Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | ₹6.4 Cr Quoted ₹6.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹7.2 Cr+₹61.1 L (9.26%)Rejected-Finance | ₹7.2 Cr+₹61.1 L (9.26%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹7.3 Cr+₹69.9 L (10.6%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹7.3 Cr+₹69.9 L (10.6%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹7.5 Cr+₹87.4 L (13.2%)Rejected-Finance NOT SPECIFIED | ₹7.5 Cr+₹87.4 L (13.2%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹7.9 Cr+₹1.3 Cr (19.1%)Rejected-Finance | ₹7.9 Cr+₹1.3 Cr (19.1%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹5.5 Cr
EMD Value
₹6 L
Closing Date
20 Jul 2022, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF OTM ACCOMMODATION FOR FACULTY OF CONSTRUCTION MANAGEMENT AT CME KIRKEE
2022_MES_526831_1
CA NO CEPZ/KKE/TOKEN-21 OF 2021-22
Open Tender
Civil Works
Lump-sum
390 days
CME Kirkee
Class A
Category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹3,000
GE (CME) Kirkee
₹6 L
Yes
6 Sept 2022
27 May 2022
22 Jul 2022
27 May 2022
20 Jul 2022
28 Jun 2022
28 May 2022 - 13 Jun 2022
Amount
NOTE: Schedule 'A' Part - I to X are pre-priced by MES. Bidders shall insert their lumpsum amount in the blue coloured field under column 6 only.
Total amount of Sch 'A' Part-I (Building Works)
Total amount of Sch 'A' Part-II (Internal water Supply)
Total amount of Sch ‘A’ Part III (Internal Electrification)
Total amount of Sch ‘A’ Part IV (External Water Supply)
Total amount of Sch ‘A’ Part V (External Electrification)
Total amount of Sch 'A' Part-VI (Road, path, culverts)
Total amount of Sch ‘A’ Part VII (Sewage Disposal)
Total amount of Sch 'A' Part-VIII (Area drainage)
Total amount of Sch 'A' Part-IX- (Compound wall / Fencing & Gate)
Total amount of Sch ‘A’ Part X (Site clearence, Excavation & earthwork)
SCH 'A PART XI (Miscellaneous items) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
INTERNAL ELECTRIC SUPPLY
Fixing only LED light fitting 1x20 watt 230 Volt energy saver indoor domestic plastic extruded luminaire with decorative, including providing connection with and including copper conductor flexible cord of suitable cross sectional area of required length from ceiling rose to connector block of fitting complete all as specified and directed by Engr-in-Charge. Note: LED light fittings 1 x 20 Watt of Make- Bajaj 631 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only LED Security light fitting 30 watt 230 Volt all accessories including providing and connection with and including copper conductor flexible cord of suitable cross sectional area of required length from ceiling rose to connector block of fitting complete including testing on completion all as specified and directed by Engr-in-Charge. Note: LED Security light fittings 30 Watt of Make- Surya 08 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only ceiling fan, 1200 mm (48") sweep, with and including assembling the blades and with fan hook / box includinh connecitng up with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan suitable on working AC, SP 230 V electric supply including testing on completion complete all as specified and directed. Note: Ceiling fan 5 star rating 1200mm sweep with blades of Make- Crompton 158 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only LED lamp, 9 watt, 230 volts complete all as specified and directed. Note: LED lamp 9 watt of Make- Wipro 18 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only MCB, Single pole and neutral, 240 volts, 6 to 32 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site. Note: MCB SPN 6 Amp 240 Volts of make-Havells 21 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only MCB, Triple pole and neutral, 415 volts, 40 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site. Note: MCB TPN 40 Amp 415 Volts of make-Havells 09 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing ony MCB, Triple pole and neutral, 415 volts, 63 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site. Note: MCB TPN 40 Amp 415 Volts of make-Havells 09 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only MCB, Single pole, 240 volts, 6 to 32 Amps, 10 KA, 'B' Series, complete all as specified and as directed at site. Note: MCB SP 6 Amp 240 Volts of make-Havells 218 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Supply, install, test and commissioning factory made, CPRI approved weather, dust and vermin proof L.T cubical panel OUTDOOR type, as per IS-8623 fabricated with 3.15 mm thick CRCA Sheet epoxy powder coated paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 600 Amps rating bus bars of high conductivity copper alloy for phases and half for neutral and shall be provided with colour coded head shrinkable sleeves. Including bottom glanf plate consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber bushes to prevent ingress of wter/vermin etc, inside the enclosure the required no of holes to be fixed with chromiun plated brass cable glandsfor incoming and out going cables, with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size including connection. The panel shall be provided with separate compartments for each switch gear etc with double stud hinged door, front openable with locking arrangement and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 Cycles, AC suppply and to with protection shall he IP 48. The panel shall be fixed with angle iron frame made of angles of suitable size fixed on wall comprising the following with CPRI approved :
a) Bus bars of aluminium strips of 600 Amps currrent capacity TPN, of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulators - 1 set
b) MCCB 4 pole 200 Amp, 415 V, 50 Hz, 35 KA breaking capacity - 01 No (incoming)
c) MCCB TPN 80 Amp, 4 pole, 25 KA - 04 No (Out going)
d) MCCB TPN 63 Amp, 4 pole, 25 KA - 08 No (Out going)
e) LED type indicator lamp - 03 Nos
f) Internal wiring with suitable size copper conductor PVC insulated heavy duty cable.
h) Ameter 0-200 Amps with suitable CT's -01 No
j) Voltmeter 0-500 Volts - 01 No
Fixing only exhaust fan, single phase, heavy duty, 230 mm sweep, 1400 RPM including fixing of mounting frame in the round hole inclding cuting in the wall and making good and fixing fan by means of rugged bolts, nuts and washers etc including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of exhaust fan complete all as specified and directed. Note: Exhaust fan 230 mm sweep 1400 RPM of make- Crompton 16 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised iron strip of size 32 mm x 6 mm, by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion, complete all as specified and as directed. Note : GI earth strip & GI pipe 40 mm bore medium grade for encasing GI wire beyond 7.50m length per earthing if so required at site shall be measured & paid separately
EXTERNAL WATER SUPPLY & FOUNTAIN
Supply, install, testing, commissioning of DUAL PLATE NON-RETURN VALVE, suitaable for bore of pipe 100 mm, heavy duty, conforming to IS, with & including neoprene rubber gasket joint with necessary nuts & bolts & washers, complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Laying only, jointing, testing & commissioning LT Cables, 1100 volts grade, XLPE insulated, armoured & PVC sheathed with stranded aluminium conductor, heavy duty conforming to IS 1554 Part I, ISI marked to be laid in trenches fixed along the poles or drawn through GI pipes laid under floors, road etc fixed concealed in walls, encased in GI pipe of following sizes complete all as specified and directed. Note: LT cables XLPE (Make-RR Cables) as per the follwing sizes and as per quantities mentioned against each item brought at site by the defaulter Contractor shall be issued under Schedule 'B' free for fixing.
(a) 2 core x 10 sqmm
(b) 3.5 core x 70 sqmm
(c) 3.5 core x 95 sqmm
(d) 3.5 core x 300 sqmm
S&F MCCB, Four pole, 250 Amps, 35 KA in existing panel board with adjustible over load relay, Adjustible shot circuit setting conforming to IEC 60947, Cat Part No CM92109OOP1OG of L&T or equivalent model in Havells / HPL complete all as specified and as directed at site.
Supply and fix LT junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 230 mm x 170mm x 105 mm (outer) including 10 Amps MCB, 01 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs including fixing arrangements, complete all as specified and as directed. Make: Sintex or equivalent as approvd by GE.
M & L for horizontal directional drilling of upto 200 mm dia (using trenchless technology) in any type of strata conditions using necessary mechanical means and all necessary T&P incl necessary excavation for placement of drilling unit for distances upto 25 m long in locations of depth not less than 1.5 m as directed.
Fixing only LED street light fitting 60 Watt capacity with Pressure die cast aluminium housing with heat resistant toughened glass & IP66 protection comprising of High power LEDs, complete including connecting and testing on completion, all as specified and as directed. Note: LED Street light fittings 60 Watt of Make- Surya 16 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
Fixing only LED Garden / Gate light decorative luminaire, energy saving, 40 Watt capacity with Pressure die cast aluminium housing with heat resistant toughened glass & IP65 protection comprising of High power LEDs, including connecting and testing on completion, complete all as specified and as directed. Note: LED Street light fittings 60 Watt of Make- Surya 09 Nos brought at site by the defaulter contractor shall be issued under Schedule 'B' free for fixing.
M & L for Pole earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised earth lead wire 4.00 mm dia (8 SWG), by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion, complete all as specified and as directed. Note : GI earth strip & GI pipe medium grade for encasing GI wire beyond 7.50m length per earthing if so required at site shall be measured & paid separately.
Supply ,Install Testing & Commissioning factory made, CPRI approved, LT Feeder Pillar made of 3.15 mm CRCA sheet, powder coated, self supporting Outdoor type totally enclosed compartmentalised design, dust and vermin proof of suitable size for 440 Volt 3 phase 4 wire system having front double hinged detachable doors with neoprence rubber gasket including danger plate, earthing strip point at rear side, ventilation louvers, bottom detachable gland plate complete. The panel shall be mounted on angle iron 32x6 mm using foundation Bolts at height of 60 cm from gnd level on angle iron 32 x 6 and incl PCC 1:3:6 Foundation of size 1.00 m x 1.00 m x 0.10 m and including the following components:
(a) MCCB FP 250 Amps 35 KA 1 No (Incoming)
(b) MCCB FP 160 Amps, 35 KA, 415 Volts-01 No (outgoing)
(c) MCB SPN 20 Amps - 01 No
(d) MCCB FP 100 Amps, 25 KA, 415 Volts-01 No (outgoing)
(g) Indicating lamps with assembly - 03 Nos
(h) Street light timer SP 230v, 20 Amps - 01 Nos
(j) Aluminium bus bar 400 Amps capacity for three phase and neutral - 01 Set.
Fixing only and Installing, testing & commissioning Diesel engine driven Generating set with AMF panel 125 KVA, 415 V, 3 Phase, 4 Wire, 50 cycles and Power factor 0.8 complete and accoustic enclosure, considering all derating factors, for sound less mode (sound level not exceeding level specified by central pollution control board), all as per BS 5514 / IS-10002 complete with control panel, of capacity continuous rating 125 KVA at NTP conditions and comprising of the following:- NOTES: (i) DG Set Containing Prime mover, Alternator, Canopy but without AMF Panel shall be issued under Sch "B" free for fixing only. (ii) AMF Panel shall be supplied by the contractor under item No. 5.00 here-in-below as "supply only". However, cost of fixing, installing, testing & commissioning of AMF Panel shall be deemed to be included in item No. 4.80 above.
(i) Exhaust pipe brought outside the building and lagging of entire length of exhaust pipe with 12 mm dia Asbestos rope / Rock Wool
NOTES FOR SCOPE OF ITEM FOR THE DG SET TO BE INSTALLED AS ISSUED UNDER SCH 'B':-DG Set has been supplied by the defaulter contractor with canopy and the scope of the above item is for entire completion of item all as per specifications above and as per provisions given hereunder through OEM of the DG Set.
(i)The engine and alternator will be coupled, aligned and mounted on a sp-acially designed common base frame fabricated from MS channels of suitable cross sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads, Make: Dunlop/Polybond of reqd size and numbers as recommended by the manufactureres for mounting of 125 KVA DG Set
(ii) PCC/RCC foundation complete as per manufacturers design for installationn of DG set is included in the rate quoted for this item.
(iii) Documents : Three sets of following documents :- Maintenance and operation manuals for engine and alternator, spare parts catelogue, warranty/test certificates, schematic diagrams of control panels.
(iv) Misc items : List of tools and two years normal maintenance spares as per manufactures recommended lists, duly priced item wise
(v) Change over switch 200 Amps 415 volts, 4 pole -01 No with sheet metal enclosure complete. (vi) Contractor will satisfactorily conduct load test of DG Set for 12 hrs incl run on 10% overload for 1 hr
(vii) Testing equipment will be arranged by the contractor. (viii) Fuel required for tests, water load equipment spares & such accessories required for PH-I & PH-II tests of DG Set shall be supplied by the contractor.
(ix) All connections from Control Panel to DG set and DG set to Existing panel for power and control cables are to be connected by the contractor. (x) Any essential and unavoidable fittings / fixtures required for proper functioning of DG SET are deemed to be included in the rates quoted for this item.
Supply only AMF Panel for 125 KVA DG set as specified in item No. 4.80 above complete as specified and directed by Engineer-in-Charge. NOTE: Drawing of AMF Panel shall be got approved by the contractor from Engineer-in-Charge.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .