| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹49.7 LAccepted-AOC C O BABA GULKARI FLAT NO C 57 SHANKARRAO PADHYE APARTMENT WARDHA ROAD SAVITRI VIHAR SOMALWADA NAGPUR 440025 MH | NAGPUR | MAHARASHTRA | 440025 | L-1 | Accepted-AOC Being L-1 bidder. | |
| 2 | L-2₹51.0 L+₹1.2 L (2.50%)Rejected-Finance PLOT NO 113 GURUSANGAT DARBAR ROAD SINDHI COLONY KHAMLA NAGPUR 440025 | NAGPUR | MAHARASHTRA | 440025 | L-2 | Rejected-Finance Not being L-1 bidder. | |
| 3 | L-3₹51.2 L+₹1.5 L (3.03%)Rejected-Finance A 21 SEC 23 NOIDA GAUTAM BUDH NAGAR GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L-3 | Rejected-Finance Not being L-1 bidder. | |
| 4 | L-4₹51.7 L+₹2.0 L (4.08%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-4 | Rejected-Finance Not being L-1 bidder. | |
| 5 | L-5₹52.4 L+₹2.7 L (5.35%)Rejected-Finance | L-5 | Rejected-Finance Not being L-1 bidder. |
Tender Value
₹57.2 L
EMD Value
₹1.1 L
Closing Date
8 Sept 2020, 6:00 pmClosed
AGM(E-E), DBAI Airport, Nagpur
O/o AGM(E-E), Engg. Block, DBAI Airport, Nagpur-440005.
ARMO of E and M Installations at ATS Complex, NAV-AIDS, OTB and R. R. Station at DBAI Airport, Nagpur. (Year 2020-22)
2020_AAI_56053_1
AAI/NGP/E-E/ 20-21/05/Radar-AMC/NIT-03/
Open Tender
Electrical Works
Item Rate
712 days
DBAI Airport
Please refer e-NIT.
16 documents required · 16 mandatory
₹1,180
Yes
Airports Authority of India
₹1.1 L
Yes
9 Nov 2020
1 Sept 2020
14 Sept 2020
1 Sept 2020
8 Sept 2020
1 Sept 2020
1 Sept 2020 - 7 Sept 2020
Amount
SH: I - Operation and Maintenance
Annual maintenance contract of E&M Installations of ATS complex, R. R. station, NAV-AIDS & OTB (AAI Installations) at Nagpur Airport round the clock on all days including Sundays & holidays which involves operation, preventive / routine / breakdown maintenance, attending complaints, repairs with proper tools & plants, documentation etc. as per the contract terms and conditions and directions of Engineer-in-charge as required. (a) 01 No. Highly Skilled (Supervisor) (b) 04 Nos. Skilled (Electrician / Wireman) (c) 03 Nos. Un-skilled (Helper) Min. no of manpower to be deployed shall not be less than 08. (Please refer SCC Cl. No. 45 on page no. 153 of tender documents before quoting the rate)
Deployment of Document Assistant cum Computer Operator (Highly Skilled) with adequate knowledge of software such as MS Office / Data Entry / Inventory Management / SAP Entry i/c DTP works on all days except on Sundays etc. as required.
Deployment of following manpower at site for carrying out various operation and maintenance works to meet the actual site requirements as and when required.
Electrician (Skilled)
Helper (Un-Skilled)
SH: II - Minor Repairs & Maintenance Works
Filtration of insulating oil of 2 Nos. 500 KVA Transformers (Oil tank capacity - 925 Litres along with tap changer, capacity - 210 Litres each) & 3 Nos. Voltage stabilizers (Capacity - 100 Litres each) at different locations including de-hydration, testing of transformer with tap changer, transformer oil (as per IS 1866-2017) & commissioning as per relevant IS code & submission of test reports etc. complete as required. (Total Oil Quantity - 2570 litres).
Servicing, testing & commissioning of 630 Amps VCB installed at radar power house etc. complete as required.
Servicing, testing & commissioning of 800 Amps ABB make ACB from OEM authorized service dealer including testing of Microprocessor based relay unit complete as required.
Testing and Calibration of existing relays installed in HT panels at radar power house including co-ordination of tripping timing as per standard practice and demonstration through current injection and submitting test reports etc. complete as required. Over Current / Earth fault Relay - 04 Nos. Supervision Relay - 04 Nos. Lockout Relay - 04 Nos.
Calibration and testing of Buchholz Relay for 11/0.433kV indoor, oil cooled 500 KVA transformer and submission of test reports as required.
Supply of Insulating oil confirming to relevant IS Code (IS 335) and topping up in the existing transformers as required.
Fault Locating & Cable Testing Job work by deploying Cable Fault Locator Machine for LT Cables as per direction of Engineer-in-charge etc. complete as required.
Fault Locating & Cable Testing Job work by deploying Cable Fault Locator Machine for HT Cables as per direction of Engineer-in-charge etc. complete as required.
SH: III - Supply of Spares (As & When Required)
AMF Relay with LCD Display similar to Make: C&S, Model: EC 2, O/P Contact Rating: 250 VAC, 4A; Voltage Input Range - UAN: 50 - 300 VAC; Aux. Supply - Uv : (7 - 35) VDC; Frequency - 50/60 Hz.
Power Contactor - 4 Pole, 700 A, similar to Make: C&S, MODEL NO. LC1FDPM5004A with 220 volt AC coil (Code No. M7).
4 Pole, 630 Amps MCCB with Icu=50 KA, Ics = 100% Icu & Electronic Trip Unit / Microprocessor Based Release similar to Make: ABB, TMAX T5S (Code - 1SDA054408R1) 630 with PR 221 DS-LS/I trip unit.
SH: IV - Execution of Works as per CPWD DSR (E&M) 2018, DAR (E&M) 2018 & Latest CPWD Specifications as & when required.
CPWD DSR (E&M) 2018 - Chapter 01 to 10 & 14 The rate shall be quoted for this item as per examples given below- • Please refer clause 47 of SCC page No. 165 before quoting rates for this item. • If bidder wants to quote the rates at par with rates of DSR-2018 (E & M), then bidder has to quote 1.00 in the rate column. • If bidder wants to quote the rates 10% above the rates of DSR-2018 (E & M), then bidder has to quote 1.10 in the rate column. • If bidder wants to quote the rates 10% below the rates of DSR-2018 (E & M), then bidder has to quote 0.90 in the rate column.
M/s BHARAT ELECTRIC, NAGPUR
Sew Engineering Works Pvt Ltd
Manish Electricals
S. N ELECTRICALS
M/s V.R. Associates
PAN POLAR ENGINEERS PVT. LTD.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .