Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-Finance PLOT NO 102 H NO 21 1382 102 GROUND FLOOOR SAMATHA NAGAR COLONY OLD SAFILGUDA ROAD NO 3 HYDERABAD RANGAREDDI TELANGANA 500056 | HYDERABAD | TELANGANA | 500056 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹42.4 L+₹5.2 L (14.1%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.0 L+₹11.9 L (32.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.7 L+₹12.6 L (34.0%)Rejected-Finance 12 2 332 21 HILL COLONY OPP SUNRISE SCHOOL MEHDIPATNAM HYDERABAD 500028 | HYDERABAD | HYDERABAD | TELANGANA | 500028 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.9 L+₹12.8 L (34.4%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
4 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
PROVISION OF STORAGE ACCOMDATION AND ADDITIONAL /ALTERATION IN P-1 AND CERTAIN MINOR AND REVENU WORKS UNDER GE(I) RND KBAGH HYDERABAD
2025_MES_708269_1
8892
Open Tender
Civil Works
Item Rate
270 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹90,000
Yes
20 Jun 2025
15 May 2025
6 Jun 2025
15 May 2025
4 Jun 2025
29 May 2025
Amount
Demolition unreinforced cement concrete of any description and in any position not otherwise specifically provided for
Demolition of brick work or stone masonary built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as spd & directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in Hard/Dense soil
M/L Plain Cement concrete Type D2 (1:4:8) (40 mm graded stone aggregate) as in foundations, filling and mass-concrete
M&L for brick work with sub class B Brick straight or curved on plan to any redius in half brick thick walls built in CM 1:4 Complete
M&L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping etc including necessary formwork and finishing exposed surfaces fair and even complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc. 25 cm as in soil.
Removal of excavated material not exceeding 50m and deposited where directed at level not exceeding 1.50 Mtr above the starting point, soil
Taking down cement plaster/cement lime plasters of bk work on any description including racking out of joints and cleaning dust etc
M/L for rendering 15mm thick in CM 1:6 on other than fair faces of brick/conc surfaces face of wall, finished even & fair
M/L for rendering 15mm thick in CM 1:4 on other than fair faces of brick/conc surfaces face of wall, finished even & fair
M/L for rendering 10mm thick in CM 1:3 on other than fair faces of brick/conc surfaces face of ceiling, finished even & fair
M&L for preparation of newly plastered surfaces of walls prepararion of surfaces and applying two coats of oil bond distemper incl Birla putty over one coat of primer etc all as specified and directed by Engr-in-Charge
M&L for Preparing old plastered surfaces and applying two coats of distemper oil emulsion including on one coat walls over a coat of wall putty to make surfaces smooth.
M&L for preparation of newly plastered surfaces of ceilingl by prepararion of surfaces and applying two coats of white wash all as specified and directed by Engr-in-Charge
M&L for preparation of old ceiling surface by complete removal & prepararion of surface and applying two coat white wash all as specified and directed by Engr-in-Charge
M&L for Preparing old plastered surfaces and applying two coats of cement base paint one coat of alkali resistan paint walls over a coat of wall putty to make surfaces smooth.
M&L for Preparing new plastered surfaces and applying two coats of cement base paint one coat of alkali resistan paint walls over a coat of wall putty to make surfaces smooth.
Taking down chowkhat with shutters (without taking off shutters from the frame) exc 1.50 sqm each but n. exc 4 sqm each.
Taking down chowkhat with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each .
M & L 105x60mm x1.2mm thick Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed
Supply & fixing of UPVC windows three track sliding window with two glazed and one wire mesh sliding shutters of profile width of frame 50 mm to 60 mm, limit thermal conductivity to l.3 Kcal/sqm/hr centigrade, sound insulation up to 4-0 bds, Density, 1.46 gm/ml, Tenstile strength - 43.9N/sqmm, % Elongation at break - 215, Tenstile mpduls - 2840N/Sqmm, Flexural strength - 51N/sqmm, Heat aging at 150 degrees - No surface defect, Thickness - 2 mm, Flexural moduls elasticity 2200N / sqmm, double baskets & wool pile on window, multi point gear locking at different sides of frame, anti lift device on slide windows with temper proof screws with and including glazed shutter fixed with 5 mm thick plain sheet glass & wire mesh shutter with stain less steel wire cloth 304 grade stainless steel with 0.254 mm (30 gauge) dia of steel wire and 0.95 mm width of aperature and filling gap of wall and frame with silicon sealent complete incl taking down old down old window complete all as specified. all as directed .Area Not Exc 2.00 Sqm.
S & F 5.5mm Sheet glass area exc 0.5 sq. m in each pane
M&L Vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor & veertical surface complete all as specified and directed complete all as specified and directed
M & L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F 40mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides
M & L for proividing two coaat of synthetic enamel paint over one coat of red oxide primer Surfaces of any description, over 10cm in width or girth,not otherwise described
Laying 100mm sand , spread, rolled and consolidated to gradient and camber required
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
S & F 150 mm aluminium anodised barrel tower bolt of extruded section.
S&F mild steel butt hinges, medium weight, size 100mm with ISI mark.
S&F annodised aluminium handle, fabricated type of size 150mm.
M & L Surfaces of any description, not otherwise descri-bed, over 10cm width or girth 17002 Ditto,
S & F for gypsum board 12mm thick in ceiling at different levels (Sunk & Raised) type of approved design fixed with screws as manufactures instructions including demolition of existing false ceiling complete all as specified and directed.
S & F Gl frame work for seamlessceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Hardcore of broken bricks gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
Hardcore of broken bricks gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L for plain cement concrete(1:3:6) type C-2 (using 40 mm graded stone aggregate) of 100 mm thick as in Path / PCC floor, finished even and fair including demolition of existing concrete complete all as directed.
S&F Steel rolling shutters 1.25 mm lath thickness, Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete but motorised type rolling shutter of size exceeding 32 sqm but not exceeding 40 Sqm including taking down of existing shutter along with connected to gear box, shaft etc, complete all as directed.
Supply only electric motor of 2.00 HP capacity suitble for rolling shutter of size exceeding 30 sqm but not exceeding 40 Sqm, single phase power, automatic stop level, thermostat for cooling motor and chain crank of 3 - 6mtr length in the absence of power all built in one single unit and shaft pipe of 150mm bore dia, including taking down of existing shutter along with conventional motor and connected to gear box, shaft etc and refixing shutter in same position, complete all as directed.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of serviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
Material and labour for point wiring complete with 1.5 Sqmm single core PVC insulated FRLS unsheathed cable voltage up to and including 1100 volts grade multi-stranded copper conductor drawn through and including rigid PVC conduit medium grade 20mm or higher dia ISI marked as required at site including conduit accessories such as junction boxes, inspection covers etc, surface/concealed on brick masonry walls, roofs, floors etc by means of saddles and clips etc including cutting chasing and making good of disturbed surfaces to match existing surface where required and concealed galvanised box factory made of suitable size including modular plate as per number of switch modules required for fixing switches, sockets fan regulators etc of required size including provision of PVC insulated 1.5 Sqmm FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly all as specified and directed for the following:- One light/ fan point/exhaust point controlled by one, one way switch/bell push
All as per item No. 1 above but for 5 Amps socket on independent board
All as per item No. 1 above but for 5 Amps socket on same board
All as per item No. 2 above but wiring with 4.0 Sqmm for 15 Amps switch socket combination on independent board including providing 4.0 Sqmm PVC insulated FRLS unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly.
Supply and Fixing Modular switch single pole, one way 6 Amps one module all as specified and directed.
Supply and Fixing Modular switch single pole, one way 16 Amps one module all as specified and directed.
Supply and Fixing Modular switch single pole, one way 16 Amps two moduler 230V multipurpose all as specified and directed.
Supply and Fixing Modular socket 6 Amps multipurpose 2 in 1- 2/3 pin 2 module complete all as specified and directed.
Supply and Fixing Modular socket 6/16 Amps multipurpose 2 in 1 -2/3 5 pin 2 moduler complete all as specified and directed.
Supply and Fixing ceiling rose three terminals Poly carbonated isolated body complete all as specified and directed.
Supply and fix Industrial type LED luminaire 1x20W, aluminium housing with polycarbonate diffuser, with , 10% THD, lumen efficiency not less that 120 lm/watt complete with all accessories prewired and including connecting up with three core twister flexible copper conductor cable with suitable size complete removing unserviceable fittings all as specified and directed.
Supply and Fix MCB Distribution board, SPN 12 way sheet metal enclosure double door 415 volts, AC, factory made, fixed on wall suitable for mounting Isolators and MCBs with bus bars, neutral link and earth bar of following No. of ways including taking down unserviceable distribution board and making good to the disturbed surfaces of wall all as directed.
Supplying and fixing 63 Amp rating, double pole, 240 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and Fixing MCB SP 6 to 32 Amps, 240 Volts 10 KA 'C' series complete all as specified and directed.
Supply & Fix sub main wiring with 2 run of 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 Volts grade multistranded with copper conductor (FRLS) drawn through and including non metallic rigid PVC conduit 25 mm dia including conduit accessories surface/concealed type on walls, roof, floors etc including one run of 4 Sqmm PVC copper conductor as earth continuity wire all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
GI earth wire of 6 mm dia fixed on walls/floor as earth continuity conductor connected to DBs/ panels etc.
Supply & fix ceiling fans complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissionin etc. as required.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 2 TR, BEE 5 star ratedcomplete all as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
M&L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multi standard FRLS copper conductor 1100 V grade drawn through in PVC casing & caping on walls/Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S/F modular socket out let 6A/16A - 2/3 pin combined 2 module, multipurpose type complete all as directed by Engineer-in-Charge.
Supply & fix MCB DB 4 way, 415V, 50Hz, AC, sheet metal enclosure, double door, IP 43 protection suitable for MCB TPN/4 pole capacity 100 Amps as incomer and SP/DP/TP/TPN MCB's as outgoings comprising of 200 Amps busbar rating, neutral bar, duly powder coated painting and fixed flush in wall and making good the disturbed surfaces to match with existing surface and making electrical connections using suitable sizes of copper thimbles/ lugs including taking down old unserviceable item complete .
M&L for sub main wiring complete with 2 runs of 6.0 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends to meters and DB's including provision of 1 run of 4 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly complete all as directed by Eng-in-charge
S&F MCB SPN 40 Amps complete all as directed by Engr-in-charge
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc.
Supply and Install 4 ch. 1080P lite cosmic HD DVR / support upto 2.4MP IP Camera Auto adaptive HDCVI/AHD/TVI/CVBS signals / all channel 1080P lite real time recording H.264 dual-stream video compression / HDMI / VGA simultaneous video output Support 1 SATA HDD up to 6TB, 2 USB2.0 / mobile software: iCMOB, GCMOB CMS software:KVMS, KVMS pro
M&L of 5MP IR Bullet camera with 1/2.9‑inch CMOS, Total sensor pixels 3072 (H) x 1728 (V); Sensitivity – Measured according to IEC 62676 Part 5 (1/30, F1.6), Color 0.379 lx, Mono 0.042 lx, With IR 0.0 lx, 128dB WDR, H.265; H.264; M- JPEG, Automatic Electronic Shutter (AES); Intelligent Dynamic Noise Reduction, Intelligent Defog, Essential Video Analytics, Privacy Masking, Pixel counter, Memory card slot, IR Range 30mtr, Automatic Varifocal 3.2 to 10 mm, Alarm Input 1/1, Audio Input/output, RJ45, G.711, Signal-to-Noise Ratio >50 dB, Audio Streaming Full-duplex / half duplex, ONVIF Profile S, G & T, IP66, IK10, PoE, CE, FCC, UL certified, as directed by Engineer-in-charge. Make: BOSCH / MOBOTIX / AVIGILON, Model NBE-3503-AL /Tecnocommercial equivalent in Honeywell
Supply and Install HDD 1 TB Store more, compute faster, and do it confidently with the proven reliability of BarraCuda internal hard drives build a powerhouse gaming computer or desktop setup with a variety of capacities and form factors
Supply and Install 4 Channel SMPS for CCTV, Power Supply Adapter for up to 4 CCTV Security Cameras CCTV Power Supply SMPS, Power Supply Adapter for Video Surveillance Camera System, CCTV, Dome, Bullet Cameras complete
Supply and Install 23AWG Pure Copper 3+1 CCTV Camera Coaxial Cable For High-Speed Audio Video Signal BNC Video & Power Cord With Positive Negative Mic Earth Wire for all Security Camera DVR complete
Supply and fix BNC and DC Connector cable 6 cm x 4 cm x 3 cm will help to run your pre-made CCTV simply. Just plug both ends to your security cameras, DVR, and power supply. It will make the task of installing security cameras complete
Supply and fix PVC Junction Box for CCTV Cameras Durable, Dust-proof, Waterproof, Weatherproof, Dimension: 4 X 4 Inch Designed for Outdoor & Indoor Use, Weatherproof and Waterproof. Well Protected from Rain and Water Splash Back, Making Them Perfect for Joining Wires Inside Easy to Install and Easy to Use complete
M&L UPS 1 KVA with 1 hour backup complete all as directed by Engineer-in-charge. Make: Delta / Microtek / APS
S&F Display TV of Screen size 19" HD LED including mounting accessories complete all as directed by Engineer-in-charge.Make:Samsung/LG/Panasonic
Supply and fixing of Camera Stand all as specified and directed
M&L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multi standard copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed on walls/ in existing Conduit on Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 2.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly and taking down old one complete all as specified and directed for 3One 3 pin socket outlet. 15 amps,independent:- Make:- Conductor: Finolex/Finecab/Polycab/Plaza PVC Conduit: Sudhar/Diamond/Avon
Indu Electricals (BID ID -3312745)
M/S PAVANI ENTERPRISES (BID ID -3311473)
rahi consultant (BID ID -3312610)
SRI SAI ENTERPRISES (BID ID -3311739)
SUN LIGHT HOUSE (BID ID -3311797)
M/s K Venkateswara Rao (BID ID -3311908)
PAVAN ENTERPRISES (BID ID -3311704)
UNITY ENGINEERING TRADERS (BID ID -3311747)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .