Rewiring of Railway Quarters in the jurisdiction of SSE/PS/DKZ
37-R1-SRDEE-G-DLI-2025-26~NR
37-R1-SRDEE-G-DLI-2025-26
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹2.4 L
19 Dec 2025
26 Nov 2025
5 Dec 2025
A-Rewiring of Railway Quarters in the jurisdiction of SSE/PS/DKZ
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 1 with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 CPWD DSR (E&M) 2022 Item No. 1.10.1 Group A
Supply and recessing/fixing of PVC conduit pipe of 25mm size conforming to IS:9537 Part-III:1987/IEC:60614-2-2 (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement.
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single 3 core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per Tech Spec-I, including connections, testing and commissioning. Size = 1x2.5 sq.mm
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single 4 core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per Tech Spec-I including connections, testing and commissioning. Size = 1x4.0 sq.mm
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single 5 core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required as per Tech Spec-I including connections, testing and commissioning. Size = 1x6.0 sq.mm
Supply of brass Batten/Angle Holder conforming to IS : 1258-2005 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 CPWD DSR (E&M) 2022 Item No. 1.34
Supply of ceiling rose, 3 plate conforming to IS : 371-1999 (or Latest Version) & 7 installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 CPWD DSR (E&M) 2022 Item No. 1.33
Supplying & fixing suitable size GI box with modular plate and cover in front on surface 8 or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc as required.( For AC's) and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 1.57
Supplying and fixing of Bell Push modular switch/socket on the existing modular plate 9 & switch box including connections but excluding modular plate etc. complete as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 Item No. 1.24.8.
Supplying and fixing suitable size GI box with modular plate and cover in front on 10 surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6A modular switch, connections etc as required. as per IS, IE rule & site requirement of reputed make conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on 11 surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16A modular switch, connections etc of reputed make as required. as per IS, IE rule & site requirement conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.32.
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 245 Cum/Min , 350 RPM 12 (tolerance as per IS : 374-2019 or latest),THD less than 10%,suitable for electronic regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. It shall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall be approved by railway conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) Vol.II 2025 Item no. 2.2.4.
Supplying and fixing two module stepped type electronic fan regulator on the existing 13 modular plate switch box including connections but excluding modular plate etc. of reputed make complete as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.25
Supply, fixing, testing and commissioning of LT distribution board recessed mounting double door type made up of CRCA sheet sheet with anti corrosion treatment, IP 54 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032 & IS/IEC:61439 of make ABB, Havells, Siemens, L&T, Schneider, Legrand, C&S or equivalent with 14 following items of matching make to be fixed in distribution board, confirming to IS/IEC:60898-1:2002 or latest, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 deagree opening, cement spill protection, detechable gland at top and bottom and short link for MCBs." 40A 2P RCBO 30/100 mA= 01 No. (Incoming) 6-32A MCB SP ""C"" Series =18 Nos. (Outgoing).
"Supply, fixing, testing and commissioning of LT Block distribution board Surface mounting double door type made up of CRCA sheet with anti corrosion treatment, IP 65, phosphatised powder painted, (MCCB - Incoming & MCB - Outgoing) comprising with the following MCCB's fixed in it and bus-bar arrangement conforming to IS/IEC:61439 (or latest version) IE rules and site requirement. It should be dust and vermin proof, conforming to IS/IEC:60898-1:2002 or latest and powder coating as per IS:13032. It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal , reversible door with 180 deagree opening, cement spill protection, detechable gland at top and bottom and short link for MCBs." 125A MCCB 4P 36 kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) 40A MCB DP ""C"" Series =04 Nos. (Outgoing).
"Dismantling of existing electrical wires, fittings, switches, socket, ceiling fans etc from 16 the site and transport to all these materials to the store. All released materials shall be property of railway. Contractor will submit all materials to general store at SSB or as decided by the railway administration. Note : Conventional light fittings shall be dismantled and replaced only after completion of codal life" Unit = Each Point
Dismantling of existing old distribution board consicting of MCCBs/MCBs, Busbar, 17 electrical cables etc complete with outer metal box and associated supply cable from the site and transport to all these materials to the store. All released materials shall be property of railway. Contractor will submit all materials to general store at SSB or as decided by the railway administration.
Supply, fixing, testing and commissioning of LED light luminaire, having system 18 wattage 1x18 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-III attached or latest.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV 19 grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS:1255 & detail drawing approved by competent authority conforming to CPWD General Specifications for Electrical Works Part-II External - 2023, CPWD DSR (E&M) 2022 Item no. 7.1.1. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV 20 grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS:1255 & detail drawing approved by competent authority conforming to CPWD General Specifications for Electrical Works Part-II External - 2023, CPWD DSR (E&M) 2022 Item no. 7.1.2. Above 35 sq. mm and upto 95 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 21 including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS:1255 & detail drawing approved by competent authority as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023, CPWD DSR (E&M) 2022 Item no. 7.2.1. Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation 22 including excavation, sand cushioning, protective covering and refilling the trench etc as required as per IS:1255 & detail drawing approved by competent authority as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023, CPWD DSR (E&M) 2022 Item no. 7.2.2. Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable 23 of 1.1 KV grade of following size on wall surface/cable tray as required as per IS:1255 & IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023, CPWD DSR (E&M) 2022 Item no. 7.7.1. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable 24 of 1.1 KV grade of following size on wall surface/cable tray as required as per IS:1255 & IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023, CPWD DSR (E&M) 2022 Item no. 7.7.2. above 35 sq. mm upto 95 sq mm and (clamped with 25x3mm MS flat clamp).
Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per 25 IS:3043 (latest version) to achieve earth resistance less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mmx 400 mm) on top,provision of earth plate, connections from earth electrode to switch gear/pole as per drawing.
Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per 26 IS:3043/1987 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Shifting of existing meter box with Supply & fixing of thermoplastic PS polystrene weatherproof, dust proof, environment friendly, halogen & silicon free hinged transparent meter box size 168x253x115 mm complete as per site requirement.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
TECHSPEC-II_1.pdf
ATTACHMENT
TECHSPEC-III_1.pdf
ATTACHMENT
TenderDocument37-R1-SRDEE-G-DLI-2025-26.pdf
ATTACHMENT
explanatorynote37r1.pdf
ATTACHMENT
SpecialConditionofContractof37-R1-SRDEE-G-DLI-2025-26upload.pdf
ATTACHMENT
techspec1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .