Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹10.6 L+₹1.0 L (11.0%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹16.3 L+₹6.8 L (70.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Sept 2020, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda, Military Engineer Services, Bathinda Mil Station - 151004
REPAIRS, MAINTENANCE OF DG SETS AND CONNECTED ITEMS INSTALLED AT WATER SUPPLY INSTALLATIONS UNDER GE (U) BATHINDA AT BATHINDA MIL
2020_MES_367783_1
CA NO CWE BTD 33 2020 21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Station
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Utility Bathinda
₹30,000
Yes
29 Sept 2020
10 Aug 2020
18 Sept 2020
10 Aug 2020
16 Sept 2020
4 Sept 2020
10 Aug 2020 - 18 Aug 2020
Amount
M&L for 'B' check of DG Sets of capacity 20KVA to 63KVA complete as per following :-(i)Draining out engine/lubricant oil, flushing including filling fresh oil after drain out old oil by skilled tradesman of DG set including replacement of oil pan /chamber gasket. (ii)S& F in replacement lubricant oil filter element. (iii)S&F in replacement fuel filter element. (iv)S&F bypass filter element. (v)checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirment.
All as per Srl item No 1.00 above but DG Set of capacity 100KVA to 200KVA. (Make Kirloskar).
All as per Srl item No 1.00 above but DG Set of capacity 320KVA (Make Cummins).
Taking out the self starter (24 Volt) of DG Set capacity 320 KVA (Make-Kirloskar) and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only)
Taking out the self starter (24 Volt) of DG Set capacity 200 KVA (Make-Kirloskar) and shifting to workshop for rewinding of armature including replacement of unserviceable bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only )
Taking out the self starter (24 Volt) of DG Set capacity 100KVA (Make-Kirloskar) and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only)
Taking out the self starter (12 Volt) of DG Set capacity 20KVA to 63 KVA, (Kirloskar make) and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only)
Taking out the charging alternator of DG Set capacity 320KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only).
Taking out the charging alternator of DG Set capacity 200 KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only).
Taking out the charging alternator of DG Set capacity 100 KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only).
Taking out the charging alternator of DG Sets of capacity 20 KVA to 63 KVA (Make - Kirloskar) and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete all as specified. (Note:-Spares replaced shall be measured and paid separately under relevent item here in after as supply only).
Servicing of radiator assembly of DG Set 200 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing complete and making it leak proof including replacement of worned out tubular hoses alongwith clip etc complete all as specified and directed.
Servicing of radiator assembly DG Sets 20 KVA to 63 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified.
Servicing of radiator assembly DG Sets 100 (Make - Kirloskar) and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified and directed.
S&F in replacement of air cleaner filter for DG Set capacity 320 KVA (Make- Kirloskar) complete all as specified.
S&F in replacement of air cleaner filter for DG Set capacity 100 KVA (Make- Kirloskar) complete all as specified
S&F in replacement of air cleaner filters for DG Set capacity 20 KVA to 62.5 KVAcomplete all as specified Make Kirloskar
S&F in replacement of air cleaner filters for DG Set Cap 200 KVA (Make-Mahindra) complete all as specified.
Opening the coupling of DG Set of capacity 320 KVA (Make- Kirloskar) the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified.
Opening the coupling of DG Set of capacity 20 to 63 KVA, (Make -Kirloskar) dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified.
Opening the coupling of DG Set of capacity 100 KVA, (Make -Kirloskar) dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified.
Opening the coupling of DG Set of capacity 200 KVA, (Make -Cummins.) dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified & directed.
Servicing of fuel pump /hand pump assembly to make it fully fuctional and fixing it to its original position of DG Set in any capacity including replacement of necessary filter element completes all as specified.
Repairs and maintenance of FIP including replacement of Plunger, Governor kit with pin, Nozzles P type, Head ball guide kit, Head sheet (set of 12 piece) Rock rod, Rollar bearing, Oil seal, Piston pin, Gasket kit and sleeves complete all as specified and directed for DG Set capacity 20 KVA to 63.5 KVA. (Make-Kirloskar/ Cummines/ Mahindra)
All as per item No 24 above but DG set capacity 100 KVA.
All as per item No 24 above but DG set capacity 200 KVA.
M&L for calibration of fuel injector assembly of DG Set of 100 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as specified.
All as per item No 27 above but DG set capacity 200 KVA.
M&L for cleaning of diesel tank of DG Set of any capacity including replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
S&F in replacement of AVR complete all as specified and as directed for DG Set of capacity 20 KVA to 63.5 KVA .Model No.(i)CS3C0 14D1568-H (ii)LBS3K14L19548-H(iii)ES3A014A1867D8.
M&L in replacement of AVR complete all as specified and as directed for DG Set of capacity 100 KVA(Model No.6BTA5.9G1-I ) to 200KVA(Model No. FS3M109J89152)
M&L in replacement of AVR complete all as specified and as directed for DG Set of capacity 320KVA Model No.(i) GS3C0110132632 (ii)GS3C010D101788
S&F high pressure oil pipe SS as per sample of DG Set of any capacity.
S&F Bentex wheel complete suitable for self starter.
Supply only battery Terminals Copper.(Positive & Nagative) complete.
Supply only battery Copper cable Red with plug of size 35 sqmm complete.
Supply only battery Copper cable Black with plug of size 35 sqmm complete.
Supply & pouring K cool super plus-50-50 PREMIX of 1 Ltrs sealed Packing all as specified.
Supply only engine oil for DG sets 20W/40 grade CRB plus into the oil sump complete (Make - Castrol)
Supply only Fuel pipe / Hose pipe for DG Set complete all as specifed.
S&F in replacement fan belt set suitable for DG Set of any capacity of existing size complete all as specified and directed by Engineer-in-charge.
S&F in replacement water pump assembly complete all as specified and directed by Engineer –in-charge.
S&F in replacement fan assembly along with hub suitable for DG Set of any capacity complete all as specified and directed by Engineer-in-charge.
M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI strip of size 32x6mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI strip upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified and shown in Electrical plate No. 3 of SSR Part-1 (PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit) including testing on completion complete.
S&F on load change over switch 800Amps, 415 Volts,FP including disconnecting electric connection and dismantling existing change over switch.
All as per item No 45.00 above but 630 Amp.
All as per item No 45.00 above but 160 Amp.
All as per item No 45.00 above but 125 Amp.
Disconnecting the battery 12 Volts 180 AH from the DG set shifting to workshop for further dismantling for repair/replacement of cells, plates, reconditioning, filling of electrolyte of required specific gravity and charging the battery, after repair shifiting the batteries from workshop to E/M installation fixing to the DG set and testing complete all as directed by Engineer-in-charge.
M & L for cleaning of DG sets including removing of oil greese and spot washing carefully with soda water preparation of old painted surface and painting to the canopy of DG sets of capacity 62.5 to 320 KVA with two coats of spray painting of approved make and colour of first grade paint and making SM/MES No as per existing all as specified and directed.
Supply only distilled water for lead acid battery all as directed.
S&F in replacement of megnetic pick up sensor for 320 KVA (Model No. GS3C010D101788) DG Sets (Make: Kirloskar) complete all as specified.
S&F in replacement magnetic pick up sensor for 100KVA (Model No.6BTA5.9G1-I )DG Set (Make: Kirloskar) complete all as specified.
S&F in replacement Governor Card for 320 KVA (Model No. GS3C010D101788) DG Set (Make: Kirloskar) complete all as specified.
S&F in replacement Governor Card for 100KVA (Model No.6BTA5.9G1-I ) DG Set (Make: Kirloskar) complete all as specified.
S&F in replacement display unit of 63 KVA DG Sets. Display Board features of micropressesor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure, Engine temp, lab oil temp, canopy temp, Battery voltage, Engine RPM, Engine Running Hrs, Fuel level indicator, %of tank capacity. (ii)Engine protection:-Low oil pressure, High/low battery voltage, High engine temp, low radiator coolant level, Engine over speed, Engine under speed, low fuel level in diesel tank, Battery charging indicator. (iii)Electrical parameter display:-voltage, line to line, line to neutral, DG load current, Gen load voltage, frequency, load power factor, KW, KVA (iv) Electrical protection:-Over voltage, under voltage, over KVA, over Current.
S&F in replacement display unit of 320 KVA DG Sets. Display Board features of micropressesor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure, Engine temp, lab oil temp, canopy temp, Battery voltage, Engine RPM, Engine Running Hrs, Fuel level indicator, %of tank capacity. (ii)Engine protection:-Low oil pressure, High/low battery voltage, High engine temp, low radiator coolant level, Engine over speed, Engine under speed, low fuel level in diesel tank, Battery charging indicator. (iii)Electrical parameter display:-voltage, line to line, line to neutral, DG load current, Gen load voltage, frequency, load power factor, KW, KVA (iv) Electrical protection:-Over voltage, under voltage, over KVA, over Current.
Dismantling the alternator of DG set, AC 3 Phase, capacity of 100 KVA, 440 Volt, 1440 RPM, 50 Cycle of any make and type from the DG set and after disconnecting electric cable connection and earthing etc and transportation to civil workshop and back for minor repair and rewinding the alternator stator after cleaning with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, proving all high grade material and class 'B' varnish for insulation, reassembling the complete alternator and re-fixing at site with electric cable connection, earthing and testing of DG set on full load at site after coupling with DG set up to entire satisfaction of Engineer-in-charge.
M/s Kataria Construction Company
Choice india
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .