Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹11.0 L (9.26%)Admitted-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹1.3 Cr+₹11.0 L (9.26%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Leo Air and Power Solution pvt Ltd. L2 | Commercial Traders L1 |
|---|---|---|---|---|---|
| 1.00 | Taking shutdown of electric supply, disconnecting and taking down of four pole structure / HT load break switches and making site neat and clean complete all as specified and directed.
Note : HT load break switch to be deposited to the MES store/yard carefully by Hydra or crane etc and rate for the same is including in quoted rate. | 4 | Each | 5,000 ₹20,000 Lowest | 5,000 ₹20,000 Lowest |
| 2.00 | Supply, installation, testing & commissioning of 11 KV outdoor type(IP-54) one side-extensible 5-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 2 nos. fixed type motorised Load break switch for incoming and 3 nos. fixed type motorized Vacuum Circuit Breaker for outgoing. All live parts, bus bars, LBSs & VCBs connections of RMU should be enclosed in tank & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown without sending the RMU to OEM factory. RMU should be complete with all accessories such as end Terminal kits (indoor/outdoor) heat shrink of suitable size for Cable, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar .The unit shall include the following with all necessary standard fitting required at site.
Make of RMU: ABB, SIEMENS, SCHNEIDER INFRA.
Note : 1. The RMU shall be designed and manufacturered by OEM only not by their franchise or authorised partners. 2. OEM will stand warranty of 05 years for complete design, supply and inspection upto site service support. | 1 | Each Job | 15,27,912 ₹15,27,912 | 15,20,000 ₹15,20,000 Lowest |
| 2.01Each VACUM CIRCUIT BREAKER of RMUs 630A VCB module for making & breaking of fault current alongwith Earth Swicth of full making capacity-1 Nos. Motor operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5KA VCB must confirm operating sequence O-0.3sec-CO-3Min-CO Power frequency withstand voltage - 38KV Impulse withstand voltage - 95KV Minimum Mechanical Operation - 10000 nos. Front cover mechanism - IP2X Electrical and mechanical interlock to keep always one incomer ON & another Incomer OFF. Green(ON)/Red(OFF) push buttons to operated VCB. 3O/C + 1E/F Self powered numerical protection relay with Low and High set for Over current and Earth Fault. Ammeter with Selector Switch RMU Gas Tank and cable chamber should be tested for an internal arc fault of 21kA for 1 sec with AFLR classification Resin cast ring core protection CT on cables 100-50/1A, 5P10, 2.5 VA - 3 Nos Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes should be Arc Proof interlocked with respective Earthing Switches. | |||||
| 3.00 | All as per ser item No. 2 but supply,installation,testing & commissioning of 11 KV outdoor type one side-extensible 6-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 2 nos. fixed type motorized Load break switch for incoming and 4 nos. fixed type motorized Vacuum Circuit Breaker for outgoing. | 1 | Each Job | 18,66,264 ₹18,66,264 Lowest | 19,50,000 ₹19,50,000 |
| 4.00 | All as per ser item No. 2 but supply,installation,testing & commissioning of 11 KV outdoor type one side-extensible 3-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 2 nos. fixed type motorized Load break switch for incoming and 1 no. fixed type motorized Vacuum Circuit Breaker for outgoing. | 3 | Each Job | 7,54,704 ₹22,64,112 | 7,05,238 ₹21,15,714 Lowest |
| 5.00 | All as per ser item No. 2 but supply,installation,testing & commissioning of 11 KV outdoor type one side-extensible 1-way Ring Main Unit (Incoming cum outgoing type) floor mounted with internal copper bus bars, consisting of 1 no. fixed type motorized Vacuum Circuit Breaker & 1 no. direct cable module. | 2 | Each Job | 5,07,108 ₹10,14,216 | 4,65,000 ₹9,30,000 Lowest |
| 6.00 | Supply, installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 ph, 4 wire, 50 Hz, present energy efficient level - 2 confirming to relevant IS, IS:2026 (ISI maked and BEE Approved), capacity 500 KVA CRGO with M4 grade, core type, double copper wound, oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side( LV) in accordance with vector group Dyn- 11 with neutral brought out on secondary side (LV) and having tappings +/- 5% at the step of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 40 degree C in oil and 45 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C complete all as specified & directed and shall also comprises of the following:-
(a) 01 cable box chamber on HV side ( primary) consisting of 03 Nos poreclin bushing with copper bus bar complete with nuts and washers, with 01 No cable gland suitable for XLPE HT cable.
(b) 01 cable box chamber on LV side ( secondary) consisting of 04 Nos poreclin bushing with copper bus bar complete with nuts and washers, with 02 No cable gland suitable for XLPE LT cable.
(c ) Oil conservator tank with filter type drain plug and oil level gauge.
(d) Dehydrating brether with first fill of silica gel.
(e) Explosive vent, thermameter pocket on tank cover, oil level guage, oil drain filter valve, lifting hucks, oil filling hole with cap/ plug with connection plate, Air release valve plug at four Nos plate, soil cast steel detachable rollers complete.
(f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device. | 1 | Each Job | 16,88,544 ₹16,88,544 | 15,90,000 ₹15,90,000 Lowest |
| 6.01(g) 02 Nos earthing terminals on tank cover to facilitate fixing of 32 x 6 mm copper earth strip for earthing of body. Rating plate and terminal marking plate. (h) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for natural. (j) First fill of new and unused transformer oil, as per relevant IS, filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes (make: savita / Power Oil). (k) Providing adequate size and Numbers of channels, embedded in flour, for movement of transformers. (l) Buchholtz relay complete with electric connection up to relay - 01 No (m) Provn of new platform with suitable working space for inspection as per manufacturer specification and drawing having load bearing power more than 4.5 ton or suitable for 500 KVA transformer including plastering & whitewash. This also including demolition of existing platform, returning, filling, leveling and ramming and removal of extra material. Note:- (i) The transformer should be designed and manufactured by Original Equipment Manufacturer (OEM ) only and drawing shall approved by GE before manufacturing of the same. (ii) OEM will stand warranty of 02 years for complete design, supply and inspection upto site service support. | |||||
| 7.00 | Supply, installation, testing and commissioning factory made (CPRI approved) LT panel, outdoor type, made out of 3.15 mm thick CRCA sheet, powder coated, weather, dust & vermin proof, front and back openable door, with suitable size angle iron frame and locking arrangement, airvent, including suitable working space in bus bar chamber, suitable for 3 phase 4 wire system, 415V, 50 Hz, AC supply, including minimum 1.5 times of main incomer rating aluminium bus bar with PVC sleeves/ tape RYB colours for phases identification, including all bus bar shall be extend upto cable box chamber fixed on fiber insulation for RYB & neutral to all out going cable and fixed on raised PCC platform with PCC 1:2:4, with control wiring with suitable copper wire, cable gland & lugs etc and comprising the following:- (Loc - Family Qtr)
(i) MCCB 4 Pole 415 volts AC 50 Hz 630 Amps, 50 kA - 01 No (Incomer)
(ii) 1 No. change over switch ON load 630 Amps, 4 pole, 415 Volts.
(ii) Digital and programmable multifunction meter with all parameter with suitable capacity of 03 Nos CT's - 01 No
(iii) LED indication lamp with toggle switch RYB for phase indication- 01 Set of three
(iv) MCCB 4 Pole 415 volts AC 50 Hz 400 Amps, 36 kA - 02 Nos (Outgoing)
(v) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps, 36 kA - 01 Nos (Outgoing)
Note:- (i) OEM will stand warranty of 02 years for complete design, supply and inspection upto site service support. (ii) All MCCBs shall be adjustable type with thermal magnetic release, Ics = 100% Icu & Icw for 1 sec. | 1 | Each Job | 2,99,664 ₹2,99,664 | 2,90,962 ₹2,90,962 Lowest |
| 8.00 | Supply, laying, jointing, testing and commissioning new XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sqmm x 3.5 Core two run in trench/ pipe/ panel incl cable connection & cable gland complete all as specified and directed. | 30 | RM | 2,433 ₹72,990 | 2,305 ₹69,150 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
14 Sept 2026, 6:00 pmClosed
CWE NEW DELHI
CWE NEW DELHI
ADD ALTN OF HT INFRASTRUCTURE OF AHRR UNDER GE E M R R HOSP DELHI CANTT 10
2026_MES_771057_3
CWE-ND/T-18/2026-27
Open Tender
Civil Works
Item Rate
180 days
GER R HOSPITAL
ASN PER TENDER cat b(ii) class B
9 documents required · 9 mandatory
₹1,000
GE R R HOSPITAL
₹2.2 L
Yes
17 Sept 2026
25 Aug 2026
16 Sept 2026
25 Aug 2026
14 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking shutdown of electric supply, disconnecting and taking down of four pole structure / HT load break switches and making site neat and clean complete all as specified and directed.
Note : HT load break switch to be deposited to the MES store/yard carefully by Hydra or crane etc and rate for the same is including in quoted rate. | - | Each | 1.25 | - |
| 2Supply, installation, testing & commissioning of 11 KV outdoor type(IP-54) one side-extensible 5-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 2 nos. fixed type motorised Load break switch for incoming and 3 nos. fixed type motorized Vacuum Circuit Breaker for outgoing. All live parts, bus bars, LBSs & VCBs connections of RMU should be enclosed in tank & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200.The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown without sending the RMU to OEM factory. RMU should be complete with all accessories such as end Terminal kits (indoor/outdoor) heat shrink of suitable size for Cable, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external bus bar .The unit shall include the following with all necessary standard fitting required at site. Make of RMU: ABB, SIEMENS, SCHNEIDER INFRA. Note : 1. The RMU shall be designed and manufacturered by OEM only not by their franchise or authorised partners. 2. OEM will stand warranty of 05 years for complete design, supply and inspection upto site service support. | |||||
| 2.01 | Each VACUM CIRCUIT BREAKER of RMUs
630A VCB module for making & breaking of fault current alongwith Earth Swicth of full making capacity-1 Nos.
Motor operated 630 A Vacuum circuit breaker having spring stored mechanism.
Three position disconnector/earthing switch downstream vacuum circuit-breaker.
Three position single spring mechanism for disconnector/earthing switch
“Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings.
Short time breaking current - 21KA/ 3 sec
Making Capacity - 52.5KA
VCB must confirm operating sequence O-0.3sec-CO-3Min-CO
Power frequency withstand voltage - 38KV
Impulse withstand voltage - 95KV
Minimum Mechanical Operation - 10000 nos.
Front cover mechanism - IP2X
Electrical and mechanical interlock to keep always one incomer ON & another Incomer OFF.
Green(ON)/Red(OFF) push buttons to operated VCB.
3O/C + 1E/F Self powered numerical protection relay with Low and High set for Over current and Earth Fault.
Ammeter with Selector Switch
RMU Gas Tank and cable chamber should be tested for an internal arc fault of 21kA for 1 sec with AFLR classification
Resin cast ring core protection CT on cables 100-50/1A, 5P10, 2.5 VA - 3 Nos
Mechanical ON/OFF/EARTH/Spring charge Indication
Cable boxes should be Arc Proof interlocked with respective Earthing Switches. | - | - | - | - |
| 3 | All as per ser item No. 2 but supply,installation,testing & commissioning of 11 KV outdoor type one side-extensible 6-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 2 nos. fixed type motorized Load break switch for incoming and 4 nos. fixed type motorized Vacuum Circuit Breaker for outgoing. | - | Each Job | 100 | - |
| 4 | All as per ser item No. 2 but supply,installation,testing & commissioning of 11 KV outdoor type one side-extensible 3-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 2 nos. fixed type motorized Load break switch for incoming and 1 no. fixed type motorized Vacuum Circuit Breaker for outgoing. | - | Each Job | 53 | - |
| 5 | All as per ser item No. 2 but supply,installation,testing & commissioning of 11 KV outdoor type one side-extensible 1-way Ring Main Unit (Incoming cum outgoing type) floor mounted with internal copper bus bars, consisting of 1 no. fixed type motorized Vacuum Circuit Breaker & 1 no. direct cable module. | - | Each Job | 10 | - |
| 6 | Supply, installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 ph, 4 wire, 50 Hz, present energy efficient level - 2 confirming to relevant IS, IS:2026 (ISI maked and BEE Approved), capacity 500 KVA CRGO with M4 grade, core type, double copper wound, oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side( LV) in accordance with vector group Dyn- 11 with neutral brought out on secondary side (LV) and having tappings +/- 5% at the step of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 40 degree C in oil and 45 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C complete all as specified & directed and shall also comprises of the following:-
(a) 01 cable box chamber on HV side ( primary) consisting of 03 Nos poreclin bushing with copper bus bar complete with nuts and washers, with 01 No cable gland suitable for XLPE HT cable.
(b) 01 cable box chamber on LV side ( secondary) consisting of 04 Nos poreclin bushing with copper bus bar complete with nuts and washers, with 02 No cable gland suitable for XLPE LT cable.
(c ) Oil conservator tank with filter type drain plug and oil level gauge.
(d) Dehydrating brether with first fill of silica gel.
(e) Explosive vent, thermameter pocket on tank cover, oil level guage, oil drain filter valve, lifting hucks, oil filling hole with cap/ plug with connection plate, Air release valve plug at four Nos plate, soil cast steel detachable rollers complete.
(f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device. | - | Each Job | 11 | - |
| 6.01 | (g) 02 Nos earthing terminals on tank cover to facilitate fixing of 32 x 6 mm copper earth strip for earthing of body. Rating plate and terminal marking plate.
(h) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for natural.
(j) First fill of new and unused transformer oil, as per relevant IS, filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes (make: savita / Power Oil).
(k) Providing adequate size and Numbers of channels, embedded in flour, for movement of transformers.
(l) Buchholtz relay complete with electric connection up to relay - 01 No
(m) Provn of new platform with suitable working space for inspection as per manufacturer specification and drawing having load bearing power more than 4.5 ton or suitable for 500 KVA transformer including plastering & whitewash. This also including demolition of existing platform, returning, filling, leveling and ramming and removal of extra material.
Note:- (i) The transformer should be designed and manufactured by Original Equipment Manufacturer (OEM ) only and drawing shall approved by GE before manufacturing of the same.
(ii) OEM will stand warranty of 02 years for complete design, supply and inspection upto site service support. | - | - | - | - |
| 7 | Supply, installation, testing and commissioning factory made (CPRI approved) LT panel, outdoor type, made out of 3.15 mm thick CRCA sheet, powder coated, weather, dust & vermin proof, front and back openable door, with suitable size angle iron frame and locking arrangement, airvent, including suitable working space in bus bar chamber, suitable for 3 phase 4 wire system, 415V, 50 Hz, AC supply, including minimum 1.5 times of main incomer rating aluminium bus bar with PVC sleeves/ tape RYB colours for phases identification, including all bus bar shall be extend upto cable box chamber fixed on fiber insulation for RYB & neutral to all out going cable and fixed on raised PCC platform with PCC 1:2:4, with control wiring with suitable copper wire, cable gland & lugs etc and comprising the following:- (Loc - Family Qtr)
(i) MCCB 4 Pole 415 volts AC 50 Hz 630 Amps, 50 kA - 01 No (Incomer)
(ii) 1 No. change over switch ON load 630 Amps, 4 pole, 415 Volts.
(ii) Digital and programmable multifunction meter with all parameter with suitable capacity of 03 Nos CT's - 01 No
(iii) LED indication lamp with toggle switch RYB for phase indication- 01 Set of three
(iv) MCCB 4 Pole 415 volts AC 50 Hz 400 Amps, 36 kA - 02 Nos (Outgoing)
(v) MCCB 4 Pole 415 volts AC 50 Hz 250 Amps, 36 kA - 01 Nos (Outgoing)
Note:- (i) OEM will stand warranty of 02 years for complete design, supply and inspection upto site service support. (ii) All MCCBs shall be adjustable type with thermal magnetic release, Ics = 100% Icu & Icw for 1 sec. | - | Each Job | 1.25 | - |
| 8Supply, laying, jointing, testing and commissioning new XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sqmm x 3.5 Core two run in trench/ pipe/ panel incl cable connection & cable gland complete all as specified and directed. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_881070.xls
BOQ • 0.32 MB
TENDER18.pdf
Tender Documents • 1.18 MB
corr2makelist.pdf
PDF • 1.64 MB
corr1.pdf
PDF • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .