| 1 | L1₹2.8 CrAdmitted-Finance | ₹2.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.1 Cr+₹35.5 L (12.7%)Admitted-Finance | ₹3.1 Cr+₹35.5 L (12.7%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical NEW NO 115 OLD NO 109 KAMARAJ NAGAR PUDUPATTINAM KALPAKKAM 603102 | KALPAKKAM | CHENGALPATTU | TAMIL NADU | 603102 | - | - | Rejected-Technical Disqualified |
| Sl No | Description | Qty | Unit | E-VERVE DESIGN L1 | GS CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00EARTH WORK EXCAVATION | |||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | 99.2 | Cum | 600 ₹59,520 | 300 ₹29,760 Lowest |
| 1.02PLAIN CEMENT CONCRETE | |||||
| 1.03 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 68.79 | Cum | 8,200 ₹5,64,078 | 7,200 ₹4,95,288 Lowest |
| 1.04MASONRY WORK | |||||
| 1.05 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) | 15.61 | Cum | 10,000 ₹1,56,100 Lowest | 12,500 ₹1,95,125 |
| 1.06RCC WORK | |||||
| 1.07 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 2.9 | Cum | 9,000 ₹26,100 Lowest | 14,000 ₹40,600 |
| 1.08 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | 3,331 | Kg | 120 ₹3,99,720 | 105 ₹3,49,755 Lowest |
| 1.09 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103
to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M30 grade with minimum cement
content of 350 kg /cum | 19.4 | Cum | 11,000 ₹2,13,400 Lowest | 14,000 ₹2,71,600 |
Tender Value
₹2.9 Cr
EMD Value
₹7.4 L
Closing Date
4 Feb 2026, 3:00 pmClosed
Deputy General Manager
Integrated vaccine complex, Survey no 192 195, Meleripakkam village, Chengalpattu - 603003
General Civil Works at Various Buildings in HLL Biotech Limited, Chengalpattu
2026_HBL_263828_1
HBL/GRL/CVL/CPT/25-26
Open Tender
Civil Works
Item Rate
60 days
HBL Chengalpattu
Please refer Tender documents.
17 documents required · 17 mandatory
₹8,850
Yes
HLL Biotech Limited
₹7.4 L
Yes
Online
12 Feb 2026
21 Jan 2026
5 Feb 2026
21 Jan 2026
4 Feb 2026
21 Jan 2026
28 Jan 2026
EARTH WORK EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
PLAIN CEMENT CONCRETE
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
RCC WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M30 grade with minimum cement content of 350 kg /cum
FORM WORK
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
PAINTING WORK
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade,including cost of scaffolding, labour, materials, tools and all incidental charges, complete as directed by the Engineer-in-Charge. One or more coats on old work.
Providing and applying interior and exteriorr waterproofing paint on existing walls over prepared surface, including application of one coat of primer (if required) and two coats of acrylic polymer based waterproof coating of approved make and shade, including all labour, materials, tools & plants, complete as per CPWD specifications and directions of Engineer-in-Charge.
Painting on walls/roof with acrylic emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams per litre, of approved brand and manufacture, including preparation of surface, application of one coat or additional coats wherever required to achieve an even shade and uniform colour, up to a height of 15 m, including cost of scaffolding, labour, materials, tools and all incidental charges, One coat complete as directed by the Engineer-in-Charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying interior waterproofing paint on existing internal walls over prepared surface, including application of one coat of primer (if required) and two coats of acrylic polymer based waterproof coating of approved make and shade, including all labour, materials, tools & plants, complete as per CPWD specifications and directions of Engineer-in-Charge.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a)after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece
Providing & Applying weather proof sealant on outer joints of approved make confirming to IS & directed by Engineer-in-charge. Sealant 25mmx10mm at joints
Application of 2 coats of a two-part Polyurethane (PU) paint (Glossy or Matte finish).
TILE WORK
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
FALSE CEILING
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Taking out existing tiled false ceiling comprising mineral fibre / gypsum / metal tiles (as existing) without damage, including dismantling of ceiling tiles, T-grid / aluminium framework, hangers and accessories as required, stacking serviceable materials at site, cleaning the tiles, and refixing the same tiles in position over existing or new aluminium T-grid framework, including replacement of damaged aluminium frames, hangers, clips and accessories wherever required, proper alignment and leveling, cutting and making openings for light fittings, air diffusers and services, and making good the surface complete as directed by the Engineer-in-Charge.
Providing and applying approved quality neutral cure, UV-resistant silicone sealant of approved brand and manufacture, suitable for internal/external use, including cleaning and preparation of joint surfaces, removal of dust, loose particles and contaminants, application of sealant in joints to required thickness and profile, tooling and finishing to smooth and uniform appearance, and ensuring durable, watertight and airtight sealing, complete as directed by the Engineer-in-Charge.
Removing existing damaged or deteriorated expansion joint material from floors/walls/roofs (as applicable), including cutting and taking out old joint filler, sealant, cover plates and accessories, cleaning the joint thoroughly to remove all loose material, dust and foreign matter, and stacking serviceable materials at site or disposing of unserviceable material as directed by the Engineer-in-Charge, complete.
Providing and fixing of expansion joint in RCC slabs including RCC, steel and filler material complete as per the direction of engineer in charge
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Repairing cracks in walls by opening the cracks in V-shape or U-shape as required, cleaning the crack thoroughly to remove loose particles, dust and foreign matter, applying bonding agent where necessary, and filling the cracks with approved crack filler / polymer modified mortar / epoxy or cementitious repair compound as specified, finishing the surface smooth to match the existing wall finish, curing complete, as directed by the Engineer-in-Charge
Providing and applying epoxy coving at wall–floor junction above finished tile level, forming a smooth concave radius of 50 mm, using solvent-free high-build epoxy mortar system comprising two component epoxy resin, hardener and graded filler, suitable for hygienic areas, resistant to chemicals and hospital-grade disinfectants, non-dusting, seamless and easy to clean, including surface preparation, compatible epoxy primer on tile and wall surfaces, coving formation, finishing/seal coat, curing, masking, and all labour, materials, tools, plant, cleaning, transportation and incidentals, complete as per manufacturer’s technical data sheets, confirming to the standars of ASTM C881, ASTM D4541, ASTM D4060 or equivalent and directions of the Engineer-in-Charge.
Providing and fixing frosted film in the fixed glass etc. Complete as per the direction of departmental officers
Providing and fixing tiled false ceiling of specified materials of size 595X595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size24X38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of sixe 24X25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center form of grid of 1200X600mm and secondary cross "T" of length 600mm and size 24X25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200X600 mm panel to form grids of 600X600 mm and wall angle of size 24X24X0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27X37X25X1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85X30X0.8 mm spaced at 1200 mm center to center along mainT, bottom exposed width of 24mm of all T-Sections shall be pre-painted with polyester paint,all complete for all heights as per specifications, drawings and as directed ny Engineer-in-charge.I Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
DOORS AND WINDOWS
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm
Fixing of existing door handles on wooden/metal/aluminium/UPVC doors, including alignment, tightening or refixing with screws, minor adjustments for smooth operation, testing, and making good the surface wherever required, complete as directed by the Engineer-in-Charge.
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 900 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Taking out existing window glass panes and removing old silicone sealant, removing the glass panels without breakage, thoroughly cleaning and washing the glass panes to make them clear and free from stains, smudges and contaminants, cleaning the glass edges and window frame surfaces to remove all sealant residues, dust and foreign matter, and refixing the same glass panels in position using approved quality neutral cure UV resistant silicone sealant, including replacement of damaged glazing bead where required, proper alignment, sealing on all sides, finishing smooth and uniform joints, and ensuring watertight and airtight fixing upto 15m height, including cost of scaffolding, labour, materials, tools and all incidental charges, complete as directed by the Engineer-in-Charge
Providing and creating vacuum insulation in existing double glazed vision panels by evacuating air from the cavity between the glass panes to form a near perfect vacuum for thermal insulation and heat reduction, including necessary drilling/port provision if required, vacuum evacuation using approved equipment, sealing the evacuation points with approved materials, resealing the glass edges, checking for leakage and ensuring airtight and watertight performance & placing Silica Bags inside the media to detect moisture content, complete as directed by the Engineer-in-Charge.
Dismantling door accessories such as hydraulic door closers, tower bolts, handles, stoppers, hinges, locks, etc., from wooden/metal/aluminium/UPVC doors, including unscrewing, removal without damage to door/shutter, making good the surface temporarily if required, and stacking the dismantled items properly at site, complete as directed by the Engineer-in-Charge
Providing & fixing stainless steel tower bolt of size 200 mm, ISI marked / approved make, on wooden/ metal/ aluminium/ UPVC door or shutter, including drilling holes, fixing with required screws, alignment, testing for smooth operation, and making good the surface complete as directed by the Engineer-in-Charge.
Providing & fixing stainless steel tower bolt of size300 mm, ISI marked / approved make, on wooden/ metal/ aluminium/ UPVC door or shutter, including drilling holes, fixing with required screws, alignment, testing for smooth operation, and making good the surface complete as directed by the Engineer-in-Charge.
Providing and fixing aluminium housing with EPDM / silicone gasket door bush of approved make and quality, suitable for sealing door openings, including supply of aluminium housing, EPDM / silicone gasket, cutting to required size, fixing in position with screws/fasteners, ensuring proper alignment and tight sealing, making good the surface wherever required, and testing for smooth and effective sealing maximum 1100mm length, complete as directed by the Engineer-in-Charge
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing Steel S.S- 304 (D) Door Pull Both Side Handle of 12 inch, one Set (2 Handles) ( best make of approved quality ) for Glass, Wooden or similar doors including necessary cutting and making good etc. complete
Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in-charge. With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing chromium plated brass handles with necessary screws etc. complete: 100 mm
PLUMBING AND SANITARY
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-white
Taking out of Health faucet as per the direction of site Engineer-in-charge
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge
Taking out existing rain water gutter pipes and providing and fixing square rain water gutter pipes of 150mm dia complete as per the direction of engineer in charge
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5. Rectangular shape 600x450 mm internal dimensions
Providing and fixing brass angle valve of approved quality, 15 mm nominal bore, chromium plated / polished finish, including all necessary fittings, jointing material such as teflon tape, testing for leakage, and fixing complete, as per CPWD specifications and directions of Engineer-in-Charge.
Providing and fixing PTMT Bottle Trap for Wash basin and sink,Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : White solid plastic seat with lid
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing SS grating of approved quality and colour: Circular type 100 mm nominal dia
Replacing existing health faucet and fixing new CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge
WATERPROOFING WORKS
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
DISMANTLING AND DEMOLISHING
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.66 MB
TEDOCIVILWORK.pdf
Tender Documents • 0.65 MB
BOQ_306104.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .