Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹30.5 L+₹32,431.06 (1.07%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹35.9 L+₹5.7 L (18.9%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹41.1 L+₹10.9 L (36.1%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹49.3 L+₹19.1 L (63.2%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Major MK Yadav, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIRS AND MAINT OF EARTHING PITS, LIGHTENING ARRESTER, PANEL, DBS IN TECH AND DOMESTIC AREA AND ALLIED WORKS AT AF STN SALUA UNDER GE AF KALAIKUNDA
2024_MES_665254_1
C/8026/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹60,000
Yes
2 Nov 2024
11 Jul 2024
13 Sept 2024
11 Jul 2024
12 Sept 2024
25 Jul 2024
Amount
S&F in replacement of Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified.
Taking out old GI/aluminium/copper earth strip or relaying/ refixing the same existing strip with fastners of any size and type in any height and any location as directed by Engineer In charge.
Supply and fixing copper strip of size 20 x 3 mm as earth continuity conductor or main earthing lead fixed on and including "V" type porcelain insulator, 4 BM, heavy duty ( ceramic bus bar support insulator off white colour of suitable for mounting strip of 20 mm wide x 3 min thick) saddle to wall, roof conductors and bracing to down conductors above ground etc. as required 20 x 3 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge. Note : Insulators to be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip)
S&F for Test Point junction box of suitable size made of 3.00mm thick CRCA sheet, with terminal block, IP 66 weather proof including four hexagonal anticorrisove screws for out door installation including provn of Test points as per IS specifications of shape and size 75x75x25 mm drilled and screwed incl 3 nos 8 mm dia 25 mm long hex head screw, made out of phospher bronze mounted and fixed on box with suitable grouting arrangements Suitable nut bolts, washers of various size as approved, complete duly fixed with ground/earth/roof conductor rigidly .
Taking out old unserviceable GI/Copper earth plate/Chemical electrode from soft and hard soil from any location as directed by Engineer -in- charge.
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 3.0 mtr deep below ground level) with top edge of the plate not less than 2.4 mtr below ground level connected to copper strip 20 x 3.00 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt all around the plate upto 15 cm from the edges, in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction of inspection pit concrete pit in PCC (1:3:6) typeC 1, pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately)
Material & labour for chemical earthing complete with copper earth plate electrode 900 mm x 600 mm x 5.00 mm thick burried directly in ground (Earth pit not less than 3.0 mtr deep below ground level) with top edge of the plate not less than 2.4 mtr below ground level connected to copper strip 32 x 6.00 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling with marconite PREMIX (min qty 420 Kg) all around the plate upto 15 cm from the edges, in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction of inspection pit concrete pit in PCC (1:3:6) typeC 1, heavy duty polythelene cover, , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately)
Note for BOQ Srl No 6.00 and 7.00 : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with Bentonite , (4 bags of 25 Kg each ), for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986. (vii) The cost of Copper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil beyond the MoD land.
Supply and fixing Brass Copper lightening arrester 9.2 mm diameter and 915 mm in length with 5 spikes and base plate 8.5 x 8.5 cm for building protection coverage of 45 degress from the top point 1.85 m all as specified and directed by Engineer in Charge.
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.50m x 1.50m x 0.75m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 40 x 40 x 5 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar rated 600 Amps made of copper ETP grade pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories including taking out the existing one :
All as per BOQ Item No 10.00 here-in-before but of size 1.00m x 0.75m x 0.40m LT bus bar feeder pillar box with canopy but wth 4 Nos of bus bar rated 400 Amps made of Aluminium(HINDALCO) with the following incoming and outgoing accessories :- (A) Incoming MCCB 160 Amps rating, TP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 16 KA --- 01 Nos. (B) Outgoing (b) MCCB 100 Amps rating, FP ,415 V, AC, 50 HZ, adjustable thermal anf fixed magnetic setting Ics-100 % Icu , service breaking capacity 16 KA --- 2 Nos. Note:- (i) All MCCB/MCB should be of approved Make (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s (ix) Rate of panel include refixing of all cables in panel which are dismantle & taking out from old unserviceable panel.
M&L for brazing of copper earth strip including grinding and prepartion of existing earth strip as directed by the Engineer-in-charge.
Supply & fixing in repairs DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door , enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with and including 01 No MCCB 63 Amps 16 kA Ics=Icu=100%, 01 No MCB TP 40/63 Amps 10kA, 10 Nos MCB SP 6-32 Amps 10 kA, 250 Amp insulated copper bus bar for each phase, 2 shrouded Neutral bar, 2 Earth bar, cable ties for cable management, , reversible door provision, with colour coded interconnecting wire set including flushing and fixing DB box in neaty in wall complete all as specified and necessary connection with suitable wire. (Note : DB and switchgear shall be of same make)
Supply & fixing in repairs DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 4 way, double door , enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with and including 01 No MCCB 63 Amps 16 kA Ics=Icu=100%, 01 No MCB TP 40/63 Amps 10kA, 5 Nos MCB SP 6-32 Amps 10 kA, 250 Amp insulated copper bus bar for each phase, 2 shrouded Neutral bar, 2 Earth bar, cable ties for cable management, , reversible door provision, with colour coded interconnecting wire set including flushing and fixing DB box in neaty in wall complete all as specified and necessary connection with suitable wire. (Note : DB and switchgear shall be of same make)
Supply & fixing in repairs DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 8 way, double door , enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with and including 01 No MCCB 63 Amps 16 kA Ics=Icu=100%, 01 No MCB TP 40/63 Amps 10kA, 5 Nos MCB SP 6-32 Amps 10 kA, 250 Amp insulated copper bus bar for each phase, 2 shrouded Neutral bar, 2 Earth bar, cable ties for cable management, , reversible door provision, with colour coded interconnecting wire set including flushing and fixing DB box in neaty in wall complete all as specified and necessary connection with suitable wire. (Note : DB and switchgear shall be of same make)
Cleaning the vegetation incl grass, bushes, small trees and all vegetation growth complete including digging out roots of bushes around installation/sump/OH tanks/bldgs/valve chambers ncl levelling the surface by removing debries outside of MOD Land as directed.
TRINITY ECO TECH SOLUTIONS, PROP-ASWINI KUMAR DEHURI (BID ID -3085283)
I.S.ENTERPRISE (BID ID -3092619)
M/s Tekcon International (BID ID -3081183)
Dilip Enterprise (BID ID -3082034)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .