| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC BEING L1 AND OVERALL REASONABLE | |
| 2 | L2₹43.0 L+₹1.1 L (2.56%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical REJECTED BEING NOT ENLISTED IN CATEGORY b (i) |
Tender Value
₹48.5 L
EMD Value
₹97,100
Closing Date
7 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
ADD/ALT TO WINDOW, DOORS AND JOINERY WORKS OF KAKOLI (P-1111) BLDG AND ADD/ALTN AND IMPROVEMENT OF ELECTRICAL HYGIENE AT RT WORKSHOP (BLDG NO 387) AT NAD KARANJA
2022_MES_557805_2
8605/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KARANJA
ADD/ALT TO WINDOW, DOORS AND JOINERY WORKS OF KAKOLI (P-1111) BLDG AND ADD/ALTN AND IMPROVEMENT OF ELECTRICAL HYGIENE AT RT WORKSHOP (BLDG NO 387) AT NAD KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE (NW) KARANJA
₹97,100
Yes
2 Mar 2023
23 Nov 2022
10 Dec 2022
23 Nov 2022
7 Dec 2022
25 Nov 2022
23 Nov 2022 - 25 Nov 2022
Amount
M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made CPRI Approved LT cubical double door panel with roof canopy, indoor type, of Suitable size to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following
Location : RT Workshop (A) INCOMING FOR BUSBAR CHAMBER-1- (I) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 100 Amps Cat ref no. 4200 95 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 01 No. (B) OUTGOING FOR BUSBAR CHAMBER-1 (i) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 25 Amps Cat ref no. 4200 51 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 03 Nos. (C) INCOMING FOR BUSBAR CHAMBER-2 (I) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 100 Amps Cat ref no. 4200 95 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 01 No. (D) OUTGOING FOR BUSBAR CHAMBER-2 (I) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 40 Amps Cat ref no. 4200 52 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 03 Nos. (E) INCOMING FOR BUSBAR CHAMBER-3 (III) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 200 Amps Cat ref no. 4202 48 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 01 No.
M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made having CPRI Approved LT cubical double door panel with roof canopy, indoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following :
M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made CPRI Approved LT cubical double door panel with roof canopy, indoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following :
Supply & fixing, jointing, connecting & testing in trenches XLPE insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable cover, GI pipe & cable complete all as specified and directed :
4 core 16 Sqmm
3.5 core 35 Sqmm
3.5 core 95 Sqmm
3.5 core 400 Sqmm
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point complete all as specified and directed.
M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and directed. Note: Punned thickness shall be considered for measurement & payment purpose.
Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed.
Laying only un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm complete all as specified and directed.
M&L GI pipe light grade with all fittings complete laid in trenches for 80 mm bore of pipe complete all as specified and directed.
M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations ,filling and mass concrete includings necessary form work complete all as specified and directed.
M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point including testing on completion & dismantling/ taking out old existing earthing complete all as specified and directed Note :-(i) copper strip upto 7.5 m will be deemed to be inluded in quoted rate (ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit & the cost of the same is deemed to be included in rate quoted for above items. (iii) The rates quoted are also deemed to be included for cost of new test point as specified.
Supplying and fixing of following sizes of Hot dipped Galvanized CABLOFIL wire mesh cable trays and accessories. Cable tray shall be manufactured with a longitudinal 'T- welded' safety edge. Trays shall be constructed with 50 X 100 mm mesh configuration. All Accessories including couplers (EDRN fast coupling), are required of same finish as per site requirement. Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire cable trays must be designed with an optimum span of 1.5 m, taking into account the maximum carrying capacity authorised by the manufacturer. Assemblies with specific fire resistant properties must have an E30-E90 certificate. Rod dia must be from 3.9mm to 5.9mm for different sizes. Make-Legrand/Panduit/OBO
CF150/200 GC CABLE TRAY
EDRNDC - FAST SPLICE
KITASSTRDC COUPLING KIT
CE25DC-SQ SPLICE WASHER
BOLTS TRCC 6X20 DC
Supply,facbrication & installation of Support for trays fabricated with 25 mm X 25mm wide & 3mm thick SS 304 angle with hole of 12 mm dia for fixing cable trays at every 50mm. Drawing approval of said support is mandatory before fabrication as per site requirement. Support shall be fixed at every 1 mtrs interval complete all as specified and directed.
S & F SS Wedge Fastener M12x100mm complete all as specified and directed.
Assembling the Hot dipped Galvanized CABLOFIL wire mesh cable trays with above accessories and install the same with & including 'U' shape SS Strip of size 25 mm x 25 mm complete all as specified and directed.
M & L providing PCC 1:2:4 Type B0 (12.5mm graded aggredate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth, courses, string courses, lacing courses, parapets and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, kerbs, roof/chajja paddsing, water, troughts and the like including weathering, slightly rounded or chamfered agnles and throating, as directed including Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling mild steel work of any description not otherwise provided for Complete all as specified and directed.
M & L compound griders and stanchions, lattice driders, aerial masts, staging for water tanks and the lke including caps, bases, splices etc built up from two or more bem or channel sections or angle with plates, including all lattice bars, stiffners, gusset plates conforming to Gde Fe-410-W (Gde E-250 quality A) complete for overhead tank staging Complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1 : 6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete and preparation of new plastered surfaces of walls and applying two coat of colour wash of any colour or tint including taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M & L for green marble 18 to 20 mm thick (single piece table rubbed and polised) in step, jambs, pillars, window cills cooking platform and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admirable of pigment to match the shade all as specified
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area n exc. 1.5 Sqm each complete all as specified and directed.
All as per item above but exc 1.50 Sqm n.exc 4 Sqm complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,star lock, rubber beading complete all as specified and directed.
S&F Aluminium anodised grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC15) of approved design/pattern(DG 104), with approved standard section and fixed to existing window frame with CP brass/stainles steel screwnot less than 50mm and @ 200mm c/c, incl cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised alu standard section ( 28mm x 19mm x 2mm thick)around the opening, complete all as specified and directed.
S&F aluminium louvers with levers and locking arrangements suitable for fixing 100mm wide 4 to 6 nos frosted glass of size as per existing ventilator complete all as specified and directed
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50sqm each complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing complete in square nexc 0.50sqm each complete all as specified and directed.
S&F 4mm thick frosted glass, ordinary quality and glazing with oil putty of any size pane complete all as specified and directed.
M&L 20 mm thick polymer modified ready mix cement based plaster on external surfaces complete all as specified and directed.
M & L 15 mm thick ready mixed cement base plaster on internal surfaces on brick or concrete surfaces complete all as specified and directed.
M & L for preparation of newly or untreated plastered surface applying two coats of oil bound distemper (OBD) over a coat primer complete all as specified and directed.
M & L for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clean water & allow to dry. Fill visible cracks/ joints by chemistic crack seal caulking compound & allow to dry for 24 hours. Apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours. Thereafter apply 02 coats of chemistik PDS-50 (WB high build anti caronatin coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as per specified and directed.
S&F in repairs aluminium anodised alloy curtain rails 20mm dia fixing with brackets, stops, rollers etc. complete all as specified and directed.
Shri Krishna Trading Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .