GE NORTH DELHI CANTT
GE NORTH DELHI CANTT-10
REPAIR REPLACEMENT TO CERTAIN BR WORK IN OFFRS JCOS ORS MD ACCN AND OTM ACCN UNDER AOR OF AGE BRI UNDER GE NORTH DELHI CANTT10
2026_MES_797175_1
GE/NORTH-161/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT
₹98,000
Yes
4 Nov 2026
4 Nov 2026
26 Nov 2026
4 Nov 2026
24 Nov 2026
18 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of plain cement concrete (unreinforced) of any thickness of any description and in any position not specifically provided for complete all as specified and as directed. | 2 | cum | - | - |
| 2 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint free area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors over 15mm thick screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in coloured cement.including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed. | 200 | Sqm | - | - |
| 3 | Ditto- but in vertical surface as skirting, dado and risers to steps over and including10 mm thick rendering/backing coat in cement mortar 1:4 all as specified and directed. | 20 | Sqm | - | - |
| 4 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors over 15mm thick screed bed in cement mortar 1:6 set and jointed in neat cement slurry and pointed in coloured cement. including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed. | 60 | Sqm | - | - |
| 5 | M&L glazed ceramic coloured tiles in vertical surface area of each tile 0.07 to 0.15 Sqm each set and jointed in neat cement slurry and pointed in white or coloured cement to match incl rendering 10mm thick in CM (1:4) and finished rough, complete including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified & directed. | 150 | Sqm | - | - |
| 6 | S&F for coloured non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors/skirting etc set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match complete including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed | 200 | Sqm | - | - |
| 7 | Ditto- but in vertical surface as skirting, dado and risers to steps over and including10 mm thick rendering/backing coat in cement mortar 1:4 all as specified and directed. | 20 | Sqm | - | - |
| 8 | M&L for providing 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregates as in leveling course of floor rough surface to receive floor tiles complete all as specified. | 260 | Sqm | - | - |
| 9 | M&L Granite 12-18 mm thick colour as approved ( of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed of granite over 15mm thick screed bed in cement mortar 1:6), including moulding of edge of granite.all as specified and directed including dismantling old slab/tile incl bedding comlete all as specified and as directed. | 15 | Sqm | - | - |
| 10 | M&L for applying two coats of Oil Bound Distemper on old plastered/unplastered surface of wall using Airless spray technology withmax working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower .
Note - Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer over waterproof cement based putty @ 1Kg(undiluted) per sq mtr of average thickness 1mm of Asian Paints or its equivalent over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete all Sanding of the putty surface with Asian Paints Tru Care Wall Sander :-01H-01 or equivalent (having mechanical vaccume mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above having dia of 7"/9" to make the surface free from dust etc by skilled labour. Step 1- Mix the putty powder by adding 40-50% water and mix it with Asian Paints Trucare Putty mixer (Trucare Putty mixer with min 1400 W power having mixer rod of industrial stell grade 45 with the mixing capacity of min 2.5 kg putty per minute). Step 2- Apply the first coat the prepared mixer with the help fully automatic airless spray machine of putty application of Asian Paints Trucare Grace Spray Machine (Model:; EH 230 DI) or equivalant having a DC electric motor of 3.3 KW having flow speed of max 6 ltrs per minutes with a miximum pressure 230 bar having maximum tip size 0.041" Step 3) Allow 6-8 hrs time to dry the putty surface incl Complete removing of existing treatment by scrapping with Asian Paints TruCare Wall Sander: L- 01/H-01 (having mechanical vacuum mechanism) or equivalent having RPM not less than 1500, sanding pad of 80 Grit having dia of 7" to 9" to make the surface free from dust, loose paint etc. by skilled labour complete all as specifiec and as directed. | 5,250 | Sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Gen161.pdf
Tender Documents • 0.73 MB
BOQ_894192.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .