Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC R S PURA NEW PLOT SALEHAR R S PURA JAMMU JAMMU JAMMU KASHMIR 181111 | JAMMU | JAMMU AND KASHMIR | 181111 | ₹17.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹18.4 L+₹75,635 (4.29%)Rejected-Finance | ₹18.4 L+₹75,635 (4.29%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹18.7 L+₹1.1 L (6.36%)Rejected-Finance | ₹18.7 L+₹1.1 L (6.36%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹19.3 L+₹1.7 L (9.39%)Rejected-Finance | ₹19.3 L+₹1.7 L (9.39%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹19.8 L+₹2.2 L (12.3%)Rejected-Finance | ₹19.8 L+₹2.2 L (12.3%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Jun 2025, 6:00 pmClosed
GE SATWARI
GE SATWARI
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION,CEILING FANS,EXHAUST FANS,RE-WIRING AND ALLIED WORKS AT 166 MH AND RAIPUR SATWARI UNDER AGE E/M OF GE SATWARI
2025_MES_711976_1
GEJM-12/2025-26
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SATWARI
Class D Cat b(i)
9 documents required · 9 mandatory
₹500
GE SATWARI
₹70,000
Yes
28 Jul 2025
2 Jun 2025
2 Jul 2025
2 Jun 2025
30 Jun 2025
16 Jun 2025
Amount
Note :- 1. The work is meant for day to day maintenance based on complaints . The complaints are required to be attended / cleared on the same day of the reporting. However in exceptional case, if any complaint could not be attended on the same day,the same will be cleared within 48 hours of the reporting. If contractor fails to attend / clear the complaint within 48 hours, a penalty of Rs. 100/- per complaint per day will be imposed till the completion of complaint and recovery amount will be deducted from the RAR submitted by contractor.The T&P required shall be arranged by the contractor. 2. The contractor shall be provided with space for setting up maintenance cell at the specified location as per the directions of Engineer-in-Charge.The maintenance cell shall be manned by the contractor's supervisor responsible for collecting complaints from the concerned JE/AGE. A proper record of complaints will be maintained by the concerned JE duly signed by contractor. 3. The quoted rate of minor material like screws,nuts, insulating tape ,copper wire of different sizes upto 01 meter length required in the items of BoQ is deemed to be included in the respective item.
S&F in replacement switch piano, flush type, single pole, one way, 6 Amps, 240 V complete all as specified and directed
S&F in replacement bell push, flush type, 6 Amps, 240 V complete all as specified and directed
S&F in replacement buzzer ding dong, 240 V complete all as specified and directed
S&F in replacement socket outlet, two-in-one, 3 pin, 6 Amp, flush type,230 volts, AC supply complete all as specified and directed
S&F in replacement switch socket combination, two-in-one, 3 pin, 6 Amp, flush type,230 volts, AC supply complete all as specified and directed
S&F in replacement switch piano, flush type, single pole, one way, 16 Amps, 240 V complete all as specified and directed
S&F in replacement socket outlet, two-in-one, 3 pin, 6 & 16 Amp, flush type,230 volts, AC supply complete all as specified and directed
S&F in replacement switch socket combination,five-in-one, 3 pin, 6 & 16 Amp, flush type,230 volts, AC supply complete all as specified and directed
S&F in replacement stepped type electronic fan regulator, flush type,single phase, AC supply, 230 V complete all as specified and directed
S&F in replacement modular type switch, one way, 6 Amps ,1 module complete all as specified and directed.
S&F in replacement modular type socket,6 Amps, 2/3 pin combined 2 module complete all as specified and directed
S&F in replacement modular type socket,6A/16 Amps, 2/3 pin combined 2 module complete all as specified and directed
S&F in replacement modular type switch, one way ,16 Amps ,1 module complete all as specified and directed
S&F in replacement PVC plug top, 6 Amp,3 pin with easy grip, white, matt finish complete all as specifed and directed.
S&F in replacement PVC plug top, 15/16 Amp,3 pin with easy grip, white, matt finish complete all as specifed and directed.
S&F in replacement fan capacitor 2.15 mfd to 2.5 mfd complete all as specifed and directed.
M&L in replacement modular sheet cover plate with frame of size 8 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement modular sheet cover plate with frame of size 6 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement modular sheet cover plate with frame of size 3 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement GI/pressed steel terminal switch board of size 12 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement GI/pressed steel terminal switch board of size 6 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
M&L in replacement GI/pressed steel terminal switch board of size 3 module including necessary electrical connections as per existing point wiring complete all as specifed and directed.
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells etc & making good the disturbed surfaces of walls/ceiling, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit ,medium grade,of suitable size with all accessories such as bend, reducers, MS hooks including galvanised/pressed steel moduar terminal boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications.
All as per Srl item No 25. here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No.25 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No 25. here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board but below the switch board of light points in same vertical plane complete all as specified and directed
All as per Srl item No 22 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and directed
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor,drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit ,medium grade,of suitable size with all accessories such as bend, reducers, MS hooks including galvanised/ steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 3mm thick plastic laminated Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed . . Note:- Proper colour coding is to be followed as per IS specifications.
All as per Srl item No 30. here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board but below the switch board of light points in same vertical plane complete all as specified and directed
All as per Srl item No 30.here-in-before but for one socket outlet, 3 Pin 5 Amps, 230 Volts on independent board complete all as specified and directed
All as per Srl item No.30 here-in-before but for one three pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed
All as per Srl item No 30 here-in-before but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire complete all as specified and directed
S&F modular switch, one way 6 Amps , 1 module complete all as specifieds and directed .
S&F modular switch, one way, 16 Amps, 1 module complete all as specifieds and directed .
S&F modular socket 3 pin, 6 Amps, 2 module complete all as specifieds and directed.
S&F modular socket 3 pin, 6 A/16 Amps, 2 module complete all as specifieds and directed .
S&F modular fan regulator,120 Watt, 2 module complete all as specifieds and directed
S&F modular bell push ,6 Amps,240 volts , 1 module complete all as specifieds and directed .
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 volts, AC supply complete all as specified & directed
S&F switch piano, flush type, single pole, one way, 16 Amps, 230 volts, AC supply complete all as specified & directed
S&F bell push, flush type, 6 amps complete all as specified and directed
S&F Bell, ding dong, AC 230V, single pole complete all as specified and directed
S&F socket outlet, 3 pin, 6 Amp,flush type, 230 volts, AC supply complete all as specified & directed
S&F socket outlet, 2-in-1,5 pin, 6 & 16 Amp,flush type, 230 volts, AC supply complete all as specified & directed
S&F stepped type electronic fan regulator, flush type,single phase, AC supply, 230 V complete all as specified and directed
S&F ceiling rose, surface backelite, three terminal, 240 volts complete all as specifieds and directed .
S&F lamp holder,PVC /Polycarbonate type with back plate for batten fittings complete all as specifieds and directed . .
S&F LED light fitting 1 x 20Watt, 220V,decorative box type with driver, holder including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with all fixing arrengenment complete all as specifieds and directed .
S&F energy saving new generation 10W LED bulk head luminaire with opal diffuser, IP 65 and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 Hz complete all as specified and directed.
S&F in replacement of High efficacy 2x1 recess LED flat panel with high brightness LED for glare-free homogenous illumination for POP/normal ceilings (supplied with wedge brackets) complete with all accessories including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 Hz complete all as specified and directed.
S&F LED wall mounted tube light fitting 10W, 3000K complete including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose with all fixing arrengenment complete all as specifieds and directed
Repair/Maintenance of ceiling fan, any type complete for rewinding/BLDC Circuit Plate in situ at site for servicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing blades with detergent powder , greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washers, check nuts, split pin & rubber packing and rubber seal etc including providing and replacing any item found damaged/ unserviceable i,e split pin screw for blades, body & reel capacitor of appropriate capacity, PVC connector, MS galvanised check nut, rubber pads, steel strip clamps, etc to put the fan for smooth and satisfactory working, refixing the fan, motor after executing necessary servicing to their positions, connecting to electric system and testing complete all as specified and directed
All as per Srl item No 58 here-in-before but for exhaust fan of any type.
S&F exhaust fan,steel body,AC, single phase,copper winding with self closing GI louver shutter suitable for operation on 220/230 volts of 380mm sweep,1200 RPM complete all as specified & directed.
S&F ceiling fan complete with remote control,blades,clamp, hooks,down rod and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) with compatible regulator and fixing of hooks by anchor fastner including connecting from ceiling rose/connector with & including flexible copper cable of suitable size complete all as specified and directed .
S&F LED luminaire 600 mm x 600mm, 35/36 watt, 220 V,AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F MCB SPN, 32 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F MCB SPN, 40-63 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F MCB Single pole, 6 to 32 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F MCB four pole, 40 to 100 Amp, 240 Volts with rupturing capacity 10 KA, 'C' series, complete all as specifieds and directed .
S&F LED luminaire round shape, 12 watt, 220 V,AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED luminaire round shape, 15 watt, 220 V,AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
M&L for replacement of RCBO, double pole with sensitivity 100 mA of cap 63 Amp complete all as specified and directed.
S&F factory made epoxy polyester powder coated distribution board TP&N ,4 ways (VTPN DB), double door,(concealed flush to wall) (IP-43 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 250 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with space for provision for 4 pole MCCB as incommer and outgoing MCBs as required at site and conforming to IS: 8623 along with cable end box including making good disturbed surface complete all as specified and directed. NOTE: (a) MCCBs and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/ sleeves and its cost shall be deemed to be included under respective item of BoQ.
S&F MCCB four pole, 100 Amp, 16 KA, 415 volts with adjustable thermal settings complete all as specified and directed
S&F Sheet metal enclosure for DBs,SPN, double door,IP-43 protected, 415 Volts,12 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F Sheet metal enclosure for DBs,SPN, double door,IP-43 protected, 240 Volts,8 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F Sheet metal enclosure for DBs,SPN, double door,IP-43 protected, 240 Volts,4 ways with 200 amps rated copper bus bar complete all as specified and directed
S&F Sheet metal enclosure for DBs,SPN, single door,IP-43 protected, 240 Volts,2 ways complete all as specified and directed
S&F sheet metal enclosure with socket plug top and MCBs 20 Amp, 240 V, AC Supply, Single Pole enclosure with a two pin and earth plug with socket complete all as specified and directed
S&F in replacement submain wiring with two runs of single core PVC FRLS unsheathed, insulated, copper cable of 10 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 10 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 10 Sqmm copper cable and one run of 10 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement submain wiring with two runs of single core PVC FRLS unsheathed, insulated, copper cable of 6 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 6 Sqmm for continous earth wire drawn into and including concealed PVC rigid conduit of suitable size including cutting chases in wall and making good all disturbed surfaces matching with existing surfaces complete all as specified and directed. Note :-Two runs of 6 Sqmm copper cable and one run of 6 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F in replacement submain wiring with two runs of single core PVC FRLS unsheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated,unsheathed FRLSH copper wire 4 Sqmm for continous earth wire drawn into existing conduit of suitable size complete all as specified and directed. Note :-Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuty conductor shall be measured as one length)
S&F in replacement 1100 volt grade, heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 10 Sqmm complete all as specified and directed.
S&F in replacement 1100 volt grade, heavy duty cable PVC insulated multistranded aluminum conductor served with PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 16 Sqmm complete all as specified and directed.
S&F power unit with 20 Amp MCB single pole & plug complete all as specified and directed.
S&F exhaust fan, made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V,50 Hz,RPM 1200,copper winding of sweep 300mm complete all as specified and directed .
S&F Louvers/Shutters of steel body exhaust fan of size 380/450 mm, round or square in shape complete all as specified and directed
S&F electronic meter with temper proof cover & digital display , single phase, 10-60 Amp, IP-54 protection,conforming to IS 13779 class-1, 50 Hz 230 V including necessary electric connection in existing circuit complete all as specified and directed.
Hi Tech Engineers (BID ID -3333323)
SUPER BUILDER (BID ID -3331883)
Durga Electricals (BID ID -3332336)
BMMJ TRADERS AND ENGINEERS (BID ID -3333045)
LAL CONSTRUCTIONS (BID ID -3334057)
M/s K K CONSTRUCTION (BID ID -3341324)
M/S PYRAMID CONSTRUCTIONS (BID ID -3342110)
M/S RAJ ENGINEERS (BID ID -3335860)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .