| Sl No | Description | Qty | Unit | P.K. Electricals L2 | CHANDERA BUILDERS L1 |
|---|---|---|---|---|---|
| 1.01 | Dismantling of electric connection from panel and motor, pump and motor from coupling, motor and pump removed from base frame. Removing suction and delivery lines, sluice valves, NRV, old damaged MS base frame from foundation etc by electric cutter, gas cutter, tools and tackles, manual labour and shifting the same to JE store. | 1 | Job | 11,800 ₹13,924 | 11,640 ₹13,735.2 Lowest |
| 1.02 | Breaking of existing RCC foundation by manual means including manual tools or electric demolition hammer as per site requirement including digging up to 50 cm for laying the new foundation and disposing off malba as per instructions from engineer – in – charge within 1 km of radius from site. | 1 | Job | 6,800 ₹8,024 | 6,470 ₹7,634.6 Lowest |
| 1.03 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump including form work and finishing etc as required as per site requirement. | 1 | Job | 27,900 ₹32,922 | 27,450 ₹32,391 Lowest |
| 1.04 | Supply of Pump Capacity 340 MQPH at 42 Meter Head, HS Casing Centrifugal Clear Water Pump Model UP 150/38 A or equivalent 200 X 150 MM, 1475 RPM, 86% Efficiency, With CI Impeller, EN-8 Shaft & Gland packed, Coupled With Electric Motor 75 HP TEFC. IE2, 415V 3PH, Mounted On Common Base frame / Coupling & Guard complete.Pump Make: KBL/M&P/DJB Approved. ,Motor Make: Kirloskar/Crompton/DJB Approved. | 1 | No. | 6,76,800 ₹7,98,624 | 6,76,300 ₹7,98,034 Lowest |
| 1.05 | Supply of M.S. Pipe 200 mm, 6 mm thick make Jindal / DJB approved make | 2 | Mtr | 3,000 ₹3,540 | 2,740 ₹3,233.2 Lowest |
| 1.06 | Supply of M.s. pipe 150 mm, 6 mm thick. Make: Jindal / DJB approved make | 2 | Mtr. | 2,900 ₹3,422 | 2,560 ₹3,020.8 Lowest |
| 1.07 | Supply of M.S. Flange 200 mm dia heavy duty holes as per site requirement. Make: ISI/ Jindal/ DJB approved make | 4 | Nos. | 5,800 ₹6,844 | 5,200 ₹6,136 Lowest |
| 1.08 | Fabrication and supply of suitable reducer as per site requirement for 150 mm to 200 mm | 1 | No. | 1,700 ₹2,006 | 1,480 ₹1,746.4 Lowest |
| 1.09 | S/o of 150 mm CI double flanged swing type non return valve as per IS:5312 PN 1.0 CI body door / bronze to rubber ring / SS 410 twin pin. Make : Kirloskar/DJB Approved. | 2 | Nos. | 53,000 ₹62,540 | 49,960 ₹58,952.8 Lowest |
| 1.10 | Supply of 200 mm bend of 6mm thickness | 1 | No. | 3,200 ₹3,776 | 2,920 ₹3,445.6 Lowest |
Tender Value
Refer Docs
EMD Value
₹20,200
Closing Date
18 Aug 2026, 11:15 amClosed
Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
SITC of 75 HP pumpset by Replacement of existing 40 HP pump set No. 09 for Budh Vihar area at Old Avantika Booster.
2026_DJB_296775_1
NIT No.09 /EE(EnM)M-8/2026-27 Item 22
Open Tender
Civil Works
Works
30 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹20,200
Yes
24 Aug 2026
10 Aug 2026
18 Aug 2026
10 Aug 2026
18 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling of electric connection from panel and motor, pump and motor from coupling, motor and pump removed from base frame. Removing suction and delivery lines, sluice valves, NRV, old damaged MS base frame from foundation etc by electric cutter, gas cutter, tools and tackles, manual labour and shifting the same to JE store. | 1 | Job | 80 | ₹80 |
| 1.02 | Breaking of existing RCC foundation by manual means including manual tools or electric demolition hammer as per site requirement including digging up to 50 cm for laying the new foundation and disposing off malba as per instructions from engineer – in – charge within 1 km of radius from site. | 1 | Job | 80 | ₹80 |
| 1.03 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump including form work and finishing etc as required as per site requirement. | 1 | Job | - | - |
| 1.04 | Supply of Pump Capacity 340 MQPH at 42 Meter Head, HS Casing Centrifugal Clear Water Pump Model UP 150/38 A or equivalent 200 X 150 MM, 1475 RPM, 86% Efficiency, With CI Impeller, EN-8 Shaft & Gland packed, Coupled With Electric Motor 75 HP TEFC. IE2, 415V 3PH, Mounted On Common Base frame / Coupling & Guard complete.Pump Make: KBL/M&P/DJB Approved. ,Motor Make: Kirloskar/Crompton/DJB Approved. | 1 | No. | - | - |
| 1.05 | Supply of M.S. Pipe 200 mm, 6 mm thick make Jindal / DJB approved make | 2 | Mtr | - | - |
| 1.06 | Supply of M.s. pipe 150 mm, 6 mm thick. Make: Jindal / DJB approved make | 2 | Mtr. | - | - |
| 1.07 | Supply of M.S. Flange 200 mm dia heavy duty holes as per site requirement. Make: ISI/ Jindal/ DJB approved make | 4 | Nos. | - | - |
| 1.08 | Fabrication and supply of suitable reducer as per site requirement for 150 mm to 200 mm | 1 | No. | - | - |
| 1.09 | S/o of 150 mm CI double flanged swing type non return valve as per IS:5312 PN 1.0 CI body door / bronze to rubber ring / SS 410 twin pin. Make : Kirloskar/DJB Approved. | 2 | Nos. | - | - |
| 1.1 | Supply of 200 mm bend of 6mm thickness | 1 | No. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_395158.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .