Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC LAMA VILLA DYMMIEW SHILLONG 793002 | EAST KHASI HILLS | MEGHALAYA | 793002 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹27.6 L+₹1.1 L (3.96%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹29.1 L+₹2.5 L (9.60%)Rejected-Finance C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹29.7 L+₹3.2 L (11.9%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical C O GIVEN GOD NONGTDAU ARBUTHNOT ROAD NONGRIMMAW LAITUMKHRAH SHILLONG PIN 793011 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793011 | - | Rejected-Technical Category not fulfil as per NIT |
| Sl No | Description | Qty | Unit | M/S DIL SINGH BISWA AND CO L1 | M/S DEEDAR ENTERPRISE L4 | Bhuiya Construction L3 | MAHINDER ELECTRICALS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out soft/loose soil complete all as specified. | 12.15 | Cubic Meter | 750 ₹9,112.5 | 800 ₹9,720 | 960 ₹11,664 | 350 ₹4,252.5 Lowest |
| 2.00 | Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr depth ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and getting out soft/loose soil complete all as specified. | 7.29 | Cubic Meter | 800 ₹5,832 | 980 ₹7,144.2 | 980 ₹7,144.2 | 350 ₹2,551.5 Lowest |
| 3.00 | Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. | 17.01 | Cubic Meter | 350 ₹5,953.5 | 380 ₹6,463.8 | 550 ₹9,355.5 | 250 ₹4,252.5 Lowest |
| 4.00 | Removing of surplus soil to a distance not exceeding 50 metre and deposited where directed at a level not exceeding 1.50 metre above the starting point all as specified. | 2.43 | Cubic Meter | 500 ₹1,215 | 500 ₹1,215 | 500 ₹1,215 | 250 ₹607.5 Lowest |
| 5.00Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to contractor store | |||||||
| 5.01 | 20 mm bore | 23 | Running Meter | 55 ₹1,265 | 90 ₹2,070 | 80 ₹1,840 | 45 ₹1,035 Lowest |
| 5.02 | 40 mm bore | 33 | Running Meter | 75 ₹2,475 | 120 ₹3,960 | 80 ₹2,640 | 45 ₹1,485 Lowest |
| 6.00 | Supply and fix 20 mm bore galvanized steel water tubing medium grade with all new fittings laid trenches in new or old aligment complete all as specified.
Make: Surya Roshni ltd/ Tata/ Jindal Steel/ Prakash/ Bansal/ Zenith/ Nezone Tubes Ltd | 23 | Running Meter | 400 ₹9,200 | 450 ₹10,350 | 550 ₹12,650 | 350 ₹8,050 Lowest |
| 7.00 | Supply and fix 40 mm bore galvanized steel water tubing medium grade with all new fittings laid trenches in new or old aligment complete all as specified.
Make: Surya Roshni ltd/ Tata/ Jindal Steel/ Prakash/ Bansal/ Zenith/ Nezone Tubes Ltd | 33 | Running Meter | 500 ₹16,500 Lowest | 500 ₹16,500 Lowest | 650 ₹21,450 | 550 ₹18,150 |
| 8.00 | Material and labour for earthing with copper earth plate electrode 60 cm X 60 cm X 3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 20 mm x 3 mm thick copper strip protected by 40 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the copper plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 8mm MS rod for handle including painting with synthetic enamel paint of approved colour and put number marked with GI plate above 45 cm from ground level as per colour code in AF station, necessary excavation and earth wok in soft/loose soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I including taking out old earthing all as specified.
Note: (i) The cost of copper strip and GI protection pipe upto 7.5 mtr is deemed to be included in the quoted rate.
(ii) The cost of excavation, earth work are deemed to be included in the quoted rate. | 40 | Each Job | 25,000 ₹10,00,000 Lowest | 27,000 ₹10,80,000 | 28,000 ₹11,20,000 | 28,500 ₹11,40,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
25 Sept 2025, 6:00 pmClosed
GE I AF SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
REPAIR AND MAINTENANCE OF VARIOUS EARTHING FOR TECH BLDG, LIGHTENING ARRESTER AND LT FEEDAR PILLAR, PANEL AND TPN DB EARTHING IN VARIOUS LOCATION AT 509 SU AF STATION LAITKOR PEAK UNDER GE (I) (AF) SHILLONG
2025_MES_726801_1
8042/25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I AF SHILLONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE I AF SHILLONG
₹50,000
Yes
13 Nov 2025
28 Aug 2025
27 Sept 2025
28 Aug 2025
25 Sept 2025
11 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .