| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹47.7 L+₹2.8 L (6.24%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.6 L+₹4.7 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.9 L+₹5.0 L (11.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹50.0 L+₹5.0 L (11.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 Jun 2024, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR MAINTENANCE OF SUMMER APPLIANCES HOT WATER GENERATOR SPLIT TYPE AC, DEEP FREEZER, VRR/VRF TYPE AC AT DMRL, ATC AND NEWLY TAKEN OVER BLDG FROM CCE RND UNDER GE (I) RND KANCHANBAGH, HYDERABAD
2024_MES_658824_1
8793/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
26 Sept 2024
10 Jun 2024
1 Jul 2024
10 Jun 2024
29 Jun 2024
24 Jun 2024
10 Jun 2024 - 17 Jun 2024
Amount
Overhauling and servicing of split type AC of capacity 1.5/2.0 TR of any make at different locations at DMRL/ATC/RCMA, testing the unit complete with the following tasks:- (a) Overhauling & servicing (b) Inspection opening washing the condensor coil and cooling coil with chemical followed with pressurized water jet complete (c) Inspection and treatment of leakage of refrigerant in the system. (d) Checking of operation of blower motor, condensor motor and swing motor for noise free operations (e) Oiling of condensor / blower motors and checking the earth continuity (f) Inspection of all electrical parts / connections and rectification of any small defect (g) Checking of functional of electronic remote control unit to ensure satisfactory functioning of unit complete all as specified and as directed (h) Inspection and treatment of leakage water from indoor unit
All as per item 1.00 but for Window type AC of capacity 1.5 / 2.0 TR Note:- During servicing of unit, if any spares / parts are required to be replaced it shall be measured and paid separately under respective items mentioned here- in - after.
Attending day to day complaints for split/window type AC of capacity 1.5/2.0 TR and their electrical connection upto DBs installed in side of Tech area of DMRL/ATC/RCMA under GE (I) R&D K' Bagh and rectifying the defects and making machine satisfactory functional from 0900 Hrs to 1700 Hrs ( for 08 HRS only) excluding Sunday/Holidays.
Note:- (i) Any defective part which are required to be replaced to make functional ACs shall be measured and paid seperatly under relevent items as per direction. (ii) Contractor will provide well experienced 1 No AC Mech with 1 Nos Helper for attending complaint on requirement basis (for 900 hrs to 1700 hrs excluding Sundays & Holidays) in addition to man power required for execution of other routine works. Complaint has to be received from concerned JE on day to day basis (iii) All Tools & Plants required for repair work shall be provided/arranged by the contractor at his own arrangement to trade men & helpers. (iv) All complaints should be attended with in 24 hours of reporting of complaints. Panelty charges for non attending complaints with in 24 hrs shall be double the quoted rate per complaint per day.
S&F in replacement blower motor for Indoor unit, of same specification/make as per existing one, suitable for split AC 1.5TR capacity complete including taking out of old unserviceable one all as directed.
All as per Item No 4 but of 2.0 TR capacity complete
S&F in replacement blower fan for indoor unit, of same specification/make as per existing one suitable for split AC 2.0/1.5 TR capacity complete including taking out of old unserviceable one all as directed.
S&F in replacement condensor fan motor with blade for outdoor unit, of same specification/make as per existing one, suitable for split AC 1.5TR capacity complete including taking out of old unserviceable one all as directed.
All as per Item No 7 but of 2.0 TR capacity complete
S&F in replacement hermitically sealed compressor for split type AC of capacity 1.5TR as per existing including brazing work, laying of extra copper tubing, pressure testing, dehydration,gas charging upto required level and testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge Make : Copeland/Danfoss/kirloskar / LG/ Carrier / Blue star/Voltas/Hitachi (As per site requirement)
All as per item no. 9 above but for split type AC of capacity 2.0 TR
M&L for rewinding of condensor fan motor of split type AC of cap 1.5/2.0 TR including replacement of gun metal bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed by Engineer-in-charge
S&F in replacement to indoor unit for split type AC complete with motor, blower, remote control, filters having cooling capacity 4500 K.Cal / Hr complete all as specified and as directed by Engineer-in-charge Make- Carrier(Totaline) / Hitachi / Blue star/Voltas/LG/Samsung
All as per item no. 12 above but capacity 6000 K.Cal / Hr
S&F in replacement to sheet steel body of the outdoor unit for split type AC complete of capacity 4500 K.Cal / Hr with condenser ,service valves, liquid line filter and capilary tube set without compressor complete all as specified and as directed by Engineer-in-charge Make- Carrier(Totaline) / Hitachi / Blue star/Voltas/LG/Samsung
All as per item no. 14 above but capacity 6000 K.Cal / Hr
S&F in replacement copper condenser unit for outdoor unit of split type AC of capacity 1.5TR as per existing specification/make including brazing work, laying of extra copper tubing, leakage testing and testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge
All as per item no. 16 above but capacity 2.0 TR
S&F in replacement Oscilation motor with swing blade strip suitable for indoor unit of 1.5 TR/2 TR capacity Split AC of same specification/make as per existing one complete including taking out the old unserviceable one all as directed
M&L for repair to unserviceable with cord/cordless PCB remote control unit of for indoor unit of split type AC of cap 1.5 TR/2.0 TR including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed
M&L for repair to unserviceable with cord/cordless PCB remote control unit of for outdoor unit of split type AC of cap 1.5 TR/2.0 TR including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed
S&F in replacement hand set remote for Split type AC of cap 1.5 TR/2.0 TR, with features of digital display,all controls including battery all as per exsting specification and model complete all as specified and directed Make : Blue Star / LG / Carrier/ Voltas/Hitachi/Samsung (As per site requirement)
All as per Item No 24 but capacity 5 KVA
S&F in replacement copper tubing flexible of dia 5/8" including heavy duty nitrile rubber insulation complete all as specified and directed by Engineer-in-charge
All as per item 26 but of dia 3/8"
All as per item 26 but of dia 1/2"
All as per item 26 but of dia 1/4"
M&L for insulation only to copper tubing of split type AC of cap 1.5 TR/2.0 TR with heavy duty rubber foam insulation as per existing density and thermal conductivity including packing material, reflactor tape and pvc tie complete all as specified and directed. Make- Armaflex / Aeroflex / Thermobreak
S&F in replacement of flexible type water drain out pipe suitable for indoor unit of split AC as per existing type/model complete all as specified and directed.
M&L for Dismantling,shifting and refixing of split type AC of any make & model from one location to another location at DMRL/ATC/RCMA and refixing the AC with gitties/fasteners, core cutting in brick wall/concrete incl arrangement of required T&P, laying of extra insulated copper tubing, positioning of condensing unit and brazing work, leak check, dehydration and topping up of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including making good the PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed. Note :- Refrigerant, if required to be charged, shall be measured and paid separately under relevant item mentioned here-in-under.
Supply and topping up/charging of refrigerent gas (R-22) for ACs as per standard practice all as specified and directed.
Supply and topping up/charging of refrigerent gas (R-410) for ACs as per standard practice all as specified and directed.
Supply and topping up/charging of refrigerent gas (R-32) for ACs / Water Coolers as per standard practice all as specified and directed.
Supply and topping up/charging of refrigerent gas (R-134A) for Refrigerators as per standard practice all as specified and directed.
M&L for pressure testing of the split /window air conditioner of any capacity complete with filling of nitrogen gas after flushing out the system free from any oil / grease etc. cheking for leakages if any in the refrigerent system making good the leaking parts with necessary brazing/welding, ensuring leak proof system and charging of refrigerent gas and testing for satifactory performance complete all as specified and as directed
M&L for submain wiring with 2x2.5 SQMM + 1x2.5 SQMM Earth Wire single core PVC insulated FRSL sheathed copper cable connecting to common earth dolly in and including heavy duty PVC Casing caping as per direction , all accessories complete all as specified and directed. Note:- 4 run copper wire and 1 run casing caping shall be measured as unit length.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A to 32 A complete all as specified and directed.
S&F modular type motor starter, suitable capacity for split/window type air conditioners inluding cover plate and PVC surface box of suitable type complete all as specified and directed. Make:- CRABTREE/ANCHOR(PENTA)/LEGRAND
S&F in walls/roofs PVC Pipe 20 mm heavy duty for Condensing water line including making provision for fixing.
S&F in walls/roofs PVC Pipe 40 mm heavy duty for Condensing water line including fittings and making provision for fixing.
S&F in replacement the following spare parts for Air Conditioners of any make & model all as specified and directed
Connector open type 30Amps, 3/4 way for outdoor unit
Starting capacitor 80 -100 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Starting capacitor 120 -150 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Running capacitor 2.5 to 6 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Running capacitor 36 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Running capacitor 45 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Running capacitor 52 + 4 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Running capacitor 55 mfd heavy duty 230v, AC supply Make-Epcos / Sarada / Usha / Tibcon
Metal clad 3 pin plug top 20 amps 230 Volt, Single Phase Make: L&T / Legrand/Standard/Indoasian/Havells
Metal clad 3 pin socket 20 amps 230 Volt, Single Phase Make: L&T / Legrand/Standard/Indoasian/Havells
MCB SP 20-32 amps 230 Volt, Make: L&T / Legrand/Standard/Indoasian/Havells
Brass flair nuts 1/2 to1/4"
Brass flair nuts 3/8 to 5/8"
PVC insulated 3 core round flexible copper cable 1100 v grade of size 2.5 sq mm Make:- Plaza/Polycab/Havells/Finolex
PVC insulated 4 core round flexible copper cable 1100 v grade of size 2.5 sq mm Make:- Plaza/Polycab/Havells/Finolex
M&L for servicing of Water Cooler, of capacity 40/80 Ltr, unit by cleaning with air pressure, tightening of nut bolts, arresting all leakages, and cleaning of condensor, water line etc, checking of serviceablity of fan motor, compressor, relay, capacitors, thermostat control circuits, remote and sensor etc including electrical circuits and submitting the report excluding spares, compressor and Refrigerent capacity complete all as directed.
M&L for disconnecting the unserviceable sealed compressor unit from the Water Cooler (capacity 40/80 Ltrs) of any make & model and removing the same and S&F new hermetically sealed compressor unit, of existing specification, connecting it with both refrigerant line & electrical line for smooth operation on single phase 230 Volts, 50HZ AC supply all as specified and as directed.
S&F in replacement relay and OLP assay 40/80 ltr capacity water cooler
S&F replacement of starting capacitor 60/80 mfd for water cooler complete all as directed
S&F replacement of running capacitor 25 mfd for water cooler complete all as directed
S&F replacement of Thermostatic switch for water cooler of any capacity complete all as directed
S&F replacement of door gasket for water cooler 40/80 Ltrs complete all as directed
S& F replacement of blower fan motor with blades suitable for 40/80 Ltrs water cooler all as directed
S&F replacement push cock brass chromium plated 15 mm dia complete all as directed
Dismantling unserviceable storage tank of the water cooler, supply and fixing of stainless steel storage tank, including connecting inlet and outlet connections all as directed at site of capacity 40 Ltrs.
S&F in repairs of plastic body of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in repairs of corbon water filter of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in repairs of motor of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in repairs of diverter valve of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in repairs of Diaphagram pump motor of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in repairs of filter cartrage of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in repairs of RO membrane of the water purifier of capacity 10-50 ltrs per hour complete all as directed by Engr-in-Charge.
S&F in replacement desert cooler pump 1/83 HP operating on SP 230V, 50Hz AC supply complete all as directed
S&F in repalcement desert cooler fan motor operating in SP 230V, 50Hz AC supply complete with blade multispeed suitable for desert cooler of 4000 CFM/Hr complete all as directed
S&F replacement PVC distributor 3 way suitable for 15mm bore pipe connection of desert cooler complete all as directed
S&F in repalcement of polythylene pipe flexible 15mm dia for water cooler complete all as directed
Replacement of woodwool for 4000 CFM desert cooler
M&L for sheet making SM/MES / Mech No with letter of size not more than 1 inch fixed on 3 mm hylium /PVC sheet duly fixed to the plant by adhersion/ reveat all as directed
M&L Spray painting of water cooler 40/80 Ltr capacity including scrubbing of old paint, apply one coat red oxide two coat of synthetic enamel paint
All as per Item No 67 above but for desert cooler any size
Cutting and removing the rustedout sheet metal enclosure of water cooler and supplying and fixing new MS sheet metal of 1.6 mm thick duly bend / fabricated into suitable size and duly welded to the existing body and finishing properly including painting with two coats of synthetic enamel paint over a coat of suitable primer / metal paste etc fiishing the surface properly all as directed for water cooler of any capacity.
Dismantling unserviceable storage tank of the water cooler, supply and fixing of stainless steel storage tank, including connecting inlet and outlet connections all as directed at site of capacity 40 Ltrs.
M&L for disconnecting the unserviceable sealed compressor unit from the Refrigerator (capacity 165-200 Ltrs) of any make & model and removing the same and S&F new hermetically sealed compressor unit, of existing specification, connecting it with both refrigerant line & electrical line for smooth operation on single phase 230 Volts, 50HZ AC supply all as specified and as directed.
S&F replacement OLP relay assy suitable for refrigerator 165 to 360 ltrs cap complete all as directed
S&F replacement thermostatic switch suitable for refrigerator 165 to 310 ltrs capaicity complete all as directed
S&F replacement magnetic door gasket suitable for refrigerator 165 ltrs capacity complete all as directed
S&F replacement cabinet lamp suitable for refrigerator complete all as directed
S&F replacement of tray suitable for refrigerator 165 to 410 ltrs capacity complete all as directed
S&F replacement of storage box suitable for refrigerator 165 to 185 ltrs capacity complete all as directed
S&F replacement of storage box suitable for refrigerator 200 to 320 ltrs capacity complete all as directed
S&F replacement of filter suitable for refrigerator of any size/capacity complete all as directed
S&F replacement Fan motor suitable for refrigerator complete all as directed
S&F replacement of Digital time switch of 230 Volts for Split/Window type ACS complete all as directed Make L&T/C&S/Seimens
Supply and fixing of 2 AC Timer Change over switch for ACs installed at Tech area bldgs of DMRL/ATC Eqpt complete all as specified and as directed. Make : Dynamic, Model DIGI 2017
Supply and fixing of 3 pole power contractor for 2 Ton AC outdoor unit all as directed and specified
Servicing of Hot water generator of capacity 54 KW, 3 steps, 415 volts complete all as specified and directed.
Servicing of de-Ionised water plant of capacity 1000 ltrs per day complete all as specified and directed.
Repairs to Heat water pump for burnt out motor winding with super enameled copper wire winding complete with existing gauge including varnishing, greasing, reassembling and connecting Electrical and water connection with transportation for rewinding of motor from to and back to site / termination complete all as directed. 2 HP
M&L for rewinding of the heat water motor of 2 HP capacity duly disconnecting electrical connections and taking down electric motor (mono block/ centrifugal) from the existing position and inspecting the same, transporting to workshop for repairs and bringing it back. Cutting and removing the burnt out winding conductors, rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, oven drying, refixing in position checking the alignment along with pump set connecting up with the electrical system, testing and commissioning complete all as directed.
Material and labour for earthing complete with galvanised iron strip electrode 60x60cmx6mm thick, burried directly in ground(earth pit not less than 2.25metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected to galvanised earth lead strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to switchgear equipments/motors protected by 40mm dia light grade GI pipe upto a length of 7.5mtr including necessary excavation earth work, charcoal and salt PCC 1:3:6 type C1 for chamber 40mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT bars @ 100mm c/c both ways, 20mm dia GI watering pipe medium grade with funnel complete and testing complete all as directed.
Supply and Fix pan humidifier 1.5 KW complete all as specified and directed.
Supply and Fix heater duct size 1500 x 300 & 9 KW with three steps complete all as specified and directed.
All as per item No.90 above but of size 900x300 & 4 KW in two steps complete all as specified and directed. AMCC
M&L for serving of both indoor and out door units with coil cleaning chemical for cassatte ACs including checking of all elelctrical connectionsall as directed for the following capacity of plants Note: SERVICING TO BE DONE ONCE IN EVERY THREE MONTH)
1 x 2 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
1 x 3 TR Capacity Cassete Hi-wall split AC indoor unit Make : Daikin
2 x 4 TR Capacity Cassete Hi-wall split AC Indoor unit Make : Daikin
4 x 5.5 TR Capacity Package type AC plant
5 x 8.5 TR Capacity Ductable type AC
M&L for leak testing of the total refrigerant system of Package VRF type AC plants by pumping down the refrigerant to cylinder, flushing out the entire system arrest all leakages by replacing the damaged flare nuts, taflon washers, brazing, gaskets, o rings etc and leak test by supply and charging with Nitrogen gas ( N-2) under constant pressure of 250 - 300 PSI , watching the pressure for 24 Hrs for confirmation, flushing out the system vacuumising and charge the required qty of refrigerant and lubricant testing and commissioning the system all as directed for the following capacity of plants Note: Refrigerant & compressor oil shall be measured and paid separately under respective items
1 x 2 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
1 x 3 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
2 x 4 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
4 x 5.5 TR Capacity Package type AC plant
5 x 8.5 TR Capacity Ductable type AC
M&L for taking down unserviceable hermetically sealed compressor after disconnecting the suction/delivery lines and Supply & fixing hermetically sealed compressor of following capacities as per existing make, model & specification, including pressure testing, vacuumising and charging of refrigerant, testing and commissioning all as directed Make : Copeland/Danfoss/kirloskar/Blue star/Voltas (As per site requirement)
4 TR Note: Refrigerant will be measured and paid separately
Taking down unserviceable blower motor V-belt and S&F blower motor V-belt as per existing same Model & specification and suitable size to fixing with existing 25000LCFM - 02 Nos system capacity Package units all as specified and directed by the Engr-in-charge. Make:- FENNER/DUNLOP/NIRLON/DAIKIN
M&L for Repair/Servicing microprocessor based control panel with display including replacing wornout u/s single/three phase controllers, contractors, fuse, internal wiring as per existing same model & specification and suitable size for the following UNITSall as specified and directed by the Engr-in-charge
1 x 2 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
1 x 3 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
2 x 4 TR Capacity Cassete Hi-wall split AC out door unit Make : Daikin
4 x 5.5 TR Capacity Package type AC plant
5 x 8.5 TR Capacity Ductable type AC
S&F in replacement microprocessor based control panel alongwith single phase controllers, contractors and LED display as per existing same model & specification, controlling for condensing unit, compressor unit & blower of following units , all as specified and directed by the Engr-in-charge. Make:- Voltas/Bluestar/LG/Daikin
1 x 2 TR Capacity Cassete Hi-wall split AC out door unit
1 x 3 TR Capacity Cassete Hi-wall split AC out door unit
2 x 4 TR Capacity Cassete Hi-wall split AC out door unit
4 x 5.5 TR Capacity Package type AC plant
5 x 8.5 TR Capacity Ductable type AC
Removing the chocked unserviceable copper refrigerant tubing and S&F copper refrigerant tubing for the following sizes (outer dia) including suitable joints / branch connectors and distributers with flare nuts/brazing for indoor & outdoor units as required at site complete all as specified and as directed.
(a) 6.4 mm to12.7 mm
(b) 15.9 mm to 22.2 mm
M&L for rigid PVC conduit (medium grade) size 20 to 32 mm dia for water drain out line for Package type AC plant, laid on walls, ceiling, in floors with clamping/fixing mtrls complete all as specified and directed.
All as per item 99 above but size 40 mm dia.
M&L for preparation of surfaces by scrapping and removing rusted portion with wire brush and applying one coat of Red-oxide primer and two coats of synthetic enamel paint by spray method of the following capacities complete all as specified and directed
1 x 2 TR Capacity Cassete Hi-wall split AC out door unit
1 x 3 TR Capacity Cassete Hi-wall split AC out door unit
2 x 4 TR Capacity Cassete Hi-wall split AC out door unit
4 x 5.5 TR Capacity Package type AC plant
5 x 8.5 TR Capacity Ductable type AC
Removing the unserviceable thermostat expansion valve /capillary from the evaporating unit and S&F thermostat expansion valve/capilary of following capacities including cutting and brazing complete all as specified and directed by Engr-in-charge.
1 x 2 TR Capacity Cassete Hi-wall split AC out door unit
1 x 3 TR Capacity Cassete Hi-wall split AC out door unit
1 x 4 TR Capacity Cassete Hi-wall split AC out door unit
4 x 5.5 TR Capacity Package type AC plant
5 x 8.5 TR Capacity Ductable type AC
S&F in replacement for the following unserviceable spare parts for cassatte acs of any make & model all as specified and directed
Contactor rated current AC 3Ph, 9 Amps, coil voltage 230 V AC, 50Hz, capacity as per existing specification
Contactor rated current AC 3Ph, 18 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification
Contactor rated current AC 3Ph, 25 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification
Relay switch of range 4 to 6.5 Amps
Relay switch of range 6 to 10 Amps
Relay switch of range 9 to 14 Amps
Relay switch of range 13 to 21 Amps
LED Indicator lamps of colors R / Y / B
HRC fuse 2.5 to 10 Amps
HRC fuse 16 to 32 Amps
M&L for repair to unserviceable with cord/cordless PCB remote control unit of for indoor unit of Casettee AC of cap 2 to 4 TR including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed
S&F in replacement Outdoor Sensors suitable for Hi-Wall split Type AC for 2 TR to 4 TR same as per at site
S&F in replacement condenser fan blade suitable for Air Cooled condenser of following capacity
2 to 4 TR Capacity
Maintenance of Hot water generator 54 KW and complete testing all as specified and directed by the Engr-in-charge :- Note : 1) spares like heaters and controls will be paid separts Make : Rapicool
supply and fixing of thermostate
supply and fixing of 3/2 kw heater
supply and fixing of suitable size contactor
supply and fxixng of indicator
supply and fixng of dial type themometers
supply and fixng of dail type presssure guage
supply and fixing of 50mm butter fly valve
servicing of various capcity and make OF UPS 10 kva/20kva/30 kva
UNITY ENGINEERING TRADERS
CHITRA ENGINEERING CORPORATION
SUN LIGHT HOUSE
S.S.ENGINEERING CORPORATION
Bismi Engineering
BHAGYARAM ENTERPRISES
omsai thermax engineers
SRI SAI ENTERPRISES
Maruthi international
M/S GDR CONSTRUCTIONS
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .