Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹10.0 L+₹3,970 (0.40%)Rejected-Finance GUDSATHU BUDGAM KASHMIR 191111 J K | BUDGAM | BUDGAM | JAMMU AND KASHMIR | 191111 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹10.3 L+₹34,250 (3.43%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹11.3 L+₹1.3 L (12.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
16 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINTENANCE OF INDUSTRIAL RO PLANTS, WATER PUMPS, WATER HEATING PLANTS, MOTORS AT HQ CIF (K) UNDER AGE (I) CIF (K).
2023_MES_598555_1
CA NO. AGE (I) CIIF (K)-16/2023-24
Open Tender
Civil Works - Water Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹20,000
Yes
30 Jun 2023
26 May 2023
19 Jun 2023
26 May 2023
16 Jun 2023
9 Jun 2023
Amount
Material and labour for servicing to RO Plant of capacity 3000 Litres/hours including chemical cleaning by skilled person of Indian ion company, complete all as specified and directed by the Engineer-in-Charge.
Material and labour for servicing to RO Plant of capacity 500 Litres/hours including chemical cleaning by skilled person of Thermax company, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement Hydraulic membranes top quality recommended by Indian ion company suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I)
Supply and fixing in replacement Hydraulic membranes top quality recommended by Thermax company suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make -Thermax or equivalent as approved by AGE (I).
Supply and laying in replacement Media complete (Carbon, Stone, Sand and Pebbles) suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying in replacement Media complete (Carbon, Stone, Sand and Pebbles) suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement UV Ballast and fuse etc. complete suitable for 3000 litres per hour RO Plant , complete all as specified as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement UV Ballast and fuse etc. complete suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement UV Candle 20 inch long suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement UV Candle 20 inch long suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make -Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Hose pipe 20 mm suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement Hose pipe 20 mm suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I)
Supply and fixing in replacement Rotor Meter suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I)
Supply and fixing in replacement Rotor Meter suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Pressure Meter suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Pressure Meter suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Supply and fixing in replacement Relay for automatic Panel suitable for 3000 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Supply and fixing in replacement Relay for automatic Panel suitable for 500 litres per hour RO Plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ion or equivalent as approved by AGE (I).
Dismantling and replacement existing burnt winding of water pump 5.5 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 3000 litres per hour RO plant, complete all as specified and as directed by the Engineer-in-Charge. Make - Indian ION or equivalent as approved by AGE (I).
Dismantling and replacement existing burnt winding of water pump 2.5 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 500 litres per hour RO plant, complete all as specified as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Dismantling and replacement of existing burnt winding of water pump 2 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 3000 litres per hour RO plant, complete all as specified as directed by the Engineer-in-Charge. Make - Indian ION or equivalent as approved by AGE (I).
Dismantling and replacement existing burnt winding of water pump 1 HP by new copper winding wire including binding, varnishing, fitting in same place and testing complete suitable for 500 Ltrs per hour RO plant, complete all as specified as directed by the Engineer-in-Charge. Make - Thermax or equivalent as approved by AGE (I).
Taking down old unserviceable PVC pipe 32mm bore and supply and fixing new PVC pipe 32mm bore complete with all fitings, complete all as specified as directed by the Engineer-in-Charge.
Supply and fixing in replacement globe or gate valves, 32mm bore brass body head, screwed both ends (as per sample) for stainless steel pipe, complete all as specified and directed by the Engineer -in - Charge. Make :- Bir/Venus/Leader/Kirloskar
Supply and fixing in replacement gun metal, globe or gate valves, 50 mm bore with iron wheel head, screw both ends for iron pipe and fixed , complete all as specified and directed by the Engineer -in - Charge. Make :- Bir/Venus/Leader/Kirloskar
Material and labour for servicing of dosing pump 0.5 HP capacity and repalcement of PVC pipe complete as specified and as directed by the Engineer -in - Charge.
Supply only Cartridge 30 inches long of RO Plant 3000 Litres /hours, complete all as specified as directed by the Engineer-in-Charge. Make - Indian Ion or equivalent as approved by AGE (I).
Supply only dosing Chemical anti-scalant as per recommended by indian ion company, complete all as specified as directed by the Engineer-in-Charge.
Supply and fixing in replacement Media carbon (coconut shell coal) suitable for sand filtration plant of capacity 10000 Glans, complete as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement Media complete (stone,sand and pebbles) suitable for sand filtration plant, complete as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement PVC nozzels suitable for sand filtration plant of capacity 10000 Glans, complete all as specified and directed by the Engineer -in- Charge.
HEATING PLANTS AND WATER PUMPS:- Material and labour for dismanteling of fuel injector pump, transporting to work shop for repair such as Calibration and complete repair of fuel injection pump of Hot water plant 250 litres on work bench pressure supply of fuel as standard procedure , complete all as specified and directed by the Engineer -in - Charge. Note:- Any spares required for repair such as washers for speed adjustment ,split cotter pin etc. shall deemed to be inclusive in the quoted rates.
Supply and fixing in replacement of nozle tip, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of photo sensor, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of photo ignition transformer, complete as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of burner gasket, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of electromagnet rod, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of auto thermocut, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of relay box, complete all as specified and directed by the Engineer -in - Charge.
Disconnecting existing defective electric motor of any make 20 HP from electric mains isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, decouple from pump, opening of motor for inspection in presence of Engr-in-Charge and carry out minor repairs at site or transporting to workshop and back, re-assembling the motor after repair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning, complete as specified and directed by the Engineer -in - Charge. Note :- (a) Replacement of defecting parts shall be measured and paid separately. (b) In case of major repairs not possible at site, the motor shall be shifted to contractor’s workshop, and cost of shifting to workshop and back to site shall be deemed to be included in the rates quoted.
Description all as per serial item No 40 here-in-before, but of capacity 2.0 to 5.0 HP, complete as specified and directed by the Engineer -in - Charge.
Taking out old unserviceable/burnt copper winding of motors capacity 20 HP (defective motor taken out in item No. 40 here-in-before) and material and labour for rewinding of electric motor of capacity 20 HP with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engineer-in-Charge,complete as specified and directed.
Description all as per serial item No 42 here-in-before, but of capacity 2.0 to 5.0 HP, complete all as specified and directed by the Engineer -in - Charge.
Material and labour for replacement of coupling suitable for pump set 20 HP capacity centrifugal pump as per site requirement,complete all as specified and directed by the Engineer -in - Charge.
Taking out unserviceable terminal plate with connector and outer cover of electric motor of any make, type 20 HP capacity and supply, connecting and testing terminal plate with connector same as per existing, complete all as specified and directed by the Engineer -in - Charge.
Description all as per serial item No 45 here-in-before, but of capacity 2.0 to 5.0 HP, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of Ball bearing of the electric motor 20 HP opened in serial item No.40 here-in-before, complete all as specified and directed by the Engineer -in - Charge. Make: SKF/TATA/NBC.
Description all as per serial item No 47 here-in-before, but of capacity 2.0 to 5.0 HP, complete all as specified and directed by the Engineer -in - Charge.
Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out from well the submersible pump set including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge, and carrying out necessary repairs as directed including transporting to workshop, re-assembling the same after repair, taking down in well, including column pipe of any dia, 10 ft long upto 20 Nos, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning, complete all as specified and directed by the Engineer -in - Charge. Note:- The replacement of parts shall be measured and paid for separately.
Material and labour for rewinding the submersible 3 phase motor, 5 HP with insulated winding wire as per existing gauge as approved by Engineer-in-Charge and testing after repair including taking out old unserviceable/burnt winding from the, complete all as specified and directed by the Engineer -in - Charge.
Description all as peral item No 50 here-in-before, but motor 10 HP, complete all as specified and directed by the Engineer -in - Charge.
Description all as per item No 50 here-in-before, but motor 15 HP, complete all as specified and directed by the Engineer -in - Charge.
Description all as per item No 50 here-in-before, but motor 1.0 to 1.5 HP, complete all as specified and directed by the Engineer -in - Charge.
Supply and fixing in replacement of unserviceable/defective Gun metal impeller of submersible pump of any make and of capacity 10 HP after inspection by Engineer-in-Charge,complete all as specified and directed.
Description all as per serial item No 54 here-in-before, but of capacity 10 HP, complete all as specified and directed by the Engineer -in - Charge.
Description all as per serial item No 54 here-in-before, but of capacity 15 HP, complete all as specified and as directed by the Engineer -in - Charge.
Supply and fixing in replacement of unserviceable/defective PVC bush of submersible pump of any make and of capacity 1.0 to 1.5 HP after inspection by Engineer-in-Charge, complete all as specified and directed
Supply and fixing in replacement of unserviceable/defective PVC impeller of submersible pump of any make and capacity 1.0 to 1.5 HP after inspection by Engineer-in-Charge , complete all as specified and as directed
Supply and fixing in replacement of unserviceable/defective Gun metal impeller of submersible pump of any make and capacity 10 HP after inspection by Engineer-in-Charge, complete all as specified and as directed.
Description all as per serial item No 59 here-in-before, but of capacity 15 HP, complete all as specified and as directed by the Engineer -in - Charge.
Description all as per serial item No 59 here-in-before, but of capacity 5 HP, complete all as specified and as directed by the Engineer -in - Charge.
Material and labour for dismanteling to fuel injector pump, transporting to work shop for repair/ servicing such as Calibration and complete repair of fuel injecton pump of Hot air plant of any capacity on work bench pressure supply of fuel as standard procedure, complete all as specified and as directed by the Engineer -in - Charge. Note:- Any spares required for repair such as washers for speed adjustment ,split cotter pin etc. shall deemed to be inclusive in the quoted rates.
Supply and fixing in replacement star delta starter, 03 Phase, 415 volts, 50HZ of capacity 15HP Modle no MU-G15 FASD (WITH WIDEBAND COIL), complete all as specified and as directed by the Engineer-in-Charge. Make : Havell’s /L&T/ Siemens
Supply and fixing in replacement star delta starter, 03 Phase, 415 volts, 50HZ of capacity 20HP Modle no MU-G20 FASD(WITH WIDEBAND COIL), complete all as specified and as directed by the Engineer-in-Charge. Make : Havell’s /L&T/ Siemens
Supply and fixing in replacement star delta starter, 03 Phase, 415 volts, 50HZ of capacity 10HP Modle no MU-G10 FASD(WITH WIDEBAND COIL), complete all as specified and as directed by the Engineer-in-Charge. Make : Havell’s /L&T/ Siemens
Supply and fixing in replacement ON LOAD changeover switch (Euroload) 4 pole open execution 100 Amp capacity, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havell’scat no IHCNFOO100 or equlant of /L&T/ Siemens
Supply instalation testing and commissing in repairs complete motor of Air heating plant as per sample, complete all as specified and as directed by the Engineer-in-Charge. Make:- As per sample in existing plant
Material and labour for dismanteling to fuel injector pump, transporting to work shop for repair such as Calibration and complete repair of fuel injecton pump of Hot water plant 100litres capacity per hour on work bench pressure supply of fuel as standard procedure, complete all as specified and as directed by the Engineer-in-Charge. Note:- Any spares require for repair such as washers, for speed adjustment ,split cotter pin etc. as deemed to be inclusive in the quoted rates.
Replacement of nozle tip, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of poto sensor, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of poto ignetion transformer, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of burner gasket, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of electromegnet rod, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of auto thermocut, complete all as specified and as directed by the Engineer-in-Charge.
Replacement of relay box, complete all as specified and as directed by the Engineer-in-Charge.
Note :- An amount of Rs. 24,565.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
JK BUILDERS AND ENGINEERS
M/S A Q ENTERPRISES
M/s KASHMIR BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .