| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹39.4 L+₹1.4 L (3.81%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹43.2 L+₹5.3 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 May 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/REPLACEMENT OF LT INFRASTRUCTURE UNSV STREET LIGHT, FLOOD LIGHT, HIGH MAST LIGHT, GATE LIGHT, FOCUS LIGHT AND SUMMER COOLING APPLIANCES IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2022_MES_520091_1
GE/EM/LKO/HOSP/T-14 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
240 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹98,000
Yes
30 Jun 2022
26 Apr 2022
1 Jun 2022
26 Apr 2022
30 May 2022
18 May 2022
Amount
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 01 above but of size 10 Sqmm 4 core
All as per item No 01 above but of size 16 Sqmm 4 core
All as per item No 01 above but of size 25 Sqmm 3.5 core
All as per item No 01 above but of size 35 Sqmm 3.5 core
All as per item No 01 above but of size 50 Sqmm 3.5 core
All as per item No 01 above but of size 70 sq mm 3.5 core
All as per item No 01 above but of size 95 Sqmm 3.5 core
All as per item No 01 above but of size120 Sqmm 3.5 core
All as per item No 01 above but of size 240 Sqmm 3.5 core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
M&L laying fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
S & F GI tubing 'Light' grade 40 MM for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes of following sizes, complete all as specified and directed.
All as per item No 17 above but size 50 mm bore dia
All as per item No 17 above but size 80 mm bore dia
Labour for taking out the unserviceable / faulty cable after meggering , finding the fault , cutting the cable , jointing with jointing kit using extra cable if required ,relaying of cables upto 300 sqmm 3.5 core ,connecting, rate included of excavation works, using old bricks complete all as specified and as directed. Note :, cable joints will be measured and paid seperatly under respectrive item of schedule.
Material & Labour for preparation of old painted surface of steel tubular pole 9 meter long above coping) and applying two coat of aluminium paint, making of strip of 300mm width (balck and yellow in alternate band) upto 1500 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in black colour background of 80 mm hight around the radius of pole and complete all as specified and directed.
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and directed.
M&L for old painted steel surface or iron surfaces of LT FPB of various size by scraping with steel wire brush/scrapper emery paper etc and applying one coat of synthatic enameled siemens grey/existing colour (painting shall be done by spray machine ) including hinge welding and fiting of new two number door for front and backside for thickness upto 3.15mm & size as per existing panel of the LT FBP door matching with the LT FBP including panel repair complete all as specified and directed.
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity upto 100 AMPS complete all as specified and directed.
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and directed.
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and directed.
MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and directed.
MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and directed.
Digital type Volt meter , 3 ph , class 1 including taking down unserviceable voltmeter, complete all as specified and directed.
Digital type Ammeter 3 ph , 5 Amps , class 1 including taking down unserviceable ammeter, complete all as specified and directed.
Indicator lamps (LED Type) including taking down unserviceable indicator lampsall, complete all as specified and directed.
S & F in rep MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with 'B curve, fixed in existing PVC box including connecting complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as in copping of poles complete all as specified and directed.
Disconnecting the LT cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5/4 core 10 to 16 sq mm, complete all as specified and directed.
All as per item No 37 above but size 25 to 50 Sqmm
All as per item No 37 above but size 70 to 120 Sqmm
All as per item No 37 above but size 150 to 185 Sqmm
All as per item No 37 above but size 240 to 300 Sqmm
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
S&F in repair MS Junction Box made of 1.6 mm thick MS sheet of size 300 x 200 x 150 mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bus bar 100 Amps, mounted on porcelain insulator including MCB SP 10Amp , 10 KA-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete including required size and length of copper conductor cable and making connections complete all as specified and directed.
S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed Make havells or equivalent complete all as specified and directed.
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed.
S & F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and directed.
Supply and fixing new generation ,energy saving ,environment friendly LED GATE LIGHT fitting,fully cast aluminium body finish with polyeurethene paint with acryilic window cover with B22 brass holder suitable for 15 to 20 watt led bulb as light sopurce including making connections complete all as specified and directed.
Supply and fixing new generation ,energy saving ,environment friendly POST TOP LANTERN fitting, aluminium spun landscape luminaires with high power LED 25 watt as light source including making connections complete all as specified and directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M&L Earthing complete with Copper earth Plate electrode 60x60cmx3.15mm thick, burried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, Including connected to copper strip 20x3mm lead (upto 7.5 Mtr) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion.ith salt to a packed thickness of 15 cm all around the plate, and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Dismantling and removing existing unsv street light/ flood light MH/HPSV fittings of any type and any capacity from street light poles any hieght and high mast light pole after disconnecteing of electrical connection complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings 35 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings 45 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings of 120 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply and Fixing, connecting and testing energy saving LED street light fittings of 90 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Fixing in replacement GI bracket for street light fittings fabricated with GI tubing 40mm dia 'light grade' 1.5m long and bending to angle of 120 degree including mild steel clamp of suitable size with two coat aluminium paint suitable for fixing on PCC/steel poles complete all as specified and directed.
Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 120 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 70 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Supply and Fixing, connecting and testing energy efficient LED flood light fittings of 150 Watt pressure die cast aluminium housing and IP66 protection including XLPE armoured cable 2 core 4 Sqmm up to 5 mtr from fitting to panel box with emitter complete all as specified and directed.
Lowering the high mast light from height of 16 to 25 mtr and repairs to the extent by removing connections from the system, checking of unserviceable spare parts and serviceable parts ,replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location and tesing complete all as specified and directed. Note : (a) Spares required for repair shall be measured and paid separately as supply only items here-in-after (b) The contractor shall provide all type and safety equipment & other tools required at site to electrician for maintenance of light (c) In case any accident/injury of any person deputed by contractor shall be held responsible for setting all claims/compensation. (d) all other item also included in the works which not catered in items
Supply only gear box as per existing size, capacity and make CROMPTON GREEVES
Supply only motor as per existing size,capacity and make CROMPTON GREEVES
Supply only controll switch as per existing size, capacity and make CROMPTON GREEVES
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 200 Watt pressure die cast aluminium housing and IP66 protection with complete all as specified and directed.
Material and Labour for servicing of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed. (a) Inspecting and checking the Indoor/outdoor units for noise free operation. (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower. (d) Greasing/Oiling of condenser fan motor and blower motor. (e) Checking for any refrigerant leakage by pressure testing and repair it. (f) Checking for serviceability of remote control unit NOTE - Sevicing of each AC should be done twice in a entire contract period.
All as per item No 69 above but 1.5/2.0 TR Window type AC.
Supply and fixed in repairs of starting capacitor of 80-100 /100/120/120/150 Mfd capacity in plastic / metal container complete all as specified and directed.
Supply and fixed in repairs of running capacitor 36 Mfd capacity in plastic container complete all as specified and directed.
Supply and fixed in repairs of running capacitor 50+2/50+6 Mfd capacity in plastic container complete all as specified and directed.
Supply and fixed in repairs starting relay for 1.5 TR /2 TR compressor complete all as specified and directed.
Supply and fixed in repairs over load protector for 1.5 TR / 2TR compressor complete all as specified and directed.
Supply and fixed in repairs Thermostate switch for 1.5 TR / 2 TR split AC complete all as specified and directed.
Supply and fixed in repairs Swing Motor for 1.5 TR / 2 TR Indoor unit complete all as specified and directed.
Supply and fixed in repairs reverse cycle solenoid valve in split/window type AC 1.5 /2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as specified and directed.
Supply and fixed in repairs suction copper pipe line heavy duty ½'' dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity complete all as specified and directed.
Supply and fixed in repairs discharge copper pipe line heavy duty 1/4" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5 TR 2 TR capacity complete all as specified and directed.
Supply and fixed in repairs PVC pipe nylon imbraided 15 mm dia for condenser water drain fitted with clamps/ concealed in wall complete all as specified and directed.
Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and supply & fixing new condensing unit complete with condensing coil, coil frame, wiring kit and running capacitor, relay condensing motor with blade complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR /2 TR split AC ( indoor unit) and supply & fixing blower motor of same manufacturer of AC of Make of AC Carrier/Voltas /Blue star as per sample complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split/window type AC unit with Refrigerant Gas compatible to R-22 type in required Qty complete all as specified and directed.
Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas non CFC compatible to R- 710 type or as eqvlnt in required Qty complete all as specified and directed.
Supply and fixed in repairs of suction valve size 1/2" complete all as specified and directed .
Supply and fixed in repairs of discharge valve size 1/4" complete all as specified and directed.
Supply and fixed in repairs of air filter made out Nylon suitable for 1.5 TR split AC capacity air conditioners of any Make and model complete all as specified and directed.
Carrying out pressure leak test of split ACs 1.5 / 2.0 TR by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all as specified and directed.
Carrying out pressure leak test of 1.5 TR window AC by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe transporting & carrying out Tools and Plant required at site complete all as specified and directed.
Supply & Fixing the new remote control unit (cordless)as per existing model for 1.5/2 TR split type A/C unit complete all as specified and directed.
S&F in replacement Compressor rotary suitable for reversible cycle split type AC 1.5 TR (Original sealed unit is to supply ) of existing Make.
S&F in replacement Compressor rotary suitable for reversible cycle split type AC 2.0 TR (Original sealed unit is to supply ) of existing Make
S & F in repairs sheet metal enclosure with metallic socket and MCB single pole 32 Amp and metallic plug top connected from mains to AC complete all as specified and directed.
S & F repairs metallic plug top of 16 Amps connected from mains to AC complete all as specified and directed.
Supply and fixing in repairs front grill quantity for window AC of 1.5 TR /2TR of exisitng Make.
Supply and fixed in repairs of mild steel stand factory fabricated made out of MS sheet 18 gauge floor/wall mounted, duly powder coated including nuts ,bolt, washer, fastners etc suitable for mounting of out door unit of split AC 1.5/2.0 TR at locations complete all as specified and directed.
Dismantling of indoor/out door unit of split type A/Cs of 1.5/2.0 TR capacity from their original locations and shifting it to other locations including servicing/overhauling of indoor/out door units,top up of refrigerant gas as required quantity and making necessary electrical connection/connecting copper tubing of suction/discharge line and testing complete all as specified and directed.
Dismantling of defective worn out wiring of window/split AC of capacity 2.0 TR TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and remote hand set to shut /match the existing system of existing make complete all as specified and directed.
Supply and fixed in repairs of PVC insulated three core stranded copper cable of size 80/20 complete all as specified and directed.
Supply and fixed in repairs Single phase Compact cooling fan motor assembly 230 volt 50 Hz 1/6 HP Along with guard etc for 2 TR walk-in-cooler complete all as specified and directed.
Repair & maintenance of water coolers of any capacity comprising of the following tasks at different location complete all as specified and directed. (a) Inspection, taking down, opening, dismantling, descaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning. (c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (j) Testing of water cooler after repair.
All as per item No 102 above but refrigerator of capacity 165/286/300/310 litre capacity charging of refrigerant gas R-22/R-134
S&F in repairs starting relay, open type for refrigerator of capacity 190/300/310 litres complete all as specified and directed.
S & F in repairs of over load protector for 1/6 HP refrigerator of capacity 190/300 /310 litres complete all as specified and directed.
S & F in repairs thermostat defrost type for refrigerator complete all as specified and directed.
S & F in repairs door gasket for refrigerator of 165 / 170 / 180 litres capacities, any make complete all as specified and directed.
All as per item No 107 above but 286 /300 /310 litres capacities
S & F in repairs freezer door with spring for Refrigerator of 165 / 170 / 180 litres capacities complete all as specified and directed.
All as per item No 109 above but for 286 /300 / 310 litres capacities
M&L for renewal of sealed unit Compressor of water cooler of capacities 60/120 ltr duly charged with refrigerent non CFC charged of existing make complete all as specified and directed
M&L for renewal of sealed unit Compressor water cooler of capacities 150 ltr capacities duly charged with refrigerent non CFC charged complete all as specified and directed (Make-Kalvinator/ Whirlpool)
Dismantling of top cover of water cooler of following capacity and S&F new top cover of following sizes 68cm x 61cm made out of 22 gauge GI sheet comprising CP MS handle of suitable size, PVC gasket, inner lining of glass wool of density not less than 48 kg/cum, locking arrangement, aluminium hinges etc and spray painting the top cover to match with the existing complete all as specified and directed
All as per item No 113 above but new top cover of size 72.5cm x 55cm x 3mm
Supply & fixing (in repairs) CP Brass push cock (inner or outer threaded) of 15 mm bore size complete all as specified and directed.
S&F in repairs float valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified and directed.
Supply & fixing (in repairs) running capacitor 25 mfd (conforming to IS:2993 - 1975) AC 440 volts in plastic container complete all as specified and directed.
All as per item No 117 above but 36 mfd
All as per item No 117 above but 50 mfd
Supply & fixing (in repairs) overload protector for 1.00 TR compressor complete all as specified and directed.
Dismantling of existing repaireable deep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor's workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
Supply and Fixing in repairs of starting relay for 190/300 Ltr. Capacity deep freezer complete all as specified and directed.
Supply and Fixing in repairs of starting relay for 190/ 210 Ltr. Capacity deep freezer complete all as specified and directed.
Supply and Fixing in repairs of over load protector suitable for 210 / 300 Ltr deep freezer complete all as specified and directed.
S&F in repairs of running capacitor for /190210 / 300 Ltr capacity deep freezer complete all as specified and directed.
S&F in repairs of thermostate suitable for 190/210 / 300 Ltr. Capacity deep freezer complete all as specified and directed.
S&F in repairs of starting capacitor for 210 / 300 Ltr. Capacity deep freezer complete all as specified and directed.
Taking down defective compressor of 310 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar capacity deep freezer of any Make and depositing same in AGE E/M (HOSP) yard and Supplying and fixing sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing complete all as specified and directed.
All as per item No 128 above but 240 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
Dismantling of liquid line filter of refrigerator of 190 litre capacities and supply & fixing new liquid filter , assembling of filter by replacing bolts & gasket etc complete all as specified and directed.
Taking out defective blower motor and transporting blower motor of any make and capacity 1/16 HP to workshop and dismanteling the burnt winding and rewinding blower motor with existing size of supper enamelled copper winding wire including insulation, varnishing, greasing and testing complete and transporting back to storeyard complete all as specified and directed.
Taking down desert cooler of any size and make from existing position i.e. stand/pillar installed at any location of building(s) including making arrangements for loading/ unloading such as rope and ladders etc. for repairs and taking back after repairs & reinstalling in its position and testing complete all as specified and directed. (Note : Necessary repairs and renewal of parts will be measured and paid for separately under appropriate items(s)
Repairing of leakage of tank by brazing/soldering of any size of desert cooler, testing the leakage water complete all as specified and directed.
S&F in repairs of of control switch/dimmer electronic 600 watt complete all as specified and directed.
S&F in repairs of set of panels made out of PGI sheet 22 gauge thick with wood wool pads, in required quantity duly filled complete as per sample and complete all as specified and directed.
Taking out defective pumps vertical/ horizontal type from desert cooler and S&F new Horizontal pump/ vertical pump of desert cooler and fixing in position complete all as specified and directed. Make Bajaj/ Crompton
S&F in repairs of wood wool pad of desert coolers suitable for 450 mm/500 mm sweep complete all as specified and directed.
S&F in repairs of kit fan, motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 18" sweep size suitable for desert cooler complete all as specified and directed. (Make:- Jyoti / Champion / Summer Cool)
Replacing capacitor single phase A/C 250 volts for ceiling fan/kit fan motor and blower motor 2.5 Mfd, complete all as specified and directed.
All as per item No 140 above but 4.00 Mfd
S&F (in repair) Gun metal globe or gate valve size 15mm dia, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F in repairs of PVC connection 15 mm dia with brass ferule both and length 600 mm size 15mm dia complete all as specified and directed. Make Prayag/ Polytuf
Collecting defective /unserviceable Heat blower of any capicity & make and size AGE E/M hosp yard and carrying to Contractor's workshop, for repair serivicuing and maint opening and cutting worntout blower motor and unserviceable heating element of any make and capacity 230V, 50 Hz, cleaning properly internally and externally and servicing complete all as specified and directed.
Supply & Fixing Blower motor of 0.50 HP with stand as per existing make and model complete all as specified and directed.
Supply and fix HEPA filter suatable for air purifier Healthy air filter effectively filters out partcicles, dust, allergens and bacteria. roduct dimensions (W x D x H) 240 x 30 x 295 mm. of existing make complete all as specified and directed.
Supply and fix air purifier PCB digital type for air purifier as per existing modle and make complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .