| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹8.8 L | L1 | Accepted-AOC satisfied |
| 2 | L2₹9.0 LRejected-Finance CHATTAPADMAPUR RAMNAGAR DIST PURBA MEDINIPUR | PURBA MEDINIPUR | ₹9.0 L | L2 | Rejected-Finance bidder is not L1 |
| 3 | L3₹9.1 LRejected-Finance 119 MONOHAR PUKUR ROAD KOLKATA 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹9.1 L | L3 | Rejected-Finance bidder is not L1 |
| 4 | Rejected-Technical 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | - | - | Rejected-Technical insufficient deocuments |
| Sl No | Description | Qty | Unit | TAPAN ELECTRICS L2 | UNITED CONSTRUCTION SERVICE L3 | B. ENGINEERING CO. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Delivery of 230V,1-Ph, 50Hz, 2Tr. capacity Concealed Split Air Conditioning Machine along with IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 800CFM, Operating Mode:- Auto,Cool,Fan & Dry Mode, De-humidification:- Yes, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/Fujistu General)
(Allocation :-Department of Organon of Medicine-1 nos 2TR,Department of Surgery-1 nos 2TR,P.G. Pharmacy Laboratory-1 nos 2TR , Department of Pharmacy-1 nos 2TR , Department of Gynecology- Obstetrics - 1 nos 2 TR) | 5 | Nos. | 72,500 ₹3.6 L | 72,250 ₹3.6 L | 71,700 ₹3.6 L |
| 2.00 | Supply & Delivery of 230V,1-Ph, 50Hz, 1.5Tr. capacity Concealed Split Air Conditioning Machine along with IDU of rated Cooling Capacity:- 18000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32/R-22, Air Flow/IDU:- 600CFM, Operating Mode:- Auto,Cool,Fan & Dry Mode, De-humidification:- Yes, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/Fujistu General)
(Department of Repertory - 1 nos 1.5 TR , Phlebotomy room of the Hospital -2 nos 1.5 TR) | 3 | Nos. | 67,250 ₹2.0 L | 68,000 ₹2.0 L | 66,800 ₹2.0 L |
| 3.00 | Installation, Testing & Commissioning of Indoor & Outdoor unit of 1.5/2.0Tr. Concealed Split type after making hole in wall/Ceiling & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary downrod of suitable dia, fixing arrangement for indoor duly painted etc as per direction of the EIC. | 8 | Nos. | 2,600 ₹20,800 | 2,250 ₹18,000 | 2,500 ₹20,000 |
| 4.00 | Supplying & fixing of MS platform fabricated with M.S u-channel of 6 mm thick of size 75 mm x 40 mm x 40 mm at base, horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x 50 mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall for installation of outdoor unit of 1.5 TR Concealed split incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. The entire structure should be barricaded prorerly with suitable MS member & should be safe for ODU maintenance. Area of the platform is 2Mtr. x 1.2Mtr.or as per Machine configuration & load with adequate service access as per direction of EIC
Structural design should be approved by E.I.C. | 8 | item | 9,250 ₹74,000 | 8,980 ₹71,840 | 9,000 ₹72,000 |
| 5.00 | Supply and fixing of AI powder coated continuous Grill (Make- Premier, Dynacraft/ EIC approved.) | 7 | Sq. mtr. | 3,980 ₹27,860 | 3,940 ₹27,580 | 4,000 ₹28,000 |
| 6.00Supply & Laying of soft drawn Copper pipe line with 0.6 mm or 0.7 mm (min) thick for Liquid Line and Suction Liine between ODU and IDU with fittings, elbows, bends, supports & brackets (Make-Ryoku/Hitachi/Nippon) | ||||||
| 7.00 | Liquid Line 1/4" (6.35mm) Dia or as per manufacturer specification) | 100 | RM | 280 ₹28,000 | 276 ₹27,600 | 260 ₹26,000 |
| 8.00 | Gas Line/Suction Line 5/8" (15.88mm) Dia or as per manufacturer specification) | 100 | RM | 490 ₹49,000 | 495 ₹49,500 | 450 ₹45,000 |
| 9.00Supply & Fixing Pipe Insulation of Liquid Line and Suction Liine with 9 mm thick nitrile rubber tube also raping the insulation & copper wire with GKB Gold non adhesive raping tape (Make:- Accoflex/ Armacell/Supreme) | ||||||
| 10.00 | Liquid Line 1/4" (6.35mm) Dia or as per manufacturer specification) | 100 | RM | 20 ₹2,000 | 30 ₹3,000 | 10 ₹1,000 |
Tender Value
Refer Docs
EMD Value
₹17,563
Closing Date
3 Jan 2026, 11:00 amClosed
EE-l CKHED PWD
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) Kolkata
SITC of AC machines along with allied El Works at different places at D.N. DE Homoeopathic Medical College and Hospital, Kolkata.
2025_WBPWD_967754_1
WBPWD/EE-I/CKHED/eNIT80/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
CENTRAL KOLKATA HEALTH ELECTRICAL DIVISION
Please refer Tender documents.
3 documents required · 3 mandatory
₹17,563
Central Kolkata Health Electrical Division
13 Apr 2026
4 Dec 2025
5 Jan 2026
4 Dec 2025
3 Jan 2026
27 Dec 2025
9 Dec 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.19 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2348231.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid