework shall be securely braced for rigidity. The frame is to be boarded with 12.5 mm thick plain Gypsum board conforming to IS: 2095 (Part I) fixed using 25 mm long drywall corrosion-resistant screws at 230 mm intervals. The boards are to be fixed flush, and all joints, screw dimples, and corners are to be finished seamless and smooth using jointing compound and fiber tape. The rate includes the cost of all materials, labor, scaffolding, leads and lifts up to all floor levels, excluding the cost of painting and electrical fixtures. complete to the satisfaction of the ArchitectQuoted rates to include General Notes and all the above points as required and approved by Architect each 3.00 Included 0.00 0 0
59 17.3.1 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 18 Providing & Fixing False Ceiling Extruded Aluminum Perimeter Trim 100mm Trim Channel : 100mm wide face with 19.3mm(+/-0.50mm) horizontal legs, straight & factory finished curved sections with special bosses formed for attachment to the trim tee-bar connection clip or hanging clip, extruded Aluminum, factory finished (minimum 50 microns factory - applied baked polyester paint).Aluminum Extrusions formed with distinct architectural detail groove on top and bottom flanges and special bosses to receive the tee bar connection clips and splice plates, to provide positive mechanical lock with no visible fasteners. Splice Plate: Formed to fit into special bosses in the trim and locked in place with factory-installed screws. These Steel splice plates are used to align and secure all joints between sections of trims. Each joint in the 50mm section height/ Knife Edge will require one splice plate whereas 100 mm & 150mm trims will require 2 splice plate at each joint. Corners are to be formed by mitering the end of trim and splice plate to be bent at right angle for connecting the end pieces. Tee-Bar Connection Clip: Commercial quality G.I formed to fit into special bosses and locked in place by factory-installed screws and attached to the suspension system members. T-Bar connection clips are used to attach the trim to the supporting Suspension system members. These two-piece Aluminum clips are supplied as an assembled unit with the steel locking screw factory installed. One clip is required at each location where the grid system intersects the trim. Hanging Grid clips:Classic trims to be hung independently to the structural soffit by engaging the Hanging Grid Clip into the bosses of the trim channel and securing it to structural soffit using aircraft cables/GI wire. Installation Procedure: "1. Hang the sections of trim onto the grid system by engaging the top ear of the connection clip under the boss of the channel trim. Slide the lower leg downward to engage the lower boss on the trim and secure by tightening the locking screw" "2. Complete the installation of all channel trims sections. Install and secure the splice plates, corner pieces, alignment plates etc." "3. Make adjustments as necessary to properly align the complete installation. " each 4.00 Included 0.00 0 0
60 17.10.1.4 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 178 mm 18 Providing & Fixing Stonewool acoustic ceiling system consisting of factory-finished stone wool tiles of dimensions 600×600 mm / 1200×600 mm and thickness of 12 mm, having an approximate weight of 1.6 – 1.9 kg/m², conforming to EN 13964 performance standards. The tile shall have Class B sound absorption with αw = 0.80 (NRC 0.80) and Reaction to Fire classification A1, suitable for commercial interiors. The panel shall have humidity resistance up to 100% RH with no visible deflection in high-moisture environments, and shall be cleanable by vacuum for routine maintenance. Installation shall be carried out using Silenzo+ exposed T-Grid suspension system comprising Main Tee (24 mm or 15 mm) and Cross Tee members, manufactured from hot-dip galvanised steel, suspended using GI wire hangers fixed to the structural ceiling at recommended intervals. Perimeter wall angles 24×24 mm shall be installed to receive tile edges, and hold-down clips shall be provided where required to ensure stability and system alignment. The completed ceiling shall provide a durable and acoustically effective surface suitable for offices, retail and commercial spaces. each 3.00 Included 0.00 0 0
61 17.28.2.1 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia 18 Supply and Installation of linear hook-on ceiling System. The non perforated panels are made to 2300(L)x300(W) manufactured out of minimum 0.7mm thick GMS and hooked on the shorter side. Finish of the panels to be powder coated dur graphic digitally printed UV cured wood-grain finish with minimum 60 microns base coating. All panels are hooked onto a secondary grid known as U1005 installed at shorter side of the panel to ensure individual demounting of panels for easy accessibility of services. A pri-mary grid of perforated L- Angle in 30x30x1.2mm thick galvanized steel known as U1040 is installed perpendicularly to hook on profiles at maximum centres at 1200mm. The entire ceiling shall be suspended with M6 threaded rod using Hilti M6 fastener with mini-mum load of at least 0.5kn per anchor. The sus-pension system shall be as per manufacturer specification. The panels shall include the site cutting / making openings for services e.g. lights for information boards, smoke detectors, speakers, diffusers, grills etc. Measurement to be done on edge-to-edge basis without any de-ductions for AC grills or any other services inte-grated within the false ceilings. Tolerances ac-cording to TAIM, DIN EN 13964 and quality con-trolled to ISO 9001:2015 approved by SIS, LEED certification by IGBC. Manufacturer shall have the fully automatic powder coating system with power and free conveyorize 3mtr/minute ca-pacity. Powder coating plant shall be equipped with latest modern technology with fully auto-matic inline pre-treatment using nano technol-ogy, Inline automatic water Drying system after pretreatment. each 13.00 Included 0.00 0 0
62 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 18 Supply and Installation of straight & curve metal wall cladding panels with flexible system ensuring individually demountable wall elements suitable for in-stalling horizontally 500mm wide panels up to 1300mm length manufactured of 1mm thick GMS with minimum 60micron powder coating. The panels shall be non-perforated surfaces as per the design requirement. Substructure con-sisting of SW02 C Channel profile 50x50x1.20mm GMS, installed vertically to which the wall panels are inserted in a positive-locking and tension-free manner along with the Fixing Bracket SW01 57X54X57X70mm which are fastened to the load-bearing frame/wall us-ing officially approved fastening equipment that has been selected in accordance with the local project specific requirements and fas-tened professionally. The distances of the SW02 C channels and the SW01 wall bracket used as load-bearing profiles for the wall panels have to be defined according to the installation manual and must be proven and established by the contractor. It must be ensured that the dis-tances of the profiles are exactly designed re-garding the module width of the wall panels so that the wall panels can be suspended in a pos-itive-locking and tension-free way. Ensure hori-zontal and flush alignment during the installa-tion of the profiles. Only construction parts may be used that have been approved by the manu-facturer of the wall claddings. All load-bearing parts must be made of galvanised steel sheet. For finishes, ASTM B117, Salt Spray (fog) test 500 hours on powder coated galvanized steel sheet, ISO 2409, paint and vanishes, crosscut test on powder coated galvanized steel sheet. Tolerances according to TAIM, DIN EN 13964 and quality controlled to ISO 9001:2015 ap-proved by SIS.Any additional framing, bridging, lateral supports, back support substructure (if required) shall be in the Main contractor scope. Finish: Digital Printed woodgrain. Manufacturer shall have the fully automatic powder coating system with power and free conveyorize 3mtr/minute capacity. Powder coating plant shall be equipped with latest modern technology with fully automatic inline pre-treatment using nano technology, Inline automatic water Drying system after pretreat-ment. each 8.00 Included 0.00 0 0
63 17.33 Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 18 Applying priming coats with acrylic primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre each 8.00 Included 0.00 0 0
64 17.35.1.2 Providing and fixing soil, waste and vent pipes : 100 mm dia: Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 18 Providing and applying a full-surface skim coat (approx. 1mm thick) of premium ready-mixed acrylic wall putty over pre-jointed gypsum board false ceilings and wall partitions to equalize surface texture and porosity. The work includes progressive sanding using fine-grit emery paper to achieve a flawless, monolithic, pinhole-free surface ready to receive primer and paint. The rate is inclusive of acrylic putty, sandpaper, scaffolding, and all skilled labor required for application and finishing. Rmt 74.40 Included 0.00 0 0
65 17.35.2.2 Providing and fixing soil, waste and vent pipes : 75 mm dia: Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 18 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats Rmt 66.75 Included 0.00 0 0
66 17.37.1 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe 18 Lustre Paint Providing and applying two or more coats of premium interior water-based lustre paint to give an even shade and uniform sheen on prepared and primed wall/ceiling surface. The paint shall be applied using a recommended roller (sponge or felt as per manufacturer guidelines) to achieve the desired texture (smooth or granular) without visible lap marks or patches. The rate is inclusive of the lustre paint, rollers, masking tape, surface protection, scaffolding, and all skilled labor required for the application. Measurement shall be in Square Meters (Sqm) of the actual painted ceiling/wall area. Quoted rates to include General Notes and all the above points as required and approved by Architect each 20.00 Included 0.00 0 0
67 17.37.2 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 75 mm dia pipe 18 Repro Counter with Storage finished in Laminate(750mm widht x 1050mm height) Providing and Fixing Shutters below Counter constructed of 19mm thk. comm ply. Hinged shutters with self and soft close hinges of approved make. All the external and Internal surfaces shall be finished with approved Laminate and 1.5mm thk Edge binding on all the edges Division of the shutters shall be made equally according to the length of the storage. All internal surfaces shall be finished with 1mm thk. laminate including the shutters and 2mm thk Edge binding on all the edges. Rate shall be inclusive of all necessary fittings like hinges, self and soft closing, locks, ball catches, profile handles of approved make and design and miscellaneous hardware items. each 20.00 Included 0.00 0 0
68 17.38.1.2 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.: 100 mm dia: Sand cast iron S&S as per IS - 3989 18 Repro Counter with Storage below and counter above finished in Laminate Providing and Fixing Reprographics counter with Planter box above & Storage below of size as mentioned in the drawing in approved finish. Storage of size 750mm (h) x 600 mm (d) Counter Top shall be 750mm deep and shall be in 18 mm thk commercial ply, with sides and bottom in 18 mm thk commercial ply. All exposed surfaces shall be finished in 1 mm thk laminate of approved shade / make. 1.5mm thk Edge band shall be provided to the edge of the top and supports. Shelves fitted on metal buttons in 18 mm thk commercial ply finished on top and bottom with 1 mm thk laminate of approved shade/ make as shown in the drawing. Planter box above repro is fabricating a frame out of MS box section to form a frame structure of size 2400mm (l)x 2700mm (h) x 450 mm (d). MS section positioned vertically at c/c distance of 1000mm & horizontally at 600mm. Metal frame to be powder coated to approved colour. The frame to have trays made of 12mm thk. Marine ply and finished with approved Laminate to hold the Planter boxes. Rate shall be inclusive of all necessary hardware items required as per design and drawing, etc. complete to the satisfaction of the Architect. each 7.00 Included 0.00 0 0
69 17.38.2.2 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.: 75 mm dia: Sand cast iron S&S as per IS - 3989 18 Pantry/Serving Counter 750mm Wide in Acrylic Solid Surface (850mm (h) x 750 mm (d)) Front fascia of approx. 50mm thickness & 200mm high back splash finished in Acrylic Solid surface, finished as per Architects Detail/Drawing. Joints to be bonded with only "joint Adhesive for approved solid surface "- as specified by Solid Acrylic Surface Manufacturer. each 10.00 Included 0.00 0 0
70 17.39.1.2 Providing and fixing plain bend of required degree.:100 mm dia: Sand cast iron S&S as per IS : 3989 18 Storages Providing and Fixing storages of size as mentioned in the drawing. Top of the unit shall be in 18 mm thk commercial ply, with sides and bottom in 18 mm thk commercial ply and back in 6mm thk. commercial ply. Shutters shall be in 19 mm thk green block board. All exposed surfaces including shelves shall be finished in 1mm thk laminate of approved shade / make as shown in the 3Dimage/ specified in the drawings. All exposed edges shall be finished in 2 mm thk edge binding of approved shade/ make and all inner surfaces including shutter back shall be finished in 0.8mm thk laminate of approved shade and make. Shelves to be fitted on metal buttons in 18 mm thk commercial ply. Rate shall be inclusive of fixing 1mm thick laminate of approved shade/ make as specified, on all exposed surfaces & the storage back where ever exposed. Rate shall be inclusive of all necessary fittings like hinges, locks, magnetic catches, handles of approved make and any miscellanous hardware items required as per design ans drawing, etc. complete as per Architect's instruction, detailed design and drawings. Division of the shutters shall be made equally according to the length of the storage or as specified in the design/ drawing. Quoted rates to include General Notes and all the above points as required and approved by Architect Basic rate 1 mm thk Laminate Rs. 55/- Sft Full ht. storages in Laminate Finish - 600mm depth each 7.00 Included 0.00 0 0
71 17.39.2.2 Providing and fixing plain bend of required degree.:75 mm dia: Sand cast iron S&S as per IS : 3989 18 Storages Providing and Fixing storages of size as mentioned in the drawing. Top of the unit shall be in 18 mm thk commercial ply, with sides and bottom in 18 mm thk commercial ply and back in 6mm thk. commercial ply. Shutters shall be in 19 mm thk green block board. All exposed surfaces including shelves shall be finished in 1mm thk laminate of approved shade / make as shown in the 3Dimage/ specified in the drawings. All exposed edges shall be finished in 2 mm thk edge binding of approved shade/ make and all inner surfaces including shutter back shall be finished in 0.8mm thk laminate of approved shade and make. Shelves to be fitted on metal buttons in 18 mm thk commercial ply. Rate shall be inclusive of fixing 1mm thick laminate of approved shade/ make as specified, on all exposed surfaces & the storage back where ever exposed. Rate shall be inclusive of all necessary fittings like hinges, locks, magnetic catches, handles of approved make and any miscellanous hardware items required as per design ans drawing, etc. complete as per Architect's instruction, detailed design and drawings. Division of the shutters shall be made equally according to the length of the storage or as specified in the design/ drawing. Quoted rates to include General Notes and all the above points as required and approved by Architect Basic rate 1 mm thk Laminate Rs. 55/- Sft Over Head storages in Laminate finish - 400mm depth each 10.00 Included 0.00 0 0
72 17.43.1.2 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.: 100x100x100 mm: Sand cast iron S&S as per IS - 3989 18 Storages Providing and Fixing storages of size as mentioned in the drawing. Top of the unit shall be in 18 mm thk commercial ply, with sides and bottom in 18 mm thk commercial ply and back in 6mm thk. commercial ply. Shutters shall be in 19 mm thk green block board. All exposed surfaces including shelves shall be finished in 1mm thk laminate of approved shade / make as shown in the 3Dimage/ specified in the drawings. All exposed edges shall be finished in 2 mm thk edge binding of approved shade/ make and all inner surfaces including shutter back shall be finished in 0.8mm thk laminate of approved shade and make. Shelves to be fitted on metal buttons in 18 mm thk commercial ply. Rate shall be inclusive of fixing 1mm thick laminate of approved shade/ make as specified, on all exposed surfaces & the storage back where ever exposed. Rate shall be inclusive of all necessary fittings like hinges, locks, magnetic catches, handles of approved make and any miscellanous hardware items required as per design ans drawing, etc. complete as per Architect's instruction, detailed design and drawings. Division of the shutters shall be made equally according to the length of the storage or as specified in the design/ drawing. Quoted rates to include General Notes and all the above points as required and approved by Architect Basic rate 1 mm thk Laminate Rs. 55/- Sft Water Dispensor Console in Duco finish - Size : 600mm(L) X 2400mm(H) X 600mm (D) each 18.00 Included 0.00 0 0
73 17.43.2.2 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.: 75x75x75 mm: Sand cast iron S&S as per IS - 3989 18 PelmetProviding & fixing pelmet of size 300mm deep X 150mm height for roller blinds in 19mm thk. ply finished with approved 1mm laminate internally as per Architect instructions. Block board to be anchored to the structural beam. Fixing detail may vary as per site conditions. Note ply support to be considered till main slab wherever pelmet happens in exposed ceiling area. Rate to be inclusive of the same, etc.complete as per Architect's instruction, detailed design and drawings each 12.00 Included 0.00 0 0
74 17.56.1.2 Providing and fixing terminal guard :100 mm: Sand cast iron S&S as per IS - 3989 18 Step For Raised Flooring - 300m wide Providing and Fixing of steps for raised flooring in 19 mm thick Ply finished in laminate etc. complete as per Architect's instruction, detailed design and drawings. each 9.00 Included 0.00 0 0
75 17.56.2.2 Providing and fixing terminal guard :75 mm: Sand cast iron S&S as per IS - 3989 18 "FRP Planter Box with live Plants Providing and placing custom-made Fiber Reinforced Plastic (FRP) planter boxes of specified dimensions. The rate is inclusive of: • Minimum 4mm to 6mm FRP wall thickness with adequate structural stiffeners to prevent bulging. • Premium PU (Polyurethane) paint finish in matt/gloss as per architect's approval. • Internal waterproofing and necessary drainage holes. • Anti-root geotextile membrane. • Prepared potting mixture (garden soil, coco peat, and organic manure/vermicompost). • Supply and plantation of healthy, well-rooted live indoor/semi-shade plants as per the approved layout." Size - 550 mm X 500mm X 450mm each 6.00 Included 0.00 0 0
76 17.57.1.2 Providing and fixing collar : 100 mm:Sand cast iron S&S as per IS - 3989 18 "FRP Planter Box with live Plants Providing and placing custom-made Fiber Reinforced Plastic (FRP) planter boxes of specified dimensions. The rate is inclusive of: • Minimum 4mm to 6mm FRP wall thickness with adequate structural stiffeners to prevent bulging. • Premium PU (Polyurethane) paint finish in matt/gloss as per architect's approval. • Internal waterproofing and necessary drainage holes. • Anti-root geotextile membrane. • Prepared potting mixture (garden soil, coco peat, and organic manure/vermicompost). • Supply and plantation of healthy, well-rooted live indoor/semi-shade plants as per the approved layout." Size - 950 mm X 750 mm X 450mm each 4.00 Included 0.00 0 0
77 17.57.2.2 Providing and fixing collar : 75 mm:Sand cast iron S&S as per IS - 3989 18 "FRP Planter Box with live Plants Providing and placing custom-made Fiber Reinforced Plastic (FRP) planter boxes of specified dimensions. The rate is inclusive of: • Minimum 4mm to 6mm FRP wall thickness with adequate structural stiffeners to prevent bulging. • Premium PU (Polyurethane) paint finish in matt/gloss as per architect's approval. • Internal waterproofing and necessary drainage holes. • Anti-root geotextile membrane. • Prepared potting mixture (garden soil, coco peat, and organic manure/vermicompost). • Supply and plantation of healthy, well-rooted live indoor/semi-shade plants as per the approved layout." Size - 1300 mm X 500 mm X 450mm each 4.00 Included 0.00 0 0
78 17.58.1 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm 18 Trophy Shelf with Storage in Duco Finish - 2400mm Ht. Providing and fixing a custom-designed Trophy Shelf with Storage measuring an overall height of 2400mm, with the width and depth as per the approved site layouts and shop drawings. The primary framework and carcass of the unit shall be constructed using 18mm thick, premium-grade Boiling Water Proof (BWP) blockboard or High-Density High Moisture Resistance (HDHMR) board to ensure structural rigidity and prevent warping over time. The backing of the unit shall be finished with 12mm thick matching MDF board securely fastened to the wall to provide absolute stability. To achieve a flawless base for the external finish, all exposed outer surfaces of the plywood framework shall be cladded with a 6mm thick MDF layer, with all exposed edges smoothly finished using a router and edge-binding techniques prior to painting. The functional configuration of the unit shall be divided into two primary sections: a lower concealed storage cabinet and an upper display area. The lower storage section, measuring approximately 750mm to 900mm in height and up to 450mm in depth, shall feature flush-operable shutters constructed from 18mm HDHMR board. The interior carcass of this lower storage, as well as all unexposed internal surfaces, shall be finished with a 1.0mm thick premium suede-finish decorative laminate of an approved shade. The upper section, dedicated to trophy display, shall extend to the full 2400mm height with a slightly recessed depth (approximately 300mm to 350mm) to create a lighter visual profile. This display area shall feature a combination of 18mm thick wooden shelves and 8mm thick clear toughened glass shelves, edge-polished and resting on heavy-duty concealed glass supports or D-brackets, allowing for optimal light transmission. The exterior surfaces of the entire unit—including the outer framework, lower shutter fascias, and upper wooden display shelves—shall be finished in a premium Duco (polyurethane automotive) paint system. The finishing process must include thorough surface preparation, application of a wood primer, two coats of automotive-grade polyester putty, rigorous sanding to achieve a perfectly leveled surface, and the application of a high-build surfacer. This shall be followed by a minimum of three coats of premium Duco topcoat in a matte, satin, or high-gloss finish as approved by the architect or client. The final surface must be machine-buffed to ensure a seamless, pinhole-free, and luxurious architectural finish. All hardware, fittings, and lighting used in the assembly shall be of premium quality. The lower storage doors shall be equipped with concealed 3D-adjustable, soft-close hinges and integrated sleek aluminum profile handles or magnetic push-to-open mechanisms for a seamless look. The upper display section shall include integrated architectural lighting, specifically 8mm recessed aluminum profile channels housing high-density, dotless LED strip lights (CRI > 90, 3000K/4000K as specified). The lighting system shall be complete with concealed drivers, seamless acrylic diffusers, and neat internal wiring routed invisibly through the structural framework. The quoted rate must include all materials, labor, hardware, painting, transportation, scaffolding, and meticulous site installation to line and level. each 64.00 Included 0.00 0 0
79 17.58.2 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :75 mm 18 11.52.1 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. each 75.00 Included 0.00 0 0
80 17.60.2.1 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 18 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick imported Marble stone slab, Malta Pietra Grey, Grey Italian marble, Italian Grey Dayna Marble etc. each 19.00 Included 0.00 0 0
81 18.10.2 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall:20 mm nominal bore 18 Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Providing and applying a premium transparent penetrating stone sealer and polishing coat over newly laid and mirror-polished Italian marble flooring to provide water and oil repellency. The work includes thoroughly cleaning and drying the polished marble surface to ensure it is completely free of dust, moisture, and chemical residues. The sealer shall be applied uniformly in one saturating coat (or two wet-on-wet coats as required by porosity) using a lint-free microfiber cloth or specialized applicator pad, ensuring full penetration. Excess surface sealer must be buffed off completely within the manufacturer's specified open time to prevent hazy residue. The rate is inclusive of the sealer liquid, cleaning consumables, microfiber applicators, masking of adjacent surfaces, and all skilled labor. Rmt 122.67 Included 0.00 0 0
82 18.11.1 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :15 mm nominal bore 18 DSR 8.11.1 Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc. Rmt 168.25 Included 0.00 0 0
83 18.11.2 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :20 mm nominal bore 18 Providing and placing premium quality, custom-sized hand-tufted wool or wool-viscose blend finished area rug for high-end executive office usage. The rug shall have a dense pile weight, bound/finished edges (surged or taped as approved), and shall be laid loose directly over the finished hard flooring. The rate is completely inclusive of the finished rug, factory edge binding, protective packaging, transportation to site, unpacking, unrolling, precise placement as per the Architect's/Interior Designer's layout, and final vacuuming. Measurement shall be in Square Meters (Sqm) of the actual finished rug area provided. Rmt 6.00 Included 0.00 0 0
84 18.13.1 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete -25 to 40 mm nominal bore 18 LVT Flooring Supply and installation of commercial heterogeneous Luxury vinyl Tiles . The total thickness would be 5 mm and the thickness of the wear layer would be 0.5mm. The product should be multi-layered consisting of a wear layer with PUR coating, PVC layer, fiberglass layer, and solid backing. Natural creation commercial shall conform to group T wear resistance as per EN 660-2, Flammability resistance of ≥0.45 as per ASTM E6848, Slip resistance of R8- R9 as per DIN1130, Residual indentation of ≤ 0.01mm as per ASTMF1914, Color fastness rating of ≥ 6 as per ASTM 105- B02. The product shall exhibit antistatic behavior, resistance to chemicals, and suitability to castor chair. The floor should be smooth, flat, and free from moisture. Design and shade to be as per the architect’s choice, it should be installed by an authorized dealer in India. The subfloor would be levelled using cementitious self levelling compound of 2 -3 mm thickness. LVT Floor Shade and pattern shall be as per 3D image provided by Architect. Basic Rate of LVT Flooring - Rs. 2750/- Per Sqm each 4.00 Included 0.00 0 0
85 18.17.1A Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore 18 Providing & fixing of laminate wooden flooring - Class 32(AC4) conforming to EN13329 standards ,thickness of plank minimum 8mm, size of plank- 1291mmx193mm,HDF core board to be swell stop plus with minimum density of 930 kg/m3 according to and conforming to EN622 type 5 standard. Product to be PEFC, FSC & Blue Angel certifications. Fixing to be done using 2mm PE foam and 0.2mm vapour barrier. Product to offer 20 years Gurantee for Residential/domestic use and 5 years Guarantee for commercial usage according to manufacturers guarantee document . Installation shold be done with authorised vendor. Equivalent to Floor Master.. Basic Rate of wooden Flooring - Rs. 1600/- Per Sqm each 20.00 Included 0.00 0 0
86 18.32.1 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1-4 1 cement -4 coarse sand for stop cock, with C. I. surface box 100x100 x75 mm inside with hinged cover fixed in cement concrete slab 1-2-4 mix 1 cement - 2 coarse sand - 4 graded stone aggregate 20 mm nominal size , i OR c necessary excavation, foundation concrete 1-5-10 1 cement - 5 fine sand - 10 graded stone aggregate 40mm nominal size and inside plastering with cement mortar 1-3 1 cement - 3 coarse sand 12mm thick, finished with a floating coat of neat cement complete as per standard design -With common burnt clay F.P.S. non modular bricks of class designation 7.5 18 Supply and installation of Woven Vinyl tile with integrated acoustic underlay, tile size 500 mm × 500 mm, total thickness 4.7 mm, weight 3.150 kg/m², composition 53% mineral, 9% recycled, 38% primary fossil content, with fibreglass reinforced wear layer and integrated impact noise reduction 19dB recycled PET acoustic underlay (93% recycled). It should be Class 33 (heavy commercial use), EN 1307. Made for intensive use as per EN ISO 4918 (chairs with castors), static charge resistance ≤ 2kV. Reaction to fire as per EN 13501-1 should be Bfl-s1, smoke density as per ASTM E662-15A should be < 450. Important parameters include walking noise as per EN 16205 = 71dB (A) & use in humid areas ‘suitable” as per EN1307. Slip resistance according to EN16165-B must be R 10. The product should be certified with BREEM certification. It should come with a 15-year warranty. It must have the Eurofin Gold certification for indoor air comfort. The product should be PHATHALATE-free. The product should also meet Floorscore and REACH compliance and contribute to U.S.Green Buildings' LEED certification. Flooring to be laid over zero level hard surface (cement sand aggregate screed).Work should be carried out by skilled labour under the supervision of authorised distributors. each 3.00 Included 0.00 0 0
87 18.38.2 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :20 mm diameter pipe 18 Providing and laying an average thickness of up to 2-3 mm self-levelling underlayment(Material strength complying to M-30 or above)system by cleaning all floors and applying polymer-based primer followed by application of self-levelling underlayment, maintaining an average thickness of up to 3mm. It should be equivalent as recommended by the Vinyl sheet flooring manufacturer and installation team on the concrete surface to provide a smooth & homogeneous surface for laying of vinyl sheet flooring, complete to the entire satisfaction of the Engineering Rmt 112.00 Included 0.00 0 0
88 18.18.3 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore. 18 11.41A.1.3 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. "Double charge vitrified tile polished finish of size: Size of Tile 600 x 1200 mm" each 3.00 Included 0.00 0 0
89 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 18 11.41A.3.2 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 1200 mm per Ltr 3000.00 Included 0.00 0 0
90 18.74.2 Providing and fixing unplasticised P.V.C. connection pipe with PTMT nuts collar and bush of approved quality and colour. 15MM nominal bore with 45cm length. 18 Providing and laying large-format glazed vitrified floor tiles of approved shade and pattern conforming to IS 13630 / ISO 13006:2018 with a water absorption average of 0.08%. The tiles shall be of size 1200x2400mm or 1200x1800mm (thickness to be specified by the manufacturer) , in approved surface finishes (Full Polished, High Gloss, Quill, Plume, Engravo, or Gritstone). The tiles are to be laid over a 20 mm thick cement mortar bed in proportion 1:4 (1 cement : 4 coarse sand) and fixed using a high-strength polymer-modified tile adhesive in an average 6 mm thick bed over the prepared surface. The work includes filling joints with matching epoxy grout, curing, cleaning, edge finishing, machine cutting wherever required, and disposal of debris, all complete as per drawing, specifications, and direction of the Engineer-in-Charge. each 19.00 Included 0.00 0 0
91 19.1.2 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter 18 Providing and fixing Vitrified tiles of approved make, design, and shade (600x600 mm or 1200x600 mm) having thickness as specified by the manufacturer, with water absorption less than 0.08% and conforming to IS: 15622. The tiles shall be fixed on walls/floors using High Polymer Modified Tile Adhesive (conforming to IS: 15477 Type 2 or equivalent) applied with a square-notched trowel to achieve an average uniform bed thickness of 3 mm to 5 mm. The work includes providing uniform spacer joints (2 mm to 3 mm) and thoroughly filling and pointing the joints with a specialized 3-part Epoxy Grout of approved make and matching/contrasting shade, including masking tile edges, application, and immediate cleaning with emulsifying pads. The rate is inclusive of all surface preparation, materials, labour, wastage, water charges, scaffolding (if applicable for vertical surfaces), tools, and tackles, complete in all respects as per standard specifications and the direction of the Engineer-in-Charge. Rmt 101.48 Included 0.00 0 0
92 19.2.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe 18 DSR 11.54.1Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. - 300 mm Finished Floor Height (FFH) (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends or securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. (c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. Rmt 101.48 Included 0.00 0 0
93 19.4.3.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 18 DEMOUNTABLE PARTITION DOUBLE GLAZED TOUGHENED GLASS PARTITIONS "Supply and installation of Double glazed mullion free demountable glass partition using Toughened/ Laminated glass in proprietary natural anodised/Black/ Other colors aluminium sections of size 100mm x 30mm with Concealed sealing (No visible Gaskets/Seals) with acoustic rating of upto 45 dB with third party test certificate. The profile will have Carpert Groove at the Bottom on both sides for accomodating max. 8mm carpets.It should consists of intermediate slim junction profiles for Glass to Glass vertical joints, 90 Degree L Junction and T Junction profiles suitably to be used as per room configuration designs.No VISIBLE Clip Lines to provide clutter free view at both side of section. Optional Profile Bottom Seal pair for additional accoustic if required. Glass thickness - 10+12mm Toughened Glass CLT, All Profiles are min 1.5mm thickness excluding 20 microns of Anodizing, Standards applicable •Structural stability test accordance to BS 5234: Part2:1992 & EN 1991-1-1:2002 • Acoustic test for sound insulation in accordance to DIN EN ISO 10140-2 ASTME-E 90 • ALT profile sections are manufactured and tested in accordance to EN573-3, EN755-2, DIN EN 12020 T2 , non-dimensions manufacturing tolerance deviation DIN ISO 2768-1 class C = coarse • Toughened glass complies accordance to BS 6262 (glass supplier specification from market) • Environmental product declaration (EPD) rating accordance to ISO 14025 & EN 15804 Double glazed profile being modular shall have feature of converting existing Double glaze into Single glaze without disturbing Finished areas/ removing existing partition system. Max System Height - 3000mm" Note - Only measurement of fixed glass partiton shall be considered for payment, glass door payment shall be extra as per below each 10.00 Included 0.00 0 0
94 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) 18 Supply & Fixing Single Leaf Double Glazed Aluminium Door with 21mm DGU (6mm toughened glass + 10mm air gap + 5mm toughened Glass) with 100mm frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Door Profile frame with clips & seals with Flush Hinges (3Nos) & Pure 8906 Lever Handle NSL 100 Narrow stile Lock, TS 70 EN 3-4, Door Stop packagenecessary seals to be provided all around the door frames. For doors part of single/double glazed partiton Door rebate profile to be used.In case of Glass overall panel Over Panel Door profile to be used. The profiles shall be suitable for Glass thickness of 10mm.The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. kg 968.00 Included 0.00 0 0
95 21.1.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) 18 Supply & Fixing double Leaf Double Glazed Aluminium Door with 21mm DGU (6mm toughened glass + 10mm air gap + 5mm toughened Glass) with System-100 frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Door Profile frame with clips & seals with dormakaba Flush Hinges (3 Nos) & Pull Handle D type Offset 450x25mm, NDL 100 Narrowstile Dead Lock, TS 70 EN 3-4, Door Stop packagenecessary seals to be provided all around the door frames. For doors part of single/double glazed partiton, Door rebate profile to be used.In case of Glass overall panel Over Panel Door profile to be used. The profiles shall be suitable for Glass thickness of 10mm.The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. kg 782.00 Included 0.00 0 0
96 21.2.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides 18 MANUAL DOOR SLIDING SYSTEMS Providing and fixing a premium, heavy-duty synchronized sliding wooden door system designed for wall-fixing, utilizing the sliding track mechanism (Weight capacity max up to 150 Kgs per leaf). The system shall be equipped with the Synchro accessory set for simultaneous bi-parting operation, the Adaptor Profile, and timber door suspension brackets/hangers. The sliding door leaves shall be fabricated using 35mm thick, factory-pressed solid core flush doors (BWP Grade), finished with 1mm thick premium high-pressure laminate (HPL) on both faces and sealed with matching hardwood/teakwood lipping on all exposed edges. The rate is completely inclusive of supplying and installing the track system, internal rollers, stoppers, concealed timber floor guides, heavy-duty SS anchor fasteners, and routing/fixing flush pull knobs on both sides of the door leaves. The rate includes all materials, the 35mm laminated wooden shutters, hardware, skilled carpenter labor, cutting, assembly, and precise alignment to ensure smooth, frictionless, and perfectly plumb sliding operation to the satisfaction of the Engineer-in-Charge. Measurement shall be in Square Meters (Sqm) of the total structural opening area. sqm 30.92 Included 0.00 0 0
97 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 18 Providing and fixing partition stile door Junction profile (100 x 100 frame) sqm 6.30 Included 0.00 0 0
98 21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 18 "Supply and Installation of semi automatic Operable acoustic partition consists of 100 mm thick individually movable elements, suspended from top track only designed for sound Insulation of 55 dB. Each panel to have top and bottom operable pressure seals activated automatically by a 24V DC motor ensuring optimum contact pressure up to 800N. The elements must be inter-connected by means of a positive locking convex/concave aluminium profile integrated with magnetic strips having a linear attraction of 40 N/m. Elements must be constructed of a non-deflecting steel tube frame and aluminium profiles, bolted together. The frame must be clad either side with 16 mm MDF panels hung in acoustic isolation from the frame and allowed to vibrate independently of the frame. The facia panels must also be easily removable. The panel must be filled with high density rock wool in accordance with the specified sound insulation requirements. The telescopic element must open and close 120 mm and must be operated by a single mechanism for both the top and bottom seals. All this to the complete satisfaction of the Engineer-in-charge. Finish : Bare MDF Element Finish : Natural Anodized " Sound Barrier Partition above Operable Sliding/Folding Partition Providing and fixing to the required profile and shape 2 layers of 12.5mm thick Gypsum board on GI framework comprising 40x40x18G galvanized tubular frame 610x610mm centre to centre fixed on Roof Structure with 40x40x5 MS cleat, 100mm long 1200 c/c and ceiling framework with welded connections. The Gypsum board to be backed with 50mm thick resin bonded fiberglass cut to size and inserted in GI framework and held in place with 28G x 12mm GI wire netting. The first layer of Gypsum board to have joints over frame and second layer of Gypsum board tohave joint staggered with respect to the first layer, all joints between board in both layers to be taped with paper tape and filled with sealing compound. Gypsum board layer to be sealed at junction with Roof sheeting / structure and false ceiling below with the non-hardening mastic compound, so as to provide smooth surface.Entire work to be done as per drawing, specifications and as per directions of Engineer-in-charge.The cost of G.I structure is in the scope of contractor sqm 45.00 Included 0.00 0 0
99 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 18 Providing and fixing Roller Blinds as per the approved sample comprising of sunscreen Fabric comprising of 30% polyester and 70% PVC with openess factor of 5% having a width of 250-300 cm.Fabric weight 428±5% Grams per sqm, Thickness 0.73 mm ±5%, GREENGUARD NFPA701 ceritified fabric. Healty/safety standard - Oekotex Standard 100 and it provides UV protection upto 95%.The fabric has mechanical breaking resistance – warp≥ 1310 N/5cm, Weft: > 1420 N/5cm. Color fastnes to Light Grade 8.The Roller blind system consists of 38mm OD extruded out of Aluminium alloy 6063 T6 with silver anodized to provide an everlasting finish and luster, the rotary unit shall be 36mm in OD incorporating a clutch mechanism composed of low – flexing braided polyster cord with nylon core, Control Ball chain shall be composed of braided nylon cord (2mm dia) with high engineering grade plastic beads of 4.5mm diameter mounted co-axially on the cord with a pitch of 6.2mm (C-T-C) Bottom rail should be powder coated Aluminium flat bottom rail of 290 gm to finish it from the ends it should have rail end caps. The clutch will be at the tube. The return end cap bracket shall incorporate snap spring design to facilitate easy installation and removal for maintenance activities. The bracket shall be finished with a flush mounting cover on each side providing an aesthetic finish. It should handle up to 5 Kgs of material. The clutch should mount flush to the face of the bracket which minimize the light gap between the shade and the window frame. All complete as per approval of designer & instruction of Project Manager." sqm 14.06 Included 0.00 0 0
100 22.7.1 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 18 Fabrication and installation of wooden blind. Blinds will be operated with the help of cord. Head rail: U-Shaped roll formed steel. Dimensions 52 mm x 58 mm. Wall thickness 1mm. Finish: Powder Coated. Colour coordinated with slat colours. End caps are Colour coordinated with headrail and made of PVC material. Bottom Rail: Bottom rail is constructed of real wood of dimensions 50 mm x 16 mm. Colour coordinated with slat colours. Valance: Valance is constructed of real wood of dimensions 63 mm (front face). Colour Coordinated with slat colours. Mounting material: Installation bracket constructed of Zinc plated steel. Designed to use for both top of face fixing. Slat specifications: Thick PVC and wood slat of thickness 2.2mm and slat Width of 50mm (Width tolerance +/- 0.3mm). Colours and finishes available according to collection. Ladder String: 100% Braided Polyester with diameter of 1.4mm.Colour coordinated with the slat colours. Ladder tape: 100% Braided Polyester with dimensions of 25mm width (front side). Colour available according to selection. Control Unit- The control unit shall operate the tapes to provide at least 160 degrees of slat rotation and retain the same angle for all slats. This Control Unit shall not require lubrication after shipment, and shall be operated by either a ball chain or cords as specified. The length of the ball chain or cords shall be the manufacturer’s default compared to the specified length of the blind, unless otherwise specified. Unless otherwise specified, the location of the Control Unit shall be on the left side of the blind. Operation and durability of the tilt mechanism shall pass applicable testing. If cords are specified for operation, cord durability, strength and colourfastness shall pass applicable testing. Control unit should be made of 1:6 gear ratio, to ensure easy lifting of the blind. Outer body should be made of Nylon, inner gears are made of Polyoxymethylene. Spring made of Square Stainless-steel wire 1,2mm X1.12MM. Spools- made of Polyoxymethylene. Spring made of stainless-steel wire SUS 304. sqm 279.46 Included 0.00 0 0
101 NS BATHROOM IN A BOX of CERA Fountain Cat No Cat. No. F2013901 page 84 (F2013101 Pillar cock - QTY 1 F2013401 Wall Mixer 2-in-1 - QTY 1 F7010213AB Overhead Shower - QTY 1 F8030104AB Health Faucet - QTY 1 F8040204 Angle Cocks - QTY 3) 18 Aluminium Skirting "Providing and fixing 100mm height two-part modular extruded aluminium floor skirting. The system shall consist of a concealed structural aluminium wall retainer fixed to the masonry/partition wall using dash fasteners/screws at regular intervals, and a snap-on decorative aluminium cover profile of 1.5mm thickness. The finish shall be factory-anodized [Satin Silver / Black / Champagne]. The rate shall include the cost of all materials, hardware (screws, PVC rawl plugs), moulded internal/external corner connectors, end caps, wastage, and labour for installation in perfect line and level, complete as per manufacturer's specification and direction of the Engineer-in-Charge. Make: Bottomline, Inpro or equivalent" cum 7.00 Included 0.00 0 0
102 NS Providing AND fixing CP brass stop cock concealed of F1020361 15 mm Concealed stop cock with adjustable wall flange Page 70 18 SS Transition Strips Providing and fixing Stainless Steel (SS) Grade 304 transition strip at the junction of carpet and hard floorings. The top visible cover profile shall be 25mm wide and 1.5mm thick, featuring machine-buffed, chamfered edges to ensure a smooth, trip-free transition and prevent carpet fraying. The installation must utilize a completely concealed fixing system such as a screwed-down aluminium/SS base track with a snap-on SS top profile, or an anchor flange concealed beneath the flooring), ensuring zero visible fasteners on the finished surface. The visible SS surface shall be finished to a [Satin Brushed / Mirror] polish. The rate shall include the cost of all materials, sub-floor preparation, mechanical fasteners, heavy-duty construction adhesive/epoxy where required, wastage, edge buffing, and skilled labour, complete in all respects as per Architect's instruction, detailed design, and drawings. each 14.00 Included 0.00 0 0
103 NS Providing and fixing Central hole basin mixer with 450 mm braided connection pipe (without pop-up) F1015454 18 Aluminium Corner Guards "Providing and fixing 25 mm x 25 mm extruded Aluminium corner guards to column edges, wall edges, or designated high-traffic corners. The system shall be a two-part concealed assembly consisting of a continuous structural aluminium base retainer and a snap-on aluminium outer capping to completely conceal all mechanical fasteners. The aluminium profiles shall have a minimum wall thickness of 1.5mm and a factory-finished Satin Anodized / Powder-Coated]surface. The base retainer shall be securely fixed to the masonry/drywall plumb and true to line using appropriate rawl plugs and counter-sunk screws at maximum 300mm intervals. The rate shall include the cost of all extrusions, top/bottom end caps , mechanical fasteners, wastage, staging, and skilled labour required to install the guards seamlessly as per Architect's instruction, detailed design, and drawings. each 8.00 Included 0.00 0 0
104 NS Providing and fixing Towel Ring F5013115CH 18 Wallpaper Providing and Fixing fabric backing commercial grade wall paper of approved shade with recommended adhesive of approved make which have 100% washable, scratch resistance, peel proof, and fire retardant properties. Cost to include preparation on the punned surface for receiving the wall paper as per the Manufacturer specifications and Directions, etc. complete to the satisfaction of the Architect. (200-300 GSM) each 8.00 Included 0.00 0 0
105 NS Providing and fixing F5013103CH Towel Rail 600 mm (24") 18 MS Support for Camera , Wi-Fi and Ceiling Mounted Projector Fabricating & fixing MS Support from true ceiling for Camera & Wi-Fi at given location as per instruction by Architect each 7.00 Included 0.00 0 0
106 NS Providing and fixing F5013106CH Soap Dish 18 Providing and fixing Stainless steel grade 202 round open top Dustbin, size - 10x14 Inch each 8.00 Included 0.00 0 0
107 NS Providing AND fixing F10991612 - Way bib cock withside handle, wall flange and aerator 18 Providing and fixing Company Name & Logo Signage in Reception/ Entrance Lobby using 12mm acrylic Channel letters + colour as per pantone shade of Dupont make (min 3 coats ) fixing by Double sided tape. Logo : 720mm x 665mm Hindi : 1615mm x 360mm English : 1580mm x 265mm each 3.00 Included 0.00 0 0
108 NS Providing and Fixing Cera make or equivalent WALL HUNG WASH BASINS WITH FULL PEDESTAL CALLIO 575 x 460 x 145 mm with full pedestal height 830 mm Cat. No. S2040209 Wash basin Cat. No. S2090135 Full Pedestal 18 Providing and fixing of Door Push - Pull, signages: 1.5 mm SS brushed finish + Etching + Lacquer, + Anodized, fixing by 3M Double sided tape. Size -100mm x 100mm each 8.00 Included 0.00 0 0
109 NS Providing and Fixing of Bathroom Corners shelf F5005201 Corner glass shelf with 2 racks 18 Providing and fixing Company Name & Logo Signage in Reception/ Entrance Lobby: Size of the logo will be 2400mm x 665mm Bounce back letters : SS 304 grade finish letters with halo effect. Raising will be SS and back will be 3mm acrylic with raising to create halo effect Logo : 720mm x 665mm Hindi : 1615mm x 360mm English : 1580mm x 265mm each 7.00 Included 0.00 0 0
110 NS Providing AND fixing long body bib cock with wall flange and aerator of make QT F2006152 and HTF3001152- 15mm nominal bore 18 Fire Extinguisher signages - size (300mmx180mm) each 20.00 Included 0.00 0 0
111 NS Providing and fixing angular stop cock of make QT F2006201 abd HT F3001201 18 Fire Extinguisher Stand Each 30.00 Included 0.00 0 0
112 NS Providing AND fixing of wooden shelves AND drawers for cupboards in bedrooms including all fixtures in Cupboard having two shutters excluding cost of shutters but including priming one coat of approved primer and two coat of approved synthetic enamal paint complete as per drawing and direction of Engineer-in-charge. 18 Supply and Installation of Pen tray for the pen, duster . size (750x150mm) / (1000x150mm) Sqm 10.00 Included 0.00 0 0
113 NS Providing and fixing wall cabinet 300 mm deep with 19 mm thick prelaminated particle board of approved shade in shutters , top , bottom and all sides commercial block board 19 mm thick in shelves and vertical and horizontal patition with 6mm thick first class teak lipping over edges as per drawing. Priming with one coat and painting with synthetic enamel paint to commercial boards complete. Front area shall be measured for payment 18 Door Mats "Supply and fixing of INTERCONNECTED ROLLING - ALUMINIUM MATTING - Profile Colors : Silver or Black, Position of Matting : Inside/Foyer Area, Material : Aluminium Profile with Carpet, Area : High Traffic,Trolley Crossings : Heavy Trolley, Maintenance : Easy to clean, Application :Recessed / Surface" Size - 2000mm x 900mm, of approved shade and design sqm 6.20 Included 0.00 0 0
114 NS Providing and fixing 19 mm thick prelaminated particle board both side laminated of approved shade in shutters ,with first class lipping alround in central provinces teak frame of 35 x 50 mm and 50x50 mm vertical members and shelves in commercial block board 19mm thick vertical AND horizontal partition with 6mm thick first class teak lipping over edges as per drawing. Priming with one coat and painting with synthetic enamel paint to commercial boards complete. Below cooking counter Front area shall be measured for payment 18 Graphics Providing & fixing Graphic Film of approved make, with recommended adhesive of approved make & sample as per manufacturer's specifications. Rate of Wall Graphics film shall be inclusive of Design, Image cost & preparation on the punned surface for receiving the graphic. sqm 7.70 Included 0.00 0 0
115 NS Moulding and cornices with brick masonry in cement mortar 1:4 1 (Cement - 4 coarse sand) girth to be measured in cm and length in running metre. 18 Frosted Film Providing and applying Vinyl glass privacy film on internal glass parition or window/door glass panels neatly complete as directed by the architect/EIC. The film must be manufactured with a thickness of 3mm and utilize a pressure-sensitive adhesive. Minimum performance requirements mandate a Visible Light Transmittance (VLT) of 70%, a Total Solar Energy Rejected (TSER) of 48%, a Solar Heat Gain Coefficient (SHGC) of 0.52, and an Ultraviolet Rejection (UVR) of greater than 99%. Custom Printed design on glazed surfaces shall be as per design if required, installation as per manufacturer's specifications and guidelines. per metre per cm. Girth 3725.50 Included 0.00 0 0
ELECTRICAL PORTION
116 SUB HEAD - I - PVC INSULATED STRANDED COPPER CONDUCT OR WIRING IN STEEL CONDUIT ARTISTIC WALL FEAUTURE DEPICTING PGCIL'S INCEPTION, GROWTH AND JOURNEY ART WITH MURAL AND INTERNAL CONCEPT CREATION Providing and fixing thematic timeline wall display comprising wall preparation with putty, primer and premium paint finish. Feature wave element shall be made from 10mm thick CNC cut PVC sheets fixed on wall with concealed supports. Joints between PVC sheets shall be treated with putty, sanded and painted to achieve a seamless monolithic finish without visible panel joints. Wave element shall incorporate continuous LED cove lighting with aluminium profile, diffuser, LED strips, drivers and wiring complete. All text, graphics and timelines shall be executed in high-resolution self-adhesive vinyl applied directly on painted wall. Photographs shall be produced as UV printed acrylic frames with concealed fixing arrangement. Item includes all hardware, electrical accessories, installation, testing and commissioning, complete in all respects as per approved design and direction of Engineer-in-Charge. Approved Make - Designer/artist with relevant experience shall be approved by EIC 0 0
117 1.10 Wiring for light point OR fan point OR exhaust fan point with 1.5. Sq.mm FR PVC insulated, copper conductor cable in surface OR recessed medium class PVC conduit with modular switch Anchor or equivalent make , modular plate, suitable GI box AND earthing the point with 1.5 sq.mm FR PVC insulated copper conductor cable etc. as required. Providing and fixing a custom minimal art wall installation, comprising a seamlessly curved wooden panel base, concealed lighting, and floating metal artwork. The base structure shall be fabricated using 1" x 1.5" GI at 16" center-to-center, clad with 12mm thick commercial BWR-grade plywood and topped with 6mm thick flexible plywood to achieve the continuous curved profile. The surface shall be finished with 4mm thick premium decorative natural wood veneer matching the existing reception interiors and sealed with three coats of premium matt PU or Melamine clear polish. The work includes supplying and installing warm-white (3000K-4000K) flexible LED strip lighting (120 LEDs/meter) concealed within an extruded aluminum profile with frosted diffusers and appropriate SMPS drivers at the top edge to create a soft cove lighting effect. Additionally, the item entails the custom fabrication and installation of a minimalist transmission line artwork utilizing SS 304 grade solid flat bars or round rods; the design is to be CNC laser-cut, seamlessly welded, and finished with a designer-approved electroplated or PVD coating (such as brushed steel or matte black). The metal artwork shall be securely mounted onto the curved wooden ground using concealed stainless steel studs or spacers to achieve a 1-inch floating effect with no visible fasteners. The rate shall be inclusive of all necessary hardware, edge-binding, Fevicol SH adhesives, staging, and final site cleaning to complete the installation as per the design intent and site conditions. Approved Make - Designer/artist with relevant experience shall be approved by EIC 0 0
118 1.10.2 Group B 18 Point 147.00 Included 0.00 0 0
119 1.11 Wiring for twin control light point with 1.5. Sq.mm FR PVC insulated, copper conductor single core cable in surface OR recessed medium class PVC Conduit, 2 way modular switch Anchor or equivalent make , modular plate, suitable GI box AND earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. 18 Point 14.00 Included 0.00 0 0
120 1.12 Wiring for light OR Power plug with 2X4 sq.mm FR PVC insulated, copper conductor single core cable in surface OR recessed medium class PVC conduit alongwith 1 No. 4 sq.mm FR PVC insulated, copper conductor single core cable for loop earthig as required. 18 Mtr. 530.54 Included 0.00 0 0
121 1.14 Wiring for circuit OR submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor single core cable in surface OR recessed medium class PVC conduit as required. 18 Included 0.00 0 0
122 114.2 2 x 2.5 Sq.mm PLUS 1X2.5 sq.mm earth wire 18 Mtr. 338.62 Included 0.00 0 0
123 1.14.4 2 x 6 Sq.mm PLUS 1X6 sq.mm earth wire 18 Mtr. 0.00 Included 0.00 0 0
124 1.14.9 4x6 Sq.mm PLUS 2X6 sq.mm earth wire 18 Mtr. 0.00 Included 0.00 0 0
125 SUB-HEAD-- II PVC OR Steel CONDUITS 18 Included 0.00 0 0
126 1.21 Supplying and fixing of following sizes of medium class PVC conduit alongwith the accessories in surface OR recess including cutting the wall and making good the same in case of recessed conduit as required. For Telephone AND TV cable 18 Included 0.00 0 0
128 SUB-HEAD- III SUPPLYING AND FIXING METAL BOXES 18 Included 0.00 0 0
129 1.27 Supplying and fixing following size OR modules, GI box along with modular base AND cover Plate for modular switches in recess etc as required. 18 Included 0.00 0 0
130 1.27.1 1 or 2 Module 75 mm x 75 mm for telephone AND TV socket 18 Each 10.00 Included 0.00 0 0
131 1.27.5 8 Module 125 mm x 125 mm INSPECTION BOX 18 Each 4.00 Included 0.00 0 0
132 SUB HEAD - IV ERECTION OF FITTINGS AND ACCESS OR IES - 18 Included 0.00 0 0
133 1.24 Supplying AND fixing following modular switch OR socket Anchor or equivalent make on the existing plate AND switch box including connections but excluding modular plate etc. as requried. 18 Included 0.00 0 0
134 1.24.1 5 OR 6 amps switch 18 Each 58.00 Included 0.00 0 0
135 1.24.4 3 OR 5 pin 5 OR 6 amps socket outlet 18 Each 58.00 Included 0.00 0 0
136 1.24.6 Telephone socket outlet 18 Each 10.00 Included 0.00 0 0
137 1.24.7 TV Antena Socket out let 18 Each 10.00 Included 0.00 0 0
138 1.25 Supplying and fixing stepped type electronic fan regulator on existing modular plate switch box including connection but excluding modular plat etc. as required. 18 Each 21.00 Included 0.00 0 0
139 1.31 Supplying and Fixing suitable GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 OR 5 pin 5 OR 6 amps modular socket outlet and 5 OR 6 modular switch, connection, painting etc. as required. Near TV point OR toilet OR kitchen OR as required 18 Each 7.00 Included 0.00 0 0
140 1.32 Supplying and Fixing suitable GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15 OR 16 AND 5 OR 6 amps modular socket outlet and 15 OR 16 modular switch, connection, painting etc. a required. 18 Each 44.00 Included 0.00 0 0
141 1.38 Supplying and fixing of call bell OR buzzer suitable for DC OR AC single phase 230V supply complete as required. 18 Each 4.00 Included 0.00 0 0
142 1.41 Installation, testing and commissioning of prewired fluorescent fitting of all types complete with all accessories and tubes etc. directly on ceiling OR wall including connections with 1.5 Sq.mm FR PVC insulated copper conductor, single core cable and eathing etc. as required 18 Each 107.00 Included 0.00 0 0
143 1.44 Installation, testing and commissioning of ceiling fan wiring the down rod of standard length upto 30 cm with 1.5 Sq.mm FR PVC insulated copper conductor, single core cable etc. as required. 18 Each 21.00 Included 0.00 0 0
144 1.50.1 Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage. Connection, testing and commissioning etc. as required. 18 Each 11.00 Included 0.00 0 0
145 SUB-HEAD - V - MCB s OR RCBOs Included 0.00 0 0
146 2.10 Supplying AND fixing 5 to 32 Amps rating 240 OR 415V C-Curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand OR Hagger or equivalent make Included 0.00 0 0
147 2.10.1 Single Pole SP 18 Each 40.00 Included 0.00 0 0
148 2.10.2 Single Pole and neutral SPN 18 Each 1.00 Included 0.00 0 0
149 2.10.5 Triple Pole and neutral TPN 18 Each 3.00 Included 0.00 0 0
150 2.14 Supply AND fixing following rating double pole Single phase AND neutral 240V residual current circuit breaker RCCB , having a sensitivity current up to 300 mA in existing MCB DB Complete with connections testing and commissioning etc. as required. 18 Included 0.00 0 0
152 2.15 Supply AND fixing following rating four pole Three phase AND neutral 415V residual current circuit breaker RCCB , having a sensitivity current upto 300 mA in existing MCB DB complete with connections testing and commissioning etc. as required. 18 Included 0.00 0 0
153 2.15.2 40A Four pole 18 Each 0.00 Included 0.00 0 0
154 2.15.3 63A Four pole 18 Each 3.00 Included 0.00 0 0
155 SUB-HEAD -VI MCB DISTRIBUTION BOARD 18 Included 0.00 0 0
156 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board Hawells or equivalent , 240 volts, on surface OR recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dun bar, interconnections, powder painted including earthing etc. as required. But without MCB OR RCCB OR Isolator 18 Included 0.00 0 0
157 2.3.8 2 PLUS 12 WAY , double door 18 Each 0.00 Included 0.00 0 0
158 2.4 Supplying and fixing following way, three pole neutral, sheet steel, MCB distribution board Hawells or equivalent , 415 volts, on surface OR recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dun bar, interconnections, powder painted including earthing etc. as required. But without MCB OR RCCB OR Isolator 18 Included 0.00 0 0
159 2.4.4 4 way 4PLUS 12 , Double door 18 Each 3.00 Included 0.00 0 0
160 SUB-HEAD -VII EARTHING 18 Included 0.00 0 0
161 5.2 Earthing with GI earth pipe 4.5 m Long x 40 mm dia including accessories AND providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal or coke and salt complete etc. as required. 18 Set 1.00 Included 0.00 0 0
162 5.11 Providing and fixing 25 mm x 5 mm GI strip in 40mm dia GI pipe from earth electrode including connection with GI nuts, bots, spring, washers, excavation and re-filling as required. 18 Mtr. 0.00 Included 0.00 0 0
163 5.17 Providing AND fixing 4 mm dia copper wire on surface OR in recess for loop earthing as required. 18 Mtr. 0.00 Included 0.00 0 0
164 SUB-HEAD - VII LIGHTNING PROTECTION 18 Included 0.00 0 0
165 6.1 Providing and fixing of lightning conductor finial , made of 25 mm dia 300 mm long copper tube having single pronge at top with 85 mm dia 3 mm dia thick copper base plate including holes etc. complete as required. 18 each 2.00 Included 0.00 0 0
166 6.4 Jointing copper OR GI tape with another copper OR GI tape, base of finial or any other mettalic object by riveting OR nut bolting OR sweatingAND soldring etc as required. 18 each 87.00 Included 0.00 0 0
167 6.7 Providing and fixing GI tape of 20 mmx 3mm thick on parapet or surface of wall for lightning conductor as required for horozontal run 18 Mtr. 125.48 Included 0.00 0 0
168 6.8 Providing and fixing GI tape of 20 mm x 3mm thick on parapet or surface of wall for lightning conductor as required for vertical run 18 Mtr. 85.46 Included 0.00 0 0
169 6.12 Providing and fixing testing joints 20 mm x 3 mm thick GI strip 125 mm long with 4 nos. GI bolts, nuts, check nuts and spring washer etc. complete as required. 18 each 0.00 Included 0.00 0 0
169 SUB-HEAD - IX TELEPHONE AND TV WIRING Included 0.00 0 0
170 1.18 Supplying and drawing following pair 0.5 mm OR 0.6 mm FR PVC Insulated annealed copper conductor, unarmoured telephone cable in existing surface OR recess steel OR PVC conduit as required. Included 0.00 0 0
171 1.18.3 4 pair 18 Mtr. 147.98 Included 0.00 0 0
172 1.19 Supplying AND drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface OR recessed steel OR PVC conduit as required. 18 Mtr. 144.16 Included 0.00 0 0
173 8.11.3 LED Batten light 36W (System lumen efficacy >135 lm/Watt), Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18 EACH 32.00 Included 0.00 0 0
174 NS INNOVA NEO 12 W LED 6500 K of Havells LHEEALPFIH1W012 18 EACH 50.00 Included 0.00 0 0
175 NS Bracket Light CRYSTA DECO COB 7 W 6 K WHITE LHEEBEPGUE1W007 18 EACH 32.00 Included 0.00 0 0
176 NS Bulk Head 9W LED 6500 K LHEBADP7IZ1W009 18 EACH 9.00 Included 0.00 0 0
177 NS Surface mounted Austra Cabinet LED Batten 12 W 4000 K CFL mirror Lights LHEXBDP6UN1W012 18 EACH 8.00 Included 0.00 0 0
178 NS ceiling fans Astura BLDC 1200 mm sweep By Havells 18 EACH 15.00 Included 0.00 0 0
179 NS metal type exhaust fans Turbo Force 300 mm 1400 r/min By Havells 18 EACH 10.00 Included 0.00 0 0
180 NS INSTALLATION-WATER HEATER Electric Geyser 25L By Havells GHWVVEDMEW25 18 EACH 3.00 Included 0.00 0 0
181 NS INSTALLATION-WATER HEATER Electric Geyser 10L By Havells GHWVVEDMEW10 18 EACH 3.00 Included 0.00 0 0
TOTAL AMOUNT EXCL GST 0.00 0 0
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682) Schedule - 3
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
#REF! To: As per Percent on Sch-3 #REF!
#REF! #REF! Total Discount #REF!
Name : #REF! #REF!
Address : #REF! #REF!
#REF! #REF! Multipackage lum-sum #REF!
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : #REF! Printed Name : #REF!
Designation : #REF!
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682) Schedule - 4b
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI
(SCHEDULE OF RATES AND PRICES )
Name : #REF! #REF!
Address : #REF! #REF!
Maintenance Charges during & after Defect Laibility Period
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Maintenance Charges excluding GST Total Maintenance Charges excluding GST Total GST as confirmed by Bidder
#REF! Revaluation of P column Tax Calculation
A. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
B. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
Total Maintenance Charges during and after Defect Liabilty Period 0.00 0
Total GST as confirmed by Bidder 0.00
Date : #REF! #REF!
Place : #REF! #REF!
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Schedule - 2
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(SUMMARY OF TAXES & DUTIES APPLICABLE )
Bidder's Name and Address (Sole Bidder): To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : SCO Bay 5-10, near Haryana Pollution Control
board Office, Sector 16A, Faridabad, Haryana 121002
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST 0.00 #REF! #REF! #REF! #REF!
TOTAL GST 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682) Schedule - 5
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Name : #REF! #REF!
Address : #REF! #REF!
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES #REF!
Total GST on Installation Services (Schedule-3), Training to be imparted in India (Schedule-4a) and Maintenance Charges during and after Defect Liabilty Period (Schedule-4b)
GRAND TOTAL [1+2] #REF!
Date : #REF! Printed Name : #REF!
Place : #REF! Designation : #REF!
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Schedule -3
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(GRAND SUMMARY)
Bidder's Name and Address (Sole Bidder): To:
Name : Contracts Services, 3rd Floor
Address : Power Grid Corporation of India Ltd.,
SCO Bay 5-10, near Haryana Pollution Control
board Office, Sector 16A, Faridabad, Haryana 121002
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
2 TOTAL BID PRICE EXCL GST 0.00
3 GST AS PER SCHEDULE NO. 2 0.00
4 GRAND TOTAL [10+11] 0.00
Date : Printed Name :
Place : Designation :
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682)
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
#REF! To: As per Percent on Sch-7 #REF!
#REF! #REF! Total Discount #REF!
Name : #REF! #REF!
Address : #REF! #REF!
#REF! #REF! Multipackage Discount #REF!
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : #REF! #REF!
Place : #REF! #REF!
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Tender Enquiry No.:NR1/NT/W-CIVIL/DOM/I00/26/13605; (RFX- 5002005682)
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Name : #REF! 0 0
Address : #REF! 0 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Schedule - 6 After Discount
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(GRAND SUMMARY)
Bidder's Name and Address (Sole Bidder): To:
Name : Contracts Services, 3rd Floor
Address : Power Grid Corporation of India Ltd.,
SCO Bay 5-10, near Haryana Pollution Control
board Office, Sector 16A, Faridabad, Haryana 121002
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
2 TOTAL SCHEDULE NO. 2 (Taxes and Duties) 0.00
GRAND TOTAL [1+2] 0.00
Date : Printed Name :
Place : Designation :
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Letter of Discount
LETTER OF DISCOUNT
Contracts Services, 3rd Floor
Power Grid Corporation of India Ltd.,
SCO Bay 5-10, near Haryana Pollution Control
board Office, Sector 16A, Faridabad, Haryana 121002
Subject : Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us in Rs #REF! #REF!
2 Discount on lum-sum basis on total price quoted by us in Percent(%) #REF! 0.00%
Discount(s) offered at sl. No. 1 to 2 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702) Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
SCO Bay 5-10, near Haryana Pollution Control 11 th 11 November
board Office, Sector 16A, Faridabad, Haryana 121002 12 th 12 December
Name of Contract : Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Installation Charges. 21 st
Schedule 2 Taxes and Duties not included in Schedule 1 22 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 1
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges #REF! #REF!
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. #REF! #REF!
3 TOTAL SCHEDULE NO.3: Installation Charges #REF! #REF!
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) #REF! #REF!
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX #REF! 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
#REF! Excise Duty #REF! #REF!
#REF! CST #REF! #REF!
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind Statement of Quoted / Corrected Prices Page
Spec. No. Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 ; (RFX- 5002005702)
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges #REF! #REF!
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. #REF! #REF!
3 TOTAL SCHEDULE NO.3: Installation Charges #REF! #REF!
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) #REF! #REF!
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! #REF!
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] #REF! #REF!
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. #REF! Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. #REF! #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
PGCIL OFFICE INTERIOR WORKS AT 5TH FLOOR, TOWER C, WORLD TRADE CENTRE, NAUROJI NAGAR, NEW DELHI Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Package : Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Specification No. : NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702)
Completion Period 12 Months
: Attachments : General guidelines for filling up the Attachments Construction of Residential Complex: - :
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Specification No.: NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702)
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
7 Attachment 18 Safety Pact : To be submitted as per ITB Clause No. 9.3(r) and as per remarks in the Attach 18.
8 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder
9 Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
10 Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
11 Attachment 23: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Sole Bidder 1
Yes JV (Joint Venture) 2 or More
Enter following details of the bidder No
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 2 0
Address of Bidder
Whether the bidder is an MSE (Micro & Small Enterprise) Yes Yes 2 2 0
Enter the Name of Registration Authority
Whether the bidder meets Minimum Local Content in line with PPP-MII order, 2017 0 2 2 0
e-mail ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory MSE Yes
Name of other Partner Ram Lal
Address of other Partner G5
Name of other Partner - 2 (more, if any)
Address of other Partner - 2 (more, if any)
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-3(JV) Sole Bidder
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address To:
Contract & Materials & Ram Lal
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
This Attachment is Not Applicable
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith Sole Bidder
Date : -- Printed Name : 0
Place : Designation : 12
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-3(QR)
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract & Materials
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 Northern Region –I, Regional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Faridabad-121002
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) #REF! 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm 0
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Date of Commercial production
9 Nationality of
10 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid.
11 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
1.1 1.0 Technical Experience: Bidder should have Successfully# completed any project of institutional / commercial / Residential complex during last seven (7) years as on the originally scheduled date of bid submission , as per following i) Under one contract of value of not less than Rs. 89.66 Lakh excl GST OR (ii) Under two contracts each of value not less than Rs. 56.04 Lakh excl GST OR (iii) Under three contracts each of value of not less than Rs. 44.83Lakh excl GST
1.2 Route-2: The bidder(s) who have established production line and testing facilities in India for 715kV or above class Reactor based on Technological Support of the Collaborator(s) for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715kV or higher voltage class either One (1) no. 1-phase Reactor of at least 80 MVAR capacity or One (1) no. 1-phase Transformer of at least 166 MVA capacity and the same should have been supplied as on the date of bid opening as mentioned above based on Technological Support of Collaborator(s) provided that:- (a) Collaborator(s) meets the Technical Experience criteria stipulated in Route-1. (b) A legally enforceable undertaking jointly by Bidder and the Collaborator(s) (as per enclosed format in Section-VI of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Collaborator(s) along with the bid stating that Collaborator(s) shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
1.3 Route-3: In case, the bidder is an Indian Entity established as Subsidiary/JVC/Group company by its parent/principal, who have established production line and testing facilities in India for 715kV or above class Reactor based on Technological Support of the parent/principal for the equipment(s) can also be considered qualified provided, The bidder must have manufactured in India, type tested 715kV or higher voltage class either One (1) no. 1-phase Reactor of at least 80 MVAR capacity or One (1) no. 1-phase Transformer of at least 166 MVA capacity and the same should have been supplied as on the date of bid opening as mentioned above based on Technological Support of Parent/ Principal company provided that:- (a) Parent/ Principal company meets the Technical Experience criteria stipulated in Route-1. (b) A legally enforceable undertaking jointly by Bidder and the Parent/ Principal company (as per enclosed format in Section-VI of bidding document) is furnished along with the bid, to guarantee quality, timely supply, performance and warranty obligations for five(5) years for entire quantity to be manufactured and supplied from the works in India and a confirmation letter from the Parent/ Principal company along with the bid stating that Parent/ Principal company shall furnish performance guarantee for an amount of 10% of the cost of such equipment(s). This performance guarantee shall be in addition to contract performance guarantee to be submitted by the bidder.
In case bidder is a holding company, the technical experience referred to in para 1.1 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in para 1.1 above shall be of that subsidiary company only (i.e. excluding its holding company).
Using the following formats, each Bidder is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format-A: (ROUTE-1)
Format for the Bidder/ Collaborator/ Parent/Principal Company of the bidder who must have designed, manufactured, tested & supplied 715kV or Higher Voltage class Reactor in support of meeting the Technical experience requirement of 1.1 of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : 0 0
Single Firm : 0
1 Name of Contract Undertaken 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of Reactors supplied under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactors with rating not less than 110 MVAR OR no. of Reactors in Banks of 3 single phase units of at least 36.7 MVAR each)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
(a)(ii) No. of years, the above Reactor(s) are in operation as on the date of bid opening.
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Reactors of Reactors
of Reactors of Reactors
Details of documents uploaded in support of the above stated experience
4(b)(i) Voltage Level of Transformers supplied under the Contract (Indicate 715kV or above class only)
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 500 MVA OR no. of Transformer in Banks of 3 single phase units of at least 166 MVA each)
MVA capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Type of cooling in the above Transformer
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Transformers of Transformers
of Transformers of Transformers
Details of documents uploaded in support of the above stated experience
4(b)(ii) Voltage Level of Reactors supplied under the Contract (Indicate 345kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 3 phase Reactors with rating not less than 50 MVAR OR no. of Reactor(s) in Banks of 3 single phase units of at least 16.7 MVAR each)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by Bidder
(Tick whichever is/are applicable)
of Reactors of Reactors
of Reactors of Reactors
Details of documents uploaded in support of the above stated experience
4(b)(iii) No. of years, the above transformer(s) and reactor(s) indicated at 4(b)(i) & 4(b)(ii) respctively, are in operation as on the date of bid opening.
Details of documents uploaded in support of the above stated experience
Format-B: (ROUTE-2)
Format for Bidder(s) [who have established production line and testing facilities in India for 715kV or above class Reactor based on Technology Support of Collaborator(s)], in support of meeting the requirement of 1.2 (Route-2), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents
Name of the Reactor Manufacturer 0 0
1 Name of Contract Undertaken 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4 Voltage Level of Reactors manufactured under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactors with rating not less than 80 MVAR)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
whether the above Reactors are in operation as on the date of bid opening.(Yes/No)
No. of years, the above Reactors are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Voltage Level of Transformer supplied under the Contract
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 166 MVA)
MVA capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Whether the above Transformer are in operation as on the date of bid opening.
No. of years, the above Transformer are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format-C: (ROUTE-3)
Format for Bidder (Indian entity) established as Subsidiary/ JVC/ Group Company by its Parent/ Principal, who have established production line and testing facilities in India for 715kV or above class Reactor, in support of meeting the requirement of 1.3 (Route-3), Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Bidder 0
Name of the Parent Company/Collaborator/Subsidiary for the 765kV Reactor {The qualifying data for the parent company or collaborator for the equipment is furnished in Format-A above) 0
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 Voltage Level of Reactor supplied under the Contract (Indicate 715kV or above class only)
No. of Reactor(s) under the contract
(Indicate nos. of 1 phase Reactor with rating not less than 80 MVAR)
MVAR capacity of the above mentioned three phase/single phase units
Name of the substation or switchyard
Date as on which the above mentioned Reactors are supplied based on technological support of parent company / collaborator(s) / subsidiary.
Type of cooling in the above Reactor
Scope of work involved under the Contract executed by bidder
(Tick whichever is/are applicable)
Voltage Level of Transformer supplied under the Contract
No. of Transformer(s) under the contract
(Indicate nos. of 1 phase Transformer with rating not less than 166 MVA)
Name of the substation or switchyard
(b)(ii) Whether the above Transformer are in operation as on the date of bid opening.
No. of years, the above Transformer are in operation as on the date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
5 Whether Parent/Principal company(s) meets the technical experience criteria stipulated at 2.1.1 above, and the details of which is mentioned at Format-A above. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
6 Whether legally enforceable undertaking jointly by Bidder and the Parent/Pricipal company(s) (as per enclosed format in Section-VI: Sample Forms and Procedures of bidding document) is furnished along with the bid. (Applicable for the Bidder/Manufacturer(s) wish/proposes to qualify through Route-3 of Annexure-A(BDS))
7 Confirmation letter from the Parent/Principal Company along with the bid stating that Parent/Principal Company shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s) to be manufactured and supplied from the works in India. (Applicable for the Bidder wish/proposes to qualify through Route-3 of Annexure-A(BDS))
8 Details of documents uploaded in support of the above stated experience Annex-XXX Annex-YYY Annex-ZZZ
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.2 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
(a)Minimum Average Annual Turnover @ (MAAT) for best 3 financial years out of last 5 financial years of the bidder should not be less than INR . 168.11 Lakh excl GST
b Minimum Average Annual Turnover^ (MAAT) for best three (3) years i.e. 36 months out of last five (5) financial years of the bidder should be Rs. 1233.18 million or equivalent for Reactor Package RT-08 ^ Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income.
c Bidder shall have liquid assets (L.A.) or/and evidence of access to or availability of credit facilities of not less than Rs. 205.53 million or equivalent for Reactor Package RT-08
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) but no later than seven (7) years from the date of incorporation of the said company as on the originally scheduled date of bid opening as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he meets the turnover requirement on their own or completes five (5) years from the date of commercial production of such equipment(s) in India but no later than seven (7) years from the date of incorporation as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered.
(iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/MSEs, meeting the specified requirements at Para 2 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2 (b) & 2 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
Note: For MSME registered firm, relaxation of 20% on financial aspects i.e MAAT requirement will be considered
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data for Bidder: 2 or more
Name of the Bidder
Whether the complete Annual Reports together with Audited Financial Statement of accounts/equivalent documents of the company for the FY of immediately preceding the date of submission of bid are available?
Financial year Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
A Turnover details:
Sl No Financial year Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
5.0 Financial Qualification Data for Parent/Principal Company/Collabrator (If Applicable): 0
Name of Parent/Principal Company/Collabrator
Whether the complete Annual Reports together with Audited Financial Statement of accounts/equivalent documents of the company for the FY of immediately preceding the date of submission of bid are available?
Financial year Networth (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
B Turnover details:
Sl No Financial year Turnover (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
6 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
6.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
6.2 Technical Credentials: List of work regarding past experience indicating the execution of similar work successfully, schedule time of completion and actual time of completion, the present status of projects in hand along with presently envisaged completion dates, qualification and experience of key personnel proposed for carrying out the subject work. List of available T & P and Manpower available with the bidder is also to be enclosed. Litigation History: The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder may result in rejection of Bid.
6.3 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-3(QR)
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner of) : To:
Contract Services
Address: 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(ii) 0 2 or more
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Name of the Bidder
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
9 Whether the bidder is an MSE (Micro & Small Enterprise). If Yes, attach Documentary Evidence with the Bid.
10 Whether the Bidder is a Start-Ups Company (as defined by DIPP). If Yes, attach Documentary evidence with the Bid.
2.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
2.1.1 The bidder must have designed, manufactured, tested, supplied, installed and commissioned 345kV or above class 3-phase transformers of at least 200 MVA or at least three (3) nos. 1-phase Transformers each having capacity of at least 66.7 MVA and the same Transformer(s) must have been in satisfactory operation* for atleast two (2) years on the originally scheduled date of bid opening i.e. 19.02.2019.
*Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
2.1.2 The 345 kV or above class transformer manufacturer(s) who have established production line in India for these equipment(s) based on technological support of a parent company or collaborator for the respective equipment(s) can also be considered provided i) such manufacturer has designed, manufactured, tested, supplied, installed and commissioned 220KV or above class transformers. ii) the parent company (Principals) or collaborator meets qualifying requirements stipulated at para 2.1.1 above; and iii) The 345 kV or above class transformer manufacturer(s) furnishes a) a legally enforceable undertaking (jointly with the parent company or collaborator) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); and b) a confirmation letter from the parent company or collaborator alongwith the bid stating that parent company or collaborator shall furnish performance guarantee for an amount of 10 % of the cost of such equipment (s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the Bidder. Note-1: In case bidder is a holding company, the technical experience referred to in clause 2.1.1 and 2.1.2 above as the case may be shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in clause 2.1.1 and 2.1.2 above as the case may be shall be of that subsidiary company only (i.e. excluding its holding company).
2.1.3 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder OR Parent Company / Collaborator(s)/ Subsidiary (meeting para 1.1.1, Annexure-A to BDS) in support of meeting the requirement of para 1.1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : 0 0
1 Name of Contract Undertaken (for 345kV or above class Transformers) 0
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4 Voltage Level of Transformer erected under the Contract (Indicate 345kV or above class only)
5 No. of Transformer (s) under the contract (Indicate nos. of 345kV or above voltage class Transformer not less than 200MVA or equivalent capacity in banks of 3 single phase units each having capacity of at least 66.7 MVA, during the last Two (2) years)
6 MVA capacity of above mentioned 3-phase/1-phase units
7 Name of the substation or switchyard
8 No. of years, the above Transformer are in operation as on the date of bid opening. (Originally Scheduled)
9 Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
10 Details of documents uploaded in support of the above stated experience
Format for the Bidder in support of meeting the requirement of para 1.1.2, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
a Name of the Bidder
b Whether Bidder/Manufaturer established production line in India for 345kV or above class transformer
c Name of the Parent Company/Collaborator for the 345kV Transformer {The qualifying data for the parent company or collaborator for the equipment is furnished in Format-A above)
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 Indicate details below in case Contract executed for Transformer
(i) Voltage Level of Transformer erected under the Contract (Indicate 220kV or above class only)
(ii) No. of Transformer (s) under the contract (Indicate nos. of 220kV or above voltage class Transformer only)
(iii) Name of the substation or switchyard
(iv) No. of years, the above Transformer are in operation as on the date of bid opening.
(v) Scope of work involved under the Contract
(Tick whichever is/are applicable)
of Transformer of Transformer of Transformer
5 Whether parent company / collaborator(s) meets the technical experience criteria stipulated at 2.1.1 , and the details of which is mentioned at Format-A above. (Choose whichever is applicable from the drop down menu) Yes
6 Whether legally enforceable undertaking jointly by Bidder and the parent company / collaborator(s) (as per enclosed format in Section-VI: Sample forms and Procedures of the bidding documents) is furnished along with the bid. (Choose whichever is applicable from the drop down menu)
7 Confirmation letter from the Parent Company / Collaborator along with the bid stating that Parent Company / Collaborator shall furnish performance guarantee, in addition to contract performance guarantee to be submitted by the bidder, for an amount of 10% of the cost of equipment(s). (Choose whichever is applicable from the drop down menu)
8 Details of documents uploaded in support of the above stated experience
3.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 1.2 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive b) Minimum Average Annual Turnover* (MAAT) for best three years i.e. 36 months out of last five financial years of the bidder should be INR 1075.90 million. * Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income”. c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than INR 179.32 million. Note 1:- In case bidder is a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in clause 3.0 above shall be that of subsidiary company only (i.e. excluding its holding company).
Note 2:- Relaxation for Start-Ups^/ MSEs Start-Ups^/MSEs, meeting the specified requirements at Para 3.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 3.0 (b) & 3.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
4.0 Financial Qualification Data: 2 or more
Name of the Bidder 0
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
For the FY of immediately preceding the date of submission of bid.
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Millions) Details of documentary evidence submitted in support of Qualification Data
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV 0
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV 0
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Average Annual Turnover for best Three Years is
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively requirements stipulated at clauses 3.0 (b) & 3.0 (c) above. The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 3.0 (b) & (c) above.
However, for a JV to be qualified, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 3.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum criteria given at clause 3.0 (b) & (c) and 100 % of the criteria given above at clause 2.1 iii. The other partner(s) shall meet not less than 25% of the criteria given at clause 3.0 (b) & (c) above and 100 % of the criteria given above at clause 2.1 or 2.2 Failure to comply with this requirement will result in rejection of the joint venture’s bid.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents
Audited balance sheet and income statements for the last five years as per the following:
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-3(QR)
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Qualifying Requirement Data)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-4
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : -- Printed Name :
Place : Designation :
country. country. [Name of Countries], [Name of Countries],
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-4(A)
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-4(B)
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-5
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-5A
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder's Name and Address: To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
1 We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2 2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-5A
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-6
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-7
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Details of Alternative Bid)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
No Alternative Bid
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-9
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Work Completion Schedule)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and completion of works i.e., Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work- Activity Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Breakup of Completion Schedule in Months (Bidder must fill break-up Schedule)
1 Handing over of site to agency/ Mobilization at site
a Establishment of site office
b Kick off meeting
2 Completing statuory requirement of contract such as labour license, Insurance policies- Workmen Compensation Insurance Policy, Contractor All Risk Insurance Policy, etc
3 Sampling and source approval of construction materials including design mix for RCC concrete or as per BPS
4 Excavation of basement
5 RCC structure work below Plinth level
6 RCC structure work above Plinth level
7 All ancillary Civil works including Brick Work, Plaster, Painting, Doors, Windows, Flooring, Water Proofing, Building. Septic tank/ Soak pit, etc
8 Internal & External electrification
10 Fire Fighting work
11 Plumbing & Sewerage work
12 Road, drain, water harvesting, swimming pool work, etc
13 Development of Horticulture work
14 Balance- Internal, external finishing as per requirement of site
15 Handing/ taking over of facilities including submission of "As BUILT DRAWING" and relevant NOCs (if required)
Date : -- Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-10
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Guarantee Declaration)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Dear Sir, We declare that the ratings, performance figures and availability of the system furnished by us for subject Package covered under this specification are guaranteed by us. We further declare that in the event of any deficiencies in meeting the guarantees in respect of the characteristics mentioned below as established after conducting the factory test, you may at your discretion, reject or accept the equipment after assessing the liquidated damages as specified in the relevant clauses of Bid document. We note that in case we take any deviation regarding the maximum losses, as mentioned above, anywhere in the bid including Attachment-6 (Alternative, Deviations and Exceptions to Provisions), our bid shall be considered non –responsive in line with ITB clause 24.1(b) as modified in Section BDS.
Date -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-11
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation*
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : -- Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-11
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Ram Lal Power Grid Corporation of India Ltd.,
Address : G5 Northern Region-I, Reagional Headquarter
Gurgaon SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-11
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region-I, Reagional Headquarter
SCO Bay No. 5 to 10, Sector- 16 A
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) ATTACHMENT-12
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
0 Faridabad-121002
We hereby furnish the relevant details pertaining to the price adjustment provisions for your specifications and documents . The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
PV Price Component
I. Supply and Placement of Reinforcement Steel:
i) A- WPI-HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Baic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
i) A- WPI-HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) B-WPI-Cement,Lime and Plaster 0.3 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in
C-WPI-Cutting ,Shaping and finishing Stone 0.2 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
iii) LabourL= 0.1 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Prices are firm & Fixed
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-13
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Declaration regarding Social Accountability)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-14
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Integrity Pact is annexed herewith this Volume.
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai,New Delhi – 110016 hereinafter referred to as
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind Package and Specification Number NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-15
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment. Yes
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-16
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Additional Information)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder) 0
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
5.0 Details of Provident Fund Code Number of the Bidder [ref. ITB9.3(q)]
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-17
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 B9, Qutab Institutional Area, Katwaria Sarai
0 New Delhi-110016
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-17
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. B9, Qutab Institutional Area, Katwaria Sarai
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-17
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract & Materials
Name : Power Grid Corporation of India Ltd.,
Address : B9, Qutab Institutional Area, Katwaria Sarai
New Delhi-110016
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-18
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Safety Pact is attached herewith this Volume
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Safety Pact
1. The requisite format of Safety Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other six pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (s).
Between #REF! #REF!
Power Grid Corporation of India Limited #REF! #REF!
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as #REF! #REF!
"POWERGRID", #REF! #REF!
0 1 having its Registered Office at ,
having its Registered Office at ,, 1 AND
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind Specification Number:NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702)
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 1 of 6
POWERGRID values full compliance with all relevant laws and regulations and the principles of Safety, Health& Environment in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder / Contractor enter into this agreement called “Safety Pact” which will form part of the Bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
POWERGRID commits itself to take all measures necessary to prevent accidents duringConstruction and Operation of the Transmission Assets and to observe the following:
1. POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
2. POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
3. POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
4. POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time.
5. POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
6. POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
7. POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
8. POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
9. POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 2 of 6
10. POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
Section II – Commitments of the Bidder / Contractor:
The Bidder / Contractor commits himself to take all measures necessary to prevent / minimise accidents at their construction / erection sites and to observe the following:
1. The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by thembyproviding safe methods of work, working conditions and Tools & Plants for human safety.
2. The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
3. The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
4. The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
5. The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of theirSub-contractors for safety awareness during construction works being executed by them.
6. The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
7. The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
8. The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 3 of 6
9. The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
10. The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at heightand also medically fitfor work at height are deployed for work at height in the Projects executed by them.
11. The Bidder / Contractor shall ensure daily before starting the work thattheir site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
12. The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
13. The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
14. The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / supportshall be provided to the victims / injured till they are completely fit to return to work.
15. The Bidder / Contractorshall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
16. The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
17. The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 4 of 6
18. The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
19. The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
20. The Bidder / Contractor accepts the provisions regarding safety, including payment of compensation to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
Section III – Equal treatment to all Bidders / Contractors:
1. POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
2. POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
Section IV – Pact Duration:
This Pact begins when both parties have legally signed it. It expires for the successful Bidder / Contractor after closure of the contract and, for all other Bidders, after the contract has been awarded.
Section V – Other Provisions:
1. This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
2. Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
3. If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
4. Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
5. Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 5 of 6
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Safety Pact Page 6 of 6
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Attachment-19
Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind
Bidder’s Name and Address To:
Contract & Materials
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 Northern Region-I, Reagional Headquarter
0 SCO Bay No. 5 to 10, Sector- 16 A
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : -- Printed Name :
Place : Designation :
Specification No. :NR1/NT/W-CIVIL/DOM/I00/26/13920 (RFX- 5002005702) Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : -- 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract & Materials 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Northern Region-I, Reagional Headquarter 11 eleven 11 th 11 November
SCO Bay No. 5 to 10, Sector- 16 A 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Construction of additional 03 nos. residential quarters at 400/220 kV Sub-station, Jind 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 21 of ITB, Section-II." Please note that if bid validity is less than 06 (six) months, your bid may be rejected
(b) Attachment 2() : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
*Further the requisite deed of Joint Undertaking as per stipulated qualification requirement in Annexure-A (BDS) has also been furnished as per your format.
* Delete if not applicable
(c) Attachment 3() : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 3(QR)]. 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 #REF! Not Applicable 24 th
(d) Attachment 4() : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5() : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A() : Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises. 26 th
(g) Attachment 6() : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7() : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8() : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9() : Work Completion Schedule. 30 th
(k) Attachment 10() : Guarantee Declaration. 31 st
(l) Attachment 11() : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12() : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13() : Declaration regarding Social Accountability.
(o) Attachment 14() : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15() : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16() : Additional Information.
(r) Attachment 17() : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18() : Safety Pact
(t) Attachment 19() : Declaration.
(u) Attachment 20() : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21() : Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order December 2018, if applicable
(w) Attachment 22() : Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, and MoP Order December 2018, if applicable
(x) Attachment 23() : Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(d) GCC 55 Terms of Payment
(e) GCC 8.3 Performance Security
(f) GCC 6 Taxes and Duties
(g) GCC 38 Liquidated Damages for Delay by Contractor
(h) GCC 40 Defect Liability
(i) GCC 39 Guarantee
(j) GCC 20.5 Patent & Royalties
(k) GCC 61 Limitation of Liability
(l) GCC 57 Settlement of Disputes
(m) GCC 59 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. 2
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of 0
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_schedule.xlsx
xlsx • 1.30 MB
01-Section - I IFB SSTE Vol-I.docx
docx • 0.05 MB
02 Section - II ITB SSTE civil(Feb 2019).docx
docx • 0.11 MB
03-Section - III_BDS.docx
docx • 0.06 MB
04-Annexure-A(BDS)-QR.docx
docx • 0.02 MB
07-Appendix -I to SCC.doc
doc • 0.17 MB
07_Section -IV General Conditions of Contract (GCC).pdf
pdf • 0.76 MB
08-Appendix-II SCC.docx
docx • 0.04 MB
08_Section-V-Special Conditions of Contract (SCC).doc
doc • 0.23 MB
09-Section - VI Forms and Proceedures Vol-I.doc
doc • 0.32 MB
Thumbs.db
db • 0.02 MB
~$ Section - II ITB SSTE civil(Feb 2019).docx
docx • 0.00 MB
~$-GCC-civil works(Feb 2019).doc
doc • 0.00 MB
~$-Section - I IFB SSTE Vol-I.docx
docx • 0.00 MB
~$-Section - III_BDS.docx
docx • 0.00 MB
~$-Section - VI Forms and Proceedures Vol-I.doc
doc • 0.00 MB
Annexure_III_Scop of work.pdf
pdf • 0.89 MB
Annexure_II_SFQP Civil Works.pdf
pdf • 2.86 MB
Annexure_I_A_TS Electrical (3).pdf
pdf • 0.75 MB
Annexure_I_B_TS Civil.pdf
pdf • 0.41 MB
B2 type Quarter Drawing.pdf
pdf • 1.29 MB
C type Quarter Drawing.pdf
pdf • 1.24 MB
01_First Envelope and Bid Form.xlsx
xlsx • 1.43 MB
03_Attachment 12-KMP Declaration.doc
doc • 0.04 MB
04-Attachment 14-Integrity Pact.doc
doc • 0.07 MB
04-Attachment-21- Affidavit for Self Certifictaion.docx
docx • 0.02 MB
05-Attachment 18-Safety Pact.docx
docx • 0.05 MB
06-Attachment -24_Declaration regarding events encountered.docx
docx • 0.04 MB
07 Attachment 21-Affidavit for correctness of information.docx
docx • 0.02 MB
08-Legends.pdf
pdf • 0.03 MB
Attachment-11_Self certification DMISP.docx
docx • 0.03 MB
Attachment-31-Declaration by the bidder for ‘Code of Integrity for Public procurement’.docx
docx • 0.02 MB
Thumbs_1.db
db • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .