Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹42.5 L+₹2.1 L (5.19%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹50.7 L+₹10.3 L (25.5%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | ICON AGENCIES L1 | GAYATRI ENTERPRISES L3 | NAVJEEVAN ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as specified and as directed by Engineer-in-Charge.
Note:
a) Ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule.
b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.
d) Spares required for repair to LED panel shall be measured and paid separately as "Supply only"
e) Pole Number should be mentioned in MB and ensure that the item is not under dfect liability period. | 205 | Each Job | 120 ₹24,600 Lowest | 250 ₹51,250 | 140 ₹28,700 |
| 2.00 | Supply only Electronic driver suitable for 90 to 120 W LED light fitting complete all as specified and as directed by Engineer-in-Charge | 37 | Each Job | 2,100 ₹77,700 Lowest | 2,300 ₹85,100 | 2,200 ₹81,400 |
| 3.00 | Supply only Electronic driver suitable for 70 to 80 W LED light fitting complete all as specified and as directed by Engineer-in-Charge | 39 | Each Job | 1,400 ₹54,600 Lowest | 1,900 ₹74,100 | 1,450 ₹56,550 |
| 4.00 | Supply only Electronic driver suitable for 30 to 60 W LED light fitting complete all as specified and as directed by Engineer-in-Charge | 41 | Each Job | 600 ₹24,600 Lowest | 1,500 ₹61,500 | 660 ₹27,060 |
| 5.00 | Supply only Surge protection device of capacity 10 KV suitable for LED light fitting complete all as specified and as directed by Engineer-in-Charge | 42 | Each Job | 550 ₹23,100 Lowest | 750 ₹31,500 | 580 ₹24,360 |
| 6.00 | Supply only Surge protection device of capacity 5 KV suitable for LED light fitting complete all as specified and as directed by Engineer-in-Charge | 46 | Each Job | 450 ₹20,700 Lowest | 650 ₹29,900 | 480 ₹22,080 |
| 7.00 | Supply only Lamp Holder suitable for 9-40 watt LED complete all as specified and as directed by Engineer-in-Charge | 42 | Each Job | 90 ₹3,780 Lowest | 200 ₹8,400 | 110 ₹4,620 |
| 8.00 | Supply only LED Lamp 40 watt complete all as specified and as directed by Engineer-in-Charge | 22 | Each Job | 700 ₹15,400 Lowest | 850 ₹18,700 | 770 ₹16,940 |
| 9.00 | Supply only LED Lamp 9 watt complete all as specified and as directed by Engineer-in-Charge | 20 | Each Job | 170 ₹3,400 Lowest | 200 ₹4,000 | 180 ₹3,600 |
| 10.00 | S&F in repair MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge | 8 | Each Job | 1,690 ₹13,520 Lowest | 2,200 ₹17,600 | 1,750 ₹14,000 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE Minniebay, Port Blair
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / MAINT PERIMETER LIGHTS, STREET LIGHTS, SECURITY LIGHTS, POST TOP LANTERNS, GARDEN AND GATE LIGHTS AND CERTAIN REPAIRS TO ROAD WAY ILLUMINATION SYSTEM INCLUDING LT/UG CABLES TIMER DBS / HIGH MAST / MID MAST LIGHTING SYSTEM AT MINNIEBAY AREA
2024_MES_654413_2
8405/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Minniebay, Port Blair
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹93,000
23 Aug 2025
2 Sept 2024
30 Sept 2024
2 Sept 2024
28 Sept 2024
9 Sept 2024
Amount
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as specified and as directed by Engineer-in-Charge. Note: a) Ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site. d) Spares required for repair to LED panel shall be measured and paid separately as "Supply only" e) Pole Number should be mentioned in MB and ensure that the item is not under dfect liability period.
Supply only Electronic driver suitable for 90 to 120 W LED light fitting complete all as specified and as directed by Engineer-in-Charge
Supply only Electronic driver suitable for 70 to 80 W LED light fitting complete all as specified and as directed by Engineer-in-Charge
Supply only Electronic driver suitable for 30 to 60 W LED light fitting complete all as specified and as directed by Engineer-in-Charge
Supply only Surge protection device of capacity 10 KV suitable for LED light fitting complete all as specified and as directed by Engineer-in-Charge
Supply only Surge protection device of capacity 5 KV suitable for LED light fitting complete all as specified and as directed by Engineer-in-Charge
Supply only Lamp Holder suitable for 9-40 watt LED complete all as specified and as directed by Engineer-in-Charge
Supply only LED Lamp 40 watt complete all as specified and as directed by Engineer-in-Charge
Supply only LED Lamp 9 watt complete all as specified and as directed by Engineer-in-Charge
S&F in repair MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge
S&F in repair loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type), IP 54 with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as specified and as directed by Engineer-in-Charge
M&L for painting to steel tubular pole 9 m long with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal and lettering the pole details with adhesive sticker of dia 125 mm with white letters (indicating pole No/location code) on blue background blackground etc complete all as specified and as directed by Engineer-in-Charge
M&L for preparation of old painted surfaces of 9 m long RCC poles incl removing oily/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.0 mtr height including applying a coat of white distemper on pole, pole coping and lettering the pole details with adhesive sticker of dia 125 mm with white letters (indicating pole No/location code) on blue background blackground complete all as specified and as directed by Engineer-in-Charge
Dismantling the existing old rusted /unserviciable Steel/RCC pole of any type including all fitting fixture complete all as specified and as directed by Engineer-in-Charge
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including dismantling old one complete all as specified and as directed by Engineer-in-Charge Note :- Earth work, cement concrete in foundation, coping etc shall be measured and paid separately under relevant item
Supply and erect steel tubular swaged poles Type 410 SP-55 11 meter long complete with cast iron base plate, finial taper plug, bolts, nuts & screws including dismantling old one complete all as specified and as directed by Engineer-in-Charge Note :- Earth work, cement concrete in foundation, coping etc shall be measured and paid separately under relevant item
Supply & erect minimum 7 m height above GL / foundation made out of Hot dip Galvanized single section octogonal pole with foundation base place of size 250x250x16 mm, foundation bolts 04 Nos of size 24 x 700/750 mm,with signle type arm bracket 1500 mm long, the pole shaft shall be tapered with single longitudinal welding and door opening for cable with 01 No MCB SP 6 Amp and 32 Amp connector and 03 run of 1.5 sqmm PVC wire for connecting street light fitting from MB including dismantling old RCC / rusted poles, complete all as specified and as directed by Engineer-in-Charge Note :- Earth work, cement concrete in foundation, coping etc shall be measured and paid separately under relevant item
M&L in repair for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted/ unserviceable cross arms complete all as specified and as directed by Engineer-in-Charge
S&F in repair PVC copper cable insulated shealthed of size 1.5 sqmm x 3 core complete all as specified and as directed by Engineer-in-Charge.
Supply and laying on wall/ on pole of CPVC pipes outer diameter 20mm SDR 13.5 pipes & plain CPVC SDR 11 fittings complete all as specified and as directed including dismantling old one complete all as specified and as directed by Engineer-in-Charge.
S&F in repair GI bracket for street lights made out of medium grade GI pipe 40mm dia, not less than 1.2 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed by Engineer-in -charge.
M&L in repair bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of GI clamp made out of 50x6 mm flat iron of suitable size for steel tabular poles complete all as specified and as directed by Engineer-in-Charge.
Dismantling LED light fitting of any existing make of capacity 90 to120 W ,strip opening the elctronic driver, LED panel , SPD , control wiring etc complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Dismantling LED light fitting of any existing make of capacity 70 to 80 W ,strip opening the elctronic driver, LED panel , SPD , control wiring etc complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and as directed by Engineer-in-Charge.
Dismantling LED light fitting of any existing make of capacity 40 to 60 W ,strip opening the elctronic driver, LED panel , SPD , control wiring etc complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete all as specified and as directed by Engineer-in-Charge. Notes for item Nos.24 to 26:- The quoted rate is not inclusive of taking down and spares required shall be measured and paid separately
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 90 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 72 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 60 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 45 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge
S&F in replacement of LED street light fittings comprising of epoxy powder coated housing,enclosed with glass cover in frame,with lumen output not less than 10800 lumens suitable watt for efficiency not less than 120 lumens/watt,having secondary optics,min wattage 25 watt ,with ingress protection IP 65/66 and potted electronic driver of miniumum IP 67 with THD less than 10 % ,CRI>80,P.F>0.9,IK>08 SPD of capacity 10 KV etc complete all as specified and as directed by Engineer in charge Notes for Item Nos:-27 to 31: (a) GI pipe bracket if required shall be measured and paid separately
S&F in replacement energy efficient post top light fitting on watt/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 25 W with THD less than 10%.CRI>80,P.F>0.9,IK>08,black case aluminium including all necessary wiring LED bulb,clamps,nut and bolts mounting accessories etc and providing connection complete all as specified and as directed by Engineer in charge
S&F in replacement energy efficient LED Garden light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long LED 10 W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring LED bulb , clamps, nut and bolts mounting acessories etc and providing connection complete all as specified and as directed by Engineer-in-Charge.
M&L in repair for earthing comlete with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground (earth pit not less than 2.25mtr deep belowGL) with top edge of earth plate not less than 1.5mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip 32 X 6 mm and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber , ms funnel, wire Gauge, 50mm thick RCC 1:2:4, type B1 earth pit cover with 6nos, 8mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule part-I complete all as specified and as directed by Engineer-in-Charge. NOTE : (i) Cost of GI earth strip and GI protection pipe upto 7.5 mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall be includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete.
S&F in replacement energy efficient LED Gate light fitting with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long 40W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring clamps, nut and bolts mounting acessories etc and providing connection all as specified and directed by Engineer-in-Charge.
S&F in replacement energy efficient LED bollard light fitting with IP 65 protection high quality integerated LEDs assuring soothing warm white light all night long 9W with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, black case aluminuim including all necessary wiring clamps, nut and bolts mounting acessories etc and providing connection complete all as specified and as directed by Engineer-in-Charge.
M&Lin repair radium reflective, water proof adhesive sticker of width not less than 100 mm wrapped around the street light pole of approved colour complete all as specified and as directed by Engineer-in-Charge.
S&F in repair of Service wire Al Conductor Weather Proof 6 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
S&F in repair for aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables :-
Taking down of old UG Cable of any size/core and any type complete from trenches/cable duct/on wall/roof carefully, identifying for faults, dismantling unserviceable cable and segregating serviceable cable for reuse complete all as specified and as directed by Engineer-in-Charge
Supply and laying in trenches ,fixed on walls,passing through pipes,jointing and testing of electric LT cables,PVC insulated ,PVC sheathed ,galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 V grade complete all as specified and as directed by Engineer-in-Charge Note: Earthwork/HDPE pipe/Straight through joints if required shall be measured and paid separately .Cable lugs,cable glands and necesssary insulation tape shall deemed to be included under quoted rate
4 Core 6 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
Supply & Laying in repair Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polythylene including coupler & bend with smooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge
Relaying/ Rerouting old serviceable UG cable of size 10 to 25 Sqmm any core retrieved from item No above in trench/pipe/DWC pipes /on wall /cable duct with necessary saddles/clamps of suitable size complete all as directed. Note: Earth work, DWC pipe/GI pipe shall be measured and paid separately as "Supply only"
S&F in repair GI pipe of medium grade 40 mm dia all fitting fixture for fixing with wall and road crossing etc. complete all as specified and as directed by Engineer-in-Charge
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed by Engineer-in-Charge
All as per item No.45 here in before but exc 1.5m or part there of in depth beyond 1.5 m depth complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and as directed by Engineer -in-Charge.
M&L for road cutting, removing of material , returning filling and pcc 1:2:4 for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe complete all as specified and as directed by Engineer-in -charge.
S & F in repair for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 25 Sqmm 3.5 core complete all as specified and as directed by Engineer-in -charge.
Suppy and laying in repair high mast lights Elastomer LT cables, PVC insulated, PVC sheathed, 2.5 Sqmm 3 core steel strip or wire armoured electric power cable with stranded copper conductor, 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: Thimbles and connectors complete where ever required shall deemed to be included under quoted rate
M & L for servicing of High Mast of less than 15 Mtrs height by lowering, checking, rectifying the defects, over hauling of winch drum assembly, motor including checking and replacing of gears, winch motor, wire ropes, trailing cable along with lugs, lubricating the moving mechanism and raising the high mast upto its height complete all as specified and as directed by Engineer in Charge. Note: The items gears, wire ropes and trailing cable shall be measured and paid as "Supply only"
Supply only gear mechanism complete all as specified and directed by Engr-in-Charge.
Supply only stainless steel wire rope 6mm dia (7/19 construction) complete all as specified and directed by Engr-in-Charge.
M & L for dismantling the defective induction motor of capacity upto 1 HP any make/class of insulation from foundation bed, disconnecting all electric supply connections, duly coupled with pump/compressor, trasnporting to workshop removing burnt out widing from stator/rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE /NDE bearings, insulation materials, varnishing , heating, greasing of bearings etc complete, re-assembling, testing and commissioning of following capacity motors Engineer-in-Charge Note: Terminal block,bearing of motor if required shall be measured and paid separately
M & L for dismantling of existing high mast/ mid mast pole of height not exceeding 16 m carefully by stip opening of all accessories such as winch, motor, fittings, control panel , cabling, wire rope , nut bolts etc complete and shifting it to nearby location not exceeding 1.0 KM with proper T&P such as crane and transportation complete and installing/errecting on foundation , re-installing control panel on CC foundation, re-assembling all dismantled accessories, fittings/fixtures complete, testing and commissioning Engineer-in-Charge Notes : (i) RCC/ PCC foundation/ Replacement of defective light fittings required for mid mast pole shall be measured and paid separately. (ii) Foundation shall be designed based on SBC of nearby building /location or otherwise SBC report shall be obtained from authorised consultant as approved by GE and cost for the same shall be deemed to be included under quoted rate
Supply & fixing in repair IP 65/66 thermoplastic-polycarbonate cable junction box of size 205X255X112mm with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of Two nos of GI calmp of size 25X3 mm including 40Amps connector, lugs and equivalent MCB Engineer-in-Charge
S&F all in one solar LED street light fittings comprising of epoxy powder coated pressed die cast aluminium / ABS (Acrylonitrile-butadiene-styrene) body, with lumen output not less than 4000 lumens suitable wattage for system efficiency not less than 160 lumens/Watt, with ingress protection IP 65/66, CRI>70, CCT 6500K, battery capacity 15 AH, battery volatge 3.2 V with poly crystalline solar panel with microwave based motion sensor complete and testing on completion including taking down old unserviceable street light fittings from any height complete all as specified and as directed by Engineer-in-Charge.
S&F Inverter type LED street light fittings comprising of epoxy powder coated pressure die cast housing with toughned glass cover in frame, with lumen output not less than 9000 lumens suitable wattage for system efficiency not less than 100 lumens/Watt, having secondary optics, min wattage 90 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, PF>0.95, CRI>70, CCT 5700K, SPD of capacity 10 KV, battery backup time upto 4 Hrs with minimum initial lumen reduced to 40% complete and testing on completion including taking down old unserviceable street light fittings from any heightall as specified and as directed by Engineer-in-Charge. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion including taking down old unserviceable flood light fittings from any height complete all as specified and as directed by Engineer in charge Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 19000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion including taking down old unserviceable flood light fittings from any height complete all as specified and as directed by Engineer in charge Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 11000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion including taking down old unserviceable flood light fittings from any height all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 19000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion including taking down old unserviceable flood light fittings from any height all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 23750 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 250 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion including taking down old unserviceable flood light fittings from any height all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
S&F in replacement LED aviation lamp of minimum 10 watts with total lumen output not less than 1000 lumens and suitable wattage for efficiency not less than 100 lumens / watt made up of die-cast aluminum housing with red polycarbonate dome for better illumination, Integral driver, Ingress Protection : IP65, protection against short-circuit, protection against surge, wide operating input voltage range 100 – 270VAC complete all as specified and as directed by Engineer in Charge.
S&F in replacement of LED bay light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame, (with total lumen output not less than 9600 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 80 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion complete all as specified and as directed by Engineer in Charge.
S&F in replacement of LED bay light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame, (with total lumen output not less than 14400 lumens and suitable wattage for efficiency not less than 120 lumens/Watt, having secondary optics, min wattage 120 watt, with ingress protection IP 65/66 and potted electronic driver of minimum IP 67 with THD less then 10%, CRI > 80, P.F> 0.9, IK> 08, SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed by Engineer in charge
S&F in repair connection and testing of MCB SP 6-32Amps Amps completion all as specified and as directed by Engineer in charge
S&F in repair of Service wire Al Conductor Weather Proof 10 Sqmm 2core complete all as specified and as directed by Engineer-in -charge.
S&F in repair Digital Timer with Analog time ,contactor pre wired Distribution Board complete time lite 40A 3 Pole 415 V complete all as specified and as directed by Engineer in charge
Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr around each pole upto 1.0X1.0Mtr from each pole coping of pole complete all as specified and directed by Engineer-in -charge.
M&L for wiring of unserviciable timer panel box complete and replacement of existing size of copper wire and copper lugs and testing complete all as specified and as directed by Engineer-in -charge.
S&F in repair contactors of capacity 40-63 A 3 Pole 415 V with 2NO+2NC complete all as specified and as directed by Engineer-in -charge.
S&F in repair NO/NC auxillary contacts of capacity 40A of 415 V complete all as specified and as directed by Engineer-in -charge.
S&F in repair digital timer switch, current capacity 16A, with 1 changeover complete all as specified and as directed by Engineer-in -charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in -charge.
M&L for reinforced cement concrete M30grade (Design Mix) including rafts,footingsfoundation beams,plinth beams,bases for columns etc basement slabs,under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed by Engineer-in -charge.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in fooundation complete all as specified and as directed by Engineer-in -charge.
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in coping of poles and stay including formwork complete all as specified and as directed by Engineer-in -charge.
M&L for mild steel TMT (CRS) bars 10mm dia and over, cut to length, bent to shape required, including cranking and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer in charge
M&L for mild steel TMT (CRS) bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer in charge
NAVJEEVAN ENTERPRISES (BID ID -3109061)
GAYATRI ENTERPRISES (BID ID -3117629)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .