Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹34.8 L
EMD Value
₹69,500
Closing Date
18 Dec 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
TECHNICAL
12 conditions · 1 needing a document upload
Clause Regarding GST: (a) All the Bidders/tenderers should ensure that they are GST Compliant and their quoted tax Structure are as per GST LAW.(b) Tenderer Should Furnish their GSTIN numbers representing the States in Which they are registered GST, along with address of Registered Office.(c)The Contract is under GST Act and rules as applicable time to time.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
37 conditions · 8 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Improvement of illumination with provision of HM Tower after dismantling of old Lattice type tower at TSK, MXN,DBRT & NLP.
LV-T-14-TSK-922~NFR
LV-T-14-TSK-922
Open
Works - General
8 Months
Tinsukia, Assam
₹0
₹69,500
18 Dec 2025
26 Nov 2025
4 Dec 2025
13 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 34,75,217 | ||
| — | 10.00 | — | — | ||
| Dismantalling of old Lattice fabricated Tower/High mast tower and deposition of all materials to Concerned Power House in challan. The tower to be dismantalled part wise with help of welding/gas cutting and suitable Machinery(Hydra Crane) Proper Safety precaution to be observed during dismantallling as per direction of Engineer incharge at Site. | — | — | — | 2,60,050 | |
| — | 3.00 | — | — | ||
| Supply, fitting, fixing of 200 Amps outdoor type cable junction box, angle frame mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 200 Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). | — | — | — | 26,817 | |
| — | 6.00 | — | — | ||
| Supply, installation , testing and commissioning of 12 Mtrs high mast tower hot dip galvanized as per IS 875(construction as per BS EN 10025 - 1993 or equivalant IS) with lantern carriage for 8 Nos of Nos of Light, pulley and cables with 8 Nos 150 W LED Flood Light with secondary lens for illumination . The mast shall also include accessories for highmast including headframe,steel wire rope 6mmdia (7/19 construction),trailling cable,double drum winch,galvanised lantern carriage arrangement suitable for 8 Nos Of Luminarie. The structure shall be of 12 Mtr height in two sections, hot dip galvansied both inside and outside (conforming to IS4759- 1984,IS2629-1985, IS2633-1972) and suitable for wind speed as per IS875 Part III , including base plate of size 545X545X20mm, Lightning protection final with GI single spike of suitable length, provision for 3 nos of earthing terminals at base of mast, Twin dome LED avaiation obstruction light at top of mast, 06 nos of 900mm/20mm(min.) size steel E 6.8 grade foundation bolts and Anchor plate of 445 PCD . The Construction of Foundation is included in scope of work as per manufacturers recomendation. The foudation should be as per Approved Drawing of manufacturer.The Mast shall also have raising and lowering system, head frame, hot dip galvanised steel lantern carrige (using 50mm dia B class GI pipe) suitable for fixing 8 nos of LED high mast luminaires symmetrically, trailing cable of 24Amp rating EPR insulated and PVC sheathed 5core X 2.5 sq.mm copper conductor cable and other wiring materials for luminaires, integral power tool (415V, 3phase, 1HP - 2mtr per minute single speed motor reversible) installation inside the base compartment, 2 nos of continuous 6mm stainless steel wire ropes(7/19 construction), double drum winch (manual and electrical both) as per IS 807, Feeder type control panel for operation of luminaires with astromical ON/OFF timers with suitable MCBs, contractors for automatic control of luminairs, power tool control and raise lower push button etc., complete as required. . The mast shall have thickness of 3 mm top & Bottom, No of faces: 12, Across face dia: Top-100 mm, Bottom-360 mm, Base plate: 545x 20 mm, PCD: 445 MM, Bolts: 06 Nos of 20x900 mm. 3 Nos earthing to be provided for the High Mast with 50 mm dia GI pipe, 3 Mtrs Long and 32x5 mm GI flat strip of required length. High mast Control Panel with astronomical time switch, Power Contactor, required MCB included in the scope of work. | — | — | — | 20,46,600 | |
| — | 250.00 | — | — | ||
| Supply, laying, connection , testing of 6 SQ mm 4 core PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 | — | — | — | 1,09,750 | |
| — | 750.00 | — | — | ||
| Supply, laying, connection with necessary cable lugs, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable Size : 25 SQ MM 4 Core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988 . Cable laying by excavation of earth depth 0.75 Mtrs. into breadth 0.508 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024. | — | — | — | 4,98,000 | |
| — | 150.00 | — | — | ||
| Boring of 2.6 mtr. underneth Road/Railway track with HDD Machine and laying of 150 mm dia HDPE pipe PN 8 for passing underground cable as per Direction of Engineer Incharge at Site.Supply of the HDPE pipe is included in the scope of this work. | — | — | — | 5,34,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .