| 1 | Admitted-Finance 18 MAIN MARKET SECTOR 13 KARNAL 132001 | KARNAL | KARNAL | HARYANA | 132001 | Admitted-Finance |
| 2 | Admitted-Finance 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 3 | Admitted-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | Admitted-Finance |
Tender Value
₹21.4 L
EMD Value
₹42,780
Closing Date
26 Dec 2019, 5:00 pmClosed
Raja Nagender Singh
Executive Engineer, Elect. Division PWD B and R Br., Karnal.
Construction of PWD Rest House at Panipat (Providing EPABX, LAN and Fire Alarm System).
2019_HRY_109691_2
PWD/Elect-KNL/Elect-KNL/16667
Open Tender
Construction Works
Works
60 days
Karnal
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Elect. Division PWD B and R Br
₹42,780
14 Feb 2020
13 Dec 2019
27 Dec 2019
13 Dec 2019
26 Dec 2019
13 Dec 2019
Amount
EPABX SYSTEM Supply Installation Testing Commissioning of IP-PBX with Cold Standby Configuration, User expandable to 300 Lines with Following Configuration: - 32 Analog Users 04 digital users ISDN PRI - 01 08 Analog Trunks 01 Operator Console with 22 Programmable Key a) Remote Maintenance Facility b) Web Based Managment Software c) Call Accounting Software-01 d) DISA & DOSA Facility e) Rack Mountable System f) Call Control Server / Applicatation should be equipped with Intel Based Processer including cost of all material and Labour required to complete the job in all respect upto the entire satisfacation of Engineer in Charge of the work Make : Avaya IP Office Enterprise/ Alcatel Lucent Omni PCX/ Unify Simens Hipath 4000
Supply Installation Testing Commissioning of Digital Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work Make Alcatel Lucent/
Supply Installation Testing Commissioning of Analog Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work Make Alcatel Lucent/ Beetal M71
Supply Installation Testing Commissioning of 12U Wall Mounted 19" Networking Enclosure as per specification and complete with all accessories. (upto size - 600mmW x 600mmD) Make Dlink/Comrack/Ritall
Supplying and Laying of 0.5 mm dia 2 pair telephone cable where ever required in prelaid cable tray, RCC hume pipes, DWC pipes or clamped in open manner as applicable, with suitable aesthetic dressing. Make Delton/Finolex
Supply and Installation of Single Telephone I/O Make Dlink/AMP
Supplying and Laying of 0.5 mm dia Annealed copper jelly filled 10 pair telephone cable where ever required in prelaid cable tray, RCC hume pipes, DWC pipes or clamped in open manner as applicable, with suitable aesthetic dressing. Make Delton/Finolex
Supplying and Laying of 0.5 mm dia Annealed copper jelly filled 20 pair telephone cable where ever required in prelaid cable tray, RCC hume pipes, DWC pipes or clamped in open manner as applicable, with suitable aesthetic dressing.Make Delton/Finolex
SITC, Termination & fixing of 10 pair MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection.Make Krone
SITC, Termination & fixing of 20 pair MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection. Make Krone
SITC, Termination & fixing of 50 pair MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection. Make Krone
PVC Conduits Supply & laying of 25 mm dia. Open/conceal manner medium gauge rigid PVC pipe with GI pulling wire.
LAN SYSTEM S/E/T/C of Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 31.80 Make: AMP / Schneider / D-link.
S/E/T/C of PVC Industrial Channel 45mm*45mm Size complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work AMP/SGI/ Digilink make. Should be of ISO Certified & CE company.
S/E/T/C of UTP Cat-6 information outlet complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
S/E/T/C of Face plate (Single / Dual) complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
S/E/T/C of UTP Cat - Mounting Patch Cords complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link. 3 ft length
5 ft length
Supply of Layer 3 Switch Should have minimum 280 GBPS of higher switching capacity ,Switch should be equipped with minimum 1GHz CPU ,1 GB RAM , 256MB flash , Should be equipped with dual hotswaping PSU Units , Should Support SDN open flow v1.3 , 0degree to 45 degree C operating temp. and 10% to 95% relative humidity , requ9ired port densities :- switch should have minimum 24x 1gb base x with 11x1gb Base T modules and 4x1gb /10G SFP + . scalable upto support at least 2x40G in future. Should support active requdancy vitual; chassis / stackwise/layer 2 / layer 3 protocls/ Layer 2 feature :- 802.1Q VLAN on all ports with support of 4000 concurrents V lans , 802.1AK for dynamic Vlan propagation Support of Minimum 64K MAC Address , Support of MSTP , PVST + , RSTP, Should support private Vlan , Q in Q and 802.1V , Layer 3 Feature : - Support of 16K OSPF IPVP4 8K OSPF IPV6 L3 enteris in Routing Tables, : Support of static from Day1 and upgradable to RIPV2 BGP for IPV4 , IPV6 in future in same hardware. Quality of Servies ( QOS) features :- Should support Diffserv - RFC 2474, RFC 2475, RFC 2597 and RFC 2698 Switch Should support eight harware queues per port , Security features : - Switch should be scalable to support DHCT , Snooping IP soures guard and dynamic ARP inspections ( DAI) Should support Authentications , Authorizations , Accouning (AAA) , UDLD , private VLAN , TACS + Compand Authorizations , TRI-authentications : MAC based , web based and IEEE 802.1x , Should support SSH, SCP-2 and SFTP, Managment Features:- Shuold support CLI , OOB ethernet managment port and USB or External compact Flash , Should Support SNMPv6 , Telenet IPv6 and SSHv6 , DHCPv6 client and relay , DNSv6 client and relay , IPV4 and IPv6 dual stack. Make Cisco WS-3850 24 s /Juniper EX4300-32F, Allied Telesis AT-x930 28GSTX/ Extreme 440G2-24T-10GE4
Supply of Layer 2 Switch Access Switch : Port Type/ density/ Architecture All port on the switch should be of non blocking archtecture Swtich ports of 24 x 10/100/1000 Base T with additional 2x 10 G SFP + slots for Uplink Switch should be equipped with power supply switch fabric 92 GBPS and 68.8MBPS Should have minimum 256 MB D ram and 64MB Flash Resiliency Suport 802.1D spanning Tree and PVST+ , 802.1w,802.1s, Should have BPDU guard or Equivalent feature, Should Support LACP and LAG Should Support Uni directional Link Detenction (UDLD) Should support stacking of MIn 4 Switches Switching /Security /Qos Support private Vlan , Vlan tagging , 802.1V , RIP Minumum DHCP snooping IP Sources guard and Dynamic ARP inspection (DA) , Dynamic Vlan assignment , TI authentication : MAC based , We based and IEEE 802.1x Should support 16K MAC address Minimum 8 Hardware queues per port committed information rate (CRI) function provide bandwidth in increments as low as 64 Kbps Should Support policy based traffic redirection and IP route Should 802.1x with dynamic Vlans Should Vlan Should also have guest Vlan and web based captive portal. should support port Mirroring . should Support device management over IPv6 network network with SNMPv6,TELNETv6 SSHv6 Should support DeSHCP Snnoping ,DHCP relaycket ,dynamiv ARP detection Should support DOS Protect ,Loop Detection and Prevention ,storm Control for multicase ,unicast and broadcast Should Support Flexicle traffic analysis with Netflow or sFlow Should Support minimum 1GMP query solicitation ,IGMP snooping (IGMPv1,v2 and v3) ,IGMP Snooping fast -leave ,MLD snooping(MLDDv1 and v2) Management Features: Support CLI,GUI SNMPV6 ,TELNET v6,SSHv6,NTPv6 Logo ready from day-1 SNMP V1 V2C and V3 and TPTP , LNDP server operating Conditions Operating Temp ) degree to +45 degree C operating humadity non condensing 10% to 90% Make Cisco WSC 2960X-24TD/ Junipper EX3300-24T/ Allied Telesis GS924MX/ Extreme 210-240-GE2
S/E/T/C 12 U rack including power distribution kit, cable Manager complete in all respect HCL / Comrack/ PRESIDENT make with 2 fan.
S/E/T/C 22 U rack including power distribution kit, cable Manager complete in all respect HCL / Comrack/ PRESIDENT make with 2 fan.
S/E/T/C of 24 port Cat-6 jack patch panel complete as per specification up to the entire satisfaction of Engineer-in-Charge of the work AMP/HCL/ Panduit make.
S/E/T/C of Cable manager complete as per specification up to the entire satisfaction of Engineer-in-Charge of the work AMP/Panduit Schneider make.
S/E/T/C of single phase 240 volt AC 2 KVA online UPS with Exide/ Panasonic make batteries back for 1 hour APC / Elent/ Pride/ Microtek make.
FIRE ALARM SYSTEM SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Bosch FPA 1000 / Cerberus by siements/ Edwards EST3/Honeywell Morley Zxe series
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Makes :(Makes: BOSCH FMR-1000-RCMD, Cerberus by Siemens ,Morley ZXRA , Edwards 3-LCD ANN)
SITC of addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440, Siemens Cerberus OH921+DB-11, Honeywell Morley HM-PTSE+B501, Edwards SIGA PHD+SIGA
SITC of addressable Heat Detector wht fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. (Make: Bosch FAH-440+FAA-440, Siemensr Cerberus HI921+DB-11, Honeywell Morley MI-RHSE+B501, Edwards SIGA DHI+SIGA
SITC of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring (Make: Bosch / Siemens Cerberus/ Morley / Edwards
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work. Make Siemens cerberus/ Morely/ Edwards
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the ob in all respect upto the entire satisfaction of Engineer - in - charge of work. Make: Bosch/ Siemens Cerberus/ Morley/ Edward.
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Make GLOLITE / PEARL / OMEX
SITC of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes :Bosch /Siemens Cerberus / Morley / Edwards
SITC of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Color LED status indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switch from 01-99 dully approved to GEA GEW1-082 conforming to BS5839 Standards and Duly approved by EN54/LPCB/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. (Makes: Bosch- FLM - 325 - 214, Siemens cerberus HTRI-M,Morley MI-DMMI, Edwards EST3
SITC of minimum 1000 Mtr. Range Kheraj / National make SIRON generator provided at the roof of the building with separate Power SITC, relay.
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex / Minimax / Cease Fire). ABC dry Powder extinguisher 6 Kg Cap
Water CO2 9Ltr Cap
CO2 type 4.5kg cap
(HSR 31.40) Supply and erection of 1.5sqmm PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Havells /Polycab/Finolex
HSR (31.44) SITC of PVC conduit pipe 25mm dia ISI marked (medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer -in-charge of the work. Make: BEC, AKG, Kalinga / Diplast
SITC of 2KVA online UPS with external SMF batteries 12V fo suitable AH battery for minimum 2 hour backup Make Microtek / Lumnious / APC Libert.
Electrocare Systems and Services
Hytek Turnkey Projects Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .