Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2 3 AMIT VIJAY APARTMENT KASTURBA CROSS ROAD KANDIVALI W MUMBAI 67 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | Admitted-Finance |
| 2 | Admitted-Finance 33 RUSHIKESH INGOLE NAGAR MODERN CO OPERATIVE HOUSING SOCIETY WARDHA ROAD NAGPUR MS 440 005 | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | Admitted-Finance |
| 3 | Admitted-Finance 203 ELECON CHAMBER ANDHERI KURLA ROAD VILLAGE TOWN NEAR SAKINAKA TELEPHONE EXCHA CITY ANDHERI EAST MUMBAI MAHARASHTRA 400072 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | Admitted-Finance |
| 4 | Admitted-Finance B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Finance |
| 5 | Admitted-Finance 206 MADHUKALA BHAVAN R K VAIDYA ROAD DADAR MUMBAI MAHARASHTRA 400028 | MUMBAI | MAHARASHTRA | 400028 | Admitted-Finance |
Tender Value
₹8.4 L
EMD Value
₹19,896
Closing Date
30 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer
HLUD Office, RLG, BARC
Non Destructive examination of AFD Building at South Site, BARC, Trombay, Mumbai.
2025_BARC_843142_1
Non-Destructive examination of AFD Building at South Site, BARC, Trombay, Mumbai.
Open Tender
Civil Works
Works
365 days
AFD, South Site, BARC, Trombay
Refer Tender Documents
3 documents required · 3 mandatory
₹0
₹19,896
8 Apr 2025
7 Jan 2025
5 Feb 2025
7 Jan 2025
30 Jan 2025
7 Jan 2025
7 Jan 2025 - 14 Jan 2025
Amount
Conducting ultra sonic pulse velocities tests, at all locations prepared after chipping the plaster, on columns, beams and portal frames to assess the integrity of concrete as per BIS/ASTM specifications etc. complete.
Conducting rebound hammer test as per BIS/ASTM standards etc. complete.
Conducting half-cell potential meter test at all locations to assess the risk of corrosion including exposing the reinforcement for carrying out the test. The test shall be conducted as per BIS/ASTM specifications. The quoted rate shall include charges for filling back areas chipped for exposing the reinforcement with polymer modified mortar. 5 potential observations taken at one location will form a unit for measurement purposes.
Extraction and testing of concrete drill dust samples from the structure. Three drill dust samples from depths 0-15mm, 15-30mm and 30-45mm shall be collected from each location. The samples shall be tested for chlorides, sulphates, PH and alkalinity.
Conducting carbonation depth test study on the structure
Extraction of concrete (75mm dia) cores from locations specified and testing for crushing strength, water absorption & unit weight. The quoted rate shall include charges for filling back the core holes with polymer modified mortar and finishing etc. complete
Conducting profometer scan at specified location of the structure for reinforcement steel location, size and cover measurement, etc. complete.
Conducting conduct an aggregate alkali reaction test on hardened concrete, you typically follow guidelines set by standards ASTM C1260 (Standard Test Method for Potential Alkali Reactivity of Aggregates) of hardened concrete at different loactions of building . The test is to conducted based on ASTM C856-77, to find out the different properties of hardened concrete such as Aggregate Characteristics, Cement Type, Microstructure, Cracking and Defects, Hydration Products, Porosity and Permeability, Color and Texture, Historical Context to estimae the Durability and Performance of concrete. The quoted rate shall include charges for filling back areas chipped for exposing the reinforcement with polymer modified mortar and submission of test reports.
Conducting Linear Polarisation resistence test at all locations to assess the risk of corrosion including exposing the reinforcement for carrying out the test. The test shall be conducted as per BIS/ASTM specifications. The quoted rate shall include charges for filling back areas chipped for exposing the reinforcement with polymer modified mortar and submission of test reports. 5 potential observations taken at one location will form a unit for measurement purposes.
Preparation and submission of two copies of draft report as specified followed by five copies of final report along with a soft copy of the same on diskette covering Non Destructive test observations, analysis, interpretation and conclusions of NDT observations, drawing out measures for durability make up, estimation of repair quantities, rate, rate analysis for major repair items. Note: 1. The rates quoted for item No.1 to 10 shall include preparation of test area, making good the areas with polymer modified mortar, disposing off debris and necessary scaffolding arrangements for testing
Conduct distress mapping Analysis for each floor in AFD building including highbay, Store rooms, sitting rooms , canopy staircase, porch all the areas of AFD. Distress symptoms will be marked on floor plan as per notation used or as directed by Project Engineer and prepare data sheets mentioning exact location of each crack, height, and width of crack and Preparation and submission of two copies of draft report as specified followed by five copies of final report along with a soft copy of the same on diskette covering distress mapping Analysis observations and conclusions along with photos etc., Complete as directed by Engineer-in-Charge. Note: Condition Survey of the area under consideration shall be carried out, which includes a) Visual Inspection: Grouping of structural members should be done during visual inspection based on environmental exposure conditions e.g. external and internal members. Also, identification of Corrosion prone locations as per Visual Inspection. Follow the notations and typical worksheet for recording distress during visual inspection and damage classes based on visual inspection as per CPWD handbook on repair. The condition survey report shall comprise the output of visual inspection and NDT results. Major sections to be covered in the report shall be: (i) Identification of the cause of the distress. (ii) Systematic documentation of all observations during visual inspection, including distress maps. (iii) Systematic documentation of all test results obtained from NDTs. (iv) Determination of concrete properties based on NDTs (v) Requirement of propping of structural members to relieve part/full load acting on the member. (vi) Requirement of immediate evacuation and safety measures to prevent any immediate major mishap. (vii) Recommendations on repair/retrofit strategy with due consideration to available space and accessibility for ongoing activities. (viii) Requirements on safety measures to be adopted during execution of repair/retrofit jobs. (ix) Limitations/assumptions used. (x) Any other recommendation.
BECQUEREL INDUSTRIES PVT. LTD. (BID ID -3164503)
B.J.MEHTA ARCHITECTURAL & STRUCTURAL CONSULTANTS PVT. LTD. (BID ID -3163169)
KBP Civil Engineering Servises (BID ID -3164568)
Cortex Construction Solutions Pvt Ltd (BID ID -3163134)
Geo Designs and Research Pvt Ltd (BID ID -3163205)
Epicons Consultants Pvt Ltd (BID ID -3163391)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .