Loading…
Loading…
Tender Value
Refer Docs
Closing Date
9 Nov 2026, 11:00 am
S R Mishra
Power Grid Corporation of India Limited, Saudamini, 3rd Floor, Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001.
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
CC/NT/W-GIS/DOM/A02/26/13152
Open
Power/Energy Projects/Products
Works
India
₹25,000
25 Sept 2026
25 Sept 2026
9 Nov 2026
25 Sept 2026
9 Nov 2026
25 Sept 2026
6 Oct 2026
Old Signal list
1. Distance relay - Missing internal signals related to functions such as AR, Weak-infeed, SOTF. 2. Addition of Differential Protection signals 3. Addition of Transformer phase wise Mechanical tripping signals 4. Addition of Centralized Busbar protection related signals. 5. Addition of tertiary transformer related protection signals. 6. Addition of Backup impedance protection signals for ICT & Reactor. 7. Addition of Directional OC & EF protection signals for ICT. 8. Addition of Mechanical trippings & alarms associated with REF. 9. Addition of NGR associated protection & CB Alarms 10. Addition of De-centralised - Busbar protection signals 11. Addition of Breaker failure protection initiation & Re-trip signals in standalone & centralized busbar protection 12. Addition of BCU – AR associated internal signals, TC phase wise, CSD related alarms, Bay wise measurements
IED MODEL
Time Synch
Goose
BB4_P741_87CUA
Auto generated
Port used (on gateway)
400KV SERVER M
BB4_P741_87CUA
IED name
Customer Ref
Panel Number
System;GosGGIO2
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
BB4_P741_87CUB
Auto generated
Port used (on gateway)
400KV SERVER M
BB4_P741_87CUB
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CznPDIF1
Protection;BbpT01PDIF1
Protection;BbpT02PDIF1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;AlmGGIO1
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;DisPDIS5
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPSCH1
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
System;GosGGIO1
IED name
Customer Ref
Panel Number
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Records;PriRFLO1
Records;PriRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;AlmGGIO1
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;DisPDIS5
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPSCH1
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
System;GosGGIO1
IED name
Customer Ref
Panel Number
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Records;PriRFLO1
Records;PriRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;AlmGGIO1
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;DisPDIS5
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPSCH1
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
System;GosGGIO1
IED name
Customer Ref
Panel Number
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Records;PriRFLO1
Records;PriRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DifPDIF1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
System;GosGGIO1
IED name
Customer Ref
Panel Number
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS4
SPARE
Protection;DifPDIF1
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Records;RFLO1
Records;RFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R401_P743_PU_A
Auto generated
Port used (on gateway)
400KV SERVER M
R401_P743_PU_A
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
SPARE
SPARE
SYSTEM
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R401_P743_PU_B
Auto generated
Port used (on gateway)
400KV SERVER M
R401_P743_PU_B
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF2
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;EfmEl1PTOC1
Protection;EfmEl1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;VhzWg1PVPH1
Protection;VhzWg1PVPH2
SYSTEM
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SYSTEM
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SYSTEM
IED name
Customer Ref
Panel Number
SPARE
SPARE
SYSTEM
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SYSTEM
Customer Ref
Panel Number
SYSTEM
Customer Ref
Panel Number
SYSTEM
Customer Ref
Panel Number
SYSTEM
Customer Ref
Panel Number
SYSTEM
Customer Ref
Panel Number
SYSTEM
Customer Ref
Panel Number
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
SYSTEM
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;HzrHvwPTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;VhzWg1PVPH1
Protection;VhzWg1PVPH2
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
Protection;PTRC1
Protection;CbfRBRF1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R407_P743_PU_A
Auto generated
Port used (on gateway)
400KV SERVER M
R407_P743_PU_A
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R407_P743_PU_B
Auto generated
Port used (on gateway)
400KV SERVER M
R407_P743_PU_B
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;SenRefPDIF1
SPARE
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
Protection;PTRC1
Protection;CbfRBRF1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R412_P743_PU_A
Auto generated
Port used (on gateway)
400KV SERVER M
R412_P743_PU_A
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R412_P743_PU_B
Auto generated
Port used (on gateway)
400KV SERVER M
R412_P743_PU_B
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
B401_LINE
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
cos ft : Power factor
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
cos ft : Power factor
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
BPH TAP CHANGE IN COMPLETE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
cos ft : Power factor
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
cos ft : Power factor
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
SIGNAL
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
PROFILE
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Port used (on gateway)
GE Reserved
Auto generated
Read Only
ERROR
Electrical Data
Equipment Link
Mp0HLAOIPrt
Mp0HLAOIPrt
Electrical Data
Equipment Link
Electrical Data
Equipment Link
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Sp0HLARev
Dp0000OpM
Mp0HLAIsag
Dp0000OpM
Mp0HLAOIPrt
Sp0HLARev
Electrical Data
Equipment Link
Sp0HLARev
Mp0HLAIsag
Sp0HLARev
Electrical Data
Equipment Link
Electrical Data
Equipment Link
Sp0HLARev
Sp0HLARev
Mp0HLAIsag
Electrical Data
Equipment Link
Electrical Data
Equipment Link
English
SYSTEM INFORMATION SERVER OI
1 | AgencyStatus
AGENCY STATUS
HEALTHY
FAULTY
Agency status
1 | AutomaticArchiving
AUTOMATIC ARCHIVING STATUS
HEALTHY
FAULTY
Auto archiving
1 | CentralArchiving
HISTORIAN DATABASE STATUS
Central archive
1 | CommDevice
OI SBUS LINK
HEALTHY
FAULTY
Device link
1 | LogQueue
LOGGING QUEUE STATUS
HEALTHY
FAULTY
Log Queue
1 | OperatingMode
OPERATING MODE
Operating mode
1 | RedDevice
REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
1 | RedundancyStatus
REDUNDANCY STATUS
Redundancy status
1 | SyncDevice
SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
1 | CouplingStatus
SBUS ACQUISITION STATUS
HEALTHY
FAULTY
IEC Coupling
1 | Printing
PRINTER STATUS
Printer status
1 | BackupPrinting
BACKUP PRINTER STATUS
BackupPrint stat
SYSTEM INFORMATION CLIENT OI
2 | CommS2K_C
CONNECTION STATUS
HEALTHY
FAULTY
OI client link
SYSTEM INFORMATION MiCOM C264
3 | DBIncoherency
DATABASE INCONSISTENCY
DB incoh. SPS
3 | DBSwitch_SPC
C264 DATABASE SWITCHING
EXECUTE
DB switch ctrl
3 | CommDevice
C264 SBUS LINK
HEALTHY
FAULTY
Device link
3 | DIAcquisitionStopped
DIGITAL INPUT ACQUISITION
FAULTY
HEALTHY
DI acq stopped
3 | LocRemDevice_DPC
C264 BAYS CONTROL MODE CHANGE
REMOTE
LOCAL
Loc/rem ctrl DPC
3 | LocRemDevice
C264 MANAGED BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote DPS
3 | LocRemDeviceForIEC
C264 BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote SPS
3 | MainInternalStatus
C264 FAULT LEVEL FOR REDUNDANCY
Main status MV
3 | ModeDevice_DPC
C264 FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
3 | OperatingMode
C264 OPERATING MODE
Operating mode
3 | RedChangeMode_SPC
C264 BIU REDUNDANCY RELAY CO 2
ACTIVATE
DEACTIVATE
Red mode ctrl
3 | RedChangeStatus_SPC
C264 BIU REDUNDANCY RELAY CO 1
ACTIVATE
DEACTIVATE
Red Status ctrl
3 | RedChangeMode
REDUNDANT C264 CHANGE MODE
ACTIVE
STANDBY
Red. change mode
3 | RedChangeStatus
REDUNDANT C264 STATUS
ACTIVE
STANDBY
Red. change stat
3 | SoftError
SOFTWARE ERROR DETECTED
Soft. error SPS
3 | SyncDevice
C264 SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
3 | TestDevice_DPC
C264 CHANGE EXPLOITATION MODE
NORMAL
Test control DPC
3 | WatchdogError
C264 WATCHDOG RELAY STATUS
HEALTHY
FAULTY
Watchdog SPS
3 | ModeDevice
C264 OPERATING MODE
RUNNING
MAINTENANCE
Device mode
3 | DisturbUCA2
DISTURBANCE FILE ON C264
READY
NOT READY
DREC ready
3 | CounterTop
C264 COUNTERS ACQUISITION TOP
Counter Top
3 | ExtClockStatus
GPS SYNCHRONISATION SOURCE
HEALTHY
FAULTY
Ext clock status
3 | RedDevice
C264 REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
3 | BuffOvGtw1
REPORT BUFFER OVERFLOW GTW 1
Buff Ov Gtw 1
3 | BuffOvGtw2
REPORT BUFFER OVERFLOW GTW 2
Buff Ov Gtw 2
3 | BuffOvOI
REPORT BUFFER OVERFLOW OI
Buff Ov Oi
3 | BuffOvOIBck
REPORT BUFFER OVERFLOW OI BACKUP
Buff Ov Oi Bck
3 | BIUStatus
BIU BOARD STATUS
BIU status
3 | GHUStatus
GHU BOARD STATUS
GHU status
3 | AIUStatus
AIU20x BOARD STATUS
AIU status
3 | AIUStatus
AIU21x BOARD STATUS
AIU status
3 | AOUStatus
AOU200 BOARD STATUS
AOU status
3 | DIUStatus
DIU BOARD STATUS
DIU status
3 | DOUStatus
DOU BOARD STATUS
DOU status
3 | CCUStatus
CCU BOARD STATUS
CCU status
3 | TIUStatus
TMU BOARD STATUS
TMU status
3 | HBUStatus
HBU BOARD STATUS
HBU status
3 | CommIED
IED CONNECTION STATUS TO C264
HEALTHY
FAULTY
IED SPS com.
3 | SyncIED
IED SYNCHRONISATION STATUS
HEALTHY
FAULTY
IED SPS Synchro.
3 | DisturbIED
IED DISTURBANCE FILE
READY
NOT READY
IED DREC ready
3 | ISAGRAFStatus
ISAGRAF STATUS
ISAGRAF status
3 | PrinterStatus
PRINTER STATUS DPS
Printer st. DPS
3 | Printing
LOCAL PRINTER STATUS
Printer Status
3 | RedSCADA
C264 SCADA PORT COMMUNICATION
ACTIVE
STANDBY
Redundancy SPS
3 | CommSCADA
SCADA CONNECTION STATUS TO C264
HEALTHY
FAULTY
SCADA SPS com.
3 | GlobalAIUStatus
ALL AIU STATUS
FAULTY
HEALTHY
All AIU status
3 | GlobalAOUStatus
ALL AOU STATUS
FAULTY
HEALTHY
All AOU status
3 | GlobalCCUStatus
ALL CCU STATUS
FAULTY
HEALTHY
All CCU status
3 | GlobalDIUStatus
ALL DIU STATUS
FAULTY
HEALTHY
All DIU status
3 | GlobalDOUStatus
ALL DOU STATUS
FAULTY
HEALTHY
All DOU status
3 | GlobalTMUStatus
ALL TMU STATUS
FAULTY
HEALTHY
All TMU status
3 | GlobaHBMUStatus
ALL HBU STATUS
FAULTY
HEALTHY
All HBU status
3 | GlobalIEDStatus
ALL IED STATUS
FAULTY
HEALTHY
All IED status
3 | GlobalPrinterStatus
ALL Printer STATUS
FAULTY
HEALTHY
All Printer stat
3 | GlobalRackLinkStatus
ALL RACK STATUS
FAULTY
HEALTHY
All rack status
3 | RackLinkStatus
RACK LINK STATUS
HEALTHY
FAULTY
Rack link status
3 | LocalAlarmAck_SPS
LOCAL ALARM ACKNOWLEDGEMENT
Local alarm ack
3 | SettingDone
SETTING DONE
Setting done
3 | SettingFileDiscordance
SETTING FILE DISCORDANCE
Setting disc.
3 | SettingInProgress
SETTING IN PROGRESS
Setting in prog.
3 | SettingIncoherency
SETTING INCOHERENCY
Setting incoher.
SYSTEM INFORMATION MiCOM C364
4 | DBIncoherency
DATABASE INCONSISTENCY
DB incoh. SPS
4 | DBSwitch_SPC
C364 DATABASE SWITCHING
EXECUTE
DB switch ctrl
4 | CommDevice
C364 SBUS LINK
HEALTHY
FAULTY
Device link
4 | LocRemDevice_DPC
C364 BAYS CONTROL MODE CHANGE
REMOTE
LOCAL
Loc/rem ctrl DPC
4 | LocRemDevice
C364 MANAGED BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote DPS
4 | LocRemDeviceForIEC
C364 BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote SPS
4 | LogQueue
LOGGING QUEUE STATUS
HEALTHY
FAULTY
Log Queue
4 | ModeDevice_DPC
C364 FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
4 | OperatingMode
C364 OPERATING MODE
Operating mode
4 | SoftError
SOFTWARE ERROR DETECTED
Soft. error SPS
4 | SyncDevice
C364 SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
4 | TestDevice_DPC
C364 CHANGE EXPLOITATION MODE
NORMAL
Test control DPC
4 | WatchdogError
C364 WATCHDOG RELAY STATUS
HEALTHY
FAULTY
Watchdog SPS
4 | ModeDevice
C364 OPERATING MODE
RUNNING
MAINTENANCE
Device mode
4 | ExtClockStatus
GPS SYNCHRONISATION SOURCE
HEALTHY
FAULTY
Ext clock status
4 | RedDevice
C364 REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
4 | CommIED
IED CONNECTION STATUS TO C364
HEALTHY
FAULTY
IED SPS com.
4 | SyncIED
IED SYNCHRONISATION STATUS
HEALTHY
FAULTY
IED SPS Synchro.
4 | DisturbIED
IED DISTURBANCE FILE
READY
NOT READY
IED DREC ready
4 | ISAGRAFStatus
ISAGRAF STATUS
ISAGRAF status
4 | RedSCADA
C364 SCADA PORT COMMUNICATION
ACTIVE
STANDBY
Redundancy SPS
4 | CommSCADA
SCADA CONNECTION STATUS TO C364
HEALTHY
FAULTY
SCADA SPS com.
SYSTEM INFORMATION UCA2 IED
5 | CommDevice
IED SBUS LINK
HEALTHY
FAULTY
Device link
SYSTEM INFORMATION GATEWAY
6 | DBSwitch_SPC
GTW DATABASE SWITCHING
EXECUTE
DB switch ctrl
6 | CommDevice
GTW SBUS LINK
HEALTHY
FAULTY
Device link
6 | ModeDevice_DPC
GTW FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
6 | OperatingMode
GTW OPERATING MODE
Operating mode
6 | SyncDevice
GTW SYNCHRONISATION STATUS
HEALTHY
FAULTY
Synchronisation
6 | RedSCADA
GTW SCADA PORT COMMUNICATION
ACTIVE
STANDBY
Redundancy SPS
6 | CommSCADA
SCADA CONNECTION STATUS TO GTW
HEALTHY
FAULTY
SCADA SPS com.
6 | CommIED
IED CONNECTION STATUS TO GTW
HEALTHY
FAULTY
IED SPS com.
6| SyncIED
IED SYNCHRONISATION STATUS
HEALTHY
FAULTY
IED SPS Synchro.
6 | ISAGRAFStatus
ISAGRAF STATUS
ISAGRAF status
SYSTEM INFORMATION IEC 61850
7 | CommDevice
IED SBUS LINK
HEALTHY
FAULTY
Device link
7 | OperatingMode
IED OPERATING MODE
Operating mode
7 | ModeDevice_DPC
IED FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
7 | RedDevice
REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
7 | DisturbUCA2
DISTURBANCE FILE ON IED
READY
NOT READY
DREC ready
7 | DisturbLD
LOGICAL DEVICE DISTURBANCE FILE
READY
NOT READY
LD DREC ready
7 | UCA2GenSPS
IEC61850 GENERIC SPS
HEALTHY
FAULTY
IEC61850 gen SPS
7 | UCA2GenDPS
IEC61850 GENERIC DPS
HEALTHY
FAULTY
IEC61850 gen DPS
7 | UCA2GenMPS
IEC61850 GENERIC MPS
IEC61850 gen MPS
7 | UCA2GenSPC
IEC61850 GENERIC SPC
HEALTHY
FAULTY
IEC61850 gen SPC
7 | UCA2GenDPC
IEC61850 GENERIC DPC
HEALTHY
FAULTY
IEC61850 gen DPC
7 | UCA2GenMV
IEC61850 GENERIC MV
IEC61850 gen MV
SYSTEM INFORMATION BAY OI
8 | AgencyStatus
AGENCY STATUS
HEALTHY
FAULTY
Agency status
8 | AutomaticArchiving
AUTOMATIC ARCHIVING STATUS
HEALTHY
FAULTY
Auto archiving
8 | CentralArchiving
HISTORIAN DATABASE STATUS
Central archive
8 | CommDevice
OI SBUS LINK
HEALTHY
FAULTY
Device link
8 | LogQueue
LOGGING QUEUE STATUS
HEALTHY
FAULTY
Log Queue
8 | OperatingMode
OPERATING MODE
Operating mode
8 | RedDevice
REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
8 | SyncDevice
SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
8 | CouplingStatus
SBUS ACQUISITION STATUS
HEALTHY
FAULTY
IEC Coupling
8 | CommS2K_C
CONNECTION STATUS
HEALTHY
FAULTY
OI client link
Menu Option
Menu Option
GE Reserved
Auto generated
Read Only
Port used (on gateway)
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Power Factor
Customer Ref
Panel Number
Customer Ref
Panel Number
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Read Only
Port used (on gateway)
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
GE Reserved
Auto generated
Read Only
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
GE Reserved
Auto generated
Read Only
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
GE Reserved
Auto generated
Read Only
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
GE Reserved
Auto generated
Read Only
Digital Inputs Board Number
Digital Outputs Board Number
Digital Outputs Board Number
DI/DO Board Number
DI/DO Board Number
Analog Input Board Number
Analog Input Board Number
CT/VT Board Number
DSP210 Board Number
Analog Output Board Number
IED name
IED name
IED name
IED name
IED name
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
SERVER OI Name :
CLIENT OI Name :
MiCOM C264 Name :
MiCOM C364 Name :
UCA2 IED Name :
GATEWAY Name :
IEC 61850 Name :
BAY OI Name :
Français
SHEET : Page de Garde Client
SHEET : Page de Garde GE
REVISION
DESCRIPTION
CLIENT
CLIENT
CONTRAT N°
Commande N°
PROJET:
Nom du Projet
Numéro de Document :
Nom du Site
xyz-SC-DTL
SIGNATURE
Titre du document LISTE DE DONNEES DU SYSTEME DE Contrôle DE SOUS-STATION
DSAgile SYSTEME DE COMMANDE DE SOUS-STATION Liste de données
VERIFIE
APPROUVE
EDITE PAR:
TAILLE
PAGES
REVISION
GE Parc Eurêka 81, rue Euclide 34000 MONTPELLIER
ETABLI PAR
SHEET : Journal
Désignation :
Réf. GE :
PACIDL-A
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT DES DONNEES
Révision
Auteur
Compagnie
Modifications
FIN DES DONNEES
SHEET : Equipements
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
LISTE DES EQUIPEMENTS
Légende :
Réservé à GE
Lecture seule
Communication usuelle
Legacy T104 Maître
Legacy T101 Maître
Cartes
Révision
DESCRIPTION (NOM LONG)
COMMUNICATION
REDONDANCE
Nom de la Sous-station
Tranche mimic
MODE DE SYNCHRONISATION
NOM DU RESEAU
Adresse TCP/IP (IEC)
Nom de protocole
Nom de protocole
Nom de protocole
Nom de protocole
Id1 T104M (+ IED Adr)
Id2 T104M (+ IED Adr)
Id3 T104M (+ IED Adr)
Id4 T104M (+ IED Adr)
Id1 T101M (+ IED Adr)
Id2 T101M (+ IED Adr)
Id3 T101M (+ IED Adr)
Id4 T101M (+ IED Adr)
Id Protocole IEC61850
Id Protocole OPC
DIU2xx
Racks d'Extension
Commentaires
Modèle
Nom de la Feuille
RESUME
FIN DES DONNEES
SHEET : Arrangement des Calculateurs
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DESCRIPTION MATERIELLE DES CALCULATEURS MICOM
Légende :
Réservé à GE
Génération automatique
Lecture seule
ERREUR
C264 Rack d'Ext.
C264C Rack d'Ext.
Type de Calculateur (C264/C264C):
Face arriere
PRINCIPAL
REDONDANCE
ECRAN
COMMENTAIRES
Numéro de position devant:
NOM DU CALCULATEUR
NUMERO
BIU240 Port 1
BIU240 Port 2
CPU Port 1
CPU Port 2
Numéro de position arrière:
Type de Protocole
CPU 260 + COMMUNICATION
Vitesse de la communication (en Baud)
RS Type
Parité
Nombre de bits de stop
Nombre de bits
Gestion de RX
Gestion de TX
CTS Câblé
Câblage de DTS
Câblage de CD
Numéro logique:
Câblage de DCR
CPU 270 + COMMUNICATION
Type de Calculateur (C264/C264C):
Face arriere
PRINCIPAL
REDONDANCE
ECRAN
COMMENTAIRES
Numéro de position devant:
NOM DU CALCULATEUR
NUMERO
BIU240 Port 1
BIU240 Port 2
CPU Port 1
CPU Port 2
Numéro de position arrière:
Type de Protocole
TMU2x0 (slot 2/2)
TMU2x0 (slot 1/2)
CPU 260 + COMMUNICATION
Vitesse de la communication (en Baud)
RS Type
Parité
Nombre de bits de stop
Nombre de bits
Gestion de RX
Gestion de TX
CTS Câblé
Câblage de DTS
Câblage de CD
Numéro logique:
Câblage de DCR
CPU 270 + COMMUNICATION
FIN DES DONNEES
SHEET : C264_Template
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DESCRIPTION DU MiCOM C264
Légende :
Nom du Calculateur
Réservé à GE
Calculateur Redondant
Génération automatique
Type de Calculateur (C264/C264C)
Lecture seule
Passerelle
Ports utilisés (sur la passerelle)
SCADA 1
SCADA 2
SCADA 3
SCADA 4
Carte d'entrées numériques DIU32
Carte d'entrées numériques DIU2xx
Numéro de la carte d'entrées numériques
Position de la carte d'entrées numériques
Numéro rack d'extension de la carte d'entrées numériques
Réf. Client
Référence DI
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Carte de sorties numériques DOU20x
Numéro de la carte de sorties numériques
Position de la carte de sorties numériques
Numéro rack d'extension de la carte de sorties numériques
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Carte de sorties numériques HBU20x
Numéro de la carte de sorties numériques HBU
Position de la carte de sorties numériques HBU
Numéro rack d'extension de la carte de sorties numériques HBU
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Carte entrées/sorties numériques CCU20x
Numéro de la carte DI/DO
Position de la carte DI/DO
Numéro rack d'extension de la carte DI/DO
Réf. Client
Référence DI
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Carte d'entrées analogiques AIU21x
Carte d'entrées analogiques AIU20x
Numéro de la carte d'entrées analogiques
Position de la carte d'entrées analogiques
Numéro rack d'extension de la carte d'entrées analogiques
Réf. Client
Référence AI
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Type de Transducteur
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum du transducteur
Correspond à la valeur AI maximum du transducteur
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Module Analogique CT/VT TMU2x0
Numéro du module CT/VT
Position du module CT/VT
Acquisition TC
Acquisition TT
Courant Nominal
Tension Nominale
Modèle de carte CT/VT
Numéro rack d'extension de la carte CT/VT
Réf. Client
Référence AI
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Type d'entrée (U/I)
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum
Correspond à la valeur AI maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
NOM DE l'IED :
ENTREES NUMERIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée numérique de l'IED
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type MODBUS: Mapping Adresse;Bit nb DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU;;Mode de détection T103: Information nb;Adresse CommuneASDU;Mode de détection MODBUS: Fonction;;Mode de détection DNP3: ;;Mode de détection IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
SORTIES NUMERIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte de sortie numérique de l'IED
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type MODBUS: Mapping Adresse;Bit nb DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU;;Type d'Ordre T103: Information nb;Adresse Commune ASDU;Type d'Ordre MODBUS: Fonction;;Type d'Ordre DNP3: ;;Type d'Ordre IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Type (SPC=Simple/DPC=Double)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
ENTREES ANALOGIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée analogique de l'IED
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type; Unité de la MV MODBUS: Mapping Adresse;Format de la donnée DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU T103: Information nb;Adresse Commune ASDU; index dans l'ASDU MODBUS: Fonction DNP3: Non utilisé IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum
Correspond à la valeur AI maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
SORTIES ANALOGIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée analogique de l'IED
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse;Format de Sortie T103: ASDU nb;Fonction type;Format de Sortie MODBUS: Mapping Adresse DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU;;Type d'Ordre T103: Information nb;Adresse Commune ASDU;Type d'Ordre MODBUS: Fonction;;Type d'Ordre DNP3: ;;Type d'Ordre IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum
Correspond à la valeur AI maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
FIN DES DONNEES DE l'IED
GROUPES ENTREES NUMERIQUES
Réf. Client
Référence du Groupes des DI
Données électriques
Description
Libellés
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Opérateur du Groupe
Fonction
Type (S=Simple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 (16 car)
Simple : Texte à l'état électrique = 0 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
ENTREES NUMERIQUES AUTOMATIQUES
Réf. Client
Référence interne DI
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
SORTIES NUMERIQUES AUTOMATIQUES
Réf. Client
Référence interne DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Type (SPC=Simple/DPC=Double)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
ENTREES ANALOGIQUES AUTOMATIQUES
Réf. Client
Référence interne AI
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum du transducteur
Correspond à la valeur AI maximum du transducteur
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Automatisme d'origine (si existant)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
FIN DES DONNEES
SHEET : C364_Template
DESCRIPTION DU MiCOM C364
GROUPES DES ENTREES NUMERIQUES
ENTREES NUMERIQUES AUTOMATIQUES
SORTIES NUMERIQUES AUTOMATIQUES
ENTREES ANALOGIQUES AUTOMATIQUES
SHEET : Données de la Soustation
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DESCRIPTION DES DONNEES DE SOUS-STATION
Légende :
Nom de la Sous-station
Réservé à GE
Contrôle Uniquement
Sous-station
Non / Sous-station / Tranche / Spécifique
Génération automatique
Emplacement prenant le contrôle
SCADA & Local
SCADA / Local / SCADA & Local
Lecture seule
Passerelle
Ports utilisés (sur la passerelle)
SCADA 1
SCADA 2
SCADA 3
SCADA 4
Calculateur par défaut gérant la Sous-station
GROUPES DES DI DE LA SOUS-STATION
Réf. Client
Référence du Groupes des DI
Données électriques
Libellés
Description
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Opérateur du Groupe
Fonction
Type (S=Simple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 (16 car)
Simple : Texte à l'état électrique = 0 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Géré par le Calcultateur
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
FIN DES DONNEES
SHEET : Fonctions Electriques
Désignation :
Réf. GE :
Révision :
N° Document :
PROFILS ELECTRIQUES
Légende :
Réservé à GE
Lecture seule
Profils des entrées numériques simples (SPS)
Profils des entrées numériques systèmes simples (SPS)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la SPS
Condition de la Génération
Alarme audible
Alarme fugitive
Etat 1 confirmation du retard (x100 ms)
Etat 1 niveau de gravité
Etat 0 confirmation du retard (x100 ms)
Etat 0 niveau de gravité
Retard d'apparition de l'alarme (0-120 s)
Mode d'effacement
Paramètres d'impression de la SPS
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Paramètres d'Interverrouillage de la SPS
Reset des valeurs de l'interverrouillage
Niveau haut des valeurs de l'interverrouillage
Paramètres de traitement de la SPS
Libellé de l'état de basculement
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Traitement sur l'état Set
Traitement sur l'état Reset
Traitement sur l'état Ouvert
Traitement sur l'état Fermé
Traitement sur l'état de basculement
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état de basculement
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Masqué dû à la commande
Dépendance SBMC
Basculement du filtrage
Status initial
Reset forcé des valeurs de l'interverrouillage
Niveau haut forcé des valeurs de l'interverrouillage
Reset substitué des valeurs de l'interverrouillage
Niveau haut substitué des valeurs de l'interverrouillage
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage de basculement
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 1 (16 car)
Texte par défaut à l'état électrique = 0 (16 car)
Activer le FSS (forçage / substitution / suppression)
Profils des entrées numériques doubles (DPS)
Profils des entrées numériques systèmes doubles (DPS)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la DPS
Condition de la Génération
Alarme audible
Etat 10 niveau de gravité
Etat 10 confirmation de retard (x100 ms)
Etat 01 niveau de gravité
Etat 01 confirmation du retard (x100 ms)
Complémentarité [00] retard (x100 ms)
Complémentarité [11] retard (x100 ms)
Retard d'apparition de l'alarme (0-120 s)
Mode d'effacement
Paramètres d'impression de la DPS
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Paramètres d'Interverrouillage de la DPS
Valeur "bloqué" de l'interverrouillage
Valeur "ouvert" de l'interverrouillage
Valeur "fermé" de l'interverrouillage
Paramètres de traitement de la DPS
Libellé de l'état bloqué (=DBI 00)
Libellé de l'état indéfini (=DBI 11)
Libellé de l'état de basculement
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Valeur de l'interverrouillage Motion
Traitement sur l'état Ouvert
Traitement sur l'état Fermé
Traitement sur l'état bloqué
Traitement sur l'état indéfini
Traitement sur l'état de basculement
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état bloqué
Gravité d'alarme sur l'état indéfini
Gravité d'alarme sur l'état de basculement
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Alarme fugitive
Masqué dû à la commande
Dépendance SBMC
Basculement du filtrage
Status initial
Bloquage forcé des valeurs de l'interverrouillage
Ouverture forcée des valeurs de l'interverrouillage
Fermeture forcée des valeurs de l'interverrouillage
Bloquage substitué des valeurs de l'interverrouillage
Ouverture substituée des valeurs de l'interverrouillage
Fermeture substituée des valeurs de l'interverrouillage
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage de basculement
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeur de l'interverrouillage indéfini
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 10 (16 car)
Texte par défaut à l'état électrique = 01 (16 car)
Activer le FSS (forçage / substitution / suppression)
Profils des entrées numériques multiples (MPS)
Profils des entrées numériques systèmes multiples (MPS)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la MPS
Condition de la Génération
Alarme audible
Retard d'apparition de l'alarme (0-120 s)
Mode d'effacement
Paramètres d'impression de la MPS
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Paramètres d'Interverrouillage de la MPS
Valeur de l'interverrouillage à l'état 0
Valeur de l'interverrouillage à l'état 1
Valeur de l'interverrouillage à l'état 2
Valeur de l'interverrouillage à l'état 3
Valeur de l'interverrouillage à l'état 4
Valeur de l'interverrouillage à l'état 5
Valeur de l'interverrouillage à l'état 6
Valeur de l'interverrouillage à l'état 7
Valeur de l'interverrouillage à l'état 8
Valeur de l'interverrouillage à l'état 9
Valeur de l'interverrouillage à l'état 10
Valeur de l'interverrouillage à l'état 11
Valeur de l'interverrouillage à l'état 12
Valeur de l'interverrouillage à l'état 13
Valeur de l'interverrouillage à l'état 14
Valeur de l'interverrouillage à l'état 15
Paramètres de traitement de la MPS
Libellé de l'état 0
Libellé de l'état 1
Libellé de l'état 2
Libellé de l'état 3
Libellé de l'état 4
Libellé de l'état 5
Libellé de l'état 6
Libellé de l'état 7
Libellé de l'état 8
Libellé de l'état 9
Libellé de l'état 10
Libellé de l'état 11
Libellé de l'état 12
Libellé de l'état 13
Libellé de l'état 14
Libellé de l'état 15
Libellé de l'état indéfini
Libellé de l'état de basculement
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Traitement sur l'état 0
Traitement sur l'état 1
Traitement sur l'état 2
Traitement sur l'état 3
Traitement sur l'état 4
Traitement sur l'état 5
Traitement sur l'état 6
Traitement sur l'état 7
Traitement sur l'état 8
Traitement sur l'état 9
Traitement sur l'état 10
Traitement sur l'état 11
Traitement sur l'état 12
Traitement sur l'état 13
Traitement sur l'état 14
Traitement sur l'état 15
Traitement sur l'état indéfini
Traitement sur l'état de basculement
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état 0
Gravité d'alarme sur l'état 1
Gravité d'alarme sur l'état 2
Gravité d'alarme sur l'état 3
Gravité d'alarme sur l'état 4
Gravité d'alarme sur l'état 5
Gravité d'alarme sur l'état 6
Gravité d'alarme sur l'état 7
Gravité d'alarme sur l'état 8
Gravité d'alarme sur l'état 9
Gravité d'alarme sur l'état 10
Gravité d'alarme sur l'état 11
Gravité d'alarme sur l'état 12
Gravité d'alarme sur l'état 13
Gravité d'alarme sur l'état 14
Gravité d'alarme sur l'état 15
Gravité d'alarme sur l'état indéfini
Gravité d'alarme sur l'état de basculement
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Masqué dû à la commande
Dépendance SBMC
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage de basculement
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeur de l'interverrouillage indéfini
Activer le FSS (forçage / substitution / suppression)
Profils sorties numériques simples (SPC)
Profils sorties numériques systèmes simples (SPC)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la SPC
Mode d'activation
Mode de sélection avant opération
Temps d'expiration pour la sélection avant opération [0-600s]
Temps d'expiration de l'exécution (si présent) [0..6000000] (x100ms)
Paramètres NACK d'alarme
Etat de l'alarme sur réception négative
Etat du Traitement sur réception Négative
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Paramètres d'Utilisation
Valeur "Off" d'utilisation
Valeur "On" d'utilisation
Paramètres d'Interverrouillage
Valeur "Off" de l'interverrouillage
Valeur "On" de l'interverrouillage
Durée de l'ordre (ms)
Durée de maintien (ms)
Paramètres d'impression de la SPC
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 1 (16 car)
Texte par défaut à l'état électrique = 0 (16 car)
Profils des sorties numériques doubles (DPC)
Profils des sorties numériques systèmes doubles (DPC)
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 10 (16 car)
Texte par défaut à l'état électrique = 01 (16 car)
Paramètres d'impression de la DPC
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Durée d'ouverture (ms)
Durée de fermeture (ms)
Durée de maintien (ms)
Paramètres d'Utilisation
Valeur "Ouvert" d'utilisation 01
Valeur "Fermé" d'utilisation 10
Paramètres d'Interverrouillage
Valeur "Ouvert" de l'interverrouillage 01
Valeur "Fermé" de l'interverrouillage 10
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la DPC
Mode d'activation
Mode de sélection avant opération
Temps d'expiration pour la sélection avant opération [0-600s]
Temps d'expiration de l'exécution (si présent) [0..6000000] (x100ms)
Paramètres NACK d'alarme
Etat de l'alarme sur réception négative
Etat du Traitement sur réception Négative
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Profils SetPoint systèmes
Profils SetPoint
Paramètres d'impression de la SetPoint
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux du SetPoint
Mode d'activation
Mode de sélection avant opération
Temps d'expiration pour la sélection avant opération [0-600s]
Temps d'expiration de l'exécution (si présent) [0..6000000] (x100ms)
Paramètres NACK d'alarme
Etat de l'alarme sur réception négative
Etat du Traitement sur réception Négative
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Profils analogiques
Profils systèmes analogiques
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la MV
Nombre de décimales pour l'affichage [0-4]
Période d'acquisition courte (ms) [100 … 1000] pas de 100
Période d'acquisition longue (ms) [500 … 10000] pas de 500
3eme seuil bas (non ou % de la pleine échelle)
2eme seuil bas (non ou % de la pleine échelle)
1er seuil bas (non ou % de la pleine échelle)
1er seuil haut (non ou % de la pleine échelle)
2em seuil haut (non ou % de la pleine échelle)
3eme seuil haut(non ou % de la pleine échelle)
Graduation
Nombres de pentes [1-20]
Paramètres d'alarme associés à la MV
Condition de la Génération
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Paramètres de traitement de la MV
Libellé de l'état valide
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Libellé de l'état au-dessus de l'échelle
Libellé de l'état indéfini
Libellé de l'état circuit ouvert
Libellé de l'état seuil LLL
Libellé de l'état seuil LL
Libellé de l'état seuil L
Libellé de l'état seuil H
Libellé de l'état seuil HH
Libellé de l'état seuil HHH
Traitement sur l'état valide
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état au-dessus de l'échelle
Traitement sur l'état indéfini
Traitement sur l'état circuit ouvert
Traitement sur l'état LLL seuil
Traitement sur l'état LL seuil
Traitement sur l'état L seuil
Traitement sur l'état H seuil
Traitement sur l'état HH seuil
Traitement sur l'état HHH seuil
Valeur de l'interverrouillage valide
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage forcé
Valeur de l'interverrouillage substitué
Valeur de l'interverrouillage au-dessus de l'échelle
Valeur de l'interverrouillage indéfini
Valeur de l'interverrouillage circuit ouvert
Valeur de l'interverrouillage seuil LLL
Valeur de l'interverrouillage seuil LL
Valeur de l'interverrouillage seuil L
Valeur de l'interverrouillage seuil H
Valeur de l'interverrouillage seuil HH
Valeur de l'interverrouillage seuil HHH
Gravité d'alarme sur l'état valide
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Gravité d'alarme sur l'état au-dessus de l'échelle
Gravité d'alarme sur l'état indéfini
Gravité d'alarme sur l'état circuit ouvert
Gravité d'alarme sur l'état de seuil LLL
Gravité d'alarme sur l'état de seuil LL
Gravité d'alarme sur l'état de seuil L
Gravité d'alarme sur l'état de seuil H
Gravité d'alarme sur l'état de seuil HH
Gravité d'alarme sur l'état de seuil HHH
Calculé
Dépendance SBMC
Format graphique par défaut
Transmission sur événement
Bande morte
Paramètres d'impression de la MV
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Activer le FSS (forçage / substitution / suppression)
FIN DES DONNEES
SHEET : Informations Systemes
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATION SYSTEME DESCRIPTION
Passerelle
Ports utilisés (sur la passerelle)
Légende :
SCADA 1
Réservé à GE
SCADA 2
Génération automatique
SCADA 3
Lecture seule
SCADA 4
INFORMATION SYSTEME DESCRIPTION
Nom de la BAIE OI :
Interface IEC
Données électriques
Description
Libellés/Etats
Description
Interface Scada
Groupes
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Nom de l'IEC 61850 :
Nom de l'UCA2 IED :
Nom du SERVEUR d'E/S :
Nom du CLIENT d'E/S :
Nom du MiCOM C264 :
Nom de la PASSERELLE :
Nom du MiCOM C364 :
INFORMATION SYSTEME PASSERELLE
INFORMATION SYSTEME MiCOM C264
INFORMATION SYSTEME MiCOM C364
INFORMATION SYSTEME CLIENT E/S
INFORMATION SYSTEME SERVER E/S
INFORMATION SYSTEME UCA2 IED
INFORMATION SYSTEME IEC 61850
INFORMATION SYSTEME BAIE OI
Révision
Lien Equipement
Fonction
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : pas utilisé MV : pas utilisé (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 Multiple : pas utilisé MV : pas utilisé (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
LED MV : Non utilisé
xPS : Affichage LCD xPC : Contrôle LCD MV : Affichage LCD
xPS : Affichage HMI xPC : Contrôle HMI MV : Affichage HMI
xPS : Est un retour de position xPC xPC : Est activé par xPS MV : Archivé
Utilisé par ISaGRAF
xPS, MV : Est utilisé par la distribution automatique (GOOSE) xPC : Non utilisé
Nom du Point de Donnée (dans le modèle du SCE)
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Etat agence
Archivage auto
AIU statut
AIU statut
Etat imprimante backup
BIU statut
CCU statut
Archive centrale
Lien équipement
SPS de communication avec l'IED
Lien client OI
SPS de communication avec le SCADA
Top compteur
Couplage UCA2
SPS DB incohérente
contrôle basculement BD
Acquisition DI arrêtée
SPS fichier de perturbo prête
SPS fichier de perturbo prête
DIU statut
DOU statut
Etat horloge external
GHU statut
Etat ISAGRAF
DPS local/distant
DPC de contrôle Local/distant
SPS loc/distant
File du log
MV état calculateur principal
Mode équip.
DPC de contrôle du mode
Mode exploitation
DPS état imprimante
contrôle changement mode redondance
Statut changt redondance
Contrôle changement statut redond.
Mode redondance
SPS de Redondance
Client OI
SPS erreur logicielle
Synchronisation
SPS de Synchronisation de l'IED
DPC de control de test
TMU statut
SPS erreur watchdog
HBU statut
Etat agence
AIU statut
AIU statut
Archivage auto
Etat imp. backup
BIU statut
Perturbo prête
CCU statut
Archive centrale
Top compteur
SPS DB incoh.
ctrl bascul. BD
Lien équipement
Mode équip.
Acq DI arrêtée
DIU statut
DOU statut
Etat horloge ext
GHU statut
IED pert. prête
SPS com. IED
SPS Synchro. IED
Etat ISAGRAF
Etat ISAGRAF
DPC ctrl Loc/dis
DPS local/distant
SPS loc/distant
File du log
MV état princ.
DPC de contrôle du mode
Lien client OI
Mode exploitation
DPS état imprimante
ctrl mode red
ctrl statut red
Stat changt red.
Mode redondance
SPS de Redondance
SPS com. SCADA
SPS erreur soft.
Synchronisation
DPC de control de test
TMU statut
HBU statut
Couplage UCA2
SPS Watchdog
DPS état carte
Mode changt red.
LD DREC prêt
AOU statut
Buff Ov Gtw 1
Buff Ov Gtw 2
Buff Ov OI
Buff Ov OI Bck
All IED status
All rack status
Local alarm ack
Setting done
Setting disc.
Setting in prog.
Setting incoher.
Rack link status
Red.Status
IEC61850 gen SPS
IEC61850 gen DPS
IEC61850 gen MPS
IEC61850 gen SPC
IEC61850 gen DPC
IEC61850 gen MV
FIN DES DONNEES
SHEET : Fonctions Systèmes
Désignation :
Réf. GE :
Révision :
N° Document :
PROFILS SYSTEMES
Légende :
Réservé à GE
Lecture seule
FIN DES DONNEES
SHEET : SystemInformation_Template
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATION SYSTEME DESCRIPTION
Passerelle
Ports utilisés (sur la passerelle)
Légende :
SCADA 1
Réservé à GE
SCADA 2
Génération automatique
SCADA 3
Lecture seule
SCADA 4
FIN DES DONNEES
SHEET : Liste des Tranches
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATIONS SUR LES TRANCHES
Légende :
Réservé à GE
Lecture seule
Nom de la Tranche
Type de Tranche
Calculateur
Calculateur Redondant
Révision
FIN DES DONNEES
SHEET : Modèles T101
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA T101
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Temps de référence
Type de redondance
Adresse du lien
Adresse du lien redondant
Longueur de l'adresse du lien
Adresse commune de l'ASDU
Longueur de l'adresse commune de l'ASDU
Structure d'objet
Longueur maximale de la vue
Cause de longueur de transmission
Cycle Périodique de Mesure
Taille de Temps binaire
Cycle de balayage
Type de lien
Expriration de la trame de test (T3)
Temps d'expiration pour la sélection avant opération
Durée inter trame
Valeur de Qualité de l'état 'Jammed'
Valeur de Qualité de bascule xPS
Valeur de Qualité de l'état 'Inconnu'
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nombre maximum de fichiers SOE
Nb d'évenements dans le fichier SOE plein
Support du fichier de Perturbographie
Adresse du fichier de Perturbographie
Adresse du fichier de Perturbographie T103
Adresse du fichier de Perturbographie S20
Adresse du fichier de Perturbographie M300
Adresse du fichier de Perturbographie SlowWave
Adresse du fichier de Perturbographie FastWave
Nombre maximum de fichiers de perturbographie
Support du fichier de débordement de tampon
Adresse du fichier de débordement de tampon
Condition vide de débordement de tampon
Mode balancé
Mode balancé nb d'essais
Expiration du mode balancé
Séquence d'Information valeur de TS
Séquence d'Information valeur de TM
Séquence d'Information valeur de Compteur
Séquence d'Information écart d'adresse de séparation
SPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Etat Inversé
Balayage de fond
Enregistrement d'évènement
DPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Etat Inversé
Balayage de fond
Enregistrement d'évènement
MPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Utilisation du Bistring
Balayage de fond
Enregistrement d'évènement
SPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
DPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
MV Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Format
Type de Cycle
Enregistrement d'évènement
Valeur Min
Valeur Max
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
Temps d'expiration pour la sélection avant opération [0-65535 s]
Compteur de Donnée de Type
Transmission d'évènements
Groupes [0-4] (0=non)
Prioritée [1-255]
Enregistrement d'évènement
FIN DES DONNEES
SHEET : Modèles DNP3
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA DNP3
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Temps de référence
Utilise TCP/IP
Adresse TCP/IP
Adresse du lien
Classe d'information numérique
Classe de valeur de mesure
Classe de compteur
Format de mesure
Mesure statique
Mesure évènementielle
Format de compteur
Compteur statique
Compteur évènementielle
Durée inter trame
Temps d'expiration pour la sélection avant opération
Message spontané actif
Classe de message spontané
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nb d'évenements dans le fichier SOE plein
SPS Donnée de Type
Transmission d'évènements
Etat Inversé
DPS Donnée de Type
Transmission d'évènements
Etat Inversé
MPS Donnée de Type
Transmission d'évènements
Utilisation du Bistring
SPC Donnée de Type
Type de commande SCADA
DPC Donnée de Type
Type de commande SCADA
MV Donnée de Type
Transmission d'évènements
Format
Valeur Min
Valeur Max
Défini comme compteur
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
Compteur de Donnée de Type
Transmission d'évènements
FIN DES DONNEES
SHEET : Modèles T104
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA T104
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Temps de référence
Adresse TCP/IP
Adresse commune de l'ASDU
Structure de l'adresse
Longueur maximale de la vue
Cycle Périodique de Mesure
Taille de Temps binaire
Cycle de balayage
Expiration de la Connexion (T0)
Expiration de l'APDU (T1)
Expiration de la Réception (T2)
Expriration de la trame de test (T3)
Taille de la fenêtre d'envoi d'acquis négatif
Taille de la fenêtre de réception d'acquis positif
Délai maximum de la Commande
Socket IP #1
Socket IP #2
Socket IP #3
Socket IP #4
Temps d'expiration pour la sélection avant opération
Valeur de Qualité de l'état 'Jammed'
Valeur de Qualité de bascule xPS
Valeur de Qualité de l'état 'Inconnu'
Switchover
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nombre maximum de fichiers SOE
Nb d'évenements dans le fichier SOE plein
Support du fichier de Perturbographie
Adresse du fichier de Perturbographie
Adresse du fichier de Perturbographie T103
Adresse du fichier de Perturbographie S20
Adresse du fichier de Perturbographie M300
Adresse du fichier de Perturbographie SlowWave
Adresse du fichier de Perturbographie FastWave
Nombre maximum de fichiers de perturbographie
Support du fichier de débordement de tampon
Adresse du fichier de débordement de tampon
Condition vide de débordement de tampon
SPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Etat Inversé
Balayage de fond
Enregistrement d'évènement
DPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Etat Inversé
Balayage de fond
Enregistrement d'évènement
MPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Utilisation du Bistring
Balayage de fond
Enregistrement d'évènement
SPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
DPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
MV Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Format
Type de Cycle
Enregistrement d'évènement
Valeur Min
Valeur Max
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
Temps d'expiration pour la sélection avant opération [0-65535 s]
Compteur de Donnée de Type
Transmission d'évènements
Groupes [0-4] (0=non)
Prioritée
Enregistrement d'évènement
FIN DES DONNEES
SHEET : Modèles MODBUS
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA MODBUS
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Utilise TCP/IP
Adresse du lien
Durée inter trame
Parité
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nb d'évenements dans le fichier SOE plein
SPS Donnée de Type
Inversion
DPS Donnée de Type
Utilisation du Double Adressage
Inversion
MV Donnée de Type
Format
Précision [8-16]
Valeur Min
Valeur Max
SetPoint Donnée de Type
Format
Compteur de Donnée de Type
Format
FIN DES DONNEES
SHEET : Modèles OPC
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA OPC
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
OPC valeur pour 'Reset'
OPC valeur pour 'Set'
OPC valeur pour 'Jammed'
OPC valeur pour 'Open'
OPC valeur pour 'Closed'
OPC valeur pour 'Undefined'
OPC valeur pour 'Order Open' (set to 01)
OPC valeur pour 'Order Close' (set to 10)
OPC valeur pour 'Order Reset'
OPC valeur pour 'Order Set'
OPC Bool valeur pour 'Reset'
OPC Bool valeur pour 'Set'
OPC Bool valeur pour 'Jammed'
OPC Bool valeur pour 'Open'
OPC Bool valeur pour 'Closed'
OPC Bool valeur pour 'Undefined'
OPC Bool valeur pour 'Order Open' (set to 01)
OPC Bool valeur pour 'Order Close' (set to 10)
OPC Bool valeur pour 'Order Reset'
OPC Bool valeur pour 'Order Set'
OPC qualité pour 'SelfCheckFault'
OPC qualité pour 'Unknown'
OPC qualité pour 'Toggling'
OPC qualité pour 'Suppressed'
OPC qualité pour 'Forced'
OPC qualité pour 'Substituted'
OPC qualité pour 'Undefined' MPS MV Compteur
OPC qualité pour 'OverRange' MPS MV Compteur
OPC qualité pour 'OpenCircuit' MPS MV Compteur
OPC qualité pour 'LLLThreshold'
OPC qualité pour 'LLThreshold'
OPC qualité pour 'LThreshold'
OPC qualité pour 'HThreshold'
OPC qualité pour 'HHThreshold'
OPC qualité pour 'HHHThreshold'
OPC qualité pour 'Jammed' DPS
OPC qualité pour 'Undefined' DPS
OPC qualité pour 'Valid Set/Closed'
OPC qualité pour 'Valid Reset/Open'
SPS Donnée de Type
Historisation
Format
Etat Inversé
DPS Donnée de Type
Utilisation du Double Adressage
Historisation
Format
Etat Inversé
MPS Donnée de Type
Historisation
SPC Donnée de Type
Format
DPC Donnée de Type
Format
Utilisation du Double Adressage
FIN DES DONNEES
SHEET : Connectique
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT DES DONNEES
FIN DES DONNEES
SHEET : Présence des Colonnes
Cette FEUILLE est utilisée pour indiquer les cellules/colonnes qui sont :
- P : présentes dans toute les FEUILLES mais dont le contenu ne sera pas employé par les outils automatiques
- U : présentes dans toutes les FEUILLES et seront employées par les outils automatiques
- A : Absentes des FEUILLES
- PH :cachées dans toute les FEUILLES mais le contenu ne sera pas employée par les outils automatiques
- UH :cachées dans toutes les FEUILLES et seront employées par les outils automatiques
Réservé à GE
MiCOM CXXX DESCRIPTION
GROUPES DES ENTREES NUMERIQUES
ENTREES NUMERIQUES AUTOMATIQUES
SORTIES NUMERIQUES AUTOMATIQUES
ENTREES ANALOGIQUES AUTOMATIQUES
SHEET : Valeurs par Défaut
Cette FEUILLE est employée pour remplacer des valeurs par de nouvelles.
- placez l'ancienne valeur de paramètre dans la ligne "Ancienne valeur"
- placez la nouvelle valeur du paramètre dans la ligne "Nouvelle valeur"
- Il est possible d'employer des expressions régulières pour filtrer les "Anciennes valeurs".
? Tout caractère simple.
* Zéro caractère ou plus.
# Tout chiffre simple (0-9).
[charlist] Tout caractère simple dans charlist.
[!charlist] Tout caractère simple non compris dans charlist.
- un groupes d'un ou plusieurs caractères (charlist) inclus entre crochets ([ ]) peut être employé à
partir de n'importe quel caractère simple dans la chaine et pouvant inclure presque n'importe quel code de caractère,
y compris des chiffres.
- note : pour utiliser les caractères spéciaux tels le crochet ouvrant ([), le point d'interrogation (?), le signe de nombre (#),
et l'astérisque (*), les mettre entre crochets. Le crochet droit (]) ne peut pas être utilisé dans un Groupes
de sélection, mais peut être employé en dehors
- en employant un trait d'union (-) pour séparer les limites supérieures et inférieures de la liste, charlist peut
indiquer une liste des caractères. Par exemple, [ A-Z ] correspond a toutes les lettres majuscules de l'alphabet.
Les listes multiples sont incluses dans
les crochets sans délimiteurs.
Exemple:
aBBBa' est reconnu par l'expression régulière 'a*a'
F' est reconnu par l'expression régulière '[A-Z]'
F' n'est pas reconnu par l'expression régulière '[!A-Z]'
a2a' est reconnu par l'expression régulière 'a#a'
aM5b' est reconnu par l'expression régulière 'a[L-P]#[!c-e]'
BAT123khg' est reconnu par l'expression régulière 'B?T*'
CAT123khg' n'est pas reconnu par l'expression régulière 'B?T*'
Ancienne valeur
Nouvelle valeur
SHEET : Sélection Colonnes pour Copie
Cette FEUILLE est utilisée pour indiquer les cellules pour lesquelles le contenu sera copié dans une nouvelle version de Dataliste.
Les valeurs possibles sont :
- N : ne pas copier
- C : copier de toute façon (quand la ligne est significative)
- E : copier seulement si la cellule dans la nouvelle version est vide
SHEET : Matrix
Cette FEUILLE indique les cellules/colonnes utilisées pour définir des critères de comparaison.
Les valeurs possibles sont :
- P : présent dans tout la FEUILLE correspondante mais le contenu ne sera pas employé comme Critère de comparaison
- U : présent dans toute les FEUILLEs et sera utilisé pour établir un critère de comparaison
Utiliser ce cas de Matrix
SHEET : AIDE C264
ENTREES COMPTEUR DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée Compteur de l'IED
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type MODBUS: Mapping Adresse;InputFormat DNP3: Adresse IEC: LD;LN T10X MASTER: Information Adresse
T101:Adresse Commune ASDU T103: Information nb;Adresse CommuneASDU MODBUS: Fonction DNP3: Non utilisé IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Adresse Commune ASDU;Data type
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Type du Compteur
Standard: Validation (ms);Invalidité (ms);Cumul (mn) Energy: Facteur d'echelle;Periode de transmission (mn)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Intègre la MV
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
ENTREES COMPTEUR AUTOMATIQUES
ENTREES COMPTEUR AUTOMATIQUES
ENTREES COMPTEUR AUTOMATIQUES
Réf. Client
Référence interne du compteur
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Type du Compteur
Standard: Validation (ms);Invalidité (ms);Cumul (mn) Energy: Facteur d'echelle;Periode de transmission (mn)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Intègre la MV
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
Profils Compteurs
Profils Compteurs systèmes
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux du Compteur
Energie équivalente à un pulse
Calculé
Dépendance SBMC
Format graphique par défaut
Paramètres d'alarme associés à la MV
Condition de la Génération
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Paramètres de traitement du Compteur
Libellé de l'état valide
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état forcé
Libellé de l'état au-dessus de l'échelle
Libellé de l'état indéfini
Traitement sur l'état valide
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état forcé
Traitement sur l'état au-dessus de l'échelle
Traitement sur l'état indéfini
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état valide
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état au-dessus de l'échelle
Gravité d'alarme sur l'état indéfini
Paramètres d'impression du Compteur
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Carte de sorties analogiques AOU20x
Numéro de la carte de sorties analogiques
Position de la carte de sortie analogiques
Numéro rack d'extension de la carte de sorties analogiques
Réf. Client
Référence AO
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur minimum
Correspond à la valeur maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
SORTIES SETPOINT AUTOMATIQUES
SORTIES SETPOINT AUTOMATIQUES
SORTIES SETPOINT AUTOMATIQUES
Réf. Client
Référence SetPoint
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur minimum
Correspond à la valeur maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
SHEET : Modèles IEC61850
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA IEC 61850
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Adresse TCP/IP
FIN DES DONNEES
Carte DSP210
Numéro de la carte DSP210
Position de la carte DSP210
Numéro rack d'extension de la carte DSP210
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
SHEET : Liste des Automatismes
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATIONS SUR LES AUTOMATISMES
Légende :
Réservé à GE
Lecture seule
Numéro
Nom de l'Automatisme
Type d'Automatisme
Calculateur
Calculateur Redondant
Révision
Modèle
FIN DES DONNEES
SHEET : Liste des Liens IEC
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATIONS SUR LES LIENS IEC
Légende :
Réservé à GE
Lecture seule
Clients \ Servers
Révision
FIN DES DONNEES
Sous-station 1
Sous-station 2
Sous-station 3
Sous-station 4
Sous-station 5
Sous-station 6
Sous-station 7
Sous-station 8
Sous-station 9
Sous-station 10
Sous-station 11
Sous-station 12
Sous-station 13
Sous-station 14
Sous-station 15
Sous-station 16
Sous-station 17
Sous-station 18
Sous-station 19
Sous-station 20
Sous-station 21
Sous-station 22
Sous-station 23
Sous-station 24
Sous-station 25
Sous-station 26
Sous-station 27
Sous-station 28
Sous-station 29
Sous-station 30
Sous-station 31
Sous-station 32
Sous-station 33
Sous-station 34
Sous-station 35
Sous-station 36
Sous-station 37
Sous-station 38
Sous-station 39
Sous-station 40
SHEET : Modèles SAS
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA SAS
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Adresse commune de l'ASDU
Longueur de l'adresse commune de l'ASDU
Structure d'objet
Longueur maximale de la vue
Cycle Périodique de Mesure
Taille de Temps binaire
SPS Donnée de Type
Etat Inversé
Envoyé lors de l'Interrogation Générale
DPS Donnée de Type
Etat Inversé
Envoyé lors de l'Interrogation Générale
MPS Donnée de Type
Envoyé lors de l'Interrogation Générale
MV Donnée de Type
Format
Type de Cycle
Valeur Min
Valeur Max
FIN DES DONNEES
SHEET : Modèles CDC Type II
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA CDC TYPE II
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Expiration de la Connexion (T0)
Valeur minimale de mesure
Valeur maximale de mesure
Valeur de mesure invalide
SPS Donnée de Type
Mode de transmission
Etat Inversé
DPS Donnée de Type
Mode de transmission
Etat Inversé
SPC Donnée de Type
Type de commande SCADA
DPC Donnée de Type
Type de commande SCADA
MV Donnée de Type
Valeur Min
Valeur Max
SetPoint Donnée de Type
Valeur Min
Valeur Max
FIN DES DONNEES
SHEET : Modèles GI74
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA GI74
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Adresse TCP/IP
NOM DU RESEAU
Port 1 : Adresse TE
Port 1 : Taille de bloc TE
Port 1 : Expiration du contrôle en ms
Port 1 : Fonction de contrôle HK
Port 1 : Bloc de contrôle HK
Port 1 : Mot de contrôle HK
Port 2 : Adresse TE
Port 2 : Taille de bloc TE
Port 2 : Expiration du contrôle en ms
Port 2 : Fonction de contrôle HK
Port 2 : Bloc de contrôle HK
Port 2 : Mot de contrôle HK
SPS Donnée de Type
Etat Inversé
Type de changement de propagation
DPS Donnée de Type
Etat Inversé
Type de changement de propagation
SPC Donnée de Type
Port de retour
DPC Donnée de Type
Port de retour
MV Donnée de Type
Type de la mesure
Type de changement de propagation
Type de l'unité
FIN DES DONNEES
SHEET : Modèles HNZ
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA HNZ
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Protocole
Temps de référence
Adresse de la Station
Numéro de Station réseau
RTU version base de donnée
Concatenation possible
Taille du Checksum (fcs)
Nombre max de tentatives
Durée inter trame
Taux d'Anticipation
Longueur maximale de la vue
Cycle de Mesure 1 (s)
Cycle de Mesure 2 (s)
Cycle de Mesure 3 (s)
Cycle de Mesure 4 (s)
Fifo : adresse de perte de donnée ou RTU Init (octet.bit)
Fifo : profondeur de tri chronologique (ms)
Fifo : condition vide
Fifo : délai de non activité, nouvelle tentative ou supervision (ms)
RTE : Periode d'analyse de qualité de ligne (s)
RTE : Message Bulle autorisé
RTE : Periode d'envoi d'un message Bulle (s)
RTE : Adresse de TOR Battante (octet.bit)
MV Donnée de Type
Cycle utilisé
Format
Structure de message
Conversion de la valeur originale
Envoyé sur variation
Mode de variation
Bande morte
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
FIN DES DONNEES
Unité par défaut
Unité par défaut pour le point de donnée
Unité par défaut
Unité par défaut pour le point de donnée
Unité par défaut
Unité par défaut pour le point de donnée
SHEET : Modèles T101 MAITRE
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT T101 MAITRE
Légende :
Réservé à GE
Lecture seule
Nom du protocole
Nom court(16 char)
Paramètres généraux du Protocole
Temps de référence
number of retries
station address size (bytes)
ASDU address size (bytes)
info address size (bytes)
taill cause de transmission (bytes)
acknowledgement time-out (x 100 ms)
synchronization cycle (x 10 s)
downgraded cycle (x 100 ms)
Type de lien
test frame time-out (s)
Durée inter trame
Vitesse de transmission (bit/s)
Legacy IED parameters
automatic disturbance
localisation for disturbance file
SPS Donnée de Type
DPS Donnée de Type
contact identifier
MPS Donnée de Type
SPC Donnée de Type
Type de commande
délai d'acquittement
DPC Donnée de Type
Type de commande
Type de contact
délai d'acquittement
MV Donnée de Type
output format
SetPoint Donnée de Type
Type de commande
output format
minimal value
maximal value
délai d'acquittement
Compteur de Donnée de Type
output format
FIN DES DONNEES
SHEET : Modèles T104 MAITRE
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT T104 MAITRE
Légende :
Réservé à GE
Lecture seule
Nom du protocole
Nom court(16 char)
Paramètres généraux du Protocole
Référence horaire
Adresse TCP/IP
Adresse TCP/IP redondée
t0: délai d'établissement de connexion (s)
t1: délai d'envoi ou test d'APDU (s)
t2: délai d'acquittement si pas de données (s)
t3: délai d'envoi de trame de test en cas d'état en veille (s)
k: taille de la fenêtre des trames non transmises
w: taille de la fenêtre des trames reçues
Cycle de synchronisation (x 10s)
Durée inter trame
SPS Donnée de Type
DPS Donnée de Type
Identifiant contact
MPS Donnée de Type
SPC Donnée de Type
Type de commande
Délai acquittement
DPC Donnée de Type
Type de commande
Type de contact
Délai acquittement
MV Donnée de Type
Format de sortie
SetPoint Donnée de Type
Type de commande
Format de sortie
Valeur minimale
Valeur maximale
Délai acquittement
Compteur de Donnée de Type
Format de sortie
FIN DES DONNEES
Description
Standard Signals for 765kV Level
Standard Signals for 400kV Level
Standard Signals for 220kV Level
Standard Signals for Aux System
Description of Remarks
Initital Release
IED MODEL
R_REL670_21M1
R_RELAY NAME_21M2
R_RET670_87T
R_REL670_BIMP
R_REL670_BIMP
R_REL670_HVBUP
R_REL670_LVBUP
R_RET670_87R
R_RET670_64R
R_REL670_BIMP
R_RET670_87R
R_RET670_64R
R_REL670_BIMP
BB_REB500_87BM2
BB_REB670_87BM2
R_REL670_21M1
Voltage Level
R_RET670_87T
Voltage Level
Voltage Level
Additional Relay - Impedance Protection Signals are part of ICT REF PROTECTION RELAY
R_REL670_21T
Voltage Level
R_REL670_21T
Voltage Level
R_REL670_HVBUP
Voltage Level
This Protection Signals are part of ICT BACKUP IV IMPEDANCE PROTECTION RELAY
R_REL670_LVBUP
Voltage Level
R_RET670_87R
Voltage Level
R_RET670_64R
Voltage Level
R_REL670_21R
Voltage Level
BB_REB500_87B
Voltage Level
BB_REB670_87B
Voltage Level
R_RELAY NAME_50BFR
Voltage Level
R_REC670_BCU
Voltage Level
R_REL670_21M1
Voltage Level
R_REL670_21M1
Voltage Level
R_RET670_87T
Voltage Level
Voltage Level
Additional Relay - Impedance Protection Signals are part of ICT REF PROTECTION RELAY
R_REL670_21T
Voltage Level
R_REL670_HVBUP
Voltage Level
R_REL670_LVBUP
Voltage Level
R_RET670_87R
Voltage Level
R_RET670_64R
Voltage Level
R_REL670_21R
Voltage Level
BB_REB500_87B
Voltage Level
BB_REB670_87B
Voltage Level
R_RELAY NAME_50BFR
Voltage Level
R_REC670_BCU
Voltage Level
R_REL670_21M1
Voltage Level
R_REL670_21M1
Voltage Level
R_RET670_87T
Voltage Level
Voltage Level
Additional Relay - The Impedance Preotection is not applicable for 220kV Voltage
R_REL670_21T
Voltage Level
R_REL670_HVBUP
Voltage Level
R_REL670_LVBUP
Voltage Level
R_RET670_87R
Voltage Level
R_RET670_64R
Voltage Level
R_REL670_21R
Voltage Level
BB_REB500_87B
Voltage Level
BB_REB670_87B
Voltage Level
R_RELAY NAME_50BFR
Voltage Level
R_REC670_BCU
Voltage Level
R_REL670_21M1
Voltage Level
R_REC670_BCU
Voltage Level
Voltage Level
Information type
89AE1 POSITION
89AE2 POSITION
89B POSITION
89BE1 POSITION
89BE2 POSITION
CB B-PH POSITION
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
COMMANDS
89A CONTROL
89AE1 CONTROL
89AE2 CONTROL
89B CONTROL
89BE1 CONTROL
89BE2 CONTROL
CB CONTROL
86A TRIP RELAY RESET
86B TRIP RELAY RESET
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R -PH CURRENT
I-Y -PH CURRENT
I-B -PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B PH COUNTER
CB-R PH COUNTER
CB-Y PH COUNTER
BINARY INPUT (Single Point)
LED RESET
BCU MODE
87B RELAY SUPERVISION
86A TRIP RELAY RESET
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY RESET
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
AC KIOSK SMOKE DETECTED
AC KIOSK HEAT FIRE DETECTED
CB AC SUPPLY FAIL
AC SUPPLY-1 ON
AC SUPPLY-1/2 FAIL
AC SUPPLY-2 ON
CB DC SUPPLY-1 FAIL
CB DC SUPPLY-2 FAIL
CB LOCAL
EMERGENCY/MANUAL CLOSE
EMERGENCY/MANUAL TRIP
CB POLE DISCREPANCY OPERATED
CB SF6 LOCKOUT
CB SF6 LOW ALARM
CB SPRING CHARGE STATUS
DC SUPPLY-1 FAIL
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
Information type
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
DIRECTIONAL DMT TRIP
DIRECTIONAL DMT PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-1 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-1 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-2 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-2 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-1 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-1 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-2 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-2 PICKUP
DIRECTIONAL IDMT EARTHFAULT TRIP
DIRECTIONAL IDMT EARTHFAULT PICKUP
DIRECTIONAL IDMT OVERCURRENT TRIP
DIRECTIONAL IDMT OVERCURRENT PICKUP
DMT TRIP
DMT PICKUP
DMT OVERCURRENT STAGE-1 TRIP
DMT OVERCURRENT STAGE-1 PICKUP
DMT OVERCURRENT STAGE-2 TRIP
DMT OVERCURRENT STAGE-2 PICKUP
DMT OVERCURRENT STAGE-3 TRIP
DMT OVERCURRENT STAGE-3 PICKUP
DMT EARTHFAULT STAGE-1 TRIP
DMT EARTHFAULT STAGE-1 PICKUP
DMT EARTHFAULT STAGE-2 TRIP
DMT EARTHFAULT STAGE-2 PICKUP
THERMAL OVERLOAD TRIP
THERMAL OVERLOAD PICKUP
GENERAL TRIP
GENERAL PICKUP
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
Information type
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
89A POSITION
89AE POSITION
89B POSITION
89C POSITION
89T POSITION
89TE1 POSITION
89TE2 POSITION
BINARY INPUT (Single Point)
LED RESET
BCU MODE
86A TRIP RELAY RESET
86A TRIP RELAY FAULTY
86A TRIP RELAY OPTD
86B TRIP RELAY RESET
86B TRIP RELAY FAULTY
86B TRIP RELAY OPTD
87B RELAY FAULTY
AC KIOSK HEAT FIRE DETECTION
AC KIOSK SMOKE DETECTION
CB AC SUPPLY FAIL
AC-1/2 POWER FAIL
BAY IN NORMAL MODE
BAY IN TRANSFER MODE
CB DC-1 SUPPLY FAIL
CB DC-2 SUPPLY FAIL
CB IN LOCAL MODE
EMERGENCY/MANUAL CB CLOSE
EMERGENCY/MANUAL CB TRIP
CB POLE DISCREPANCY OPTD
CB SF6 LOCKOUT
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB SPRING CHARGED
DC SUPPLY-1 FAIL
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
NORMAL MODE
TRANSFER MODE
GOOSE RECEIPT FAIL/TROUBLE
TIME SYNCHRONISATION ERROR
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB B-PH COUNTER
CB R-PH COUNTER
CB Y-PH COUNTER
COMMANDS
89A CONTROL
89AE CONTROL
89B CONTROL
89C CONTROL
89T CONTROL
89TE1 CONTROL
89TE2 CONTROL
CB CONTROL
TRANSFER/NORMALCONTROL
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
89AE1 POSITION
89AE2 POSITION
89BE POSITION
89A POSITION
89B POSITION
89L POSITION
89LE POSITION
89 BE1 POSITION
89 BE2 POSITION
THE LOGICAL NODE FOR BUS EARTH SWITCHES, ISOLATOR & EARTHSWITCHES FOR 3 PH/1PH REACTORS & ITCs, e.g 89 BR, BRE, LR, LRE, RS1, RS2, RS1E, 89T,TE, 89AE2, 89BE2 MAY BE ASSIGNED AS PER AVAILABILITY/SCHEME
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
BCU LOCAL
BCU REMOTE
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
TRIP RELAY SUPERVISION
CARRIER CHANNEL-2 OUT
MAIN-2 RELAY FAULTY
EMERGENCY/MANUAL TRIP
SPEECH CHANNEL FAIL
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
89A POLE DESCREPENCY
89B POLE DESCREPENCY
CB DC SUPPLY-1/2 FAIL
CB SPRING NOT CHARGED B-PH
CB SPRING NOT CHARGED R-PH
CB SPRING NOT CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
86B TRIP RELAY FAULTY
86A TRIP RELAY FAULTY
86A TRIP RELAY OPERATED
86B TRIP RELAY OPERATED
89L POLE DESCREPENCY
CARRIER CHANNEL-1 OUT
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
CB POLE DESCREPENCY OPTD-1
CB POLE DESCREPENCY OPTD-2
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB READY
EMERGENCY/MANUAL CB CLOSE
DEVICE HEALTHY
CB POSITION NO SYNC
CB CLOSE INTERLOCK
89AE2 OPEN INTERLOCK
89BE OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89L OPEN INTERLOCK
89LE OPEN INTERLOCK
DC-1 FAIL
DC-2 FAIL
BUSBAR 7ES-B1 OPEN(BUS EARTH SWITCH)
BUSBAR 7ES-B2 OPEN(BUS EARTH SWITCH)
BUSBAR 7ES-B1 CLOSE INTERLOCK
BUSBAR 7ES-B2 CLOSE INTERLOCK
GOOSE RECEIPT FAIL/TROUBLE
DFR/DR FAIL ALARM
GOOSE RECEIPT FAIL/TROUBLE
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
A/R READY
A/R UNSUCCESSFUL
A/R START
A/R SUCCESSFUL
RECLAIM IN PROGRESS
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
Tie CB A/R PRIORITY CLOSE
MAIN/TIE BCU HEALTHY
AR SINGLE PHASE TRIP PERMITTED
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
RELAY IN TEST MODE
SETTINGS CHANGED
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
CB R-PHASE OPERATION COUNTER
CB Y-PHASE OPERATION COUNTER
CB B-PHASE OPERATION COUNTER
COMMANDS
CB CONTROL
89AE1 CONTROL
89AE2 CONTROL
89BE CONTROL
89A CONTROL
89B CONTROL
89L CONTROL
89LE CONTROL
CB CONTROL NO SYNC
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
A/R ON CONTROL
A/R OFF CONTROL
MAIN-1 LED RESET
MAIN-2 LED RESET
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
FAULT CURRENT
FAULT LOCATION DISTANCE
MAIN-1 CARRIER RECEIVE CHANNEL-1
MAIN-1 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-1
MAIN-2 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-2
MAIN-2 CARRIER SEND CHANNEL-2
MAIN-1 CARRIER RECEIVE CHANNEL-2
MAIN-1 CARRIER SEND CHANNEL-2
DT RECEIVE CHANNEL-1
DT SEND CHANNEL-1
DT RECEIVE CHANNEL-2
DT SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER SEND CHANNEL-2
CARRIER SEND CHANNEL-1
DIRECT TRIP RECEIVED CHANNEL-1
DIRECT TRIP SEND CHANNEL-1
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
BINARY INPUT (Single Point)
DIRECT TRIP SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
NO VOLTAGE IN LINE
A/R BLOCK
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
DIRECT TRIP SEND CHANNEL-1
GOOSE RECEIPT FAIL/TROUBLE
MAIN-2 RELAY FAIL
89L OPEN FOR STUB
DIRECT TRIP RECEIVED CHANNEL-1
LBB OPERATED
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
EMERGENCY/MANUAL CLOSE
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER FAULTY
SOTF PICKUP
SOTF TRIP( OC)
SOTF TRIP( IMPEDANCE Z1B)
CARRIER SEND CHANNEL-1
CARRIER SEND CHANNEL-2
DIRECT TRIP RECEIVED CHANNEL-2
CARRIER RECEIVED
CARRIER ADDIED TRIP/Z COM. TRIP
MAIN A/R OPTD
TIE A/R OPTD
CB MANUAL CLOSE
CB MANUAL TRIP
86 GROUP-A OPTD
86 GROUP-B OPTD
MAIN A/R START
TIE A/R START
DISTANCE ZONE-1 PICKUP
DISTANCE PROTN ZONE-1 TRIP
DISTANCE PROTN ZONE-1 R-PH TRIP
DISTANCE PROTN ZONE-1 Y-PH TRIP
DISTANCE PROTN ZONE-1 B-PH TRIP
DISTANCE ZONE-2 PICKUP
DISTANCE PROTN ZONE-2 TRIP
DISTANCE PROTN ZONE-2 R-PH TRIP
DISTANCE PROTN ZONE-2 Y-PH TRIP
DISTANCE PROTN ZONE-2 B-PH TRIP
DISTANCE ZONE-3 PICKUP
DISTANCE PROTN ZONE-3 TRIP
DISTANCE ZONE-4 PICKUP
DISTANCE PROTN ZONE-4 TRIP
DISTANCE PROTN ZONE-4 R-PH TRIP
DISTANCE PROTN ZONE-4 Y-PH TRIP
DISTANCE PROTN ZONE-4 B-PH TRIP
DISTANCE PROTN ZONE-1B PICKUP
DISTANCE PROTN ZONE-1B TRIP
DISTANCE PROTN ZONE-1B B-PH TRIP
DISTANCE PROTN ZONE-1B R-PH TRIP
DISTANCE PROTN ZONE-1B Y-PH TRIP
DISTANCE PROTN ZONE-5 PICKUP
STUB PICKUP
STUB OPERATED
DEF FAULT PICKUP
DEF FAULT TRIP
OVERVOLTAGE STAGE-1-PH-N PICKUP
OVERVOLTAGE STAGE-1 -PH-N TRIP
OVERVOLTAGE STAGE-2-PH-N PICKUP
OVERVOLTAGE STAGE-2-PH-N TRIP
OVERVOLTAGE STAGE-1-PH-PH PICKUP
OVERVOLTAGE STAGE-1-PH-PH TRIP
OVERVOLTAGE STAGE-2-PH-PH PICKUP
OVERVOLTAGE STAGE-2-PH-PH TRIP
POWER SWING ZONE-1 DETECTED
POWER SWING ZONE-1 BLOCK
POWER SWING ZONE-1B DETECTED
POWER SWING ZONE-1B BLOCK
POWER SWING ZONE-2 DETECTED
POWER SWING ZONE-2 BLOCK
POWER SWING ZONE-3 DETECTED
POWER SWING ZONE-3 BLOCK
POWER SWING ZONE-4 DETECTED
POWER SWING ZONE-4 BLOCK
BUSBAR PROTN OPTD
RELAY LED RESET
MAIN BCU FAIL
TIE BCU FAIL
MANUAL DR TRIGGER
GENERAL TRIP
DEVICE HEALTHY
MAIN-2 PROTN OPTD
STUB BLOCKED
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
FAULT CURRENT
FAULT LOCATION DISTANCE
MAIN-1 CARRIER RECEIVE CHANNEL-1
MAIN-1 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-1
MAIN-2 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-2
MAIN-2 CARRIER SEND CHANNEL-2
MAIN-1 CARRIER RECEIVE CHANNEL-2
MAIN-1 CARRIER SEND CHANNEL-2
DT RECEIVE CHANNEL-1
DT SEND CHANNEL-1
DT RECEIVE CHANNEL-2
DT SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER SEND CHANNEL-2
CARRIER SEND CHANNEL-1
DIRECT TRIP RECEIVED CHANNEL-1
DIRECT TRIP SEND CHANNEL-1
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
BINARY INPUT (Single Point)
LINE DIFFERENTIAL GENERAL TIP
LINE DIFFERENTIAL REMOTE TRIP
LINE DIFFERENTIAL R-PH TRIP
LINE DIFFERENTIAL Y-PH TRIP
LINE DIFFERENTIAL -PH TRIP
LINE COMMUNICATION CHANNEL-1 FAULTY
LINE COMMUNICATION CHANNEL-2 FAULTY
DIRECT TRIP SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
NO VOLTAGE IN LINE
A/R BLOCK
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
DIRECT TRIP SEND CHANNEL-1
GOOSE RECEIPT FAIL/TROUBLE
MAIN-2 RELAY FAIL
89L OPEN FOR STUB
DIRECT TRIP RECEIVED CHANNEL-1
LBB OPERATED
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
EMERGENCY/MANUAL CLOSE
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER FAULTY
SOTF PICKUP
SOTF TRIP( OC)
SOTF TRIP( IMPEDANCE Z1B)
CARRIER SEND CHANNEL-1
CARRIER SEND CHANNEL-2
DIRECT TRIP RECEIVED CHANNEL-2
CARRIER RECEIVED
CARRIER ADDIED TRIP/Z COM. TRIP
MAIN A/R OPTD
TIE A/R OPTD
CB MANUAL CLOSE
CB MANUAL TRIP
86 GROUP-A OPTD
86 GROUP-B OPTD
MAIN A/R START
TIE A/R START
DISTANCE ZONE-1 PICKUP
DISTANCE PROTN ZONE-1 TRIP
DISTANCE PROTN ZONE-1 R-PH TRIP
DISTANCE PROTN ZONE-1 Y-PH TRIP
DISTANCE PROTN ZONE-1 B-PH TRIP
DISTANCE ZONE-2 PICKUP
DISTANCE PROTN ZONE-2 TRIP
DISTANCE PROTN ZONE-2 R-PH TRIP
DISTANCE PROTN ZONE-2 Y-PH TRIP
DISTANCE PROTN ZONE-2 B-PH TRIP
DISTANCE ZONE-3 PICKUP
DISTANCE PROTN ZONE-3 TRIP
DISTANCE ZONE-4 PICKUP
DISTANCE PROTN ZONE-4 TRIP
DISTANCE PROTN ZONE-4 R-PH TRIP
DISTANCE PROTN ZONE-4 Y-PH TRIP
DISTANCE PROTN ZONE-4 B-PH TRIP
DISTANCE PROTN ZONE-1B PICKUP
DISTANCE PROTN ZONE-1B TRIP
DISTANCE PROTN ZONE-1B B-PH TRIP
DISTANCE PROTN ZONE-1B R-PH TRIP
DISTANCE PROTN ZONE-1B Y-PH TRIP
DISTANCE PROTN ZONE-5 PICKUP
STUB PICKUP
STUB OPERATED
DEF FAULT PICKUP
DEF FAULT TRIP
OVERVOLTAGE STAGE-1-PH-N PICKUP
OVERVOLTAGE STAGE-1 -PH-N TRIP
OVERVOLTAGE STAGE-2-PH-N PICKUP
OVERVOLTAGE STAGE-2-PH-N TRIP
OVERVOLTAGE STAGE-1-PH-PH PICKUP
OVERVOLTAGE STAGE-1-PH-PH TRIP
OVERVOLTAGE STAGE-2-PH-PH PICKUP
OVERVOLTAGE STAGE-2-PH-PH TRIP
POWER SWING ZONE-1 DETECTED
POWER SWING ZONE-1 BLOCK
POWER SWING ZONE-1B DETECTED
POWER SWING ZONE-1B BLOCK
POWER SWING ZONE-2 DETECTED
POWER SWING ZONE-2 BLOCK
POWER SWING ZONE-3 DETECTED
POWER SWING ZONE-3 BLOCK
POWER SWING ZONE-4 DETECTED
POWER SWING ZONE-4 BLOCK
BUSBAR PROTN OPTD
RELAY LED RESET
MAIN BCU FAIL
TIE BCU FAIL
MANUAL DR TRIGGER
GENERAL TRIP
DEVICE HEALTHY
MAIN-2 PROTN OPTD
STUB BLOCKED
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
Information type
GENERAL TRIP Y-PH
GENERAL TRIP B-PH
TRIP COMMAND BUS-BUS-3 B-PH
TRIP COMMAND BUS-BUS-3 Y-PH
TRIP COMMAND BUS-BUS-3 R-PH
TRIP COMMAND BUS-2 B- PH
TRIP COMMAND BUS-2 Y- PH
TRIP COMMAND BUS-2 R- PH
TRIP COMMAND BUS-1 B- PH
TRIP COMMAND BUS-1 Y- PH
TRIP COMMAND BUS-1 R- PH
BREAKER FAILURE OPERATED BUS-3 B-PH
BREAKER FAILURE OPERATED BUS-3 Y-PH
BREAKER FAILURE OPERATED BUS-3 R-PH
BREAKER FAILURE OPERATED BUS-2 B-PH
BREAKER FAILURE OPERATED BUS-2 Y-PH
BREAKER FAILURE OPERATED BUS-2 R-PH
BREAKER FAILURE OPERATED BUS-1 B-PH
BREAKER FAILURE OPERATED BUS-1 Y-PH
BREAKER FAILURE OPERATED BUS-1 R-PH
BUS-3 BUS CT SUPERVISION ALARM
BUS-2 CT SUPERVISION ALARM
BUS-1 CT SUPERVISION ALARM
BLOCKED TRIP COMMAND BUS-3 (BUS-3)
BLOCKED TRIP COMMAND BUS-2
BLOCKED TRIP COMMAND BUS-1
BLOCKED BY BUS-3
BLOCKED BY BUS-2
BLOCKED BY BUS-1
BUS-3 PROTECTION BLOCKED BY HANDLE
BUS-1 PROTECTION BLOCKED BY HANDLE
BUS-2 PROTECTION BLOCKED BY HANDLE
BLOCKED BREAKER FAILURE PROTECTION BUS-3
BLOCKED BREAKER FAILURE PROTECTION BUS-2
BLOCKED BREAKER FAILURE PROTECTION BUS-1
BUS-3 BUS TRIP
BUSBAR TRIP
BUS ZONE 1 TRIP
BUS ZONE 2 TRIP
BLOCKED BREAKER FAILURE PROTECTION BUS-3
BLOCKED BREAKER FAILURE PROTECTION BUS-2
BLOCKED BREAKER FAILURE PROTECTION BUS-1
B213- BAY UNIT OUT OF SERVICE
B213- BAY UNIT FAILURE
B212- BAY UNIT OUT OF SERVICE
B212- BAY UNIT FAILURE
B211- BAY UNIT OUT OF SERVICE
B211- BAY UNIT FAILURE
B210- BAY UNIT OUT OF SERVICE
B210- BAY UNIT FAILURE
B209- BAY UNIT OUT OF SERVICE
B209- BAY UNIT FAILURE
B208- BAY UNIT OUT OF SERVICE
B208- BAY UNIT FAILURE
B207- BAY UNIT OUT OF SERVICE
B207- BAY UNIT FAILURE
B206- BAY UNIT OUT OF SERVICE
B206- BAY UNIT FAILURE
B205- BAY UNIT OUT OF SERVICE
B205- BAY UNIT FAILURE
B204- BAY UNIT OUT OF SERVICE
B204- BAY UNIT FAILURE
B203- BAY UNIT OUT OF SERVICE
B203- BAY UNIT FAILURE
B202- BAY UNIT OUT OF SERVICE
B202- BAY UNIT FAILURE
B201- BAY UNIT OUT OF SERVICE
B201- BAY UNIT FAILURE
TIME SYNCHRONISATION ERROR
BAY UNIT FAILURE GROUP ALARM
BAY OUT OF SERVICE GROUP ALARM
BUS-3 BUS SWITCH OUT
DC SOURCE-2 FAIL
DC SOURCE-1 FAIL
BUS-2 SWITCH OUT
BUS-1 SWITCH OUT
LED RESET
Busbar-1 Zone OPERATED
Busbar-2 Zone OPERATED
BUS-3 BUSBAR ZONE OPERATED
BUS-1 BLOCK DUE TO INDERM STATE
BUS-1 BLOCK DUE TO COMMUNICATION FAIL
BUS-2 BLOCK DUE TO INDERM STATE
BUS-2 BLOCK DUE TO COMMUNICATION FAIL
BUS-3 BLOCK DUE TO INDERM STATE
BUS-3 BLOCK DUE TO COMMUNICATION FAIL
LBB TRIP
LBB RETRIP
GOOSE RECEIPT FAIL/TROUBLE
BUSBAR CHECKZONE ALARM
BUSBAR CHECKZONE TRIP
BREAKER FAILURE - BUSBAR 1 BLOCKED
BREAKER FAILURE - BUSBAR 2 BLOCKED
ISOLATOR IN INTERMEDIATE STATUS
BAY N TRIP
BUSBAR BLOCKED DUE TO COMMUNICATION ERROR_Bay_n
BAY_N_BREAKER FAILURE R-PH INITIATION
BAY_N_BREAKER FAILURE Y-PH INITIATION
BAY_N_BREAKER FAILURE B-PH INITIATION
BAY_N_BREAKER FAILURE 3PH INITIATION
BAY_N_EXTERNAL BUSBAR ZONE n
BAY_N_BREAKER FAILURE RETRIP
BAY_N_BREAKER FAILURE BACKTRIP
BAY_N_BREAKER FAILURE RPH- RETRIP
BAY_N_BREAKER FAILURE YPH- RETRIP
BAY_N_BREAKER FAILURE BPH- RETRIP
BBP CENTRAL UNIT IED UNHEALTHY
SETTING CHANGE
BUS ZONE MERGE/BUS INTERCONNECT ALARM
RELAY IN TEST MODE
Voltage Level
Information type
89AE POSITION
89B POSITION
89C POSITION
89C POSITION
89CE1 POSITION
89CE2 POSITION
CB B-PH POSITION
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
BINARY INPUT (Single Point)
LED RESET
BCU MODE
86A TRIP RELAY RESET
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY RESET
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
87B TRIP RELAY SUPERVISION
AC KIOSK HEAT FIRE DETECTED
AC KIOSK SMOKE DETECTED
CB AC SUPPLY FAIL
AC SUPPLY-1 ON
AC SUPPLY-1/2 FAIL
AC SUPPLY-2 ON
NORMAL MODE
TRANSFER MODE
BUS-1 VT RESET
BUS-2 VT RESET
CB DC SUPPLY-1 FAIL
CB DC SUPPLY-2 FAIL
CB LOCAL
EMERGENCY/MANUAL CLOSE
EMERGENCY/MANUAL TRIP
CB POLE DISCREPANCY OPERATED
CB SF6 LOCKOUT
CB SF6 LOW ALARM
CB SPRING CHARGE STATUS
DC SUPPLY-1 FAIL
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
TRANSFER RESET
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R -PH CURRENT
I-Y -PH CURRENT
I-B -PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B PH COUNTER
CB-R PH COUNTER
CB-Y PH COUNTER
COMMANDS
89A CONTROL
89AE CONTROL
89B CONTROL
89C CONTROL
89C CONTROL
89CE1 CONTROL
89CE2 CONTROL
CB CONTROL
TRANSFER/NORMAL CONTROL
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB Y-PH POSITION
CB B-PH POSITION
CB POSITION
89AE POSITION
89AE2 POSITION
89BE1 POSITION
89BE POSITION
89RE-B POSITION
89RE POSITION
89RE-Y POSITION
89A POSITION
89B POSITION
89R-B POSITION
89R POSITION
89R-Y POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB SF6 GAS PRESSURE LOCKOUT
89A POLE DESCREPENCY
89B POLE DESCREPENCY
CB DC SUPPLY-1/2 FAIL
CB SPRING CHARGED
CB SF6 GAS PRESSURE LOCKOUT
EMERGENCY/MANUAL CB TRIP
PSD DEVICE HEALTHY
PSD DEVICE IN SERVICE
WTI ALARM
OTI ALARM
PSD ALARM
PSD SYNCH DATA ERROR
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
CB TC-1 FAULTY
CB TC-2 FAULTY
CB POLE DISCREPANCY
CB SF6 GAS PRESSURE REFILL LOW ALARM
BUS-1 VT RESET
BUS-2 VT RESET
LINE VT RESET
CB READY
CB POSITION NO SYNC
GAS PRESSURE LOW ALARM-1 GC401-1 Y-PH
GAS PRESSURE LOW ALARM -1 GC401-1 B-PH
GAS PRESSURE LOW ALARM-1 GC401-2 R-PH
GAS PRESSURE LOW ALARM -1 GC401-2 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-3 R-PH
GAS PRESSURE LOW ALARM -1 GC401-3 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-3 B-PH
GAS PRESSURE LOW ALARM-1 GC401-4 R-PH
GAS PRESSURE LOW ALARM -1 GC401-4 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-4 B-PH
GAS PRESSURE LOW ALARM-1 GC401-5 R-PH
GAS PRESSURE LOW ALARM -1 GC401-5 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-5 B-PH
GAS PRESSURE LOW ALARM-1 GC401-6 R-PH
GAS PRESSURE LOW ALARM -1 GC401-6 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-6 B-PH
GAS PRESSURE LOW ALARM-1 GC401-7 R-PH
GAS PRESSURE LOW ALARM -1 GC401-7 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-7 B-PH
GAS PRESSURE LOW ALARM-2 GC401-1
GAS PRESSURE LOW ALARM-2 GC401-2
GAS PRESSURE LOW ALARM-2 GC401-3
GAS PRESSURE LOW ALARM-2 GC401-4
GAS PRESSURE LOW ALARM-2 GC401-5
GAS PRESSURE LOW ALARM-2 GC401-6
GAS PRESSURE LOW ALARM-2 GC401-7
GAS COMPARTMENT ZONE TRIP GC401-52
GAS COMPARTMENT ZONE TRIP GC401-1
GAS COMPARTMENT ZONE TRIP GC401-2
GAS COMPARTMENT ZONE TRIP GC401-3
GAS COMPARTMENT ZONE TRIP GC401-4
GAS COMPARTMENT ZONE TRIP GC401-5
GAS COMPARTMENT ZONE TRIP GC401-6
GAS COMPARTMENT ZONE TRIP GC401-7
GAS PRESSURE LOW ALARM-1 GC401-8 R-PH
GAS PRESSURE LOW ALARM -1 GC401-8 Y-PH
GAS PRESSURE LOW ALARM-1 GC401-8 B-PH
GAS PRESSURE LOW ALARM-2 GC401-8
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
CB CLOSE INTERLOCK
89AE OPEN INTERLOCK
89AE2 OPEN INTERLOCK
89BE OPEN INTERLOCK
89BE2 OPEN INTERLOCK
89BRE OPEN INTERLOCK
89RE-R-PH OPEN INTERLOCK
89RE-Y-PH OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89BR OPEN INTERLOCK
89R-R-PH OPEN INTERLOCK
89R-Y-PH OPEN INTERLOCK
DC -1/2 SUPPLY HEALTHY
89BR POLE DISCREPANCY ALARM
CT SF6 ALARM
CT SF6 LOCKOUT
PSD IN POSITION
PSD OUT POSITION
PSD OPENING PROBLEM
PSD CLOSING PROBLEM
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
COMMANDS
89BR CONTROL
89B CONTROL
89A CONTROL
89BRE CONTROL
89BE CONTROL
89AE CONTROL
CB CONTROL
CB CONTROL NO SYNC
86B TRIP RELAY RESET COMMAND
86A TRIP RELAY RESET COMMAND
PSD SWITCH IN CONTROL
PSD SWITCH OUT CONTROL
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
BCU UNHEALTHY
GOOSE RECEIPT FAIL/TROUBLE
DC SUPPLY-1 FAIL
PRV-1 TRIP
TIME SYNCHRONISATION ERROR
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
COMMUNICATION STATUS
WTI TRIP
MAIN TANK BUCHHOLZ A TRIP
PNRV ALARM
MAIN TANK BUCHHOLZ A ALARM
WTI ALARM
OTI TRIP
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
87.1R RELAY UNHEALTHY
64.2R RELAY UNHEALTHY
GOOSE RECEIPT FAIL/TROUBLE
MOG ALARM
MAIN TANK BUCHHOLZ ALARM
OTI TRIP
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
BACKUP IMPEDENCE ACTIVE
BACKUP IMPEDENCE BLOCKED
BACKUP IMPEDENCE ZONE-1 PICKUP
BACKUP IMPEDENCE ZONE-1 TRIP
BACKUP IMPEDENCE R-PH TRIP
BACKUP IMPEDENCE Y-PH TRIP
BACKUP IMPEDENCE B-PH TRIP
FAULT DISTANCE
GENERAL TRIP
GENERAL PICKUP
COMMUNICATION STATUS
LOW OIL LEVEL ALARM
NON-DIRECTIONAL OVERCURRENT PICKUP
NON-DIRECTIONAL OVERCURRENT TRIP
HIGH OIL LEVEL ALARM
REACTOR MB AC FAIL
FLOW SENSITIVE VALVE ALARM
WTI ALARM
OTI ALARM
PRV-1 ALARM
PRV-2 ALARM
SETTINGS CHANGED
RELAY IN TEST MODE
NON-DIRECTIONAL EARTHFAULT TRIP
NON-DIRECTIONAL EARTHFAULT START
Voltage Level
INFORMATION TYPE
GOOSE RECEIPT FAIL/TROUBLE
REACTOR CB OPEN
TIME SYNCHRONISATION ERROR
DIFFERENTIAL PROTECTION ACTIVE
DIFFERENTIAL PROTECTION BLOCKED
DIFFERENTIAL TRIP R-PH
DIFFERENTIAL TRIP Y-PH
DIFFERENTIAL TRIP B-PH
DIFFERENTIAL STAGE 1 TRIP
DIFFERENTIAL STAGE 1 PICKUP
DIFFERENTIAL STAGE 2 TRIP
DIFFERENTIAL STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
COMMUNICATION STATUS
MAIN CB OPEN
TIE CB OPEN
2ND HARMONIC
5TH HARMONIC
SUDDEN PRESSURE RELAY TRIP ALARM
BUCHHOLZ ALARM-B
BUCHHOLZ-A TRIP
PRESSURE RELIEF VALVE-2 OPERATED(TRIP)
WTI TRIP
64R RELAY UNHEALTHY
86-A/B TRIP RELAY OPTD
DC-2 FAIL
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
S89T-B POSITION
89AE POSITION
89BE POSITION
89TE B-PH POSITION
89TE R-PH POSITION
89TE Y-PH POSITION
89STE B-PH POSITION
89STE R-PH POSITION
89STE Y-PH POSITION
89STE POSITION
89A POSITION
89B POSITION
89T B-PH POSITION
89T R-PH POSITION
89T Y-PH POSITION
89TS1_TS2 B-PH POSITION
89TS1_TS2 R-PH POSITION
89TS1_TS2 Y-PH POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
LED RESET
BCU MODE
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB SF6 GAS PRESSURE LOCKOUT
CB DC SUPPLY-1/2 FAIL
CB SF6 GAS PRESSURE LOCKOUT
POLE DESCREPENCY
CB SPRING CHARGED B-PH
CB SPRING CHARGED R-PH
CB SPRING CHARGED Y-PH
89A POLE DESCREPENCY
89B POLE DESCREPENCY
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
EMERGENCY/MANUAL TRIP
CB TC-1 FAULTY
CB TC-2 FAULTY
PSD DEVICE IN SERVICE
PSD DEVICE HEALTHY
PSD ALARM
PSD SYNCH DATA ERROR
DGA GAS HIGH ALARM SP-PH
DGA GAS HIGH ALARM R_Y_B-PH
MOISTER HIGH ALARM R_Y_B-PH
MOISTER HIGH ALARM SP-PH
OLTC OIL TEMP HIGH B-PH ALARM
OLTC OIL TEMP HIGH R-PH ALARM
OLTC OIL TEMP HIGH SP-PH ALARM
OLTC OIL TEMP HIGH Y-PH ALARM
OLTC OIL TEMP LOW B-PH ALARM
OLTC OIL TEMP LOW R-PH ALARM
OLTC OIL TEMP LOW SP-PH ALARM
OLTC OIL TEMP LOW Y-PH ALARM
OLTC LOW OIL REFILL B-PH ALARM
OLTC LOW OIL REFILL SP-PH ALARM
OLTC LOW OIL REFILL R-PH ALARM
OLTC LOW OIL REFILL Y-PH ALARM
RPH MOG LOW OIL LEVEL ALARM
YPH MOG LOW OIL LEVEL ALARM
BPH MOG LOW OIL LEVEL ALARM
SP-PH MOG LOW OIL LEVEL ALARM
RPH MOG HIGH OIL LEVEL ALARM
YPH MOG HIGH OIL LEVEL ALARM
BPH MOG HIGH OIL LEVEL ALARM
SP-PH MOG HIGH OIL LEVEL ALARM
R-PH OIL FLOW SENSITIVE VALVE ALARM
Y-PH OIL FLOW SENSITIVE VALVE ALARM
B-PH OIL FLOW SENSITIVE VALVE ALARM
SP-PH OIL FLOW SENSITIVE VALVE ALARM
RPH PUMP FAIL - BANK A
RPH PUMP FAIL - BANK B
RPH PUMP FAIL - BANK C
RPH PUMP FAIL - BANK D
YPH PUMP FAIL - BANK A
YPH PUMP FAIL - BANK B
YPH PUMP FAIL - BANK C
YPH PUMP FAIL - BANK D
BPH PUMP FAIL - BANK A
BPH PUMP FAIL - BANK B
BPH PUMP FAIL - BANK C
BPH PUMP FAIL - BANK D
SPH PUMP FAIL - BANK A
SPH PUMP FAIL - BANK B
SPH PUMP FAIL - BANK C
SPH PUMP FAIL - BANK D
RPH THERMAL OVERLOAD TRIP - BANK A
RPH THERMAL OVERLOAD TRIP - BANK B
RPH THERMAL OVERLOAD TRIP - BANK C
RPH THERMAL OVERLOAD TRIP - BANK D
YPH THERMAL OVERLOAD TRIP - BANK A
YPH THERMAL OVERLOAD TRIP - BANK B
YPH THERMAL OVERLOAD TRIP - BANK C
YPH THERMAL OVERLOAD TRIP - BANK D
BPH THERMAL OVERLOAD TRIP - BANK A
BPH THERMAL OVERLOAD TRIP - BANK B
BPH THERMAL OVERLOAD TRIP - BANK C
BPH THERMAL OVERLOAD TRIP - BANK D
SPH THERMAL OVERLOAD TRIP - BANK A
SPH THERMAL OVERLOAD TRIP - BANK B
SPH THERMAL OVERLOAD TRIP - BANK C
SPH THERMAL OVERLOAD TRIP - BANK D
RPH LOW OIL FLOW/REVERSE FLOW - BANK A
RPH LOW OIL FLOW/REVERSE FLOW - BANK B
RPH LOW OIL FLOW/REVERSE FLOW - BANK C
RPH LOW OIL FLOW/REVERSE FLOW - BANK D
YPH LOW OIL FLOW/REVERSE FLOW - BANK A
YPH LOW OIL FLOW/REVERSE FLOW - BANK B
YPH LOW OIL FLOW/REVERSE FLOW - BANK C
YPH LOW OIL FLOW/REVERSE FLOW - BANK D
BPH LOW OIL FLOW/REVERSE FLOW - BANK A
BPH LOW OIL FLOW/REVERSE FLOW - BANK B
BPH LOW OIL FLOW/REVERSE FLOW - BANK C
BPH LOW OIL FLOW/REVERSE FLOW - BANK D
SPH LOW OIL FLOW/REVERSE FLOW - BANK A
SPH LOW OIL FLOW/REVERSE FLOW - BANK B
SPH LOW OIL FLOW/REVERSE FLOW - BANK C
SPH LOW OIL FLOW/REVERSE FLOW - BANK D
RPH COOLER CONTROL SUPPLY FAIL
YPH COOLER CONTROL SUPPLY FAIL
BPH COOLER CONTROL SUPPLY FAIL
SPH COOLER CONTROL SUPPLY FAIL
RPH SUPPLY CHANGE OVER FAIL
YPH SUPPLY CHANGE OVER FAIL
BPH SUPPLY CHANGE OVER FAIL
SPH SUPPLY CHANGE OVER FAIL
RPH SUPPLY - A FAIL
YPH SUPPLY - A FAIL
BPH SUPPLY - A FAIL
SPH SUPPLY - A FAIL
RPH SUPPLY - B FAIL
YPH SUPPLY - B FAIL
BPH SUPPLY - B FAIL
SPH SUPPLY - B FAIL
RPH OLTC MOTOR OVERLOAD
RPH TAP CHANGE IN PROGRESS
RPH TAP CHANGE IN COMPLETE
RPH OLTC IN LOCAL
RPH OLTC IN REMOTE
RPH TAP CHANGE CONTROL SUPPLY FAIL
RPH LOWEST POSITION REACHDED
RPH HIGHESHT POSITION REACHDED
RPH OLTC RAISE COMMAND
RPH OLTC LOWER COMMAND
YPH OLTC MOTOR OVERLOAD
YPH TAP CHANGE IN PROGRESS
YPH TAP CHANGE IN COMPLETE
YPH OLTC IN LOCAL
YPH OLTC IN REMOTE
YPH TAP CHANGE CONTROL SUPPLY FAIL
YPH LOWEST POSITION REACHDED
YPH HIGHESHT POSITION REACHDED
YPH OLTC RAISE COMMAND
YPH OLTC LOWER COMMAND
BPH OLTC MOTOR OVERLOAD
BPH TAP CHANGE IN PROGRESS
BPH TAP CHANGE IN COMPLETE
BPH OLTC IN LOCAL
BPH OLTC IN REMOTE
BPH TAP CHANGE CONTROL SUPPLY FAIL
BPH LOWEST POSITION REACHDED
BPH HIGHESHT POSITION REACHDED
BPH OLTC RAISE COMMAND
BPH OLTC LOWER COMMAND
SPH OLTC MOTOR OVERLOAD
SPH TAP CHANGE IN PROGRESS
SPH TAP CHANGE IN COMPLETE
SPH OLTC IN LOCAL
SPH OLTC IN REMOTE
SPH TAP CHANGE CONTROL SUPPLY FAIL
SPH LOWEST POSITION REACHDED
SPH HIGHESHT POSITION REACHDED
SPH OLTC RAISE COMMAND
SPH OLTC LOWER COMMAND
OTI B-PH ALARM
OTI R-PH ALARM
OTI SP-PH ALARM
OTI Y-PH ALARM
PUMP FAIL B-PH
PUMP FAIL R-PH
PUMP FAIL SP-PH
PUMP FAIL Y-PH
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
WTI HV_IV_LV ALARM B-PH
WTI HV_IV_LV ALARM R-PH
WTI HV_IV_LV ALARM SP-PH
WTI HV_IV_LV ALARM Y-PH
CB SF6 LOW PRESSURE ALARM B-PH
CB SF6 LOW PRESSURE ALARM R-PH
CB SF6 LOW PRESSURE ALARM Y-PH
BUS-1 VT RESET
BUS-2 VT RESET
LINE VT RESET
CB READY
EMERGENCY/MANUAL CB CLOSE
GOOSE RECEIPT FAIL/TROUBLE
CB POSITION NO SYNC
CB CLOSE INTERLOCK
89AE1 OPEN INTERLOCK
89AE2 OPEN INTERLOCK
89BE OPEN INTERLOCK
89TE B-PH OPEN INTERLOCK
89TE R-PH OPEN INTERLOCK
89TE Y-PH OPEN INTERLOCK
TSE1 B-PH OPEN INTERLOCK
TSE1 R-PH OPEN INTERLOCK
TSE1 Y-PH OPEN INTERLOCK
TSE2 OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89T B-PH OPEN INTERLOCK
89T R-PH OPEN INTERLOCK
89T Y-PH OPEN INTERLOCK
89TS1_TS2 B-PH OPEN INTERLOCK
89TS1_TS2 R-PH OPEN INTERLOCK
89TS1_TS2 Y-PH OPEN INTERLOCK
RELAY IN TEST MODE
SETTINGS CHANGED
ICT-n R PH OUT OF SERVICE
ICT-n Y PH OUT OF SERVICE
ICT-n B PH OUT OF SERVICE
ICT SPARE PH IN SERVICE IN ICT-N
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
COMMANDS
CB CONTROL
89AE1 CONTROL
89AE2 CONTROL
89BE CONTROL
89TE B-PH CONTROL
89TE R-PH CONTROL
89TE Y-PH CONTROL
TSE1 B-PH CONTROL
TSE1 R-PH CONTROL
TSE1 Y-PH CONTROL
TSE2 CONTROL
89A CONTROL
89B CONTROL
89T B-PH CONTROL
89T R-PH CONTROL
89TS1_TS2 B-PH CONTROL
89TS1_TS2 R-PH CONTROL
89TS1_TS2 Y-PH CONTROL
89T Y-PH CONTROL
CB CONTROL NO SYN
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
TAP RAISER
TAP LOWER
Voltage Level
INFORMATION TYPE
DMT EARTHFAULT STAGE 1 PICKUP
DMT EARTHFAULT STAGE 2 TRIP
DMT EARTHFAULT STAGE 2 PICKUP
IDMT EARTHFAULT TRIP
IDMT EARTHFAULT PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
OLTC OSR TRIP R PH
OLTC OSR TRIP Y PH
OLTC OSR TRIP B PH
OIL FLOW SENSITIVE VALVE TRIP R PH
OIL FLOW SENSITIVE VALVE TRIP Y PH
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
RAPID PRESSURE TRIP B-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
BUCHHOLZ 1 TRIP B-PH
OTI TRIP B-PH
BUCHHOLZ 2 ALARM B-PH
PRD OLTC TRIP B-PH
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
TIE CB OPEN
BUCHHOLZ 1 TRIP R-PH
BUCHHOLZ 2 ALARM R-PH
OTI TRIP R-PH
PRD OLTC TRIP R-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
OTI TRIP Y-PH
PRD OLTC TRIP Y-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
BUCHHOLZ 2 ALARM Y-PH
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
87.1_99HV HV RELAY UNHEALTHY
BCU UNHEALTHY
DIRECTIONAL DMT OVERCURRENT STAGE-1 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-1 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-1 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-2 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-2 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-2 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-3 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-3 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-1 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-1 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-1 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-2 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-2 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-2 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-3 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-3 PICKUP
DIRECTIONAL IDMT OVERCURRENT BLOCKED
DIRECTIONAL IDMT OVERCURRENT TRIP
DIRECTIONAL IDMT EARTHFAULT BLOCKED
DIRECTIONAL IDMT EARTHFAULT TRIP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
BUCHHOLZ 2 TRIP SP-PH
WTI HV_IV_LV TRIP SP-PH
WTI HV_LV_IV TRIP B-PH
WTI HV_LV_IV TRIP R-PH
WTI HV_LV_IV TRIP Y-PH
DIRECTIONAL DMT OVERCURRENT STAGE-1 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-1 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-1 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-2 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-2 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-2 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-3 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-3 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-1 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-1 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-1 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-2 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-2 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-2 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-3 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-3 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
67.1 LV RELAY UNHEALTHY
RAPID PRESSURE TRIP Y-PH
OIL FLOW SENSITIVE VALVE TRIP B PH
OIL FLOW SENSITIVE VALVE TRIP SP PH
OVERFLUX STAGE-2 OPERATED
OVERFLUX STAGE-2 PICKUP
OVERFLUX STAGE-1 OPERATED
OVERFLUX STAGE-1 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
OVERFLUX ALARM
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
MAIN CB OPEN
MAIN CB CLOSE
REF PROTECTION OPERATED
86 A/86 B RELAY OPERATED
BUCHHOLZ 2 TRIP R-PH
BUCHHOLZ 2 TRIP Y-PH
BUCHHOLZ 2 TRIP B-PH
BUCHHOLZ 1 ALARM R-PH
BUCHHOLZ 1 ALARM Y-PH
BUCHHOLZ 1ALARM B-PH
BUCHHOLZ 1 ALARM SP-PH
TIE CB OPEN
PRD1, 2 & 3 TRIP SP-PH
PRD1, 2 & 3 TRIP R-PH
PRD1, 2 & 3 TRIP Y-PH
PRD1, 2 & 3 TRIP B-PH
2nd HARMONIC BLOCK PH-R
2nd HARMONIC BLOCK PH-Y
2nd HARMONIC BLOCK PH-B
5th HARMONIC BLOCK PH-R
5th HARMONIC BLOCK PH-Y
5th HARMONIC BLOCK PH-B
DIFFERENTIAL TRIP
DIFFERENTIAL TRIP R-PH
DIFFERENTIAL TRIP Y-PH
DIFFERENTIAL TRIP B-PH
DIFFERENTIAL STAGE-1 TRIP
DIFFERENTIAL STAGE-1 PICKUP
DIFFERENTIAL STAGE-2 TRIP
DIFFERENTIAL STAGE-2 PICKUP
OVER FLUX TRIP
OVERFLUX STAGE-2 TRIP
OVERFLUX STAGE-1 TRIP
OVERFLUX HV ALARM
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
Telegram Address
WTI TRIP B-PH
WTI TRIP Y-PH
64.2-R_Y_B SP RELAY UNHEALTHY
TIME SYNCHRONISATION ERROR
BACKUP IMPEDENCE ZONE-1 START
BACKUP IMPEDENCE ZONE-1 TRIP
BACKUP IMPEDENCE R-PH TRIP
BACKUP IMPEDENCE Y-PH TRIP
BACKUP IMPEDENCE B-PH TRIP
BACKUP IMPEDENCE BLOCKED
GENERAL TRIP
NON-DIRECTIONAL OVERCURRENT TRIP
NON-DIRECTIONAL OVERCURRENT START
DEVICE HEALTHY
NO VOLTAGE IN LINE
VT FUSE FAILURE
SETTINGS CHANGED
RELAY IN TEST MODE
NON-DIRECTIONAL EARTHFAULT TRIP
NON-DIRECTIONAL EARTHFAULT START
IED MODEL
Voltage Level
INFORMATION TYPE
CB Y-PH POSITION
CB B-PH POSITION
CB POSITION
89AE POSITION
89BE POSITION
89LRE1 POSITION
89RE-B POSITION
89RE-R POSITION
89RE-Y POSITION
89RSE1-B POSITION
89RSE1-R POSITION
89RSE1-Y POSITION
89A POSITION
89B POSITION
89LR POSITION
89R-B POSITION
89R-R POSITION
89R-Y POSITION
89RS1_RS2-B POSITION
89RS1_RS2-R POSITION
89RS1_RS2-Y POSITION
NGR CB POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
BCU MODE
CB DC SUPPLY-1/2 FAIL
CB SPRING CHARGED B-PH
CB SPRING CHARGED R-PH
CB SPRING CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
A/R BLOCK MAIN1-1
A/R BLOCK MAIN-2
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
CARRIER CHANNEL-1 OUT
CARRIER CHANNEL-2 OUT
MAIN-2 RELAY UNHEALTHY
EMERGENCY/MANUAL CB TRIP
MAIN TANK HIGH LEVEL ALARM B-PH
MAIN TANK HIGH LEVEL ALARM R-PH
MAIN TANK HIGH LEVEL ALARM Y-PH
MAIN TANK LOW LEVEL ALARM B-PH
MAIN TANK LOW LEVEL ALARM R-PH
MAIN TANK LOW LEVEL ALARM Y-PH
OTI ALARM B-PH
OTI ALARM R-PH
OTI ALARM Y-PH
SPEECH CHANNEL FAIL
CB TC-1 FAULTY
CB TC-2 FAULTY
WTI ALARM B-PH
WTI ALARM R-PH
WTI ALARM Y-PH
CB POLE DESCREPENCY ALARM
CB SF6 GAS PRESSURE REFILL LOW ALARM
TIME SYNCHRONISATION ERROR
BUS-1 VT RESET
BUS-2 VT RESET
LINE VT RESET
EMERGENCY/MANUAL CB CLOSE
A/R FUNCTION ON
CB READY FOR A/R
A/R UNSUCCESSFUL
A/R SUCCESSFUL
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
A/R FUNCTION OFF
A/R FUNCTION ON
CB POSITION NO SYNC
89AE OPEN INTERLOCK
89BE OPEN INTERLOCK
89LE OPEN INTERLOCK
89RE-B-PH OPEN INTERLOCK
89RE-R-PH OPEN INTERLOCK
89RE-Y-PH OPEN INTERLOCK
89RSE1-B-PH OPEN INTERLOCK
89RSE1-R-PH OPEN INTERLOCK
89RSE1-Y-PH OPEN INTERLOCK
89A-PH OPEN INTERLOCK
89B-PH OPEN INTERLOCK
89L-PH OPEN INTERLOCK
89R-B-PH OPEN INTERLOCK
89R-R-PH OPEN INTERLOCK
89R-Y-PH OPEN INTERLOCK
89RS1_RS2-B-PH OPEN INTERLOCK
89RS1_RS2-R-PH OPEN INTERLOCK
89RS1_RS2-Y-PH OPEN INTERLOCK
NGR CB CLOSE INTERLOCK
RELAY IN TEST MODE
SETTINGS CHANGED
REACTOR-n R PH OUT OF SERVICE
REACTOR-n Y PH OUT OF SERVICE
REACTOR-n B PH OUT OF SERVICE
REACTOR SPARE PH IN SERVICE IN REACTOR-N
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
NGR CB TC-1 FAULTY
NGR CB TC-2 FAULTY
NGR CB DC FAULTY
NGR CB AC FAULTY
NGR CB SPRING NOT CHARGED
NGR CB SF6 GAS LOW
NGR CB SF6 CB TROUBLE ALARM
NGR MECHANICAL TRIPPING IF ASSIGNED
MEASUREMENTS
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
COMMANDS
CB CONTROL
89AE CONTROL
89BE CONTROL
89LE CONTROL
89RE-B CONTROL
89RE-R CONTROL
89RE-Y CONTROL
89RSE1-B CONTROL
89RSE1-R CONTROL
89RSE1-Y CONTROL
89A CONTROL
89B CONTROL
89L CONTROL
89R-B CONTROL
89R-R CONTROL
89R-Y CONTROL
89RS1_RS2-B CONTROL
89RS1_RS2-R CONTROL
89RS1_RS2-Y CONTROL
NGR CB CONTROL
CB CONTROL NO SYNC
NGR CB CONTROL NO SYNC
86B TRIP RELAY RESET COMMAND
86A TRIP RELAY RESET COMMAND
A/R ON CONTROL
A/R OFF CONTROL
Voltage Level
INFORMATION TYPE
WTI TRIP Y-PH
OTI TRIP B-PH
OTI TRIP R-PH
BUCHHOLZ-1/2 TRIP R-PH
BUCHHOLZ-1/2 TRIP Y-PH
BUCHHOLZ-1/2 TRIP B-PH
NGR PRV TRIP
BCU-1/2 RELAY FAIL
REACTOR DC-2 FAIL
GROUP-B PROTECTION RELAY FAIL
BACKUP IMPEDENCE ZONE-1 PICKUP
BACKUP IMPEDENCE ZONE-1 TRIP
BACKUP IMPEDENCE R-PH TRIP
BACKUP IMPEDENCE Y-PH TRIP
BACKUP IMPEDENCE B-PH TRIP
GENERAL TRIP
BACKUP IMPEDENCE BLOCKED
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
VOLTAGE ABSENT
VT FUSE FAILURE
TIME SYNCHRONISATION ERROR
BROKEN CONDUCTOR
NON-DIRECTIONAL OVERCURRENT TRIP
NON-DIRECTIONAL OVERCURRENT START
NON-DIRECTIONAL EARTHFAULT TRIP
NON-DIRECTIONAL EARTHFAULT START
SETTINGS CHANGED
RELAY IN TEST MODE
NGR CLOSE COMMAND BY E/F PICKUP(5 SEC)
NGR CLOSE COMMAND BY MECH TRIP
Voltage Level
INFORMATION TYPE
BUCHHOLZ TRIP R-PH
BUCHHOLZ TRIP Y-PH
OTI TRIP Y-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
NGR THERMAL OVERLOAD TRIP
TIME SYNCHRONISATION ERROR
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
PRV-1 TRIP R-PH(NO)
PRV-1 TRIP Y-PH(NO)
PRV-1 TRIP B-PH(NC)
PRV-1 TRIP R-PH(NC)
PRV-1 TRIP Y-PH(NC)
PRV-2 TRIP B-PH(NO)
PRV-2 TRIP R-PH(NO)
PRV-2 TRIP Y-PH(NO)
PRV-2 TRIP B-PH(NC)
PRV-2 TRIP R-PH(NC)
PRV-2 TRIP Y-PH(NC)
PRV-1 TRIP B-PH
PRV-1 TRIP R-PH
PRV-1 TRIP Y-PH
PRV-2 TRIP B-PH
PRV-2 TRIP R-PH
PRV-2 TRIP Y-PH
WTI TRIP R-PH
DIFFERENTIAL TRIP R-PH
DIFFERENTIAL TRIP Y-PH
DIFFERENTIAL TRIP B-PH
DIFFERENTIAL STAGE 1 OPERATED
DIFFERENTIAL STAGE 1 PICKUP
DIFFERENTIAL STAGE 2 OPERATED
DIFFERENTIAL STAGE 2 PICKUP
GENERAL TRIP
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
TIME SYNCHRONISATION ERROR
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
89AE1 POSITION
89AE2 POSITION
89BE POSITION
89A POSITION
89B POSITION
89L POSITION
89LE POSITION
89 BE1 POSITION
89 BE2 POSITION
THE LOGICAL NODE FOR BUS EARTH SWITCHES, ISOLATOR & EARTHSWITCHES FOR 3 PH/1PH REACTORS & ITCs, e.g 89 BR, BRE, LR, LRE, RS1, RS2, RS1E, 89T,TE, 89AE2, 89BE2 MAY BE ASSIGNED AS PER AVAILABILITY/SCHEME
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
BCU LOCAL
BCU REMOTE
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
TRIP RELAY SUPERVISION
CARRIER CHANNEL-2 OUT
MAIN-2 RELAY FAULTY
EMERGENCY/MANUAL TRIP
SPEECH CHANNEL FAIL
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
89A POLE DESCREPENCY
89B POLE DESCREPENCY
CB DC SUPPLY-1/2 FAIL
CB SPRING NOT CHARGED B-PH
CB SPRING NOT CHARGED R-PH
CB SPRING NOT CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
86B TRIP RELAY FAULTY
86A TRIP RELAY FAULTY
86A TRIP RELAY OPERATED
86B TRIP RELAY OPERATED
89L POLE DESCREPENCY
CARRIER CHANNEL-1 OUT
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
CB POLE DESCREPENCY OPTD-1
CB POLE DESCREPENCY OPTD-2
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB READY
EMERGENCY/MANUAL CB CLOSE
DEVICE HEALTHY
CB POSITION NO SYNC
CB CLOSE INTERLOCK
89AE2 OPEN INTERLOCK
89BE OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89L OPEN INTERLOCK
89LE OPEN INTERLOCK
DC-1 FAIL
DC-2 FAIL
BUSBAR 7ES-B1 OPEN(BUS EARTH SWITCH)
BUSBAR 7ES-B2 OPEN(BUS EARTH SWITCH)
BUSBAR 7ES-B1 CLOSE INTERLOCK
BUSBAR 7ES-B2 CLOSE INTERLOCK
GOOSE RECEIPT FAIL/TROUBLE
DFR/DR FAIL ALARM
GOOSE RECEIPT FAIL/TROUBLE
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
A/R READY
A/R UNSUCCESSFUL
A/R START
A/R SUCCESSFUL
RECLAIM IN PROGRESS
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
Tie CB A/R PRIORITY CLOSE
MAIN/TIE BCU HEALTHY
AR SINGLE PHASE TRIP PERMITTED
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
RELAY IN TEST MODE
SETTINGS CHANGED
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
CB R-PHASE OPERATION COUNTER
CB Y-PHASE OPERATION COUNTER
CB B-PHASE OPERATION COUNTER
COMMANDS
CB CONTROL
89AE1 CONTROL
89AE2 CONTROL
89BE CONTROL
89A CONTROL
89B CONTROL
89L CONTROL
89LE CONTROL
CB CONTROL NO SYNC
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
A/R ON CONTROL
A/R OFF CONTROL
MAIN-1 LED RESET
MAIN-2 LED RESET
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
FAULT CURRENT
FAULT LOCATION DISTANCE
MAIN-1 CARRIER RECEIVE CHANNEL-1
MAIN-1 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-1
MAIN-2 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-2
MAIN-2 CARRIER SEND CHANNEL-2
MAIN-1 CARRIER RECEIVE CHANNEL-2
MAIN-1 CARRIER SEND CHANNEL-2
DT RECEIVE CHANNEL-1
DT SEND CHANNEL-1
DT RECEIVE CHANNEL-2
DT SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER SEND CHANNEL-2
CARRIER SEND CHANNEL-1
DIRECT TRIP RECEIVED CHANNEL-1
DIRECT TRIP SEND CHANNEL-1
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
BINARY INPUT (Single Point)
DIRECT TRIP SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
NO VOLTAGE IN LINE
A/R BLOCK
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
DIRECT TRIP SEND CHANNEL-1
GOOSE RECEIPT FAIL/TROUBLE
MAIN-2 RELAY FAIL
89L OPEN FOR STUB
DIRECT TRIP RECEIVED CHANNEL-1
LBB OPERATED
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
EMERGENCY/MANUAL CLOSE
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER FAULTY
SOTF PICKUP
SOTF TRIP( OC)
SOTF TRIP( IMPEDANCE Z1B)
CARRIER SEND CHANNEL-1
CARRIER SEND CHANNEL-2
DIRECT TRIP RECEIVED CHANNEL-2
CARRIER RECEIVED
CARRIER ADDIED TRIP/Z COM. TRIP
MAIN A/R OPTD
TIE A/R OPTD
CB MANUAL CLOSE
CB MANUAL TRIP
86 GROUP-A OPTD
86 GROUP-B OPTD
MAIN A/R START
TIE A/R START
DISTANCE ZONE-1 PICKUP
DISTANCE PROTN ZONE-1 TRIP
DISTANCE PROTN ZONE-1 R-PH TRIP
DISTANCE PROTN ZONE-1 Y-PH TRIP
DISTANCE PROTN ZONE-1 B-PH TRIP
DISTANCE ZONE-2 PICKUP
DISTANCE PROTN ZONE-2 TRIP
DISTANCE PROTN ZONE-2 R-PH TRIP
DISTANCE PROTN ZONE-2 Y-PH TRIP
DISTANCE PROTN ZONE-2 B-PH TRIP
DISTANCE ZONE-3 PICKUP
DISTANCE PROTN ZONE-3 TRIP
DISTANCE ZONE-4 PICKUP
DISTANCE PROTN ZONE-4 TRIP
DISTANCE PROTN ZONE-4 R-PH TRIP
DISTANCE PROTN ZONE-4 Y-PH TRIP
DISTANCE PROTN ZONE-4 B-PH TRIP
DISTANCE PROTN ZONE-1B PICKUP
DISTANCE PROTN ZONE-1B TRIP
DISTANCE PROTN ZONE-1B B-PH TRIP
DISTANCE PROTN ZONE-1B R-PH TRIP
DISTANCE PROTN ZONE-1B Y-PH TRIP
DISTANCE PROTN ZONE-5 PICKUP
STUB PICKUP
STUB OPERATED
DEF FAULT PICKUP
DEF FAULT TRIP
OVERVOLTAGE STAGE-1-PH-N PICKUP
OVERVOLTAGE STAGE-1 -PH-N TRIP
OVERVOLTAGE STAGE-2-PH-N PICKUP
OVERVOLTAGE STAGE-2-PH-N TRIP
OVERVOLTAGE STAGE-1-PH-PH PICKUP
OVERVOLTAGE STAGE-1-PH-PH TRIP
OVERVOLTAGE STAGE-2-PH-PH PICKUP
OVERVOLTAGE STAGE-2-PH-PH TRIP
POWER SWING ZONE-1 DETECTED
POWER SWING ZONE-1 BLOCK
POWER SWING ZONE-1B DETECTED
POWER SWING ZONE-1B BLOCK
POWER SWING ZONE-2 DETECTED
POWER SWING ZONE-2 BLOCK
POWER SWING ZONE-3 DETECTED
POWER SWING ZONE-3 BLOCK
POWER SWING ZONE-4 DETECTED
POWER SWING ZONE-4 BLOCK
BUSBAR PROTN OPTD
RELAY LED RESET
MAIN BCU FAIL
TIE BCU FAIL
MANUAL DR TRIGGER
GENERAL TRIP
DEVICE HEALTHY
MAIN-2 PROTN OPTD
STUB BLOCKED
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
FAULT CURRENT
FAULT LOCATION DISTANCE
MAIN-1 CARRIER RECEIVE CHANNEL-1
MAIN-1 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-1
MAIN-2 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-2
MAIN-2 CARRIER SEND CHANNEL-2
MAIN-1 CARRIER RECEIVE CHANNEL-2
MAIN-1 CARRIER SEND CHANNEL-2
DT RECEIVE CHANNEL-1
DT SEND CHANNEL-1
DT RECEIVE CHANNEL-2
DT SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER SEND CHANNEL-2
CARRIER SEND CHANNEL-1
DIRECT TRIP RECEIVED CHANNEL-1
DIRECT TRIP SEND CHANNEL-1
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
BINARY INPUT (Single Point)
LINE DIFFERENTIAL GENERAL TIP
LINE DIFFERENTIAL REMOTE TRIP
LINE DIFFERENTIAL R-PH TRIP
LINE DIFFERENTIAL Y-PH TRIP
LINE DIFFERENTIAL -PH TRIP
LINE COMMUNICATION CHANNEL-1 FAULTY
LINE COMMUNICATION CHANNEL-2 FAULTY
DIRECT TRIP SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
NO VOLTAGE IN LINE
A/R BLOCK
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
DIRECT TRIP SEND CHANNEL-1
GOOSE RECEIPT FAIL/TROUBLE
MAIN-2 RELAY FAIL
89L OPEN FOR STUB
DIRECT TRIP RECEIVED CHANNEL-1
LBB OPERATED
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
EMERGENCY/MANUAL CLOSE
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER FAULTY
SOTF PICKUP
SOTF TRIP( OC)
SOTF TRIP( IMPEDANCE Z1B)
CARRIER SEND CHANNEL-1
CARRIER SEND CHANNEL-2
DIRECT TRIP RECEIVED CHANNEL-2
CARRIER RECEIVED
CARRIER ADDIED TRIP/Z COM. TRIP
MAIN A/R OPTD
TIE A/R OPTD
CB MANUAL CLOSE
CB MANUAL TRIP
86 GROUP-A OPTD
86 GROUP-B OPTD
MAIN A/R START
TIE A/R START
DISTANCE ZONE-1 PICKUP
DISTANCE PROTN ZONE-1 TRIP
DISTANCE PROTN ZONE-1 R-PH TRIP
DISTANCE PROTN ZONE-1 Y-PH TRIP
DISTANCE PROTN ZONE-1 B-PH TRIP
DISTANCE ZONE-2 PICKUP
DISTANCE PROTN ZONE-2 TRIP
DISTANCE PROTN ZONE-2 R-PH TRIP
DISTANCE PROTN ZONE-2 Y-PH TRIP
DISTANCE PROTN ZONE-2 B-PH TRIP
DISTANCE ZONE-3 PICKUP
DISTANCE PROTN ZONE-3 TRIP
DISTANCE ZONE-4 PICKUP
DISTANCE PROTN ZONE-4 TRIP
DISTANCE PROTN ZONE-4 R-PH TRIP
DISTANCE PROTN ZONE-4 Y-PH TRIP
DISTANCE PROTN ZONE-4 B-PH TRIP
DISTANCE PROTN ZONE-1B PICKUP
DISTANCE PROTN ZONE-1B TRIP
DISTANCE PROTN ZONE-1B B-PH TRIP
DISTANCE PROTN ZONE-1B R-PH TRIP
DISTANCE PROTN ZONE-1B Y-PH TRIP
DISTANCE PROTN ZONE-5 PICKUP
STUB PICKUP
STUB OPERATED
DEF FAULT PICKUP
DEF FAULT TRIP
OVERVOLTAGE STAGE-1-PH-N PICKUP
OVERVOLTAGE STAGE-1 -PH-N TRIP
OVERVOLTAGE STAGE-2-PH-N PICKUP
OVERVOLTAGE STAGE-2-PH-N TRIP
OVERVOLTAGE STAGE-1-PH-PH PICKUP
OVERVOLTAGE STAGE-1-PH-PH TRIP
OVERVOLTAGE STAGE-2-PH-PH PICKUP
OVERVOLTAGE STAGE-2-PH-PH TRIP
POWER SWING ZONE-1 DETECTED
POWER SWING ZONE-1 BLOCK
POWER SWING ZONE-1B DETECTED
POWER SWING ZONE-1B BLOCK
POWER SWING ZONE-2 DETECTED
POWER SWING ZONE-2 BLOCK
POWER SWING ZONE-3 DETECTED
POWER SWING ZONE-3 BLOCK
POWER SWING ZONE-4 DETECTED
POWER SWING ZONE-4 BLOCK
BUSBAR PROTN OPTD
RELAY LED RESET
MAIN BCU FAIL
TIE BCU FAIL
MANUAL DR TRIGGER
GENERAL TRIP
DEVICE HEALTHY
MAIN-2 PROTN OPTD
STUB BLOCKED
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
MCU-2 UNHEALTHY
BREAKER FAILURE TRANSFER TRIP
TIME SYNCHRONISATION ERROR
BUSBAR TRIP
BAY UNIT-01 FAILURE
BAY UNIT-02 FAILURE
BAY UNIT-03 FAILURE
BAY UNIT-03 FAILURE
BAY UNIT-05 FAILURE
BAY UNIT-06 FAILURE
BAY UNIT-07 FAILURE
BAY UNIT-08 FAILURE
BUS-1 PROTECTION BLOCKED BY HANDLE
BUS-2 PROTECTION BLOCKED BY HANDLE
BUS-1 PROTECTION BLOCKED BY INTERM STATE
BUS-2 PROTECTION BLOCKED BY INTERM STATE
CURRENT SUPERVISION BUS-1
CURRENT SUPERVISION BUS-2
Trip command BF for BUS-1 R-PH
Trip command BF for BUS-1 Y-PH
Trip command BF for BUS-1 B-PH
Trip command BF for BUS-2 R-PH
Trip command BF for BUS-2 Y-PH
Trip command BF for BUS-2 B-PH
3-PH Trip command BF for BUS-1
3-PH Trip command BF for BUS-2
LBB RETRIP
LBB TRIP
GENERAL TRIP
GENERAL TRIP R-PH
GENERAL TRIP Y-PH
GENERAL TRIP B-PH
DEVICE OK
BAY UNIT-01 OUT OF SERVICE
BAY UNIT-02 OUT OF SERVICE
BAY UNIT-03 OUT OF SERVICE
BAY UNIT-04 OUT OF SERVICE
BAY UNIT-05 OUT OF SERVICE
BAY UNIT-06 OUT OF SERVICE
BAY UNIT-07 OUT OF SERVICE
BAY UNIT-08 OUT OF SERVICE
Trip repeat Bay Unit-01 R-PH
Trip repeat Bay Unit-01 Y-PH
Trip repeat Bay Unit-01 B-PH
Trip repeat Bay Unit-02 R-PH
Trip repeat Bay Unit-02 Y-PH
Trip repeat Bay Unit-02 B-PH
Trip repeat Bay Unit-03 R-PH
Trip repeat Bay Unit-03 Y-PH
Trip repeat Bay Unit-03 B-PH
Trip repeat Bay Unit-04 R-PH
Trip repeat Bay Unit-04 Y-PH
Trip repeat Bay Unit-04 B-PH
Trip repeat Bay Unit-05 R-PH
Trip repeat Bay Unit-05 Y-PH
Trip repeat Bay Unit-05 B-PH
Trip repeat Bay Unit-06 R-PH
Trip repeat Bay Unit-06 Y-PH
Trip repeat Bay Unit-06 B-PH
Trip repeat Bay Unit-07 R-PH
Trip repeat Bay Unit-07 Y-PH
Trip repeat Bay Unit-07 B-PH
Trip repeat Bay Unit-08 R-PH
Trip repeat Bay Unit-08 Y-PH
Trip repeat Bay Unit-08 B-PH
Transfer Trip BUS-1
Transfer Trip BUS-2
BUS ZONE 1 TRIP
BUS ZONE 2 TRIP
BUSBAR CHECKZONE ALARM
BUSBAR CHECKZONE TRIP
BREAKER FAILURE - BUSBAR 1 BLOCKED
BREAKER FAILURE - BUSBAR 2 BLOCKED
ISOLATOR IN INTERMEDIATE STATUS
BAY N TRIP
BUSBAR BLOCKED DUE TO COMMUNICATION ERROR_Bay_n
BAY_N_BREAKER FAILURE R-PH INITIATION
BAY_N_BREAKER FAILURE Y-PH INITIATION
BAY_N_BREAKER FAILURE B-PH INITIATION
BAY_N_BREAKER FAILURE 3PH INITIATION
BAY_N_EXTERNAL BUSBAR ZONE n
BAY_N_BREAKER FAILURE RETRIP
BAY_N_BREAKER FAILURE BACKTRIP
BAY_N_BREAKER FAILURE RPH- RETRIP
BAY_N_BREAKER FAILURE YPH- RETRIP
BAY_N_BREAKER FAILURE BPH- RETRIP
BBP CENTRAL UNIT IED UNHEALTHY
SETTING CHANGE
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
MCU-1 UNHEALTHY
BREAKER FAILURE TRANSFER TRIP
TIME SYNCHRONISATION ERROR
BUSBAR TRIP
BAY UNIT-01 FAILURE
BAY UNIT-02 FAILURE
BAY UNIT-03 FAILURE
BAY UNIT-04 FAILURE
BAY UNIT-05 FAILURE
BAY UNIT-06 FAILURE
BAY UNIT-07 FAILURE
BAY UNIT-08 FAILURE
BUS-1 PROTECTION BLOCKED BY HANDLE
BUS-2 PROTECTION BLOCKED BY HANDLE
BUS-1 PROTECTION BLOCKED BY INTERM STATE
BUS-2 PROTECTION BLOCKED BY INTERM STATE
CURRENT SUPERVISION BUS-1
CURRENT SUPERVISION BUS-2
Trip command BF for BUS-1 R-PH
Trip command BF for BUS-1 Y-PH
Trip command BF for BUS-1 B-PH
Trip command BF for BUS-2 R-PH
Trip command BF for BUS-2 Y-PH
Trip command BF for BUS-2 B-PH
3-PH Trip command BF for BUS-1
3-PH Trip command BF for BUS-2
LBB RETRIP
LBB TRIP
GENERAL TRIP
GENERAL TRIP R-PH
GENERAL TRIP Y-PH
GENERAL TRIP B-PH
DEVICE OK
BAY UNIT-01 OUT OF SERVICE
BAY UNIT-02 OUT OF SERVICE
BAY UNIT-03 OUT OF SERVICE
BAY UNIT-04 OUT OF SERVICE
BAY UNIT-05 OUT OF SERVICE
BAY UNIT-06 OUT OF SERVICE
BAY UNIT-07 OUT OF SERVICE
BAY UNIT-08 OUT OF SERVICE
Trip repeat Bay Unit-01 R-PH
Trip repeat Bay Unit-01 Y-PH
Trip repeat Bay Unit-01 B-PH
Trip repeat Bay Unit-02 R-PH
Trip repeat Bay Unit-02 Y-PH
Trip repeat Bay Unit-02 B-PH
Trip repeat Bay Unit-03 R-PH
Trip repeat Bay Unit-03 Y-PH
Trip repeat Bay Unit-03 B-PH
Trip repeat Bay Unit-04 R-PH
Trip repeat Bay Unit-04 Y-PH
Trip repeat Bay Unit-04 B-PH
Trip repeat Bay Unit-05 R-PH
Trip repeat Bay Unit-05 Y-PH
Trip repeat Bay Unit-05 B-PH
Trip repeat Bay Unit-06 R-PH
Trip repeat Bay Unit-06 Y-PH
Trip repeat Bay Unit-06 B-PH
Trip repeat Bay Unit-07 R-PH
Trip repeat Bay Unit-07 Y-PH
Trip repeat Bay Unit-07 B-PH
Trip repeat Bay Unit-08 R-PH
Trip repeat Bay Unit-08 Y-PH
Trip repeat Bay Unit-08 B-PH
Transfer Trip BUS-1
Transfer Trip BUS-2
BUS ZONE 1 TRIP
BUS ZONE 2 TRIP
BUSBAR CHECKZONE ALARM
BUSBAR CHECKZONE TRIP
BREAKER FAILURE - BUSBAR 1 BLOCKED
BREAKER FAILURE - BUSBAR 2 BLOCKED
ISOLATOR IN INTERMEDIATE STATUS
BAY N TRIP
BUSBAR BLOCKED DUE TO COMMUNICATION ERROR_Bay_n
BAY_N_BREAKER FAILURE R-PH INITIATION
BAY_N_BREAKER FAILURE Y-PH INITIATION
BAY_N_BREAKER FAILURE B-PH INITIATION
BAY_N_BREAKER FAILURE 3PH INITIATION
BAY_N_EXTERNAL BUSBAR ZONE n
BAY_N_BREAKER FAILURE RETRIP
BAY_N_BREAKER FAILURE BACKTRIP
BAY_N_BREAKER FAILURE RPH- RETRIP
BAY_N_BREAKER FAILURE YPH- RETRIP
BAY_N_BREAKER FAILURE BPH- RETRIP
BBP CENTRAL UNIT IED UNHEALTHY
SETTING CHANGE
RELAY IN TEST MODE
IED MODEL
Voltage Level
CB Y-PH POSITION
CB B-PH POSITION
CB POSITION
89AE POSITION
89BE POSITION
89A POSITION
89B POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
CB DC SUPPLY-1/2 FAIL
CB SPRING NOT CHARGED B-PH
CB SPRING NOT CHARGED R-PH
CB SPRING NOT CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
MAIN DC-1 SUPPLY Fail
89A POLE DESCREPENCY
89B POLE DESCREPENCY
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
KIOSK AC 1_2 Power Fail
KIOSK AC 1_2 ON STATUS
DC SOURCE-2 FAIL
KIOSK HEAT DETECTED
KIOSK SMOKE DETECTED
EMERGENCY/MANUAL CB TRIP
PSD DEVICE HEALTHY
PSD DEVICE IN SERVICE
PSD SENSSOR ERROR/CB VOLTAGE ERROR
PSD BYPASS
PSD SYNCH OPERATION FAIL/DEFECTIVE SYNC DATA ALARM
SYNC OPERATION FAIL
TIE LBB RELAY UNHEALTHY
TIE LBB OPTD
CB POLE DESCREPENCY
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB READY
EMERGENCY/MANUAL CB TRIP
CB MANUAL CLOSE
CB CONTROL NO SYNC
CB CLOSE INTERLOCK
89AE OPEN INTERLOCK
89BE OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
A/R READY
A/R UNSUCCESSFUL
A/R START
A/R SUCCESSFUL
RECLAIM IN PROGRESS
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
Tie CB A/R PRIORITY CLOSE
MAIN/TIE BCU HEALTHY
AR SINGLE PHASE TRIP PERMITTED
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
RELAY IN TEST MODE
SETTINGS CHANGED
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
MEASUREMENT
POWER FACTOR
FREQUENCY
REACTIVE POWER
APPARENT POWER
I-R -PH CURRENT
I-Y -PH CURRENT
I-B -PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
KIOSK TEMPERATURE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
COMMANDS
89B CONTROL
89A CONTROL
89BE CONTROL
89AE CONTROL
CB CONTROL
89B CONTROL NO LOCK
89A CONTROL NO LOCK
89BE CONTROL NO LOCK
89AE CONTROL NO LOCK
CB CONTROL NO SYNC
CB CONTROL NO LOCK
86B TRIP RELAY RESET COMMAND
86A TRIP RELAY RESET COMMAND
BAY BLOCK
TELECONTROL BLOCK
GOOSE RECEIPT FAIL/TROUBLE
A/R ON CONTROL
A/R OFF CONTROL
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
CB READY FOR A/R
A/R UNSUCCESSFUL
A/R SUCCESSFUL
CB NOT READY
A/R CLOSE COMMAND INDICATION
TIE A/R START
A/R IN PROGRESS
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
BREAKER FAILURE YPH- RETRIP
BREAKER FAILURE BPH- RETRIP
BREAKER FAILURE BACKTRIP
BREAKER FAILURE TRIP EXTERNAL
GENERAL TRIP
BREAKER FAILURE INITIATION 3-PH
TIE CB FAIL
TIE BCU UNHEALTHY
DEVICE HEALTHY
LBB EXTERNAL INITIATION 3-PH
TIME SYNCHRONISATION ERROR
LBB EXTERNAL INITIATION R-PH
LBB EXTERNAL INITIATION Y-PH
LBB EXTERNAL INITIATION B-PH
POLE DISCREPANCY PICKUP
POLE DISCREPANCY TRIP
LBB ACTIVE
DC-1 Fail
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB Y-PH POSITION
CB B-PH POSITION
CB POSITION
89AE1 POSITION
89AE2 POSITION
89BE1 POSITION
89BE2 POSITION
89RE-B POSITION
89RE-R POSITION
89RE-Y POSITION
89A POSITION
89B POSITION
89R-B POSITION
89R-R POSITION
89R-Y POSITION
S89RE2 POSITION
S89R-R POSITION
S89R-Y POSITION
S89R-B POSITION
BINARY INPUT (Single Point)
BCU IN LOCAL/REMOTE
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB SF6 GAS PRESSURE LOCKOUT
89A POLE DESCREPENCY
89B POLE DESCREPENCY
CB DC SUPPLY-1/2 FAIL
CB SPRING CHARGED
CB SF6 GAS PRESSURE LOCKOUT
EMERGENCY/MANUAL CB TRIP
MAIN TANK HIGH LEVEL ALARM B-PH
MAIN TANK HIGH LEVEL ALARM R-PH
MAIN TANK HIGH LEVEL ALARM Y-PH
MAIN TANK LOW LEVEL ALARM B-PH
MAIN TANK LOW LEVEL ALARM R-PH
OTI ALARM B-PH
OTI ALARM R-PH
OTI ALARM Y-PH
PSD DEVICE HEALTHY
PSD DEVICE IN SERVICE
PSD ALARM
PSD SYNCH DATA ERROR
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
WTI ALARM B-PH
WTI ALARM R-PH
WTI ALARM Y-PH
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
CB POLE DISCREPANCY
CB SF6 GAS PRESSURE REFILL LOW ALARM
BUS-1 VT RESET
BUS-2 VT RESET
LINE VT RESET
CB READY
CB POSITION NO SYNC
DEVICE HEALTHY
S89RE2 OPEN INTERLOCK
64R.2R RELAY FAIL
64R.2Y RELAY FAIL
64R.2B RELAY FAIL
64R.2S relay Unhealthy
87R.1 relay Unhealthy
21R.1 relay Unhealthy
Manual close
CB CLOSE INTERLOCK
89AE1 OPEN INTERLOCK
89BE1 OPEN INTERLOCK
89BE2 OPEN INTERLOCK
89RE-B-PH OPEN INTERLOCK
89RE-R-PH OPEN INTERLOCK
89RE-Y-PH OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89R-B-PH OPEN INTERLOCK
89R-R-PH OPEN INTERLOCK
89R-Y-PH OPEN INTERLOCK
RELAY IN TEST MODE
SETTINGS CHANGED
REACTOR-n R PH OUT OF SERVICE
REACTOR-n Y PH OUT OF SERVICE
REACTOR-n B PH OUT OF SERVICE
REACTOR SPARE PH IN SERVICE IN REACTOR-N
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
GOOSE RECEIPT FAIL/TROUBLE
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
COMMANDS
89R-Y CONTROL
89R-R CONTROL
89R-B CONTROL
89B CONTROL
89A CONTROL
89RE-Y CONTROL
89RE-R CONTROL
89RE-B CONTROL
89BE2 CONTROL
89BE1 CONTROL
89AE2 CONTROL
89AE1 CONTROL
CB CONTROL
CB CONTROL NO SYNC
86B TRIP RELAY RESET COMMAND
86A TRIP RELAY RESET COMMAND
Voltage Level
INFORMATION TYPE
TIE CB OPEN
GOOSE RECEIPT FAIL/TROUBLE
OTI TRIP R-PH
WTI TRIP R-PH
PRV-1, 2 & 3 TRIP R-PH
TIME SYNCHRONISATION ERROR
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
MAIN TANK BUCHHOLZ-1&2 ALARM R-PH
DEVICE HEALTHY
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
87R RELAY UNHEALTHY
BCU UNHEALTHY
GOOSE RECEIPT FAIL/TROUBLE
OTI TRIP Y-PH
PRV-1, 2 & 3 TRIP Y-PH
TIME SYNCHRONISATION ERROR
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
MAIN TANK BUCHHOLZ-1&2 ALARM Y-PH
DEVICE HEALTHY
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
TIME SYNCHRONISATION ERROR
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
OTI TRIP B-PH
PRV-1,2 & 3 TRIP B-PH
DEVICE HEALTHY
MAIN TANK BUCHHOLZ-1&2 ALARM B-PH
MAIN TANK BUCHHOLZ-1&2 TRIP SP-PH
NGR THERMAL OVERLOAD TRIP
87R RELAY UNHEALTHY
GENERAL PICKUP
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
OTI TRIP SP-PH
MAIN TANK BUCHHOLZ-1&2 ALARM SP-PH
PRV-1, 2 & 3 TRIP SP-PH
TIME SYNCHRONISATION ERROR
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
WTI TRIP B-PH
WTI TRIP Y-PH
64.2-R_Y_B SP RELAY UNHEALTHY
TIME SYNCHRONISATION ERROR
BACKUP IMPEDENCE ZONE-1 START
BACKUP IMPEDENCE ZONE-1 TRIP
BACKUP IMPEDENCE R-PH TRIP
BACKUP IMPEDENCE Y-PH TRIP
BACKUP IMPEDENCE B-PH TRIP
BACKUP IMPEDENCE BLOCKED
GENERAL TRIP
NON-DIRECTIONAL OVERCURRENT TRIP
NON-DIRECTIONAL OVERCURRENT START
DEVICE HEALTHY
NO VOLTAGE IN LINE
VT FUSE FAILURE
SETTINGS CHANGED
RELAY IN TEST MODE
NON-DIRECTIONAL EARTHFAULT TRIP
NON-DIRECTIONAL EARTHFAULT START
Voltage Level
INFORMATION TYPE
GOOSE RECEIPT FAIL/TROUBLE
MAIN TANK BUCHHOLZ-1 TRIP B-PH
MAIN TANK BUCHHOLZ-1 TRIP R-PH
MAIN TANK BUCHHOLZ-1TRIP Y-PH
REACTOR CB OPEN
WTI R-PH TRIP
WTI Y-PH TRIP
WTI B-PH TRIP
PRESSURE RELIF VALVE-2 TRIP R-PH
PRESSURE RELIF VALVE-2 TRIP Y-PH
PRESSURE RELIF VALVE-2 TRIP B-PH
BUCHHOLZ-1 SP PH TRIP
WTI SP PH TRIP
PRESSURE RELIF VALVE-2 SP PH TRIP
TIME SYNCHRONISATION ERROR
DIFFERENTIAL TRIP R-PH
DIFFERENTIAL TRIP Y-PH
DIFFERENTIAL TRIP B-PH
DIFFERENTIAL STAGE 1 TRIP
DIFFERENTIAL STAGE 1 PICKUP
DIFFERENTIAL STAGE 2 TRIP
DIFFERENTIAL STAGE 2 PICKUP
21R RELAY UNHEALTHY
GENERAL TRIP
DEVICE HEALTHY
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
S89T-R POSITION
S89T-Y POSITION
S89T-B POSITION
89AE POSITION
89BE POSITION
89TE B-PH POSITION
89TE R-PH POSITION
89TE Y-PH POSITION
89STE B-PH POSITION
89STE R-PH POSITION
89STE Y-PH POSITION
89STE POSITION
89A POSITION
89B POSITION
89T B-PH POSITION
89T R-PH POSITION
89T Y-PH POSITION
89TS1_TS2 B-PH POSITION
89TS1_TS2 R-PH POSITION
89TS1_TS2 Y-PH POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
LED RESET
BCU MODE
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB SF6 GAS PRESSURE LOCKOUT
CB DC SUPPLY-1/2 FAIL
CB SF6 GAS PRESSURE LOCKOUT
POLE DESCREPENCY
CB SPRING CHARGED B-PH
CB SPRING CHARGED R-PH
CB SPRING CHARGED Y-PH
89A POLE DESCREPENCY
89B POLE DESCREPENCY
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
EMERGENCY/MANUAL TRIP
CB TC-1 FAULTY
CB TC-2 FAULTY
PSD DEVICE IN SERVICE
PSD DEVICE HEALTHY
PSD ALARM
PSD SYNCH DATA ERROR
DGA GAS HIGH ALARM SP-PH
DGA GAS HIGH ALARM R_Y_B-PH
MOISTER HIGH ALARM R_Y_B-PH
MOISTER HIGH ALARM SP-PH
OLTC OIL TEMP HIGH B-PH ALARM
OLTC OIL TEMP HIGH R-PH ALARM
OLTC OIL TEMP HIGH SP-PH ALARM
OLTC OIL TEMP HIGH Y-PH ALARM
OLTC OIL TEMP LOW B-PH ALARM
OLTC OIL TEMP LOW R-PH ALARM
OLTC OIL TEMP LOW SP-PH ALARM
OLTC OIL TEMP LOW Y-PH ALARM
OLTC LOW OIL REFILL B-PH ALARM
OLTC LOW OIL REFILL SP-PH ALARM
OLTC LOW OIL REFILL R-PH ALARM
OLTC LOW OIL REFILL Y-PH ALARM
RPH MOG LOW OIL LEVEL ALARM
YPH MOG LOW OIL LEVEL ALARM
BPH MOG LOW OIL LEVEL ALARM
SP-PH MOG LOW OIL LEVEL ALARM
RPH MOG HIGH OIL LEVEL ALARM
YPH MOG HIGH OIL LEVEL ALARM
BPH MOG HIGH OIL LEVEL ALARM
SP-PH MOG HIGH OIL LEVEL ALARM
R-PH OIL FLOW SENSITIVE VALVE ALARM
Y-PH OIL FLOW SENSITIVE VALVE ALARM
B-PH OIL FLOW SENSITIVE VALVE ALARM
SP-PH OIL FLOW SENSITIVE VALVE ALARM
RPH PUMP FAIL - BANK A
RPH PUMP FAIL - BANK B
RPH PUMP FAIL - BANK C
RPH PUMP FAIL - BANK D
YPH PUMP FAIL - BANK A
YPH PUMP FAIL - BANK B
YPH PUMP FAIL - BANK C
YPH PUMP FAIL - BANK D
BPH PUMP FAIL - BANK A
BPH PUMP FAIL - BANK B
BPH PUMP FAIL - BANK C
BPH PUMP FAIL - BANK D
SPH PUMP FAIL - BANK A
SPH PUMP FAIL - BANK B
SPH PUMP FAIL - BANK C
SPH PUMP FAIL - BANK D
RPH THERMAL OVERLOAD TRIP - BANK A
RPH THERMAL OVERLOAD TRIP - BANK B
RPH THERMAL OVERLOAD TRIP - BANK C
RPH THERMAL OVERLOAD TRIP - BANK D
YPH THERMAL OVERLOAD TRIP - BANK A
YPH THERMAL OVERLOAD TRIP - BANK B
YPH THERMAL OVERLOAD TRIP - BANK C
YPH THERMAL OVERLOAD TRIP - BANK D
BPH THERMAL OVERLOAD TRIP - BANK A
BPH THERMAL OVERLOAD TRIP - BANK B
BPH THERMAL OVERLOAD TRIP - BANK C
BPH THERMAL OVERLOAD TRIP - BANK D
SPH THERMAL OVERLOAD TRIP - BANK A
SPH THERMAL OVERLOAD TRIP - BANK B
SPH THERMAL OVERLOAD TRIP - BANK C
SPH THERMAL OVERLOAD TRIP - BANK D
RPH LOW OIL FLOW/REVERSE FLOW - BANK A
RPH LOW OIL FLOW/REVERSE FLOW - BANK B
RPH LOW OIL FLOW/REVERSE FLOW - BANK C
RPH LOW OIL FLOW/REVERSE FLOW - BANK D
YPH LOW OIL FLOW/REVERSE FLOW - BANK A
YPH LOW OIL FLOW/REVERSE FLOW - BANK B
YPH LOW OIL FLOW/REVERSE FLOW - BANK C
YPH LOW OIL FLOW/REVERSE FLOW - BANK D
BPH LOW OIL FLOW/REVERSE FLOW - BANK A
BPH LOW OIL FLOW/REVERSE FLOW - BANK B
BPH LOW OIL FLOW/REVERSE FLOW - BANK C
BPH LOW OIL FLOW/REVERSE FLOW - BANK D
SPH LOW OIL FLOW/REVERSE FLOW - BANK A
SPH LOW OIL FLOW/REVERSE FLOW - BANK B
SPH LOW OIL FLOW/REVERSE FLOW - BANK C
SPH LOW OIL FLOW/REVERSE FLOW - BANK D
RPH COOLER CONTROL SUPPLY FAIL
YPH COOLER CONTROL SUPPLY FAIL
BPH COOLER CONTROL SUPPLY FAIL
SPH COOLER CONTROL SUPPLY FAIL
RPH SUPPLY CHANGE OVER FAIL
YPH SUPPLY CHANGE OVER FAIL
BPH SUPPLY CHANGE OVER FAIL
SPH SUPPLY CHANGE OVER FAIL
RPH SUPPLY - A FAIL
YPH SUPPLY - A FAIL
BPH SUPPLY - A FAIL
SPH SUPPLY - A FAIL
RPH SUPPLY - B FAIL
YPH SUPPLY - B FAIL
BPH SUPPLY - B FAIL
SPH SUPPLY - B FAIL
RPH OLTC MOTOR OVERLOAD
RPH TAP CHANGE IN PROGRESS
RPH TAP CHANGE IN COMPLETE
RPH OLTC IN LOCAL
RPH OLTC IN REMOTE
RPH TAP CHANGE CONTROL SUPPLY FAIL
RPH LOWEST POSITION REACHDED
RPH HIGHESHT POSITION REACHDED
RPH OLTC RAISE COMMAND
RPH OLTC LOWER COMMAND
YPH OLTC MOTOR OVERLOAD
YPH TAP CHANGE IN PROGRESS
YPH TAP CHANGE IN COMPLETE
YPH OLTC IN LOCAL
YPH OLTC IN REMOTE
YPH TAP CHANGE CONTROL SUPPLY FAIL
YPH LOWEST POSITION REACHDED
YPH HIGHESHT POSITION REACHDED
YPH OLTC RAISE COMMAND
YPH OLTC LOWER COMMAND
BPH OLTC MOTOR OVERLOAD
BPH TAP CHANGE IN PROGRESS
BPH TAP CHANGE IN COMPLETE
BPH OLTC IN LOCAL
BPH OLTC IN REMOTE
BPH TAP CHANGE CONTROL SUPPLY FAIL
BPH LOWEST POSITION REACHDED
BPH HIGHESHT POSITION REACHDED
BPH OLTC RAISE COMMAND
BPH OLTC LOWER COMMAND
SPH OLTC MOTOR OVERLOAD
SPH TAP CHANGE IN PROGRESS
SPH TAP CHANGE IN COMPLETE
SPH OLTC IN LOCAL
SPH OLTC IN REMOTE
SPH TAP CHANGE CONTROL SUPPLY FAIL
SPH LOWEST POSITION REACHDED
SPH HIGHESHT POSITION REACHDED
SPH OLTC RAISE COMMAND
SPH OLTC LOWER COMMAND
OTI B-PH ALARM
OTI R-PH ALARM
OTI SP-PH ALARM
OTI Y-PH ALARM
PUMP FAIL B-PH
PUMP FAIL R-PH
PUMP FAIL SP-PH
PUMP FAIL Y-PH
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
WTI HV_IV_LV ALARM B-PH
WTI HV_IV_LV ALARM R-PH
WTI HV_IV_LV ALARM SP-PH
WTI HV_IV_LV ALARM Y-PH
CB SF6 LOW PRESSURE ALARM B-PH
CB SF6 LOW PRESSURE ALARM R-PH
CB SF6 LOW PRESSURE ALARM Y-PH
BUS-1 VT RESET
BUS-2 VT RESET
LINE VT RESET
CB READY
EMERGENCY/MANUAL CB CLOSE
GOOSE RECEIPT FAIL/TROUBLE
CB POSITION NO SYNC
CB CLOSE INTERLOCK
89AE1 OPEN INTERLOCK
89AE2 OPEN INTERLOCK
89BE OPEN INTERLOCK
89TE B-PH OPEN INTERLOCK
89TE R-PH OPEN INTERLOCK
89TE Y-PH OPEN INTERLOCK
TSE1 B-PH OPEN INTERLOCK
TSE1 R-PH OPEN INTERLOCK
TSE1 Y-PH OPEN INTERLOCK
TSE2 OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89T B-PH OPEN INTERLOCK
89T R-PH OPEN INTERLOCK
89T Y-PH OPEN INTERLOCK
89TS1_TS2 B-PH OPEN INTERLOCK
89TS1_TS2 R-PH OPEN INTERLOCK
89TS1_TS2 Y-PH OPEN INTERLOCK
RELAY IN TEST MODE
SETTINGS CHANGED
ICT-n R PH OUT OF SERVICE
ICT-n Y PH OUT OF SERVICE
ICT-n B PH OUT OF SERVICE
ICT SPARE PH IN SERVICE IN ICT-N
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
COMMANDS
CB CONTROL
89AE1 CONTROL
89AE2 CONTROL
89BE CONTROL
89TE B-PH CONTROL
89TE R-PH CONTROL
89TE Y-PH CONTROL
TSE1 B-PH CONTROL
TSE1 R-PH CONTROL
TSE1 Y-PH CONTROL
TSE2 CONTROL
89A CONTROL
89B CONTROL
89T B-PH CONTROL
89T R-PH CONTROL
89TS1_TS2 B-PH CONTROL
89TS1_TS2 R-PH CONTROL
89TS1_TS2 Y-PH CONTROL
89T Y-PH CONTROL
CB CONTROL NO SYN
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
TAP RAISER
TAP LOWER
Voltage Level
INFORMATION TYPE
DMT EARTHFAULT STAGE 1 PICKUP
DMT EARTHFAULT STAGE 2 TRIP
DMT EARTHFAULT STAGE 2 PICKUP
IDMT EARTHFAULT TRIP
IDMT EARTHFAULT PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
OLTC OSR TRIP R PH
OLTC OSR TRIP Y PH
OLTC OSR TRIP B PH
OIL FLOW SENSITIVE VALVE TRIP R PH
OIL FLOW SENSITIVE VALVE TRIP Y PH
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
RAPID PRESSURE TRIP B-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
BUCHHOLZ 1 TRIP B-PH
OTI TRIP B-PH
BUCHHOLZ 2 ALARM B-PH
PRD OLTC TRIP B-PH
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
TIE CB OPEN
BUCHHOLZ 1 TRIP R-PH
BUCHHOLZ 2 ALARM R-PH
OTI TRIP R-PH
PRD OLTC TRIP R-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
OTI TRIP SP-PH
OLTC OSR TRIP SP PH
BUCHHOLZ 2 ALARM SP-PH
PRD OLTC TRIP SP-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
OTI TRIP Y-PH
PRD OLTC TRIP Y-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
BUCHHOLZ 2 ALARM Y-PH
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
87.1_99HV HV RELAY UNHEALTHY
BCU UNHEALTHY
DIRECTIONAL DMT OVERCURRENT STAGE-1 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-1 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-1 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-2 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-2 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-2 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-3 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-3 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-1 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-1 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-1 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-2 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-2 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-2 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-3 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-3 PICKUP
DIRECTIONAL IDMT OVERCURRENT BLOCKED
DIRECTIONAL IDMT OVERCURRENT TRIP
DIRECTIONAL IDMT EARTHFAULT BLOCKED
DIRECTIONAL IDMT EARTHFAULT TRIP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
BUCHHOLZ 2 TRIP SP-PH
WTI HV_IV_LV TRIP SP-PH
WTI HV_LV_IV TRIP B-PH
WTI HV_LV_IV TRIP R-PH
WTI HV_LV_IV TRIP Y-PH
DIRECTIONAL DMT OVERCURRENT STAGE-1 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-1 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-1 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-2 BLOCKED
DIRECTIONAL DMT OVERCURRENT STAGE-2 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-2 PICKUP
DIRECTIONAL DMT OVERCURRENT STAGE-3 TRIP
DIRECTIONAL DMT OVERCURRENT STAGE-3 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-1 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-1 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-1 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-2 BLOCKED
DIRECTIONAL DMT EARTHFAULT STAGE-2 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-2 PICKUP
DIRECTIONAL DMT EARTHFAULT STAGE-3 TRIP
DIRECTIONAL DMT EARTHFAULT STAGE-3 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
67.1 LV RELAY UNHEALTHY
RAPID PRESSURE TRIP Y-PH
OIL FLOW SENSITIVE VALVE TRIP B PH
OIL FLOW SENSITIVE VALVE TRIP SP PH
OVERFLUX STAGE-2 OPERATED
OVERFLUX STAGE-2 PICKUP
OVERFLUX STAGE-1 OPERATED
OVERFLUX STAGE-1 PICKUP
GENERAL TRIP
GENERAL PICKUP
DEVICE HEALTHY
TIME SYNCHRONISATION ERROR
OVERFLUX ALARM
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
MAIN CB OPEN
MAIN CB CLOSE
REF PROTECTION OPERATED
86 A/86 B RELAY OPERATED
BUCHHOLZ 2 TRIP R-PH
BUCHHOLZ 2 TRIP Y-PH
BUCHHOLZ 2 TRIP B-PH
BUCHHOLZ 1 ALARM R-PH
BUCHHOLZ 1 ALARM Y-PH
BUCHHOLZ 1ALARM B-PH
BUCHHOLZ 1 ALARM SP-PH
TIE CB OPEN
PRD1, 2 & 3 TRIP SP-PH
PRD1, 2 & 3 TRIP R-PH
PRD1, 2 & 3 TRIP Y-PH
PRD1, 2 & 3 TRIP B-PH
2nd HARMONIC BLOCK PH-R
2nd HARMONIC BLOCK PH-Y
2nd HARMONIC BLOCK PH-B
5th HARMONIC BLOCK PH-R
5th HARMONIC BLOCK PH-Y
5th HARMONIC BLOCK PH-B
DIFFERENTIAL TRIP
DIFFERENTIAL TRIP R-PH
DIFFERENTIAL TRIP Y-PH
DIFFERENTIAL TRIP B-PH
DIFFERENTIAL STAGE-1 TRIP
DIFFERENTIAL STAGE-1 PICKUP
DIFFERENTIAL STAGE-2 TRIP
DIFFERENTIAL STAGE-2 PICKUP
OVER FLUX TRIP
OVERFLUX STAGE-2 TRIP
OVERFLUX STAGE-1 TRIP
OVERFLUX HV ALARM
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
WTI TRIP B-PH
WTI TRIP Y-PH
64.2-R_Y_B SP RELAY UNHEALTHY
TIME SYNCHRONISATION ERROR
BACKUP IMPEDENCE ZONE-1 START
BACKUP IMPEDENCE ZONE-1 TRIP
BACKUP IMPEDENCE R-PH TRIP
BACKUP IMPEDENCE Y-PH TRIP
BACKUP IMPEDENCE B-PH TRIP
BACKUP IMPEDENCE BLOCKED
GENERAL TRIP
NON-DIRECTIONAL OVERCURRENT TRIP
NON-DIRECTIONAL OVERCURRENT START
DEVICE HEALTHY
NO VOLTAGE IN LINE
VT FUSE FAILURE
SETTINGS CHANGED
RELAY IN TEST MODE
NON-DIRECTIONAL EARTHFAULT TRIP
NON-DIRECTIONAL EARTHFAULT START
IED MODEL
Voltage Level
INFORMATION TYPE
CB Y-PH POSITION
CB B-PH POSITION
CB POSITION
89AE POSITION
89BE POSITION
89LRE1 POSITION
89RE-B POSITION
89RE-R POSITION
89RE-Y POSITION
89RSE1-B POSITION
89RSE1-R POSITION
89RSE1-Y POSITION
89A POSITION
89B POSITION
89LR POSITION
89R-B POSITION
89R-R POSITION
89R-Y POSITION
89RS1_RS2-B POSITION
89RS1_RS2-R POSITION
89RS1_RS2-Y POSITION
NGR CB POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
GOOSE RECEIPT FAIL/TROUBLE
BCU MODE
CB DC SUPPLY-1/2 FAIL
CB SPRING CHARGED B-PH
CB SPRING CHARGED R-PH
CB SPRING CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
A/R BLOCK MAIN1-1
A/R BLOCK MAIN-2
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
CARRIER CHANNEL-1 OUT
CARRIER CHANNEL-2 OUT
MAIN-2 RELAY UNHEALTHY
EMERGENCY/MANUAL CB TRIP
MAIN TANK HIGH LEVEL ALARM B-PH
MAIN TANK HIGH LEVEL ALARM R-PH
MAIN TANK HIGH LEVEL ALARM Y-PH
MAIN TANK LOW LEVEL ALARM B-PH
MAIN TANK LOW LEVEL ALARM R-PH
MAIN TANK LOW LEVEL ALARM Y-PH
OTI ALARM B-PH
OTI ALARM R-PH
OTI ALARM Y-PH
SPEECH CHANNEL FAIL
CB TC-1 FAULTY
CB TC-2 FAULTY
WTI ALARM B-PH
WTI ALARM R-PH
WTI ALARM Y-PH
CB POLE DESCREPENCY ALARM
CB SF6 GAS PRESSURE REFILL LOW ALARM
TIME SYNCHRONISATION ERROR
BUS-1 VT RESET
BUS-2 VT RESET
LINE VT RESET
EMERGENCY/MANUAL CB CLOSE
A/R FUNCTION ON
CB READY FOR A/R
A/R UNSUCCESSFUL
A/R SUCCESSFUL
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
A/R FUNCTION OFF
A/R FUNCTION ON
CB POSITION NO SYNC
89AE OPEN INTERLOCK
89BE OPEN INTERLOCK
89LE OPEN INTERLOCK
89RE-B-PH OPEN INTERLOCK
89RE-R-PH OPEN INTERLOCK
89RE-Y-PH OPEN INTERLOCK
89RSE1-B-PH OPEN INTERLOCK
89RSE1-R-PH OPEN INTERLOCK
89RSE1-Y-PH OPEN INTERLOCK
89A-PH OPEN INTERLOCK
89B-PH OPEN INTERLOCK
89L-PH OPEN INTERLOCK
89R-B-PH OPEN INTERLOCK
89R-R-PH OPEN INTERLOCK
89R-Y-PH OPEN INTERLOCK
89RS1_RS2-B-PH OPEN INTERLOCK
89RS1_RS2-R-PH OPEN INTERLOCK
89RS1_RS2-Y-PH OPEN INTERLOCK
NGR CB CLOSE INTERLOCK
RELAY IN TEST MODE
SETTINGS CHANGED
REACTOR-n R PH OUT OF SERVICE
REACTOR-n Y PH OUT OF SERVICE
REACTOR-n B PH OUT OF SERVICE
REACTOR SPARE PH IN SERVICE IN REACTOR-N
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
NGR CB TC-1 FAULTY
NGR CB TC-2 FAULTY
NGR CB DC FAULTY
NGR CB AC FAULTY
NGR CB SPRING NOT CHARGED
NGR CB SF6 GAS LOW
NGR CB SF6 CB TROUBLE ALARM
NGR MECHANICAL TRIPPING IF ASSIGNED
MEASUREMENTS
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
COMMANDS
CB CONTROL
89AE CONTROL
89BE CONTROL
89LE CONTROL
89RE-B CONTROL
89RE-R CONTROL
89RE-Y CONTROL
89RSE1-B CONTROL
89RSE1-R CONTROL
89RSE1-Y CONTROL
89A CONTROL
89B CONTROL
89L CONTROL
89R-B CONTROL
89R-R CONTROL
89R-Y CONTROL
89RS1_RS2-B CONTROL
89RS1_RS2-R CONTROL
89RS1_RS2-Y CONTROL
NGR CB CONTROL
CB CONTROL NO SYNC
NGR CB CONTROL NO SYNC
86B TRIP RELAY RESET COMMAND
86A TRIP RELAY RESET COMMAND
A/R ON CONTROL
A/R OFF CONTROL
Voltage Level
INFORMATION TYPE
WTI TRIP B-PH
WTI TRIP Y-PH
OTI TRIP B-PH
OTI TRIP R-PH
BUCHHOLZ-1/2 TRIP R-PH
BUCHHOLZ-1/2 TRIP Y-PH
BUCHHOLZ-1/2 TRIP B-PH
BACKUP IMPEDENCE ZONE-1 PICKUP
BACKUP IMPEDENCE ZONE-1 TRIP
BACKUP IMPEDENCE R-PH TRIP
BACKUP IMPEDENCE Y-PH TRIP
BACKUP IMPEDENCE B-PH TRIP
GENERAL TRIP
BACKUP IMPEDENCE BLOCKED
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
VOLTAGE ABSENT
VT FUSE FAILURE
TIME SYNCHRONISATION ERROR
BROKEN CONDUCTOR
NON-DIRECTIONAL OVERCURRENT TRIP
NON-DIRECTIONAL OVERCURRENT START
NON-DIRECTIONAL EARTHFAULT TRIP
NON-DIRECTIONAL EARTHFAULT START
SETTINGS CHANGED
RELAY IN TEST MODE
NGR CLOSE COMMAND BY E/F PICKUP(5 SEC)
NGR CLOSE COMMAND BY MECH TRIP
Voltage Level
INFORMATION TYPE
BUCHHOLZ TRIP R-PH
BUCHHOLZ TRIP Y-PH
OTI TRIP Y-PH
REF STAGE 1 TRIP
REF STAGE 1 PICKUP
REF STAGE 2 TRIP
REF STAGE 2 PICKUP
GENERAL TRIP
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
NGR THERMAL OVERLOAD TRIP
TIME SYNCHRONISATION ERROR
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
PRV-1 TRIP B-PH(NO)
PRV-1 TRIP R-PH(NO)
PRV-1 TRIP Y-PH(NO)
PRV-1 TRIP B-PH(NC)
PRV-1 TRIP R-PH(NC)
PRV-1 TRIP Y-PH(NC)
PRV-2 TRIP B-PH(NO)
PRV-2 TRIP R-PH(NO)
PRV-2 TRIP Y-PH(NO)
PRV-2 TRIP R-PH(NC)
PRV-2 TRIP Y-PH(NC)
PRV-1 TRIP B-PH
PRV-1 TRIP R-PH
PRV-1 TRIP Y-PH
PRV-2 TRIP B-PH
PRV-2 TRIP R-PH
PRV-2 TRIP Y-PH
WTI TRIP R-PH
DIFFERENTIAL TRIP R-PH
DIFFERENTIAL TRIP Y-PH
DIFFERENTIAL TRIP B-PH
DIFFERENTIAL STAGE 1 OPERATED
DIFFERENTIAL STAGE 1 PICKUP
DIFFERENTIAL STAGE 2 OPERATED
DIFFERENTIAL STAGE 2 PICKUP
GENERAL TRIP
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
TIME SYNCHRONISATION ERROR
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
CB R-PH POSITION
CB Y-PH POSITION
CB POSITION
89AE1 POSITION
89AE2 POSITION
89BE POSITION
89A POSITION
89B POSITION
89L POSITION
89LE POSITION
89 BE1 POSITION
89 BE2 POSITION
THE LOGICAL NODE FOR BUS EARTH SWITCHES, ISOLATOR & EARTHSWITCHES FOR 3 PH/1PH REACTORS & ITCs, e.g 89 BR, BRE, LR, LRE, RS1, RS2, RS1E, 89T,TE, 89AE2, 89BE2 MAY BE ASSIGNED AS PER AVAILABILITY/SCHEME
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
BCU LOCAL
BCU REMOTE
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
TRIP RELAY SUPERVISION
CARRIER CHANNEL-2 OUT
MAIN-2 RELAY FAULTY
EMERGENCY/MANUAL TRIP
SPEECH CHANNEL FAIL
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
89A POLE DESCREPENCY
89B POLE DESCREPENCY
CB DC SUPPLY-1/2 FAIL
CB SPRING NOT CHARGED B-PH
CB SPRING NOT CHARGED R-PH
CB SPRING NOT CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
86B TRIP RELAY FAULTY
86A TRIP RELAY FAULTY
86A TRIP RELAY OPERATED
86B TRIP RELAY OPERATED
89L POLE DESCREPENCY
CARRIER CHANNEL-1 OUT
CB TC-1 FAULTY
CB TC-2 FAULTY
CB POLE DESCREPENCY OPTD-1
CB POLE DESCREPENCY OPTD-2
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB READY
EMERGENCY/MANUAL CB CLOSE
DEVICE HEALTHY
CB POSITION NO SYNC
CB CLOSE INTERLOCK
89AE2 OPEN INTERLOCK
89BE OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
89L OPEN INTERLOCK
89LE OPEN INTERLOCK
DC-1 FAIL
DC-2 FAIL
BUSBAR 7ES-B1 OPEN(BUS EARTH SWITCH)
BUSBAR 7ES-B2 OPEN(BUS EARTH SWITCH)
BUSBAR 7ES-B1 CLOSE INTERLOCK
BUSBAR 7ES-B2 CLOSE INTERLOCK
GOOSE RECEIPT FAIL/TROUBLE
DFR/DR FAIL ALARM
GOOSE RECEIPT FAIL/TROUBLE
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
A/R READY
A/R UNSUCCESSFUL
A/R START
A/R SUCCESSFUL
RECLAIM IN PROGRESS
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
Tie CB A/R PRIORITY CLOSE
MAIN/TIE BCU HEALTHY
AR SINGLE PHASE TRIP PERMITTED
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
MEASUREMENT
POWER FACTOR
FREQUENCY
ACTIVE POWER
REACTIVE POWER
APPARENT POWER
I-R-PH CURRENT
I-Y-PH CURRENT
I-B-PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
SURGE ARRESTER B-PH
SURGE ARRESTER R-PH
SURGE ARRESTER Y-PH
CB R-PHASE OPERATION COUNTER
CB Y-PHASE OPERATION COUNTER
CB B-PHASE OPERATION COUNTER
COMMANDS
CB CONTROL
89AE1 CONTROL
89AE2 CONTROL
89BE CONTROL
89A CONTROL
89B CONTROL
89L CONTROL
89LE CONTROL
CB CONTROL NO SYNC
86A TRIP RELAY RESET COMMAND
86B TRIP RELAY RESET COMMAND
A/R ON CONTROL
A/R OFF CONTROL
MAIN-1 LED RESET
MAIN-2 LED RESET
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
FAULT CURRENT
FAULT LOCATION DISTANCE
MAIN-1 CARRIER RECEIVE CHANNEL-1
MAIN-1 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-1
MAIN-2 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-2
MAIN-2 CARRIER SEND CHANNEL-2
MAIN-1 CARRIER RECEIVE CHANNEL-2
MAIN-1 CARRIER SEND CHANNEL-2
DT RECEIVE CHANNEL-1
DT SEND CHANNEL-1
DT RECEIVE CHANNEL-2
DT SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER SEND CHANNEL-2
CARRIER SEND CHANNEL-1
DIRECT TRIP RECEIVED CHANNEL-1
DIRECT TRIP SEND CHANNEL-1
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
BINARY INPUT (Single Point)
DIRECT TRIP SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
NO VOLTAGE IN LINE
A/R BLOCK
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
DIRECT TRIP SEND CHANNEL-1
GOOSE RECEIPT FAIL/TROUBLE
MAIN-2 RELAY FAIL
89L OPEN FOR STUB
DIRECT TRIP RECEIVED CHANNEL-1
LBB OPERATED
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
EMERGENCY/MANUAL CLOSE
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER FAULTY
SOTF PICKUP
SOTF TRIP( OC)
SOTF TRIP( IMPEDANCE Z1B)
CARRIER SEND CHANNEL-1
CARRIER SEND CHANNEL-2
DIRECT TRIP RECEIVED CHANNEL-2
CARRIER RECEIVED
CARRIER ADDIED TRIP/Z COM. TRIP
MAIN A/R OPTD
TIE A/R OPTD
CB MANUAL CLOSE
CB MANUAL TRIP
86 GROUP-A OPTD
86 GROUP-B OPTD
MAIN A/R START
TIE A/R START
DISTANCE ZONE-1 PICKUP
DISTANCE PROTN ZONE-1 TRIP
DISTANCE PROTN ZONE-1 R-PH TRIP
DISTANCE PROTN ZONE-1 Y-PH TRIP
DISTANCE PROTN ZONE-1 B-PH TRIP
DISTANCE ZONE-2 PICKUP
DISTANCE PROTN ZONE-2 TRIP
DISTANCE PROTN ZONE-2 R-PH TRIP
DISTANCE PROTN ZONE-2 Y-PH TRIP
DISTANCE PROTN ZONE-2 B-PH TRIP
DISTANCE ZONE-3 PICKUP
DISTANCE PROTN ZONE-3 TRIP
DISTANCE ZONE-4 PICKUP
DISTANCE PROTN ZONE-4 TRIP
DISTANCE PROTN ZONE-4 R-PH TRIP
DISTANCE PROTN ZONE-4 Y-PH TRIP
DISTANCE PROTN ZONE-4 B-PH TRIP
DISTANCE PROTN ZONE-1B PICKUP
DISTANCE PROTN ZONE-1B TRIP
DISTANCE PROTN ZONE-1B B-PH TRIP
DISTANCE PROTN ZONE-1B R-PH TRIP
DISTANCE PROTN ZONE-1B Y-PH TRIP
DISTANCE PROTN ZONE-5 PICKUP
STUB PICKUP
STUB OPERATED
DEF FAULT PICKUP
DEF FAULT TRIP
OVERVOLTAGE STAGE-1-PH-N PICKUP
OVERVOLTAGE STAGE-1 -PH-N TRIP
OVERVOLTAGE STAGE-2-PH-N PICKUP
OVERVOLTAGE STAGE-2-PH-N TRIP
OVERVOLTAGE STAGE-1-PH-PH PICKUP
OVERVOLTAGE STAGE-1-PH-PH TRIP
OVERVOLTAGE STAGE-2-PH-PH PICKUP
OVERVOLTAGE STAGE-2-PH-PH TRIP
POWER SWING ZONE-1 DETECTED
POWER SWING ZONE-1 BLOCK
POWER SWING ZONE-1B DETECTED
POWER SWING ZONE-1B BLOCK
POWER SWING ZONE-2 DETECTED
POWER SWING ZONE-2 BLOCK
POWER SWING ZONE-3 DETECTED
POWER SWING ZONE-3 BLOCK
POWER SWING ZONE-4 DETECTED
POWER SWING ZONE-4 BLOCK
BUSBAR PROTN OPTD
RELAY LED RESET
MAIN BCU FAIL
TIE BCU FAIL
MANUAL DR TRIGGER
GENERAL TRIP
DEVICE HEALTHY
MAIN-2 PROTN OPTD
STUB BLOCKED
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
FAULT CURRENT
FAULT LOCATION DISTANCE
MAIN-1 CARRIER RECEIVE CHANNEL-1
MAIN-1 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-1
MAIN-2 CARRIER SEND CHANNEL-1
MAIN-2 CARRIER RECEIVE CHANNEL-2
MAIN-2 CARRIER SEND CHANNEL-2
MAIN-1 CARRIER RECEIVE CHANNEL-2
MAIN-1 CARRIER SEND CHANNEL-2
DT RECEIVE CHANNEL-1
DT SEND CHANNEL-1
DT RECEIVE CHANNEL-2
DT SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER SEND CHANNEL-2
CARRIER SEND CHANNEL-1
DIRECT TRIP RECEIVED CHANNEL-1
DIRECT TRIP SEND CHANNEL-1
CARRIER FAIL CHANNEL-1
CARRIER FAIL CHANNEL-2
BINARY INPUT (Single Point)
LINE DIFFERENTIAL GENERAL TIP
LINE DIFFERENTIAL REMOTE TRIP
LINE DIFFERENTIAL R-PH TRIP
LINE DIFFERENTIAL Y-PH TRIP
LINE DIFFERENTIAL -PH TRIP
LINE COMMUNICATION CHANNEL-1 FAULTY
LINE COMMUNICATION CHANNEL-2 FAULTY
DIRECT TRIP SEND CHANNEL-2
CARRIER FAIL CHANNEL-1
NO VOLTAGE IN LINE
A/R BLOCK
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
DIRECT TRIP SEND CHANNEL-1
GOOSE RECEIPT FAIL/TROUBLE
MAIN-2 RELAY FAIL
89L OPEN FOR STUB
DIRECT TRIP RECEIVED CHANNEL-1
LBB OPERATED
TIME SYNCHRONISATION ERROR
VT FUSE FAILURE
BROKEN CONDUCTOR
EMERGENCY/MANUAL CLOSE
CARRIER RECEIVED CHANNEL-1
CARRIER RECEIVED CHANNEL-2
CARRIER FAULTY
SOTF PICKUP
SOTF TRIP( OC)
SOTF TRIP( IMPEDANCE Z1B)
CARRIER SEND CHANNEL-1
CARRIER SEND CHANNEL-2
DIRECT TRIP RECEIVED CHANNEL-2
CARRIER RECEIVED
CARRIER ADDIED TRIP/Z COM. TRIP
MAIN A/R OPTD
TIE A/R OPTD
CB MANUAL CLOSE
CB MANUAL TRIP
86 GROUP-A OPTD
86 GROUP-B OPTD
MAIN A/R START
TIE A/R START
DISTANCE ZONE-1 PICKUP
DISTANCE PROTN ZONE-1 TRIP
DISTANCE PROTN ZONE-1 R-PH TRIP
DISTANCE PROTN ZONE-1 Y-PH TRIP
DISTANCE PROTN ZONE-1 B-PH TRIP
DISTANCE ZONE-2 PICKUP
DISTANCE PROTN ZONE-2 TRIP
DISTANCE PROTN ZONE-2 R-PH TRIP
DISTANCE PROTN ZONE-2 Y-PH TRIP
DISTANCE PROTN ZONE-2 B-PH TRIP
DISTANCE ZONE-3 PICKUP
DISTANCE PROTN ZONE-3 TRIP
DISTANCE ZONE-4 PICKUP
DISTANCE PROTN ZONE-4 TRIP
DISTANCE PROTN ZONE-4 R-PH TRIP
DISTANCE PROTN ZONE-4 Y-PH TRIP
DISTANCE PROTN ZONE-4 B-PH TRIP
DISTANCE PROTN ZONE-1B PICKUP
DISTANCE PROTN ZONE-1B TRIP
DISTANCE PROTN ZONE-1B B-PH TRIP
DISTANCE PROTN ZONE-1B R-PH TRIP
DISTANCE PROTN ZONE-1B Y-PH TRIP
DISTANCE PROTN ZONE-5 PICKUP
STUB PICKUP
STUB OPERATED
DEF FAULT PICKUP
DEF FAULT TRIP
OVERVOLTAGE STAGE-1-PH-N PICKUP
OVERVOLTAGE STAGE-1 -PH-N TRIP
OVERVOLTAGE STAGE-2-PH-N PICKUP
OVERVOLTAGE STAGE-2-PH-N TRIP
OVERVOLTAGE STAGE-1-PH-PH PICKUP
OVERVOLTAGE STAGE-1-PH-PH TRIP
OVERVOLTAGE STAGE-2-PH-PH PICKUP
OVERVOLTAGE STAGE-2-PH-PH TRIP
POWER SWING ZONE-1 DETECTED
POWER SWING ZONE-1 BLOCK
POWER SWING ZONE-1B DETECTED
POWER SWING ZONE-1B BLOCK
POWER SWING ZONE-2 DETECTED
POWER SWING ZONE-2 BLOCK
POWER SWING ZONE-3 DETECTED
POWER SWING ZONE-3 BLOCK
POWER SWING ZONE-4 DETECTED
POWER SWING ZONE-4 BLOCK
BUSBAR PROTN OPTD
RELAY LED RESET
MAIN BCU FAIL
TIE BCU FAIL
MANUAL DR TRIGGER
GENERAL TRIP
DEVICE HEALTHY
MAIN-2 PROTN OPTD
STUB BLOCKED
SETTINGS CHANGED
RELAY IN TEST MODE
IED MODEL
Voltage Level
INFORMATION TYPE
MCU-2 UNHEALTHY
BREAKER FAILURE TRANSFER TRIP
TIME SYNCHRONISATION ERROR
BUSBAR TRIP
BAY UNIT-01 FAILURE
BAY UNIT-02 FAILURE
BAY UNIT-03 FAILURE
BAY UNIT-03 FAILURE
BAY UNIT-05 FAILURE
BAY UNIT-06 FAILURE
BAY UNIT-07 FAILURE
BAY UNIT-08 FAILURE
BUS-1 PROTECTION BLOCKED BY HANDLE
BUS-2 PROTECTION BLOCKED BY HANDLE
BUS-1 PROTECTION BLOCKED BY INTERM STATE
BUS-2 PROTECTION BLOCKED BY INTERM STATE
CURRENT SUPERVISION BUS-1
CURRENT SUPERVISION BUS-2
Trip command BF for BUS-1 R-PH
Trip command BF for BUS-1 Y-PH
Trip command BF for BUS-1 B-PH
Trip command BF for BUS-2 R-PH
Trip command BF for BUS-2 Y-PH
Trip command BF for BUS-2 B-PH
3-PH Trip command BF for BUS-1
3-PH Trip command BF for BUS-2
LBB RETRIP
LBB TRIP
GENERAL TRIP
GENERAL TRIP R-PH
GENERAL TRIP Y-PH
GENERAL TRIP B-PH
DEVICE OK
BAY UNIT-01 OUT OF SERVICE
BAY UNIT-02 OUT OF SERVICE
BAY UNIT-03 OUT OF SERVICE
BAY UNIT-04 OUT OF SERVICE
BAY UNIT-05 OUT OF SERVICE
BAY UNIT-06 OUT OF SERVICE
BAY UNIT-07 OUT OF SERVICE
BAY UNIT-08 OUT OF SERVICE
Trip repeat Bay Unit-01 R-PH
Trip repeat Bay Unit-01 Y-PH
Trip repeat Bay Unit-01 B-PH
Trip repeat Bay Unit-02 R-PH
Trip repeat Bay Unit-02 Y-PH
Trip repeat Bay Unit-02 B-PH
Trip repeat Bay Unit-03 R-PH
Trip repeat Bay Unit-03 Y-PH
Trip repeat Bay Unit-03 B-PH
Trip repeat Bay Unit-04 R-PH
Trip repeat Bay Unit-04 Y-PH
Trip repeat Bay Unit-04 B-PH
Trip repeat Bay Unit-05 R-PH
Trip repeat Bay Unit-05 Y-PH
Trip repeat Bay Unit-05 B-PH
Trip repeat Bay Unit-06 R-PH
Trip repeat Bay Unit-06 Y-PH
Trip repeat Bay Unit-06 B-PH
Trip repeat Bay Unit-07 R-PH
Trip repeat Bay Unit-07 Y-PH
Trip repeat Bay Unit-07 B-PH
Trip repeat Bay Unit-08 R-PH
Trip repeat Bay Unit-08 Y-PH
Trip repeat Bay Unit-08 B-PH
Transfer Trip BUS-1
Transfer Trip BUS-2
BUS ZONE 1 TRIP
BUS ZONE 2 TRIP
BUSBAR CHECKZONE ALARM
BUSBAR CHECKZONE TRIP
BREAKER FAILURE - BUSBAR 1 BLOCKED
BREAKER FAILURE - BUSBAR 2 BLOCKED
ISOLATOR IN INTERMEDIATE STATUS
BAY N TRIP
BUSBAR BLOCKED DUE TO COMMUNICATION ERROR_Bay_n
BAY_N_BREAKER FAILURE R-PH INITIATION
BAY_N_BREAKER FAILURE Y-PH INITIATION
BAY_N_BREAKER FAILURE B-PH INITIATION
BAY_N_BREAKER FAILURE 3PH INITIATION
BAY_N_EXTERNAL BUSBAR ZONE n
BAY_N_BREAKER FAILURE RETRIP
BAY_N_BREAKER FAILURE BACKTRIP
BAY_N_BREAKER FAILURE RPH- RETRIP
BAY_N_BREAKER FAILURE YPH- RETRIP
BAY_N_BREAKER FAILURE BPH- RETRIP
BBP CENTRAL UNIT IED UNHEALTHY
SETTING CHANGE
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
MCU-1 UNHEALTHY
BREAKER FAILURE TRANSFER TRIP
TIME SYNCHRONISATION ERROR
BUSBAR TRIP
BAY UNIT-01 FAILURE
BAY UNIT-02 FAILURE
BAY UNIT-03 FAILURE
BAY UNIT-04 FAILURE
BAY UNIT-05 FAILURE
BAY UNIT-06 FAILURE
BAY UNIT-07 FAILURE
BAY UNIT-08 FAILURE
BUS-1 PROTECTION BLOCKED BY HANDLE
BUS-2 PROTECTION BLOCKED BY HANDLE
BUS-1 PROTECTION BLOCKED BY INTERM STATE
BUS-2 PROTECTION BLOCKED BY INTERM STATE
CURRENT SUPERVISION BUS-1
CURRENT SUPERVISION BUS-2
Trip command BF for BUS-1 R-PH
Trip command BF for BUS-1 Y-PH
Trip command BF for BUS-1 B-PH
Trip command BF for BUS-2 R-PH
Trip command BF for BUS-2 Y-PH
Trip command BF for BUS-2 B-PH
3-PH Trip command BF for BUS-1
3-PH Trip command BF for BUS-2
LBB RETRIP
LBB TRIP
GENERAL TRIP
GENERAL TRIP R-PH
GENERAL TRIP Y-PH
GENERAL TRIP B-PH
DEVICE OK
BAY UNIT-01 OUT OF SERVICE
BAY UNIT-02 OUT OF SERVICE
BAY UNIT-03 OUT OF SERVICE
BAY UNIT-04 OUT OF SERVICE
BAY UNIT-05 OUT OF SERVICE
BAY UNIT-06 OUT OF SERVICE
BAY UNIT-07 OUT OF SERVICE
BAY UNIT-08 OUT OF SERVICE
Trip repeat Bay Unit-01 R-PH
Trip repeat Bay Unit-01 Y-PH
Trip repeat Bay Unit-01 B-PH
Trip repeat Bay Unit-02 R-PH
Trip repeat Bay Unit-02 Y-PH
Trip repeat Bay Unit-02 B-PH
Trip repeat Bay Unit-03 R-PH
Trip repeat Bay Unit-03 Y-PH
Trip repeat Bay Unit-03 B-PH
Trip repeat Bay Unit-04 R-PH
Trip repeat Bay Unit-04 Y-PH
Trip repeat Bay Unit-04 B-PH
Trip repeat Bay Unit-05 R-PH
Trip repeat Bay Unit-05 Y-PH
Trip repeat Bay Unit-05 B-PH
Trip repeat Bay Unit-06 R-PH
Trip repeat Bay Unit-06 Y-PH
Trip repeat Bay Unit-06 B-PH
Trip repeat Bay Unit-07 R-PH
Trip repeat Bay Unit-07 Y-PH
Trip repeat Bay Unit-07 B-PH
Trip repeat Bay Unit-08 R-PH
Trip repeat Bay Unit-08 Y-PH
Trip repeat Bay Unit-08 B-PH
Transfer Trip BUS-1
Transfer Trip BUS-2
BUS ZONE 1 TRIP
BUS ZONE 2 TRIP
BUSBAR CHECKZONE ALARM
BUSBAR CHECKZONE TRIP
BREAKER FAILURE - BUSBAR 1 BLOCKED
BREAKER FAILURE - BUSBAR 2 BLOCKED
ISOLATOR IN INTERMEDIATE STATUS
BAY N TRIP
BUSBAR BLOCKED DUE TO COMMUNICATION ERROR_Bay_n
BAY_N_BREAKER FAILURE R-PH INITIATION
BAY_N_BREAKER FAILURE Y-PH INITIATION
BAY_N_BREAKER FAILURE B-PH INITIATION
BAY_N_BREAKER FAILURE 3PH INITIATION
BAY_N_EXTERNAL BUSBAR ZONE n
BAY_N_BREAKER FAILURE RETRIP
BAY_N_BREAKER FAILURE BACKTRIP
BAY_N_BREAKER FAILURE RPH- RETRIP
BAY_N_BREAKER FAILURE YPH- RETRIP
BAY_N_BREAKER FAILURE BPH- RETRIP
BBP CENTRAL UNIT IED UNHEALTHY
SETTING CHANGE
RELAY IN TEST MODE
IED MODEL
Voltage Level
CB Y-PH POSITION
CB B-PH POSITION
CB POSITION
89AE POSITION
89BE POSITION
89A POSITION
89B POSITION
BINARY INPUT (Single Point)
AUX POWER FAIL
TIME SYNCHRONISATION ERROR
BCU MODE
CT SF6 GAS PRESSURE REFILL LOW ALARM
CT SF6 GAS PRESSURE LOCKOUT
CB DC SUPPLY-1/2 FAIL
CB SPRING NOT CHARGED B-PH
CB SPRING NOT CHARGED R-PH
CB SPRING NOT CHARGED Y-PH
CB SF6 GAS PRESSURE LOCKOUT
MAIN DC-1 SUPPLY Fail
89A POLE DESCREPENCY
89B POLE DESCREPENCY
86A TRIP RELAY SUPERVISION
86A TRIP RELAY OPERATED
86B TRIP RELAY SUPERVISION
86B TRIP RELAY OPERATED
CB TC-1 R-PHASE FAULTY
CB TC-1 Y-PHASE FAULTY
CB TC-1 B-PHASE FAULTY
CB TC-2 R-PHASE FAULTY
CB TC-2 Y-PHASE FAULTY
CB TC-2 B-PHASE FAULTY
KIOSK AC 1_2 Power Fail
KIOSK AC 1_2 ON STATUS
DC SOURCE-2 FAIL
KIOSK HEAT DETECTED
KIOSK SMOKE DETECTED
EMERGENCY/MANUAL CB TRIP
PSD DEVICE HEALTHY
PSD DEVICE IN SERVICE
PSD SENSSOR ERROR/CB VOLTAGE ERROR
PSD BYPASS
PSD SYNCH OPERATION FAIL/DEFECTIVE SYNC DATA ALARM
SYNC OPERATION FAIL
TIE LBB RELAY UNHEALTHY
TIE LBB OPTD
CB POLE DESCREPENCY
CB SF6 GAS PRESSURE REFILL LOW ALARM
CB READY
EMERGENCY/MANUAL CB TRIP
CB MANUAL CLOSE
CB CONTROL NO SYNC
CB CLOSE INTERLOCK
89AE OPEN INTERLOCK
89BE OPEN INTERLOCK
89A OPEN INTERLOCK
89B OPEN INTERLOCK
DEVICE HEALTHY
GOOSE RECEIPT FAIL/TROUBLE
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
A/R READY
A/R UNSUCCESSFUL
A/R START
A/R SUCCESSFUL
RECLAIM IN PROGRESS
MAIN A/R LOCKOUT
TIE A/R LOCKOUT
Tie CB A/R PRIORITY CLOSE
MAIN/TIE BCU HEALTHY
AR SINGLE PHASE TRIP PERMITTED
CB NOT READY
A/R CLOSE COMMAND INDICATION
A/R IN PROGRESS
RELAY IN TEST MODE
SETTINGS CHANGED
CB MANUAL TRIP
CB MANUAL CLOSE
BUSBAR OPERATED
BCU IN LOCAL/REMOTE
MEASUREMENT
POWER FACTOR
FREQUENCY
REACTIVE POWER
APPARENT POWER
I-R -PH CURRENT
I-Y -PH CURRENT
I-B -PH CURRENT
R-Y VOLTAGE
Y-B VOLTAGE
B-R VOLYAGE
KIOSK TEMPERATURE
CB-B-PH COUNTER
CB-R-PH COUNTER
CB-Y-PH COUNTER
COMMANDS
89B CONTROL
89A CONTROL
89BE CONTROL
89AE CONTROL
CB CONTROL
89B CONTROL NO LOCK
89A CONTROL NO LOCK
89BE CONTROL NO LOCK
89AE CONTROL NO LOCK
CB CONTROL NO SYNC
CB CONTROL NO LOCK
86B TRIP RELAY RESET COMMAND
86A TRIP RELAY RESET COMMAND
BAY BLOCK
TELECONTROL BLOCK
GOOSE RECEIPT FAIL/TROUBLE
A/R ON CONTROL
A/R OFF CONTROL
A/R BLOCK
A/R FUNCTION OFF
A/R FUNCTION ON
CB READY FOR A/R
A/R UNSUCCESSFUL
A/R SUCCESSFUL
CB NOT READY
A/R CLOSE COMMAND INDICATION
TIE A/R START
A/R IN PROGRESS
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
INFORMATION TYPE
BREAKER FAILURE YPH- RETRIP
BREAKER FAILURE BPH- RETRIP
BREAKER FAILURE BACKTRIP
BREAKER FAILURE TRIP EXTERNAL
GENERAL TRIP
BREAKER FAILURE INITIATION 3-PH
TIE CB FAIL
TIE BCU UNHEALTHY
DEVICE HEALTHY
LBB EXTERNAL INITIATION 3-PH
TIME SYNCHRONISATION ERROR
LBB EXTERNAL INITIATION R-PH
LBB EXTERNAL INITIATION Y-PH
LBB EXTERNAL INITIATION B-PH
POLE DISCREPANCY PICKUP
POLE DISCREPANCY TRIP
LBB ACTIVE
DC-1 Fail
GOOSE RECEIPT FAIL/TROUBLE
SETTINGS CHANGED
RELAY IN TEST MODE
Voltage Level
BAY NUM.
Device
ISOLATOR
Isolator
Isolator
Isolator
Earth Switch
Earth Switch
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Main-1 Distance
Busbar Relay
Busbar Relay
Busbar Relay
Busbar Relay
Master Trip
Master Trip
Master Trip
Master Trip
Master Trip
Master Trip
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Line Differential Relay
Reactor
Reactor Differential
Backup Impedance
Backup Impedance
Backup Impedance
Buchholz
Buchholz
Fire Protection
Fire Protection
Fire Protection
TEED Protection
TEED Protection
Busbar Relay
Busbar Relay
Busbar Relay
Busbar Relay
Master Trip
Master Trip
Master Trip
Master Trip
Master Trip
Master Trip
ICT (Primary)
Differential
Overflux
Overflux
Backup O/C and E/F
Backup O/C and E/F
Backup O/C and E/F
Backup O/C and E/F
Busbar Relay
Busbar Relay
Busbar Relay
Busbar Relay
Buchholz
Buchholz
Cooling System
Cooling System
Cooling System
Cooling System
Cooling System
Fire Protection
Fire Protection
Fire Protection
Neutral O/C
Neutral O/C
Backup Impedance
Backup Impedance
Backup Impedance
Backup Impedance
Backup Impedance
Backup Impedance
Backup Impedance
Busbar Relay
Busbar Relay
Busbar Relay
Busbar Relay
Master Trip
Master Trip
Master Trip
Master Trip
Master Trip
Master Trip
ICT (Secondary)
Overflux
Backup O/C and E/F
Backup O/C and E/F
Backup O/C and E/F
Master Trip
Master Trip
Master Trip
Master Trip
Busbar Relay
Busbar Relay
Busbar Relay
Busbar Relay
Bus Bar
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
GIS Bay additional Signals
BCHRG & DCDB
BATCHRG220V-1
BATCHRG220V-2
BATCHRG220V-2
BATCHRG48V-1
BATCHRG48V-1
BATCHRG48V-2
BATCHRG48V-2
220V_DCDB-1
220V_DCDB-2
BATCHRG220V-1
BATCHRG220V-2
BATCHRG48V-1
BATCHRG48V-2
DGSET
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
DGSET-1
LTSUP
ACDB-BC
ACDB-BC
ACDB-BC
MSB_BC
MSB_BC
MSB_BC
TERTIARY
TERTIARY
TERTIARY
TERTIARY
TERTIARY
TERTIARY
TERTIARY
TERTIARY
TERTIARY
EPUMP
EPUMP
EPUMP
EPUMP
EPUMP
EPUMP
EPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
DPUMP
SMOKE ALARM
SMOKE ALARM
SMOKE ALARM
SMOKE ALARM
SMOKE ALARM
SMOKE ALARM
FIREPROTN
FIREPROTN
FIREPROTN
FIREPROTN
FIREPROTN
FIREPROTN
JPUMP-1
JPUMP-1
JPUMP-1
JPUMP-2
JPUMP-2
JPUMP-2
SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
AUX_SYSTEM
COMMON
AIRCON
F_KIOSK_1
GATEWAY
LOCAL_HMI
LOCAL_HMI
BAY NO
Description
ASDU Common Address
Common Address Size of ASDU
Information object Address Structure
Frame Max Length
MV Periodic Cycle
Binary Time Stamp Size
T0: Connection Time Out
T1: APDU Time Out
T2: Acknowledge Time Out
T3: Test Frame Time Out
K: Send Acknowledgement Frames (APDU)
W: Acknowledgement Received Frame (APDU)
Time Synchronisation
Cause of Transmission
Discription
Debouncing Time
Filtering Delay
Discription
Circuit Breaker (ON/OFF)
Circuit breaker (Check synch bypass)
Isolator
Trip Relay & L/O Relays reset
Control Switching Device (CSD) BYPASS COMMAND & Status
Fire fighting tank Water level, Manual Open/Close status (One SPS for each level)
Auto/Manual, Local/Remote
Description
Analog
Description
Single Point Status (SPS)
Double Point Status (DPS)
Measurement Value (MV) or Analog Value (AI)
Double Point Control (DPC)
Single Point Control (SPC)
ISOLATOR SIGNALS
SIGNAL NAME
CB OPENED / CLOSED
CB R-PH OPENED / CLOSED
CB Y-PH OPENED / CLOSED
CB B-PH OPENED / CLOSED
CB MANUAL OPEN
CB MANUAL CLOSE
POLE DISCREPANCY ALARM WITHIN PHASE.
POLE DISCREPANCY ALARM ACROSS PHASE.
CB DC SUPPLY 1/2 FAIL
CB AC SUPPLY FAIL
CB SPRING DISCHARGE
CB LOW AIR PRESSURE
CB LOW HYDRAULIC PRESSURE
CB SF6 GAS PRESSURE FIRST STAGE LOW ALARM
CB SF6 LOCK OUT ALARM ( SECOND STAGE )
CB TC1 Faulty
CB TC2 Faulty
CB TROUBLE ALARM
CB MCB TRIPPED (Motor/Heating/Lighting)
CB INTERLOCK ENABLED
LBB PROTECTION OPERATED
CB OPERATION LOCKOUT
CB COMPRESSOR / PUMP ON
CONTROL SWITCH DEVICE BYPASSED
CONTROL SWITCH DEVICE TROUBLE
BYPASS CMD FOR CNTRL SWITCH DEVICE
CB OPEN / CLOSE COMMAND
CB CHECK SYNC BYPASS COMMAND
LINE DIFFERENTIAL PROTECTION SIGNALS
SIGNAL NAME
MAIN-1 OPERATED
MAIN-1 ZONE1 TRIP
MAIN-1 ZONE2 TRIP
MAIN-1 ZONE3 TRIP
MAIN-1 REVERSE ZONE TRIP
MAIN-1 PSB DETECTED
MAIN-1 CVT FUSE FAILURE
MAIN-1 RELAY FAULTY
MAIN-1 DEF OPERATED
MAIN-1 SOTF OPERATED
MAIN-1 CARRIER SEND CH-1
MAIN-1 CARRIER SEND CH-2
MAIN-1 CARRIED RECD CH-1
MAIN-1 CARRIED RECD CH-2
MAIN-1 O/V STAGE-1 TRIP
MAIN-1 O/V STAGE-2 TRIP
MAIN-1 STUB PROTN OPERATED
MAIN-1 STUB_ENABLED
MAIN-1 CARRIER AIDED TRIP
MAIN-1 BROKEN CONDUCTOR ALARM
MAIN-1 A/R BLOCK
MAIN-1 CARRIER SWITCH IN OUT
MAIN-1 WEAK END INFEED OPTD.
MAIN-1 OVERVOLTAGE START
DIRECT TRIP SEND CHANNEL 1
DIRECT RECEIVED CHANNEL 1
DIRECT TRIP SEND CHANNEL 2
DIRECT RECEIVED CHANNEL 2
CARRIER FAIL CH-1
CARRIER FAIL CH-2
DC SOURCE-1 FAIL
DC SOURCE-2 FAIL
CT LOSS SF6 R PH
CT LOSS SF6 Y PH
CT LOSS SF6 B PH
SIGNAL NAME
A/R IN AUTO / NONAUTO MODE
A/R IN BLOCK MODE
AUTORECLOSE LOCKOUT
AUTORECLOSE OPERATED
AUTORECLOSE UNSUCCESFUL
CB NOT READY FOR A/R
A/R/IN AUTO/NONAUTO COMMAND
RESET A/R LOCKOUT RELAY
PTS Switch in Normal/Transfer Mode Command
ICT/REACTOR PROTECTION SIGNALS
SIGNAL NAME
LOW OIL LEVEL ALARM
BUCHHOLZ ALARM
BUCHHOLZ TRIP
OTI ALARM
OTI TRIP
WTI ALARM
WTI TRIP
PRV-1 TRIP
PRV-2 TRIP
SUDDEN PRESSURE RELAY TRIP
OSR-1 Trip
OSR-2 Trip
FIRE IN REACTOR/ICT
DELUGE VALVE OPTD
DC SOURCE-1 FAIL
DC SOURCE-2 FAIL
SHUT OFF VALVE OPERATED
OLTC PRV TRIP OPTD
OLTC OIL LEVEL ALARM
OLTC DRIVE MOTOR FAULTY
DIRECT WDG TEMP MONITORING TRIP
FANS FAIL TO START BANK A
FANS FAIL TO START BANK B
PUMPS FAIL TO START BANK A
PUMPS FAIL TO START BANK B
OIL FLOW LOW ALARM BANK
REACTOR COOLING SYSTEM TROUBLE
TEED PROTECTION OPTD
DGA CH4 VALUE
DGA C2H6 VALUE
DGA C2H4 VALUE
DGA N2 VALUE
BUS BAR PERIPHERAL UNITS- BAY WISE
SIGNAL NAME
M1 BB Z1 OPERATED
M2 BB Z1 OPERATED
M1 BB Z2 OPERATED
M2 BB Z2 OPERATED
M1 BB Z1 OUT OF SERVICE
M2 BB Z1 OUT OF SERVICE
M1 BB Z2 OUT OF SERVICE
M2 BB Z2 OUT OF SERVICE
Main-1 BB RELAY UNHEALTHY
Main-2 BB RELAY UNHEALTHY
M1 BB Z1 BLOCK (Circuitry fault, out of service, fibrecom and any other conditions etc to be grouped)
M2 BB Z1 BLOCK(Circuitry fault, out of service, fibrecom and any other conditions etc to be grouped)
M1 BB Z2 BLOCK(Circuitry fault, out of service, fibrecom and any other conditions etc to be grouped)
M2 BB Z2 BLOCK(Circuitry fault, out of service, fibrecom and any other conditions etc to be grouped)
M1 BB Z1 CT TROUBLE
M2 BB Z1 CT TROUBLE
M1 BB Z2 CT TROUBLE
M2 BB Z2 CT TROUBLE
MAIN-1 ZONE X AND ZONE Y MERGED/INTERCONNECTED
MAIN-2 ZONE X AND ZONE Y MERGED/INTERCONNECTED
VOLTAGE R-Y PHASE
VOLTAGE Y-B PHASE
VOLTAGE B-R PHASE
FREQUENCY
BUS BAR CHECK ZONE OPERATED
BUS BAR CHECK ZONE CT SUPV ALARM
BUS BAR CHECK ZONE OUT OF SERVICE
BUS BAR CHECK ZONE RELAY UNHEALTHY
DG SET SIGNALS
SIGNAL NAME
ACDB INCOMER-1 OPEN/CLOSE
ACDB INCOMER-1 U/V PROTN. RLY OPTD
ACDB INCOMER-1 OPEN/CLOSE COMMAND
ACDB BUS COUPLER OPEN/CLOSE
ACDB BC SUPERVISION OF CONTROL SUPPLY
ACDB BC OPEN/CLOSE COMMAND
MSB-1 CB OPEN/CLOSE
AUX. TRAFO-1 BUCHHOLZ ALARM
AUX. TRAFO-1 WTI ALARM
AUX. TRAFO-1 OTI ALARM
AUX. TRAFO-1 BUCHHOLZ TRIP
AUX. TRAFO-1 WTI TRIP
AUX. TRAFO-1 OTI TRIP
I/C-1 O/C PROTECTION RELAY TRIP
I/C-1 E/F PROTECTION RELAY TRIP
MSB BUS-1 U/V OPTD
MSB-1 PHASE SEQUENCE NEGATIVE ALARM
MSB INCOMER-1 OPEN/CLOSE COMMAND
MSB-1 VOLTAGE (R-Y PHASE)
MSB-1 VOLTAGE (Y-B PHASE)
MSB-1 VOLTAGE (B-R PHASE)
MSB-1 CURRENT (R-PHASE)
MSB-1 CURRENT (Y-PHASE)
MSB-1 CURRENT (B-PHASE)
MSB-1 ACTIVE POWER(KW)
MSB-1 REACTIVE POWER(KVAR)
MSB BUS COUPLER BREAKER OPEN/CLOSE
MSB_BC SUPERVISION OF CONTROL SUPPLY
MSB BC OPEN/CLOSE COMMAND
TERTIARY-EARTH SWITCH OPEN/CLOSE
TERTIARY-CB OPEN /CLOSE
TERTIARY-ISO OPEN /CLOSE
TERTIARY-CB INTERLOCK ENABLED
TERTIARY-ISO INTERLOCK ENABLED
TERTIARY-CB TRIPPED ON PROTN
TERTIARY-CB OPEN /CLOSE COMMAND
TERTIARY-ISO OPEN /CLOSE COMMAND
48V BATTERY CHARGER -2 ON FLOAT/BOOST MODE
220V DCDB -1 EARTH FAULT
220V DCDB -2 EARTH FAULT
220V BATTERY CHARGER-1 TROUBLE
220V BATTERY CHARGER-2 TROUBLE
48V BATTERY CHARGER-1 TROUBLE
48V BATTERY CHARGER-2 TROUBLE
220V DCDB -1 VOLTAGE
220V BATTERY SET-1 CURRENT
220V DCDB -2 VOLTAGE
220V BATTERY SET-2 CURRENT
48V DCDB -1 VOLTAGE
48V BATTERY SET-1 CURRENT
48V DCDB -2 VOLTAGE
48V BATTERY SET-2 CURRENT
220V BATTERY CHARGER-1 CURRENT
220V BATTERY CHARGER-2 CURRENT
48V BATTERY CHARGER-1 CURRENT
48V BATTERY CHARGER-2 CURRENT
Differential Relay
BAY NO
52BBR-RPh
52BBR-YPh
52BBR-Bph
MASTER TRIP RST
BAY NO
BAY NUM.
BUS-X VT
BUS-X VT
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
BAY NUM.
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
BAY NUM.
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
Description
ASDU Common Address
Common Address Size of ASDU
Information object Address Structure
Frame Max Length
MV Periodic Cycle
Binary Time Stamp Size
T0: Connection Time Out
T1: APDU Time Out
T2: Acknowledge Time Out
T3: Test Frame Time Out
K: Send Acknowledgement Frames (APDU)
W: Acknowledgement Received Frame (APDU)
Time Synchronisation
Cause of Transmission
Discription
Debouncing Time
Filtering Delay
Discription
Circuit Breaker (ON/OFF)
Circuit breaker (Check synch bypass)
Isolator
Tap Changer status & RAISE/LOWER control command
Trip Relay & L/O Relays reset
Control Switching Device (CSD) BYPASS COMMAND & Status
Fire fighting tank Water level, Manual Open/Close status (One SPS for each level)
Control Authority Transfer signals (NTAMC/BNTAMC/RTAMC)
Auto/Manual, Local/Remote
Other signals
Description
Tap Position (1- 25)
MW, MVAR, Current, Freq, Volatge
Temperature, Humidity
Fire fighting System Water pressure
DC Supply Volatge /Current
DG set & FF engine Battery volatge
Description
Analog
Analog spontaneous transmission
Description
Single Point Status (SPS)
Double Point Status (DPS)
Measurement Value (MV) or Analog Value (AI)
Double Point Control (DPC)
Single Point Control (SPC)
Station ID shall be a unique number for each substation to be provided by NTAMC Control Center
A Dummy Circuit Breaker to be provided in the Aux BCU Panel in Substation Control Room to test healthiness of the communication link including Substation Gateway / RTU from NTAMC control center. The associated control & monitoring indication to be hard wired to Aux BCU for the same.
BAY NUM.
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
765kV BUS-X
AUXBCU
AUXBCU
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
STATCOM AUX
BAY NUM.
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
WIND SPEED
WIND DIRECTION
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
BAY NUM.
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
WIND SPEED
WIND DIRECTION
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
STATCOM
VOLT. LEVEL
VOLT. LEVEL
BYPASS CB SIGNALS
SIGNAL NAME
SYSTEM 1: MOV OVERLOAD
SYSTEM 1: MOV TEMPERATURE TRIP
SYSTEM 1: MOV TEMPERATURE GRADIENT LOW SET
SYSTEM 1: MOV TEMPERATURE GRADIENT HIGH SET
SYSTEM 1: MOV UNBALANCE
SYSTEM 1: MOV HIGH CURRENT
SYSTEM 1: SPARK GAP FAILED TO TRIGGER
SYSTEM 1: SPARK GAP DELAYED TRIGGER
SYSTEM 1: SPARK GAP PROLONGED CONDUCTION
SYSTEM 1: SPARK GAP SELF TRIGGER
SYSTEM 1: SPARK GAP TRIGGER (R,Y,B)
SYSTEM 1: BYPASS BREAKER FAIL
SYSTEM 1: PREVENT REINSERTION ACTIVE
SYSTEM 1: PERMANENT BYPASS
SYSTEM 1: TEMPORARY BYPASS PHASE(R,Y,B)
SYSTEM 1: REINSERTION
SYSTEM 1: LINE TRIP
SYSTEM 1: BYPASS PLATFORM PROTECTION
SYSTEM 1: BYPASS GAP PROTECTION
SYSTEM 1: CAPACITOR UNBALANCE ALARM
SYSTEM 1: CAPACITOR UNBALANCED TRIP
SYSTEM 1: CAPACITOR OVERLOAD ALARM
SYSTEM 1: CAPACITOR OVERLOAD TRIP
SYSTEM 1: MOV TRIP
SYSTEM 1: FAULT TO PLATFORM TRIP-1/2
SYSTEM 1: DC SUPPLY FAIL
SYSTEM1: EXTERNAL BYPASS
LINE DE-ENRGIZED
PROTECTION SYSTEM FAIL/BLOCKED-1
PROTECTION SYSTEM FAIL/BLOCKED-2
SIGNAL TRANSMISSION POWER FAIL
MASTER TRIP
DIRECT TRIP RECEIVE
COMMUNICATION CHANNEL FAIL
MOV FAIL
GPS TIME SYNC FAIL
CONTROL SYSTEM 1 HARDWARE ALARM
PROTECTION SYSTEM 1 HARDWARE ALARM
CONTROL & PROTECTION SYSTEM 1 COMMUNICATION FAULT
PROTECTION SYSTEM 1 MEASURING SYSTEM WARNING
CONTROL & PROTECTION SYSTEM POWER SUPPLY ALARM
CONTROL & PROTECTION SYSTEM REDUNDANCY DISTURBED
LINE SIDE 1: DE-ENERGIZED
LINE SIDE 2: DE-ENERGIZED
FIRE FIGHTING SYSTEM: ALARM
PROTECTION SYSTEM 1 MEASURING SYSTEM WARNING
LOCAL CONTROL ROOM TEMPERATURE ALARM
TFR FAULT
PERMANENT /MONITORING LOCKOUT DUE TO C&P SYSTEM
MOV BRANCH CURRENT R PHASE
MOV BRANCH CURRENT Y PHASE
MOV BRANCH CURRENT B PHASE
SPARK GAP CURRENT R PHASE
SPARK GAP CURRENT Y PHASE
SPARK GAP CURRENT B PHASE
PLATFORM CURRENT R PHASE
PLATFORM CURRENT Y PHASE
PLATFORM CURRENT B PHASE
BACK TO BACK
SIGNAL NAME
POLE-1 DC POWER
POLE-1 DC VOLTAGE
POLE-1 DC CURRENT
POLE-1 FIRING/EXTINCTION ANGLE
POLE-1 GROUND/METALLIC RETURN
POLE-1 POWER DIRECTION POWER FLOW DIRECTION NORMAL/REVERSE
POLE-1 BLOCKED/DEBLOCKED
POLE-1 OVERLOAD IN USE
POLE-1 POWER RAMP IN PROGRESS
POLE-1 DC VOLTAGE FULL/REDUCED
POLE-1 RUNBACK ACTIVATED INDICATION
POLE-1 POWER SWING MODULATION ON/OFF
POLE-1 FREQUENCY CONTROL ON/OFF
POLE-1 FREQUENCY CONTROL ACTIVATED
POLE-1 DC LINE TRANSIENT FAULT
POLE-1 IN P/I MODE
POLE 1 VBE/VCU SUMMARY FAULT
POLE 1 VALVE HALL SUMMARY TRIP
POLE-1 CONVERTER TRANSFORMER SUMMARY FAULT
POLE-1 VALVE COOLING SYSTEM FAULT
POLE-1 VALVE COOLING TRIP
POLE-1 DC YARD SUMMARY FAULT
POLE-1 VESDA TRIP
POLE-1 EMERGENCY SWITCH OFF
POLE-1 DC FILTER CONNECTED/DISCONNECTED
POLE-1 DC LINE FAULT
POLE-1 OPERATION AT POWER/CURRENT LIMIT
BIPOLE DC POWER
NEUTRAL AREA SUMMARY TRIP
ABSOLUTE MINIMUM FILTER CRITERIA NOT FULFILLED
DMR 1/2 CONNECTED
AUTOMATIC BIPOLE POWER CONTROL
MASTER STATION STATION A/ STATION B
RPC ON/OFF
RPC AUTO/MANUAL
STABILITY FUNCTION ENABLED
SIGNAL NAME
AC FILTER BANK MVAR
FILTER PROTECTION TRIP
MSR/MSC
SIGNAL NAME
COOLING SYSTEM-1 TRIP
COOLING SYSTEM-2 TRIP
STATCOM BOTH STATION CONTROLLER FAILURE TRIP
STATION CONTROLLER-1 START
STATION CONTROLLER-1 STOP
STATION CONTROLLER-2 START
STATION CONTROLLER-2 STOP
STATCOM STATION RUNNING
STATCOM STATION SEQUENCE FAIULRE
UNIT-1 CONTROLLER START
UNIT-1 CONTROLLER STOP
STATCOM UNIT-1 STOPPED
STATCOM UNIT-1 RUNNING
STATCOM UNIT-1 SEQUENCE FAIULRE
UNIT-2 CONTROLLER START
UNIT-2 CONTROLLER STOP
STATCOM UNIT-2 STOPPED
STATCOM UNIT-2 RUNNING
STATCOM UNIT-2 SEQUENCE FAIULRE
ONE KEY START
ONE KEY STOP
AUTOMATIC START/STOP SEQUENCE RUNNING
AUTOMATIC START/STOP SEQUENCE FAIL
(STATION) HV SIDE OVERVOLTAGE TRIP
(STATION) HV SIDE UNDERVOLTAGE TRIP
(STATION) HV SIDE OVERCURRENT TRIP
(STATION) HV IVT FAIL TRIP
EMERGENCY STOP
GROUP MESSAGE : STATION CONTROLLER A FAILURE (COMM. FAIL / HW FAIL)
GROUP MESSAGE : STATION CONTROLLER B FAILURE (COMM. FAIL / HW FAIL)
NEGATIVE SEQ. VOLTAGE CONTROL ENABLED
POD CONTROL ENABLE
SSOD CONTROL ENABLED
ADAPTIVE GAIN REDUCTION ENABLED
ADAPTIVE GAIN CLACULATION ENABLED
MSC-1 CONTROL MODE - AUTO. CONTROL SELLECTED
MSC-1 CONTROL MODE - AUTO. CONTROL SELLECTED
MSR-1 CONTROL MODE - AUTO. CONTROL SELLECTED
MSR-2 CONTROL MODE - AUTO. CONTROL SELLECTED
HV BR MAIN BAY CONTROL MODE - AUTO. CONTROL SELLECTED
HV BR TIE BAY CONTROL MODE - AUTO. CONTROL SELLECTED
AHU STATCOM UNIT 1-A RUNNING
AHU STATCOM UNIT 1-B RUNNING
AHU STATCOM UNIT 2-A RUNNING
AHU STATCOM UNIT 2-B RUNNING
V-REF SETTING
SLOPE/DROOP SETTING
DEAD-BAND UP SETTING
DEAD-BAND DOWN SETTING
Q-REF SETTING
CONTROL MODE : MANUAL Q CONTROL / AUTOMATIC VOLTAGE CONTROL
V-REF SETTING
DEAD-BAND UP SETTING
DEAD-BAND DOWN SETTING
SLOPE/DROOP SETTING
Q-REF SETTING
POD CONTROL ENABLE
SSOD CONTROL ENABLE
NEGATIVE SEQ. VOLTAGE CONTROL ENABLE
ADACTIVE GAIN REDUCTION ENABLE
ADACTIVE GAIN CALCULATION ENABLE
MSC-1CONTROL MODE - AUTOMATIC / MANUAL
MSC-2 CONTROL MODE - AUTOMATIC / MANUAL
MSR-1 CONTROL MODE - AUTOMATIC / MANUAL
MSR-2 CONTROL MODE - AUTOMATIC / MANUAL
HV BR MAIN BAY CONTROL MODE - AUTOMATIC
HV BR TIE BAY CONTROL MODE - AUTOMATIC
ONE KEY START
ONE KEY STOP
TFR TRIGGER CMD
MV BUS PROTECTION RELAY FAILURE
VOLT. LEVEL
VOLT. LEVEL
TSC/TCR
Signal name
SVC CONTROLLER 1 ALARM
SVC CONTROLLER 1 TRIP
SVC CONTROLLER 2 ALARM
SVC CONTROLLER 2 TRIP
Q-MODE ENABLED
SVC AUTOMATIC MODE (VCM)
SVC CONTROL FROM LOCAL HMI 1/2
SVC CONTROL FROM RCI 1/2
SVC CONTROL FROM REMOTE HMI 1/2
SVC MANUAL MODE (FSM)
SVC OFF
SVC ON
SVC READY FOR SWITCHING ON
SVC READY FOR SWITCHING OFF
SVC AUTOMATIC GAIN ADJUSTMENT ENABLED
DTF 1/2 FILTER DISCHARGE TIME RUNNING
SVC Control DEGRADED MODE
POWER OSCILLATION DAMPING ENABLED
POWER OSCILLATION DAMPING DISABLED
SVC AUTOMATIC GAIN ADJUSTMENT DISABLED
SVC Q-MODE DISABLED
SVC CONTROL FROM FIELD
SVC CONTROLLER-1/2 ALARM
SVC CONTROLLER-1/2 TRIP
SVC -PROTN SYSTEM-1/2 ALARM
CONTROL SYSTEM 1 ACTIVE
CONTROL SYSTEM 2 ACTIVE
SVC ON SEQUENCE RUNNING
SVC OFF SEQUENCE RUNNING
SVC NO SEQUENCE IS RUNNING
DIGITAL FAULT RECORDER FAULTY (DFR)
DIGITAL FAULT RECORDER TRIGGERED (DFR)
AC VOLTAGE STABELIZER ALARM
SVC -PROTN SYSTEM-1 ALARM
SVC -PROTN SYSTEM-1 TRIP
SVC -PROTN SYSTEM-2 ALARM
SVC -PROTN SYSTEM-2 TRIP
PROTN 1 - ANY TEST SWITCH IN USE
PROTN 2 - ANY TEST SWITCH IN USE
SVC EMERGENCY TRIP 1
SVC EMERGENCY TRIP 2
CONTROL VIA RCI 1/2 COMMAND
Q CONTROL MODE ENABLE/ DISABLE COMMAND
GAIN ADJUSTMENT ENABLE/ DISABLE COMMAND
POWER OSCILLATION DAMPING CONTROL ENABLE/ DISABLE COMMAND
REFERENCE VOLTAGE RAISE/ LOWER COMMAND
REACTIVE POWER MORE CAPACITIVE (RAISE)/ INDUCTIVE (LOWER) COMMAND
MANUAL MODE REACTIVE OUTPUT MORE CAPACITIVE (RAISE)/ INDUCTIVE (LOWER) COMMAND
CONTROL SYSTEM SLOPE RAISE/ LOWER COMMAND
VQ MINIMUM RAISE/ LOWER COMMAND
VQ MAXIMUM RAISE/ LOWER COMMAND
UNDER VOLTAGE DETECTION RAISE/ LOWER COMMAND
UNDER VOLTAGE RELEASE RAISE/ LOWER COMMAND
UNDER VOLTAGE DETECTION VALUE
UNDER VOLTAGE RELEASE VALUE
ACTUAL VOLTAGE VALUE
SVC REACTIVE POWER
FREQUENCY
CONTROLLER GAIN
SVC REACTIVE POWER REFERENCE VALUE
SVC REACTIVE POWER REFERENCE VALUE
SLOPE VALUE
FIXED SUSCEPTANCE REFERENCE VALUE
MINIMUM VALUE FOR Q-CONTROLLER
MAXIMUM VALUE FOR Q-CONTROLLER
GAIN REDUCTION FACTOR
DEGRADED MODE
SVC PRIMARY CURRENT R
SVC PRIMARY CURRENT Y
SVC PRIMARY CURRENT B
DIGITAL FAULT RECORDER FAULTY (DFR)
DIGITAL FAULT RECORDER TRIGGERED (DFR)
Voltage Level
Description of Remarks
Old Signal list
1. Distance relay - Missing internal signals related to functions such as AR, Weak-infeed, SOTF. 2. Addition of Differential Protection signals 3. Addition of Transformer phase wise Mechanical tripping signals 4. Addition of Centralized Busbar protection related signals. 5. Addition of tertiary transformer related protection signals. 6. Addition of Backup impedance protection signals for ICT & Reactor. 7. Addition of Directional OC & EF protection signals for ICT. 8. Addition of Mechanical trippings & alarms associated with REF. 9. Addition of NGR associated protection & CB Alarms 10. Addition of De-centralised - Busbar protection signals 11. Addition of Breaker failure protection initiation & Re-trip signals in standalone & centralized busbar protection 12. Addition of BCU – AR associated internal signals, TC phase wise, CSD related alarms, Bay wise measurements
IED MODEL
BB4_P741_87CUA
Auto generated
Port used (on gateway)
400KV SERVER M
BB4_P741_87CUA
IED name
Customer Ref
Panel Number
System;GosGGIO2
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
Protection;TrpPhsPDIF2
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
BB4_P741_87CUB
Auto generated
Port used (on gateway)
400KV SERVER M
BB4_P741_87CUB
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
Protection;TrpPhsPDIF2
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
SPARE
SPARE
System;OptGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
SPARE
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
SPARE
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CznPDIF1
Protection;BbpT01PDIF1
Protection;BbpT02PDIF1
Protection;BbpT02PDIF1
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;AlmGGIO1
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;DisPDIS5
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPSCH1
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
SPARE
IED name
Customer Ref
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Records;PriRFLO1
Records;PriRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DifPDIF1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
IED name
Customer Ref
Panel Number
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS4
SPARE
Protection;DifPDIF1
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Records;RFLO1
Records;RFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
R203_REL670_21M2
Auto generated
Port used (on gateway)
400KV SERVER M
R203_REL670_21M2
IED name
Customer Ref
Panel Number
LD0;ZCPSCH1
LD0;ZCPSCH1
LD0;ZMRPSB1
LD0;ZMRPSB1
LD0;BRCPTOC1
LD0;SMPPTRC1
LD0;STBPTOC1
LD0;ZCVPSOF1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;ZMCPDIS1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO1
LD0;SP16GGIO2
LD0;SP16GGIO2
LD0;ZMCAPDIS2
LD0;ZMCAPDIS2
LD0;ZMCAPDIS2
LD0;ZMCAPDIS2
LD0;ZMCAPDIS2
LD0;ZMCAPDIS3
LD0;ZMCAPDIS3
LD0;ZMCAPDIS4
LD0;ZMCAPDIS4
LD0;ZMCAPDIS5
EF4_1;EF4PTOC1
EF4_1;EF4PTOC1
OV2_1;OV2PTOV1
OV2_1;OV2PTOV1
OV2_1;OV2PTOV2
SPARE
IED name
Customer Ref
Panel Number
LD0;ZMCAPDIS5
LD0;ZMCPDIS2
LD0;ZMCPDIS2
LD0;ZMCPDIS2
LD0;ZMCAPDIS5
LD0;ZCPSCH1
LD0;SP16GGIO2
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
LD0;LMBRFLO1
LD0;LMBRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;EfmEl1PTOC1
Protection;EfmEl1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;VhzWg1PVPH1
Protection;VhzWg1PVPH2
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;HzrHvwPTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;VhzWg1PVPH1
Protection;VhzWg1PVPH2
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
Protection;PTRC1
Protection;CbfRBRF1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;SenRefPDIF1
SPARE
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
Protection;PTRC1
Protection;CbfRBRF1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
cos ft : Power factor
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
Protection;TrpPhsPDIF2
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
B203_LINE1
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Vbusbar RMS 2 value of the busbar voltage phase
cos ft : Power factor
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Vbusbar RMS 2 value of the busbar voltage phase
cos ft : Power factor
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Port used (on gateway)
400KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
cos ft : Power factor
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
SIGNAL
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
PROFILE
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
46 : SPE_HLA_Normal_Alarm
Port used (on gateway)
GE Reserved
Auto generated
Read Only
ERROR
Electrical Data
Equipment Link
Mp0HLAOIPrt
Mp0HLAOIPrt
Electrical Data
Equipment Link
Electrical Data
Equipment Link
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Mp0HLABoard
Sp0HLARev
Dp0000OpM
Mp0HLAIsag
Dp0000OpM
Mp0HLAOIPrt
Sp0HLARev
Electrical Data
Equipment Link
Sp0HLARev
Mp0HLAIsag
Sp0HLARev
Electrical Data
Equipment Link
Electrical Data
Equipment Link
Sp0HLARev
Sp0HLARev
Mp0HLAIsag
Electrical Data
Equipment Link
Electrical Data
Equipment Link
English
SYSTEM INFORMATION SERVER OI
1 | AgencyStatus
AGENCY STATUS
HEALTHY
FAULTY
Agency status
1 | AutomaticArchiving
AUTOMATIC ARCHIVING STATUS
HEALTHY
FAULTY
Auto archiving
1 | CentralArchiving
HISTORIAN DATABASE STATUS
Central archive
1 | CommDevice
OI SBUS LINK
HEALTHY
FAULTY
Device link
1 | LogQueue
LOGGING QUEUE STATUS
HEALTHY
FAULTY
Log Queue
1 | OperatingMode
OPERATING MODE
Operating mode
1 | RedDevice
REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
1 | RedundancyStatus
REDUNDANCY STATUS
Redundancy status
1 | SyncDevice
SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
1 | CouplingStatus
SBUS ACQUISITION STATUS
HEALTHY
FAULTY
IEC Coupling
1 | Printing
PRINTER STATUS
Printer status
1 | BackupPrinting
BACKUP PRINTER STATUS
BackupPrint stat
SYSTEM INFORMATION CLIENT OI
2 | CommS2K_C
CONNECTION STATUS
HEALTHY
FAULTY
OI client link
SYSTEM INFORMATION MiCOM C264
3 | DBIncoherency
DATABASE INCONSISTENCY
DB incoh. SPS
3 | DBSwitch_SPC
C264 DATABASE SWITCHING
EXECUTE
DB switch ctrl
3 | CommDevice
C264 SBUS LINK
HEALTHY
FAULTY
Device link
3 | DIAcquisitionStopped
DIGITAL INPUT ACQUISITION
FAULTY
HEALTHY
DI acq stopped
3 | LocRemDevice_DPC
C264 BAYS CONTROL MODE CHANGE
REMOTE
LOCAL
Loc/rem ctrl DPC
3 | LocRemDevice
C264 MANAGED BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote DPS
3 | LocRemDeviceForIEC
C264 BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote SPS
3 | MainInternalStatus
C264 FAULT LEVEL FOR REDUNDANCY
Main status MV
3 | ModeDevice_DPC
C264 FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
3 | OperatingMode
C264 OPERATING MODE
Operating mode
3 | RedChangeMode_SPC
C264 BIU REDUNDANCY RELAY CO 2
ACTIVATE
DEACTIVATE
Red mode ctrl
3 | RedChangeStatus_SPC
C264 BIU REDUNDANCY RELAY CO 1
ACTIVATE
DEACTIVATE
Red Status ctrl
3 | RedChangeMode
REDUNDANT C264 CHANGE MODE
ACTIVE
STANDBY
Red. change mode
3 | RedChangeStatus
REDUNDANT C264 STATUS
ACTIVE
STANDBY
Red. change stat
3 | SoftError
SOFTWARE ERROR DETECTED
Soft. error SPS
3 | SyncDevice
C264 SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
3 | TestDevice_DPC
C264 CHANGE EXPLOITATION MODE
NORMAL
Test control DPC
3 | WatchdogError
C264 WATCHDOG RELAY STATUS
HEALTHY
FAULTY
Watchdog SPS
3 | ModeDevice
C264 OPERATING MODE
RUNNING
MAINTENANCE
Device mode
3 | DisturbUCA2
DISTURBANCE FILE ON C264
READY
NOT READY
DREC ready
3 | CounterTop
C264 COUNTERS ACQUISITION TOP
Counter Top
3 | ExtClockStatus
GPS SYNCHRONISATION SOURCE
HEALTHY
FAULTY
Ext clock status
3 | RedDevice
C264 REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
3 | BuffOvGtw1
REPORT BUFFER OVERFLOW GTW 1
Buff Ov Gtw 1
3 | BuffOvGtw2
REPORT BUFFER OVERFLOW GTW 2
Buff Ov Gtw 2
3 | BuffOvOI
REPORT BUFFER OVERFLOW OI
Buff Ov Oi
3 | BuffOvOIBck
REPORT BUFFER OVERFLOW OI BACKUP
Buff Ov Oi Bck
3 | BIUStatus
BIU BOARD STATUS
BIU status
3 | GHUStatus
GHU BOARD STATUS
GHU status
3 | AIUStatus
AIU20x BOARD STATUS
AIU status
3 | AIUStatus
AIU21x BOARD STATUS
AIU status
3 | AOUStatus
AOU200 BOARD STATUS
AOU status
3 | DIUStatus
DIU BOARD STATUS
DIU status
3 | DOUStatus
DOU BOARD STATUS
DOU status
3 | CCUStatus
CCU BOARD STATUS
CCU status
3 | TIUStatus
TMU BOARD STATUS
TMU status
3 | HBUStatus
HBU BOARD STATUS
HBU status
3 | CommIED
IED CONNECTION STATUS TO C264
HEALTHY
FAULTY
IED SPS com.
3 | SyncIED
IED SYNCHRONISATION STATUS
HEALTHY
FAULTY
IED SPS Synchro.
3 | DisturbIED
IED DISTURBANCE FILE
READY
NOT READY
IED DREC ready
3 | ISAGRAFStatus
ISAGRAF STATUS
ISAGRAF status
3 | PrinterStatus
PRINTER STATUS DPS
Printer st. DPS
3 | Printing
LOCAL PRINTER STATUS
Printer Status
3 | RedSCADA
C264 SCADA PORT COMMUNICATION
ACTIVE
STANDBY
Redundancy SPS
3 | CommSCADA
SCADA CONNECTION STATUS TO C264
HEALTHY
FAULTY
SCADA SPS com.
3 | GlobalAIUStatus
ALL AIU STATUS
FAULTY
HEALTHY
All AIU status
3 | GlobalAOUStatus
ALL AOU STATUS
FAULTY
HEALTHY
All AOU status
3 | GlobalCCUStatus
ALL CCU STATUS
FAULTY
HEALTHY
All CCU status
3 | GlobalDIUStatus
ALL DIU STATUS
FAULTY
HEALTHY
All DIU status
3 | GlobalDOUStatus
ALL DOU STATUS
FAULTY
HEALTHY
All DOU status
3 | GlobalTMUStatus
ALL TMU STATUS
FAULTY
HEALTHY
All TMU status
3 | GlobaHBMUStatus
ALL HBU STATUS
FAULTY
HEALTHY
All HBU status
3 | GlobalIEDStatus
ALL IED STATUS
FAULTY
HEALTHY
All IED status
3 | GlobalPrinterStatus
ALL Printer STATUS
FAULTY
HEALTHY
All Printer stat
3 | GlobalRackLinkStatus
ALL RACK STATUS
FAULTY
HEALTHY
All rack status
3 | RackLinkStatus
RACK LINK STATUS
HEALTHY
FAULTY
Rack link status
3 | LocalAlarmAck_SPS
LOCAL ALARM ACKNOWLEDGEMENT
Local alarm ack
3 | SettingDone
SETTING DONE
Setting done
3 | SettingFileDiscordance
SETTING FILE DISCORDANCE
Setting disc.
3 | SettingInProgress
SETTING IN PROGRESS
Setting in prog.
3 | SettingIncoherency
SETTING INCOHERENCY
Setting incoher.
SYSTEM INFORMATION MiCOM C364
4 | DBIncoherency
DATABASE INCONSISTENCY
DB incoh. SPS
4 | DBSwitch_SPC
C364 DATABASE SWITCHING
EXECUTE
DB switch ctrl
4 | CommDevice
C364 SBUS LINK
HEALTHY
FAULTY
Device link
4 | LocRemDevice_DPC
C364 BAYS CONTROL MODE CHANGE
REMOTE
LOCAL
Loc/rem ctrl DPC
4 | LocRemDevice
C364 MANAGED BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote DPS
4 | LocRemDeviceForIEC
C364 BAYS IN CONTROL MODE
REMOTE
LOCAL
Local/remote SPS
4 | LogQueue
LOGGING QUEUE STATUS
HEALTHY
FAULTY
Log Queue
4 | ModeDevice_DPC
C364 FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
4 | OperatingMode
C364 OPERATING MODE
Operating mode
4 | SoftError
SOFTWARE ERROR DETECTED
Soft. error SPS
4 | SyncDevice
C364 SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
4 | TestDevice_DPC
C364 CHANGE EXPLOITATION MODE
NORMAL
Test control DPC
4 | WatchdogError
C364 WATCHDOG RELAY STATUS
HEALTHY
FAULTY
Watchdog SPS
4 | ModeDevice
C364 OPERATING MODE
RUNNING
MAINTENANCE
Device mode
4 | ExtClockStatus
GPS SYNCHRONISATION SOURCE
HEALTHY
FAULTY
Ext clock status
4 | RedDevice
C364 REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
4 | CommIED
IED CONNECTION STATUS TO C364
HEALTHY
FAULTY
IED SPS com.
4 | SyncIED
IED SYNCHRONISATION STATUS
HEALTHY
FAULTY
IED SPS Synchro.
4 | DisturbIED
IED DISTURBANCE FILE
READY
NOT READY
IED DREC ready
4 | ISAGRAFStatus
ISAGRAF STATUS
ISAGRAF status
4 | RedSCADA
C364 SCADA PORT COMMUNICATION
ACTIVE
STANDBY
Redundancy SPS
4 | CommSCADA
SCADA CONNECTION STATUS TO C364
HEALTHY
FAULTY
SCADA SPS com.
SYSTEM INFORMATION UCA2 IED
5 | CommDevice
IED SBUS LINK
HEALTHY
FAULTY
Device link
SYSTEM INFORMATION GATEWAY
6 | DBSwitch_SPC
GTW DATABASE SWITCHING
EXECUTE
DB switch ctrl
6 | CommDevice
GTW SBUS LINK
HEALTHY
FAULTY
Device link
6 | ModeDevice_DPC
GTW FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
6 | OperatingMode
GTW OPERATING MODE
Operating mode
6 | SyncDevice
GTW SYNCHRONISATION STATUS
HEALTHY
FAULTY
Synchronisation
6 | RedSCADA
GTW SCADA PORT COMMUNICATION
ACTIVE
STANDBY
Redundancy SPS
6 | CommSCADA
SCADA CONNECTION STATUS TO GTW
HEALTHY
FAULTY
SCADA SPS com.
6 | CommIED
IED CONNECTION STATUS TO GTW
HEALTHY
FAULTY
IED SPS com.
6| SyncIED
IED SYNCHRONISATION STATUS
HEALTHY
FAULTY
IED SPS Synchro.
6 | ISAGRAFStatus
ISAGRAF STATUS
ISAGRAF status
SYSTEM INFORMATION IEC 61850
7 | CommDevice
IED SBUS LINK
HEALTHY
FAULTY
Device link
7 | OperatingMode
IED OPERATING MODE
Operating mode
7 | ModeDevice_DPC
IED FORCE OPERATION MODE TO
OPERATIONNAL
MAINTENANCE
Mode control DPC
7 | RedDevice
REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
7 | DisturbUCA2
DISTURBANCE FILE ON IED
READY
NOT READY
DREC ready
7 | DisturbLD
LOGICAL DEVICE DISTURBANCE FILE
READY
NOT READY
LD DREC ready
7 | UCA2GenSPS
IEC61850 GENERIC SPS
HEALTHY
FAULTY
IEC61850 gen SPS
7 | UCA2GenDPS
IEC61850 GENERIC DPS
HEALTHY
FAULTY
IEC61850 gen DPS
7 | UCA2GenMPS
IEC61850 GENERIC MPS
IEC61850 gen MPS
7 | UCA2GenSPC
IEC61850 GENERIC SPC
HEALTHY
FAULTY
IEC61850 gen SPC
7 | UCA2GenDPC
IEC61850 GENERIC DPC
HEALTHY
FAULTY
IEC61850 gen DPC
7 | UCA2GenMV
IEC61850 GENERIC MV
IEC61850 gen MV
SYSTEM INFORMATION BAY OI
8 | AgencyStatus
AGENCY STATUS
HEALTHY
FAULTY
Agency status
8 | AutomaticArchiving
AUTOMATIC ARCHIVING STATUS
HEALTHY
FAULTY
Auto archiving
8 | CentralArchiving
HISTORIAN DATABASE STATUS
Central archive
8 | CommDevice
OI SBUS LINK
HEALTHY
FAULTY
Device link
8 | LogQueue
LOGGING QUEUE STATUS
HEALTHY
FAULTY
Log Queue
8 | OperatingMode
OPERATING MODE
Operating mode
8 | RedDevice
REDUNDANCY MODE
ACTIVE
STANDBY
Redundancy mode
8 | SyncDevice
SYNCHRONIZATION STATUS
HEALTHY
FAULTY
Synchronisation
8 | CouplingStatus
SBUS ACQUISITION STATUS
HEALTHY
FAULTY
IEC Coupling
8 | CommS2K_C
CONNECTION STATUS
HEALTHY
FAULTY
OI client link
Menu Option
Menu Option
GE Reserved
Auto generated
Read Only
Port used (on gateway)
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Power Factor
Customer Ref
Panel Number
Customer Ref
Panel Number
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Auto generated
Read Only
Port used (on gateway)
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
GE Reserved
Auto generated
Read Only
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
GE Reserved
Auto generated
Read Only
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
GE Reserved
Auto generated
Read Only
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
Reference
Equipment Link
GE Reserved
Auto generated
Read Only
Digital Inputs Board Number
Digital Outputs Board Number
Digital Outputs Board Number
DI/DO Board Number
DI/DO Board Number
Analog Input Board Number
Analog Input Board Number
CT/VT Board Number
DSP210 Board Number
Analog Output Board Number
IED name
IED name
IED name
IED name
IED name
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
Customer Ref
Issue
SERVER OI Name :
CLIENT OI Name :
MiCOM C264 Name :
MiCOM C364 Name :
UCA2 IED Name :
GATEWAY Name :
IEC 61850 Name :
BAY OI Name :
Français
SHEET : Page de Garde Client
SHEET : Page de Garde GE
REVISION
DESCRIPTION
CLIENT
CLIENT
CONTRAT N°
Commande N°
PROJET:
Nom du Projet
Numéro de Document :
Nom du Site
xyz-SC-DTL
SIGNATURE
Titre du document LISTE DE DONNEES DU SYSTEME DE Contrôle DE SOUS-STATION
DSAgile SYSTEME DE COMMANDE DE SOUS-STATION Liste de données
VERIFIE
APPROUVE
EDITE PAR:
TAILLE
PAGES
REVISION
GE Parc Eurêka 81, rue Euclide 34000 MONTPELLIER
ETABLI PAR
SHEET : Journal
Désignation :
Réf. GE :
PACIDL-A
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT DES DONNEES
Révision
Auteur
Compagnie
Modifications
FIN DES DONNEES
SHEET : Equipements
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
LISTE DES EQUIPEMENTS
Légende :
Réservé à GE
Lecture seule
Communication usuelle
Legacy T104 Maître
Legacy T101 Maître
Cartes
Révision
DESCRIPTION (NOM LONG)
COMMUNICATION
REDONDANCE
Nom de la Sous-station
Tranche mimic
MODE DE SYNCHRONISATION
NOM DU RESEAU
Adresse TCP/IP (IEC)
Nom de protocole
Nom de protocole
Nom de protocole
Nom de protocole
Id1 T104M (+ IED Adr)
Id2 T104M (+ IED Adr)
Id3 T104M (+ IED Adr)
Id4 T104M (+ IED Adr)
Id1 T101M (+ IED Adr)
Id2 T101M (+ IED Adr)
Id3 T101M (+ IED Adr)
Id4 T101M (+ IED Adr)
Id Protocole IEC61850
Id Protocole OPC
DIU2xx
Racks d'Extension
Commentaires
Modèle
Nom de la Feuille
RESUME
FIN DES DONNEES
SHEET : Arrangement des Calculateurs
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DESCRIPTION MATERIELLE DES CALCULATEURS MICOM
Légende :
Réservé à GE
Génération automatique
Lecture seule
ERREUR
C264 Rack d'Ext.
C264C Rack d'Ext.
Type de Calculateur (C264/C264C):
Face arriere
PRINCIPAL
REDONDANCE
ECRAN
COMMENTAIRES
Numéro de position devant:
NOM DU CALCULATEUR
NUMERO
BIU240 Port 1
BIU240 Port 2
CPU Port 1
CPU Port 2
Numéro de position arrière:
Type de Protocole
CPU 260 + COMMUNICATION
Vitesse de la communication (en Baud)
RS Type
Parité
Nombre de bits de stop
Nombre de bits
Gestion de RX
Gestion de TX
CTS Câblé
Câblage de DTS
Câblage de CD
Numéro logique:
Câblage de DCR
CPU 270 + COMMUNICATION
Type de Calculateur (C264/C264C):
Face arriere
PRINCIPAL
REDONDANCE
ECRAN
COMMENTAIRES
Numéro de position devant:
NOM DU CALCULATEUR
NUMERO
BIU240 Port 1
BIU240 Port 2
CPU Port 1
CPU Port 2
Numéro de position arrière:
Type de Protocole
TMU2x0 (slot 2/2)
TMU2x0 (slot 1/2)
CPU 260 + COMMUNICATION
Vitesse de la communication (en Baud)
RS Type
Parité
Nombre de bits de stop
Nombre de bits
Gestion de RX
Gestion de TX
CTS Câblé
Câblage de DTS
Câblage de CD
Numéro logique:
Câblage de DCR
CPU 270 + COMMUNICATION
FIN DES DONNEES
SHEET : C264_Template
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DESCRIPTION DU MiCOM C264
Légende :
Nom du Calculateur
Réservé à GE
Calculateur Redondant
Génération automatique
Type de Calculateur (C264/C264C)
Lecture seule
Passerelle
Ports utilisés (sur la passerelle)
SCADA 1
SCADA 2
SCADA 3
SCADA 4
Carte d'entrées numériques DIU32
Carte d'entrées numériques DIU2xx
Numéro de la carte d'entrées numériques
Position de la carte d'entrées numériques
Numéro rack d'extension de la carte d'entrées numériques
Réf. Client
Référence DI
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Carte de sorties numériques DOU20x
Numéro de la carte de sorties numériques
Position de la carte de sorties numériques
Numéro rack d'extension de la carte de sorties numériques
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Carte de sorties numériques HBU20x
Numéro de la carte de sorties numériques HBU
Position de la carte de sorties numériques HBU
Numéro rack d'extension de la carte de sorties numériques HBU
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Carte entrées/sorties numériques CCU20x
Numéro de la carte DI/DO
Position de la carte DI/DO
Numéro rack d'extension de la carte DI/DO
Réf. Client
Référence DI
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Carte d'entrées analogiques AIU21x
Carte d'entrées analogiques AIU20x
Numéro de la carte d'entrées analogiques
Position de la carte d'entrées analogiques
Numéro rack d'extension de la carte d'entrées analogiques
Réf. Client
Référence AI
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Type de Transducteur
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum du transducteur
Correspond à la valeur AI maximum du transducteur
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Module Analogique CT/VT TMU2x0
Numéro du module CT/VT
Position du module CT/VT
Acquisition TC
Acquisition TT
Courant Nominal
Tension Nominale
Modèle de carte CT/VT
Numéro rack d'extension de la carte CT/VT
Réf. Client
Référence AI
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Type d'entrée (U/I)
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum
Correspond à la valeur AI maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
NOM DE l'IED :
ENTREES NUMERIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée numérique de l'IED
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type MODBUS: Mapping Adresse;Bit nb DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU;;Mode de détection T103: Information nb;Adresse CommuneASDU;Mode de détection MODBUS: Fonction;;Mode de détection DNP3: ;;Mode de détection IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
SORTIES NUMERIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte de sortie numérique de l'IED
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type MODBUS: Mapping Adresse;Bit nb DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU;;Type d'Ordre T103: Information nb;Adresse Commune ASDU;Type d'Ordre MODBUS: Fonction;;Type d'Ordre DNP3: ;;Type d'Ordre IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Type (SPC=Simple/DPC=Double)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
ENTREES ANALOGIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée analogique de l'IED
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type; Unité de la MV MODBUS: Mapping Adresse;Format de la donnée DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU T103: Information nb;Adresse Commune ASDU; index dans l'ASDU MODBUS: Fonction DNP3: Non utilisé IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum
Correspond à la valeur AI maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
SORTIES ANALOGIQUES DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée analogique de l'IED
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse;Format de Sortie T103: ASDU nb;Fonction type;Format de Sortie MODBUS: Mapping Adresse DNP3: Adresse IEC: LD;LN T10X MASTER: Information Address
T101:Adresse Commune ASDU;;Type d'Ordre T103: Information nb;Adresse Commune ASDU;Type d'Ordre MODBUS: Fonction;;Type d'Ordre DNP3: ;;Type d'Ordre IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Common address ASDU;Data type
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum
Correspond à la valeur AI maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
FIN DES DONNEES DE l'IED
GROUPES ENTREES NUMERIQUES
Réf. Client
Référence du Groupes des DI
Données électriques
Description
Libellés
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Opérateur du Groupe
Fonction
Type (S=Simple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 (16 car)
Simple : Texte à l'état électrique = 0 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
ENTREES NUMERIQUES AUTOMATIQUES
Réf. Client
Référence interne DI
Données électriques
Description
Libellés/Etats
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Type (SPS=Simple/DPS=Double/MPS=Multiple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : label d'état (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique = 01 Multiple : Numéro d'état (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
SORTIES NUMERIQUES AUTOMATIQUES
Réf. Client
Référence interne DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Type (SPC=Simple/DPC=Double)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
ENTREES ANALOGIQUES AUTOMATIQUES
Réf. Client
Référence interne AI
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur AI minimum du transducteur
Correspond à la valeur AI maximum du transducteur
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Intégré par le Compteur
Est utilisé par la distribution automatique (GOOSE)
Automatisme d'origine (si existant)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
FIN DES DONNEES
SHEET : C364_Template
DESCRIPTION DU MiCOM C364
GROUPES DES ENTREES NUMERIQUES
ENTREES NUMERIQUES AUTOMATIQUES
SORTIES NUMERIQUES AUTOMATIQUES
ENTREES ANALOGIQUES AUTOMATIQUES
SHEET : Données de la Soustation
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DESCRIPTION DES DONNEES DE SOUS-STATION
Légende :
Nom de la Sous-station
Réservé à GE
Contrôle Uniquement
Sous-station
Non / Sous-station / Tranche / Spécifique
Génération automatique
Emplacement prenant le contrôle
SCADA & Local
SCADA / Local / SCADA & Local
Lecture seule
Passerelle
Ports utilisés (sur la passerelle)
SCADA 1
SCADA 2
SCADA 3
SCADA 4
Calculateur par défaut gérant la Sous-station
GROUPES DES DI DE LA SOUS-STATION
Réf. Client
Référence du Groupes des DI
Données électriques
Libellés
Description
Interface Scada
Groupes
Affichage Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Opérateur du Groupe
Fonction
Type (S=Simple)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 (16 car)
Simple : Texte à l'état électrique = 0 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Géré par le Calcultateur
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
Affichage LCD
Affichage HMI
Est un retour de position xPC
Acté sur xPC
Utilisé par ISaGRAF
Est utilisé par la distribution automatique (GOOSE)
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
FIN DES DONNEES
SHEET : Fonctions Electriques
Désignation :
Réf. GE :
Révision :
N° Document :
PROFILS ELECTRIQUES
Légende :
Réservé à GE
Lecture seule
Profils des entrées numériques simples (SPS)
Profils des entrées numériques systèmes simples (SPS)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la SPS
Condition de la Génération
Alarme audible
Alarme fugitive
Etat 1 confirmation du retard (x100 ms)
Etat 1 niveau de gravité
Etat 0 confirmation du retard (x100 ms)
Etat 0 niveau de gravité
Retard d'apparition de l'alarme (0-120 s)
Mode d'effacement
Paramètres d'impression de la SPS
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Paramètres d'Interverrouillage de la SPS
Reset des valeurs de l'interverrouillage
Niveau haut des valeurs de l'interverrouillage
Paramètres de traitement de la SPS
Libellé de l'état de basculement
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Traitement sur l'état Set
Traitement sur l'état Reset
Traitement sur l'état Ouvert
Traitement sur l'état Fermé
Traitement sur l'état de basculement
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état de basculement
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Masqué dû à la commande
Dépendance SBMC
Basculement du filtrage
Status initial
Reset forcé des valeurs de l'interverrouillage
Niveau haut forcé des valeurs de l'interverrouillage
Reset substitué des valeurs de l'interverrouillage
Niveau haut substitué des valeurs de l'interverrouillage
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage de basculement
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 1 (16 car)
Texte par défaut à l'état électrique = 0 (16 car)
Activer le FSS (forçage / substitution / suppression)
Profils des entrées numériques doubles (DPS)
Profils des entrées numériques systèmes doubles (DPS)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la DPS
Condition de la Génération
Alarme audible
Etat 10 niveau de gravité
Etat 10 confirmation de retard (x100 ms)
Etat 01 niveau de gravité
Etat 01 confirmation du retard (x100 ms)
Complémentarité [00] retard (x100 ms)
Complémentarité [11] retard (x100 ms)
Retard d'apparition de l'alarme (0-120 s)
Mode d'effacement
Paramètres d'impression de la DPS
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Paramètres d'Interverrouillage de la DPS
Valeur "bloqué" de l'interverrouillage
Valeur "ouvert" de l'interverrouillage
Valeur "fermé" de l'interverrouillage
Paramètres de traitement de la DPS
Libellé de l'état bloqué (=DBI 00)
Libellé de l'état indéfini (=DBI 11)
Libellé de l'état de basculement
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Valeur de l'interverrouillage Motion
Traitement sur l'état Ouvert
Traitement sur l'état Fermé
Traitement sur l'état bloqué
Traitement sur l'état indéfini
Traitement sur l'état de basculement
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état bloqué
Gravité d'alarme sur l'état indéfini
Gravité d'alarme sur l'état de basculement
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Alarme fugitive
Masqué dû à la commande
Dépendance SBMC
Basculement du filtrage
Status initial
Bloquage forcé des valeurs de l'interverrouillage
Ouverture forcée des valeurs de l'interverrouillage
Fermeture forcée des valeurs de l'interverrouillage
Bloquage substitué des valeurs de l'interverrouillage
Ouverture substituée des valeurs de l'interverrouillage
Fermeture substituée des valeurs de l'interverrouillage
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage de basculement
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeur de l'interverrouillage indéfini
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 10 (16 car)
Texte par défaut à l'état électrique = 01 (16 car)
Activer le FSS (forçage / substitution / suppression)
Profils des entrées numériques multiples (MPS)
Profils des entrées numériques systèmes multiples (MPS)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la MPS
Condition de la Génération
Alarme audible
Retard d'apparition de l'alarme (0-120 s)
Mode d'effacement
Paramètres d'impression de la MPS
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Paramètres d'Interverrouillage de la MPS
Valeur de l'interverrouillage à l'état 0
Valeur de l'interverrouillage à l'état 1
Valeur de l'interverrouillage à l'état 2
Valeur de l'interverrouillage à l'état 3
Valeur de l'interverrouillage à l'état 4
Valeur de l'interverrouillage à l'état 5
Valeur de l'interverrouillage à l'état 6
Valeur de l'interverrouillage à l'état 7
Valeur de l'interverrouillage à l'état 8
Valeur de l'interverrouillage à l'état 9
Valeur de l'interverrouillage à l'état 10
Valeur de l'interverrouillage à l'état 11
Valeur de l'interverrouillage à l'état 12
Valeur de l'interverrouillage à l'état 13
Valeur de l'interverrouillage à l'état 14
Valeur de l'interverrouillage à l'état 15
Paramètres de traitement de la MPS
Libellé de l'état 0
Libellé de l'état 1
Libellé de l'état 2
Libellé de l'état 3
Libellé de l'état 4
Libellé de l'état 5
Libellé de l'état 6
Libellé de l'état 7
Libellé de l'état 8
Libellé de l'état 9
Libellé de l'état 10
Libellé de l'état 11
Libellé de l'état 12
Libellé de l'état 13
Libellé de l'état 14
Libellé de l'état 15
Libellé de l'état indéfini
Libellé de l'état de basculement
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Traitement sur l'état 0
Traitement sur l'état 1
Traitement sur l'état 2
Traitement sur l'état 3
Traitement sur l'état 4
Traitement sur l'état 5
Traitement sur l'état 6
Traitement sur l'état 7
Traitement sur l'état 8
Traitement sur l'état 9
Traitement sur l'état 10
Traitement sur l'état 11
Traitement sur l'état 12
Traitement sur l'état 13
Traitement sur l'état 14
Traitement sur l'état 15
Traitement sur l'état indéfini
Traitement sur l'état de basculement
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état 0
Gravité d'alarme sur l'état 1
Gravité d'alarme sur l'état 2
Gravité d'alarme sur l'état 3
Gravité d'alarme sur l'état 4
Gravité d'alarme sur l'état 5
Gravité d'alarme sur l'état 6
Gravité d'alarme sur l'état 7
Gravité d'alarme sur l'état 8
Gravité d'alarme sur l'état 9
Gravité d'alarme sur l'état 10
Gravité d'alarme sur l'état 11
Gravité d'alarme sur l'état 12
Gravité d'alarme sur l'état 13
Gravité d'alarme sur l'état 14
Gravité d'alarme sur l'état 15
Gravité d'alarme sur l'état indéfini
Gravité d'alarme sur l'état de basculement
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Masqué dû à la commande
Dépendance SBMC
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage de basculement
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeur de l'interverrouillage indéfini
Activer le FSS (forçage / substitution / suppression)
Profils sorties numériques simples (SPC)
Profils sorties numériques systèmes simples (SPC)
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la SPC
Mode d'activation
Mode de sélection avant opération
Temps d'expiration pour la sélection avant opération [0-600s]
Temps d'expiration de l'exécution (si présent) [0..6000000] (x100ms)
Paramètres NACK d'alarme
Etat de l'alarme sur réception négative
Etat du Traitement sur réception Négative
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Paramètres d'Utilisation
Valeur "Off" d'utilisation
Valeur "On" d'utilisation
Paramètres d'Interverrouillage
Valeur "Off" de l'interverrouillage
Valeur "On" de l'interverrouillage
Durée de l'ordre (ms)
Durée de maintien (ms)
Paramètres d'impression de la SPC
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 1 (16 car)
Texte par défaut à l'état électrique = 0 (16 car)
Profils des sorties numériques doubles (DPC)
Profils des sorties numériques systèmes doubles (DPC)
Valeurs par défaut des Etats électriques
Texte par défaut à l'état électrique = 10 (16 car)
Texte par défaut à l'état électrique = 01 (16 car)
Paramètres d'impression de la DPC
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Durée d'ouverture (ms)
Durée de fermeture (ms)
Durée de maintien (ms)
Paramètres d'Utilisation
Valeur "Ouvert" d'utilisation 01
Valeur "Fermé" d'utilisation 10
Paramètres d'Interverrouillage
Valeur "Ouvert" de l'interverrouillage 01
Valeur "Fermé" de l'interverrouillage 10
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la DPC
Mode d'activation
Mode de sélection avant opération
Temps d'expiration pour la sélection avant opération [0-600s]
Temps d'expiration de l'exécution (si présent) [0..6000000] (x100ms)
Paramètres NACK d'alarme
Etat de l'alarme sur réception négative
Etat du Traitement sur réception Négative
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Profils SetPoint systèmes
Profils SetPoint
Paramètres d'impression de la SetPoint
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux du SetPoint
Mode d'activation
Mode de sélection avant opération
Temps d'expiration pour la sélection avant opération [0-600s]
Temps d'expiration de l'exécution (si présent) [0..6000000] (x100ms)
Paramètres NACK d'alarme
Etat de l'alarme sur réception négative
Etat du Traitement sur réception Négative
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Profils analogiques
Profils systèmes analogiques
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux de la MV
Nombre de décimales pour l'affichage [0-4]
Période d'acquisition courte (ms) [100 … 1000] pas de 100
Période d'acquisition longue (ms) [500 … 10000] pas de 500
3eme seuil bas (non ou % de la pleine échelle)
2eme seuil bas (non ou % de la pleine échelle)
1er seuil bas (non ou % de la pleine échelle)
1er seuil haut (non ou % de la pleine échelle)
2em seuil haut (non ou % de la pleine échelle)
3eme seuil haut(non ou % de la pleine échelle)
Graduation
Nombres de pentes [1-20]
Paramètres d'alarme associés à la MV
Condition de la Génération
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Paramètres de traitement de la MV
Libellé de l'état valide
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état supprimé
Libellé de l'état forcé
Libellé de l'état substitué
Libellé de l'état au-dessus de l'échelle
Libellé de l'état indéfini
Libellé de l'état circuit ouvert
Libellé de l'état seuil LLL
Libellé de l'état seuil LL
Libellé de l'état seuil L
Libellé de l'état seuil H
Libellé de l'état seuil HH
Libellé de l'état seuil HHH
Traitement sur l'état valide
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état supprimé
Traitement sur l'état forcé
Traitement sur l'état substitué
Traitement sur l'état au-dessus de l'échelle
Traitement sur l'état indéfini
Traitement sur l'état circuit ouvert
Traitement sur l'état LLL seuil
Traitement sur l'état LL seuil
Traitement sur l'état L seuil
Traitement sur l'état H seuil
Traitement sur l'état HH seuil
Traitement sur l'état HHH seuil
Valeur de l'interverrouillage valide
Valeur de l'interverrouillage sur l'auto vérification du défaut
Valeur de l'interverrouillage inconnu
Valeur de l'interverrouillage supprimé
Valeur de l'interverrouillage forcé
Valeur de l'interverrouillage substitué
Valeur de l'interverrouillage au-dessus de l'échelle
Valeur de l'interverrouillage indéfini
Valeur de l'interverrouillage circuit ouvert
Valeur de l'interverrouillage seuil LLL
Valeur de l'interverrouillage seuil LL
Valeur de l'interverrouillage seuil L
Valeur de l'interverrouillage seuil H
Valeur de l'interverrouillage seuil HH
Valeur de l'interverrouillage seuil HHH
Gravité d'alarme sur l'état valide
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état supprimé
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état substitué
Gravité d'alarme sur l'état au-dessus de l'échelle
Gravité d'alarme sur l'état indéfini
Gravité d'alarme sur l'état circuit ouvert
Gravité d'alarme sur l'état de seuil LLL
Gravité d'alarme sur l'état de seuil LL
Gravité d'alarme sur l'état de seuil L
Gravité d'alarme sur l'état de seuil H
Gravité d'alarme sur l'état de seuil HH
Gravité d'alarme sur l'état de seuil HHH
Calculé
Dépendance SBMC
Format graphique par défaut
Transmission sur événement
Bande morte
Paramètres d'impression de la MV
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Activer le FSS (forçage / substitution / suppression)
FIN DES DONNEES
SHEET : Informations Systemes
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATION SYSTEME DESCRIPTION
Passerelle
Ports utilisés (sur la passerelle)
Légende :
SCADA 1
Réservé à GE
SCADA 2
Génération automatique
SCADA 3
Lecture seule
SCADA 4
INFORMATION SYSTEME DESCRIPTION
Nom de la BAIE OI :
Interface IEC
Données électriques
Description
Libellés/Etats
Description
Interface Scada
Groupes
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Nom de l'IEC 61850 :
Nom de l'UCA2 IED :
Nom du SERVEUR d'E/S :
Nom du CLIENT d'E/S :
Nom du MiCOM C264 :
Nom de la PASSERELLE :
Nom du MiCOM C364 :
INFORMATION SYSTEME PASSERELLE
INFORMATION SYSTEME MiCOM C264
INFORMATION SYSTEME MiCOM C364
INFORMATION SYSTEME CLIENT E/S
INFORMATION SYSTEME SERVER E/S
INFORMATION SYSTEME UCA2 IED
INFORMATION SYSTEME IEC 61850
INFORMATION SYSTEME BAIE OI
Révision
Lien Equipement
Fonction
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 Multiple : pas utilisé MV : pas utilisé (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 Multiple : pas utilisé MV : pas utilisé (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Groupes de calculateur (séparateur ";")
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
LED MV : Non utilisé
xPS : Affichage LCD xPC : Contrôle LCD MV : Affichage LCD
xPS : Affichage HMI xPC : Contrôle HMI MV : Affichage HMI
xPS : Est un retour de position xPC xPC : Est activé par xPS MV : Archivé
Utilisé par ISaGRAF
xPS, MV : Est utilisé par la distribution automatique (GOOSE) xPC : Non utilisé
Nom du Point de Donnée (dans le modèle du SCE)
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Etat agence
Archivage auto
AIU statut
AIU statut
Etat imprimante backup
BIU statut
CCU statut
Archive centrale
Lien équipement
SPS de communication avec l'IED
Lien client OI
SPS de communication avec le SCADA
Top compteur
Couplage UCA2
SPS DB incohérente
contrôle basculement BD
Acquisition DI arrêtée
SPS fichier de perturbo prête
SPS fichier de perturbo prête
DIU statut
DOU statut
Etat horloge external
GHU statut
Etat ISAGRAF
DPS local/distant
DPC de contrôle Local/distant
SPS loc/distant
File du log
MV état calculateur principal
Mode équip.
DPC de contrôle du mode
Mode exploitation
DPS état imprimante
contrôle changement mode redondance
Statut changt redondance
Contrôle changement statut redond.
Mode redondance
SPS de Redondance
Client OI
SPS erreur logicielle
Synchronisation
SPS de Synchronisation de l'IED
DPC de control de test
TMU statut
SPS erreur watchdog
HBU statut
Etat agence
AIU statut
AIU statut
Archivage auto
Etat imp. backup
BIU statut
Perturbo prête
CCU statut
Archive centrale
Top compteur
SPS DB incoh.
ctrl bascul. BD
Lien équipement
Mode équip.
Acq DI arrêtée
DIU statut
DOU statut
Etat horloge ext
GHU statut
IED pert. prête
SPS com. IED
SPS Synchro. IED
Etat ISAGRAF
Etat ISAGRAF
DPC ctrl Loc/dis
DPS local/distant
SPS loc/distant
File du log
MV état princ.
DPC de contrôle du mode
Lien client OI
Mode exploitation
DPS état imprimante
ctrl mode red
ctrl statut red
Stat changt red.
Mode redondance
SPS de Redondance
SPS com. SCADA
SPS erreur soft.
Synchronisation
DPC de control de test
TMU statut
HBU statut
Couplage UCA2
SPS Watchdog
DPS état carte
Mode changt red.
LD DREC prêt
AOU statut
Buff Ov Gtw 1
Buff Ov Gtw 2
Buff Ov OI
Buff Ov OI Bck
All IED status
All rack status
Local alarm ack
Setting done
Setting disc.
Setting in prog.
Setting incoher.
Rack link status
Red.Status
IEC61850 gen SPS
IEC61850 gen DPS
IEC61850 gen MPS
IEC61850 gen SPC
IEC61850 gen DPC
IEC61850 gen MV
FIN DES DONNEES
SHEET : Fonctions Systèmes
Désignation :
Réf. GE :
Révision :
N° Document :
PROFILS SYSTEMES
Légende :
Réservé à GE
Lecture seule
FIN DES DONNEES
SHEET : SystemInformation_Template
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATION SYSTEME DESCRIPTION
Passerelle
Ports utilisés (sur la passerelle)
Légende :
SCADA 1
Réservé à GE
SCADA 2
Génération automatique
SCADA 3
Lecture seule
SCADA 4
FIN DES DONNEES
SHEET : Liste des Tranches
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATIONS SUR LES TRANCHES
Légende :
Réservé à GE
Lecture seule
Nom de la Tranche
Type de Tranche
Calculateur
Calculateur Redondant
Révision
FIN DES DONNEES
SHEET : Modèles T101
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA T101
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Temps de référence
Type de redondance
Adresse du lien
Adresse du lien redondant
Longueur de l'adresse du lien
Adresse commune de l'ASDU
Longueur de l'adresse commune de l'ASDU
Structure d'objet
Longueur maximale de la vue
Cause de longueur de transmission
Cycle Périodique de Mesure
Taille de Temps binaire
Cycle de balayage
Type de lien
Expriration de la trame de test (T3)
Temps d'expiration pour la sélection avant opération
Durée inter trame
Valeur de Qualité de l'état 'Jammed'
Valeur de Qualité de bascule xPS
Valeur de Qualité de l'état 'Inconnu'
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nombre maximum de fichiers SOE
Nb d'évenements dans le fichier SOE plein
Support du fichier de Perturbographie
Adresse du fichier de Perturbographie
Adresse du fichier de Perturbographie T103
Adresse du fichier de Perturbographie S20
Adresse du fichier de Perturbographie M300
Adresse du fichier de Perturbographie SlowWave
Adresse du fichier de Perturbographie FastWave
Nombre maximum de fichiers de perturbographie
Support du fichier de débordement de tampon
Adresse du fichier de débordement de tampon
Condition vide de débordement de tampon
Mode balancé
Mode balancé nb d'essais
Expiration du mode balancé
Séquence d'Information valeur de TS
Séquence d'Information valeur de TM
Séquence d'Information valeur de Compteur
Séquence d'Information écart d'adresse de séparation
SPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Etat Inversé
Balayage de fond
Enregistrement d'évènement
DPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Etat Inversé
Balayage de fond
Enregistrement d'évènement
MPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Utilisation du Bistring
Balayage de fond
Enregistrement d'évènement
SPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
DPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
MV Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée [1-255]
Format
Type de Cycle
Enregistrement d'évènement
Valeur Min
Valeur Max
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
Temps d'expiration pour la sélection avant opération [0-65535 s]
Compteur de Donnée de Type
Transmission d'évènements
Groupes [0-4] (0=non)
Prioritée [1-255]
Enregistrement d'évènement
FIN DES DONNEES
SHEET : Modèles DNP3
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA DNP3
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Temps de référence
Utilise TCP/IP
Adresse TCP/IP
Adresse du lien
Classe d'information numérique
Classe de valeur de mesure
Classe de compteur
Format de mesure
Mesure statique
Mesure évènementielle
Format de compteur
Compteur statique
Compteur évènementielle
Durée inter trame
Temps d'expiration pour la sélection avant opération
Message spontané actif
Classe de message spontané
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nb d'évenements dans le fichier SOE plein
SPS Donnée de Type
Transmission d'évènements
Etat Inversé
DPS Donnée de Type
Transmission d'évènements
Etat Inversé
MPS Donnée de Type
Transmission d'évènements
Utilisation du Bistring
SPC Donnée de Type
Type de commande SCADA
DPC Donnée de Type
Type de commande SCADA
MV Donnée de Type
Transmission d'évènements
Format
Valeur Min
Valeur Max
Défini comme compteur
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
Compteur de Donnée de Type
Transmission d'évènements
FIN DES DONNEES
SHEET : Modèles T104
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA T104
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Temps de référence
Adresse TCP/IP
Adresse commune de l'ASDU
Structure de l'adresse
Longueur maximale de la vue
Cycle Périodique de Mesure
Taille de Temps binaire
Cycle de balayage
Expiration de la Connexion (T0)
Expiration de l'APDU (T1)
Expiration de la Réception (T2)
Expriration de la trame de test (T3)
Taille de la fenêtre d'envoi d'acquis négatif
Taille de la fenêtre de réception d'acquis positif
Délai maximum de la Commande
Socket IP #1
Socket IP #2
Socket IP #3
Socket IP #4
Temps d'expiration pour la sélection avant opération
Valeur de Qualité de l'état 'Jammed'
Valeur de Qualité de bascule xPS
Valeur de Qualité de l'état 'Inconnu'
Switchover
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nombre maximum de fichiers SOE
Nb d'évenements dans le fichier SOE plein
Support du fichier de Perturbographie
Adresse du fichier de Perturbographie
Adresse du fichier de Perturbographie T103
Adresse du fichier de Perturbographie S20
Adresse du fichier de Perturbographie M300
Adresse du fichier de Perturbographie SlowWave
Adresse du fichier de Perturbographie FastWave
Nombre maximum de fichiers de perturbographie
Support du fichier de débordement de tampon
Adresse du fichier de débordement de tampon
Condition vide de débordement de tampon
SPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Etat Inversé
Balayage de fond
Enregistrement d'évènement
DPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Etat Inversé
Balayage de fond
Enregistrement d'évènement
MPS Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Utilisation du Bistring
Balayage de fond
Enregistrement d'évènement
SPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
DPC Donnée de Type
Type de commande SCADA
Temps d'expiration pour la sélection avant opération [0-65535 s]
MV Donnée de Type
Transmission d'évènements
Groupes [0-16] (0=non)
Prioritée
Format
Type de Cycle
Enregistrement d'évènement
Valeur Min
Valeur Max
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
Temps d'expiration pour la sélection avant opération [0-65535 s]
Compteur de Donnée de Type
Transmission d'évènements
Groupes [0-4] (0=non)
Prioritée
Enregistrement d'évènement
FIN DES DONNEES
SHEET : Modèles MODBUS
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA MODBUS
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Utilise TCP/IP
Adresse du lien
Durée inter trame
Parité
Support de fichier SOE
Adresse de fichier SOE
Format de fichier SOE
Nb d'évenements dans le fichier SOE
Nb d'évenements dans le fichier SOE plein
SPS Donnée de Type
Inversion
DPS Donnée de Type
Utilisation du Double Adressage
Inversion
MV Donnée de Type
Format
Précision [8-16]
Valeur Min
Valeur Max
SetPoint Donnée de Type
Format
Compteur de Donnée de Type
Format
FIN DES DONNEES
SHEET : Modèles OPC
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA OPC
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
OPC valeur pour 'Reset'
OPC valeur pour 'Set'
OPC valeur pour 'Jammed'
OPC valeur pour 'Open'
OPC valeur pour 'Closed'
OPC valeur pour 'Undefined'
OPC valeur pour 'Order Open' (set to 01)
OPC valeur pour 'Order Close' (set to 10)
OPC valeur pour 'Order Reset'
OPC valeur pour 'Order Set'
OPC Bool valeur pour 'Reset'
OPC Bool valeur pour 'Set'
OPC Bool valeur pour 'Jammed'
OPC Bool valeur pour 'Open'
OPC Bool valeur pour 'Closed'
OPC Bool valeur pour 'Undefined'
OPC Bool valeur pour 'Order Open' (set to 01)
OPC Bool valeur pour 'Order Close' (set to 10)
OPC Bool valeur pour 'Order Reset'
OPC Bool valeur pour 'Order Set'
OPC qualité pour 'SelfCheckFault'
OPC qualité pour 'Unknown'
OPC qualité pour 'Toggling'
OPC qualité pour 'Suppressed'
OPC qualité pour 'Forced'
OPC qualité pour 'Substituted'
OPC qualité pour 'Undefined' MPS MV Compteur
OPC qualité pour 'OverRange' MPS MV Compteur
OPC qualité pour 'OpenCircuit' MPS MV Compteur
OPC qualité pour 'LLLThreshold'
OPC qualité pour 'LLThreshold'
OPC qualité pour 'LThreshold'
OPC qualité pour 'HThreshold'
OPC qualité pour 'HHThreshold'
OPC qualité pour 'HHHThreshold'
OPC qualité pour 'Jammed' DPS
OPC qualité pour 'Undefined' DPS
OPC qualité pour 'Valid Set/Closed'
OPC qualité pour 'Valid Reset/Open'
SPS Donnée de Type
Historisation
Format
Etat Inversé
DPS Donnée de Type
Utilisation du Double Adressage
Historisation
Format
Etat Inversé
MPS Donnée de Type
Historisation
SPC Donnée de Type
Format
DPC Donnée de Type
Format
Utilisation du Double Adressage
FIN DES DONNEES
SHEET : Connectique
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT DES DONNEES
FIN DES DONNEES
SHEET : Présence des Colonnes
Cette FEUILLE est utilisée pour indiquer les cellules/colonnes qui sont :
- P : présentes dans toute les FEUILLES mais dont le contenu ne sera pas employé par les outils automatiques
- U : présentes dans toutes les FEUILLES et seront employées par les outils automatiques
- A : Absentes des FEUILLES
- PH :cachées dans toute les FEUILLES mais le contenu ne sera pas employée par les outils automatiques
- UH :cachées dans toutes les FEUILLES et seront employées par les outils automatiques
Réservé à GE
MiCOM CXXX DESCRIPTION
GROUPES DES ENTREES NUMERIQUES
ENTREES NUMERIQUES AUTOMATIQUES
SORTIES NUMERIQUES AUTOMATIQUES
ENTREES ANALOGIQUES AUTOMATIQUES
SHEET : Valeurs par Défaut
Cette FEUILLE est employée pour remplacer des valeurs par de nouvelles.
- placez l'ancienne valeur de paramètre dans la ligne "Ancienne valeur"
- placez la nouvelle valeur du paramètre dans la ligne "Nouvelle valeur"
- Il est possible d'employer des expressions régulières pour filtrer les "Anciennes valeurs".
? Tout caractère simple.
* Zéro caractère ou plus.
# Tout chiffre simple (0-9).
[charlist] Tout caractère simple dans charlist.
[!charlist] Tout caractère simple non compris dans charlist.
- un groupes d'un ou plusieurs caractères (charlist) inclus entre crochets ([ ]) peut être employé à
partir de n'importe quel caractère simple dans la chaine et pouvant inclure presque n'importe quel code de caractère,
y compris des chiffres.
- note : pour utiliser les caractères spéciaux tels le crochet ouvrant ([), le point d'interrogation (?), le signe de nombre (#),
et l'astérisque (*), les mettre entre crochets. Le crochet droit (]) ne peut pas être utilisé dans un Groupes
de sélection, mais peut être employé en dehors
- en employant un trait d'union (-) pour séparer les limites supérieures et inférieures de la liste, charlist peut
indiquer une liste des caractères. Par exemple, [ A-Z ] correspond a toutes les lettres majuscules de l'alphabet.
Les listes multiples sont incluses dans
les crochets sans délimiteurs.
Exemple:
aBBBa' est reconnu par l'expression régulière 'a*a'
F' est reconnu par l'expression régulière '[A-Z]'
F' n'est pas reconnu par l'expression régulière '[!A-Z]'
a2a' est reconnu par l'expression régulière 'a#a'
aM5b' est reconnu par l'expression régulière 'a[L-P]#[!c-e]'
BAT123khg' est reconnu par l'expression régulière 'B?T*'
CAT123khg' n'est pas reconnu par l'expression régulière 'B?T*'
Ancienne valeur
Nouvelle valeur
SHEET : Sélection Colonnes pour Copie
Cette FEUILLE est utilisée pour indiquer les cellules pour lesquelles le contenu sera copié dans une nouvelle version de Dataliste.
Les valeurs possibles sont :
- N : ne pas copier
- C : copier de toute façon (quand la ligne est significative)
- E : copier seulement si la cellule dans la nouvelle version est vide
SHEET : Matrix
Cette FEUILLE indique les cellules/colonnes utilisées pour définir des critères de comparaison.
Les valeurs possibles sont :
- P : présent dans tout la FEUILLE correspondante mais le contenu ne sera pas employé comme Critère de comparaison
- U : présent dans toute les FEUILLEs et sera utilisé pour établir un critère de comparaison
Utiliser ce cas de Matrix
SHEET : AIDE C264
ENTREES COMPTEUR DE l'IED
NOM DE l'IED
Réf. Client
Référence de la carte d'entrée Compteur de l'IED
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
T101: Information Adresse T103: ASDU nb;Fonction type MODBUS: Mapping Adresse;InputFormat DNP3: Adresse IEC: LD;LN T10X MASTER: Information Adresse
T101:Adresse Commune ASDU T103: Information nb;Adresse CommuneASDU MODBUS: Fonction DNP3: Non utilisé IEC: FC;Data Object;DataAttribute;CDC T10X MASTER: Adresse Commune ASDU;Data type
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Type du Compteur
Standard: Validation (ms);Invalidité (ms);Cumul (mn) Energy: Facteur d'echelle;Periode de transmission (mn)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Intègre la MV
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
ENTREES COMPTEUR AUTOMATIQUES
ENTREES COMPTEUR AUTOMATIQUES
ENTREES COMPTEUR AUTOMATIQUES
Réf. Client
Référence interne du compteur
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Type du Compteur
Standard: Validation (ms);Invalidité (ms);Cumul (mn) Energy: Facteur d'echelle;Periode de transmission (mn)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Intègre la MV
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
Profils Compteurs
Profils Compteurs systèmes
Nom de la fonction
Nom dans le SCE (13 char)
Paramètres généraux du Compteur
Energie équivalente à un pulse
Calculé
Dépendance SBMC
Format graphique par défaut
Paramètres d'alarme associés à la MV
Condition de la Génération
Alarme audible
Mode d'effacement
Retard d'apparition de l'alarme (0-120 s)
Paramètres de traitement du Compteur
Libellé de l'état valide
Libellé de l'état d'auto vérification du défaut
Libellé de l'état inconnu
Libellé de l'état forcé
Libellé de l'état au-dessus de l'échelle
Libellé de l'état indéfini
Traitement sur l'état valide
Traitement sur l'état d'auto vérification du défaut
Traitement sur l'état inconnu
Traitement sur l'état forcé
Traitement sur l'état au-dessus de l'échelle
Traitement sur l'état indéfini
Traitement sur l'état de forçage
Traitement sur l'état de substitution
Traitement sur l'état de suppression
Gravité d'alarme sur l'état valide
Gravité d'alarme sur l'état d'auto vérification du défaut
Gravité d'alarme sur l'état inconnu
Gravité d'alarme sur l'état forcé
Gravité d'alarme sur l'état au-dessus de l'échelle
Gravité d'alarme sur l'état indéfini
Paramètres d'impression du Compteur
Imprimer sur l'imprimante Fil de l'eau 1 :
Imprimer sur l'imprimante Fil de l'eau 2 :
Imprimer sur l'imprimante Journal de Bord 1 :
Imprimer sur l'imprimante Journal de Bord 2 :
Carte de sorties analogiques AOU20x
Numéro de la carte de sorties analogiques
Position de la carte de sortie analogiques
Numéro rack d'extension de la carte de sorties analogiques
Réf. Client
Référence AO
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur minimum
Correspond à la valeur maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
SORTIES SETPOINT AUTOMATIQUES
SORTIES SETPOINT AUTOMATIQUES
SORTIES SETPOINT AUTOMATIQUES
Réf. Client
Référence SetPoint
Données électriques
Description
Libellés
Interface Scada
Affichage Local
Spécial
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Numéro
Fonction
Unité
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Correspond à la valeur minimum
Correspond à la valeur maximum
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Affichage LCD
Affichage HMI
Archivé
Utilisé par ISaGRAF
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Automatisme d'origine (si existant)
Commentaires
SHEET : Modèles IEC61850
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA IEC 61850
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Adresse TCP/IP
FIN DES DONNEES
Carte DSP210
Numéro de la carte DSP210
Position de la carte DSP210
Numéro rack d'extension de la carte DSP210
Réf. Client
Référence DO
Données électriques
Description
Libellés
Interface Scada
Contrôle Local
Lien DI/DO
Automatisme
Modèle
Conf. Mng.
Interface IEC
Révision
Numéro d'armoire
Numéro d'étiquette
Position
Fonction
Type (SPC=Simple/DPC=Double/DS=Dual Switch)
Niveau de tension Nom court (16 car)
Tranche Nom court (16 car)
Module Nom court (16 car)
Nom long (35 car)
Simple : Texte à l'état électrique = 1 Double : Texte à l'état électrique = 10 (16 car)
Simple : Texte à l'état électrique = 0 Double : Texte à l'état électrique =01 (16 car)
Nom court (16 car)
SCADA 1 Adresse
SCADA 1 Type de donnée
SCADA 2 Adresse
SCADA 2 Type de donnée
SCADA 3 Adresse
SCADA 3 Type de donnée
SCADA 4 Adresse
SCADA 4 Type de donnée
Contrôle LCD
Contrôle HMI
A un retour de position xPS
Est activé par xPS
Utilisé par ISaGRAF
Relais
Nom de la Tranche (dans le modèle du SCE) ou Type de la Tranche
Nom du Module (dans le modèle du SCE) ou Type du Module
Nom du Point de Donnée (dans le modèle du SCE) ou Type du Point de Donnée
Utiliser
Addresse IEC Part 1 (IEC: LD;LN)
Addresse IEC Part 2 (IEC: FC;Data Object;DataAttribute;CDC)
Commentaires
Liens d'Automatismes (séparateur ";") (ajouter "<" si c'est une sortie)
SHEET : Liste des Automatismes
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATIONS SUR LES AUTOMATISMES
Légende :
Réservé à GE
Lecture seule
Numéro
Nom de l'Automatisme
Type d'Automatisme
Calculateur
Calculateur Redondant
Révision
Modèle
FIN DES DONNEES
SHEET : Liste des Liens IEC
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
INFORMATIONS SUR LES LIENS IEC
Légende :
Réservé à GE
Lecture seule
Clients \ Servers
Révision
FIN DES DONNEES
Sous-station 1
Sous-station 2
Sous-station 3
Sous-station 4
Sous-station 5
Sous-station 6
Sous-station 7
Sous-station 8
Sous-station 9
Sous-station 10
Sous-station 11
Sous-station 12
Sous-station 13
Sous-station 14
Sous-station 15
Sous-station 16
Sous-station 17
Sous-station 18
Sous-station 19
Sous-station 20
Sous-station 21
Sous-station 22
Sous-station 23
Sous-station 24
Sous-station 25
Sous-station 26
Sous-station 27
Sous-station 28
Sous-station 29
Sous-station 30
Sous-station 31
Sous-station 32
Sous-station 33
Sous-station 34
Sous-station 35
Sous-station 36
Sous-station 37
Sous-station 38
Sous-station 39
Sous-station 40
SHEET : Modèles SAS
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA SAS
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Adresse commune de l'ASDU
Longueur de l'adresse commune de l'ASDU
Structure d'objet
Longueur maximale de la vue
Cycle Périodique de Mesure
Taille de Temps binaire
SPS Donnée de Type
Etat Inversé
Envoyé lors de l'Interrogation Générale
DPS Donnée de Type
Etat Inversé
Envoyé lors de l'Interrogation Générale
MPS Donnée de Type
Envoyé lors de l'Interrogation Générale
MV Donnée de Type
Format
Type de Cycle
Valeur Min
Valeur Max
FIN DES DONNEES
SHEET : Modèles CDC Type II
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA CDC TYPE II
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Expiration de la Connexion (T0)
Valeur minimale de mesure
Valeur maximale de mesure
Valeur de mesure invalide
SPS Donnée de Type
Mode de transmission
Etat Inversé
DPS Donnée de Type
Mode de transmission
Etat Inversé
SPC Donnée de Type
Type de commande SCADA
DPC Donnée de Type
Type de commande SCADA
MV Donnée de Type
Valeur Min
Valeur Max
SetPoint Donnée de Type
Valeur Min
Valeur Max
FIN DES DONNEES
SHEET : Modèles GI74
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA GI74
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Adresse TCP/IP
NOM DU RESEAU
Port 1 : Adresse TE
Port 1 : Taille de bloc TE
Port 1 : Expiration du contrôle en ms
Port 1 : Fonction de contrôle HK
Port 1 : Bloc de contrôle HK
Port 1 : Mot de contrôle HK
Port 2 : Adresse TE
Port 2 : Taille de bloc TE
Port 2 : Expiration du contrôle en ms
Port 2 : Fonction de contrôle HK
Port 2 : Bloc de contrôle HK
Port 2 : Mot de contrôle HK
SPS Donnée de Type
Etat Inversé
Type de changement de propagation
DPS Donnée de Type
Etat Inversé
Type de changement de propagation
SPC Donnée de Type
Port de retour
DPC Donnée de Type
Port de retour
MV Donnée de Type
Type de la mesure
Type de changement de propagation
Type de l'unité
FIN DES DONNEES
SHEET : Modèles HNZ
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT SCADA HNZ
Légende :
Réservé à GE
Lecture seule
Nom de protocole SCADA
Nom court du SCADA (16 char)
Paramètres généraux du Protocole
Voie de communication principale
Voie de communication auxiliaire
Vitesse de transmission (bit/s)
Protocole
Temps de référence
Adresse de la Station
Numéro de Station réseau
RTU version base de donnée
Concatenation possible
Taille du Checksum (fcs)
Nombre max de tentatives
Durée inter trame
Taux d'Anticipation
Longueur maximale de la vue
Cycle de Mesure 1 (s)
Cycle de Mesure 2 (s)
Cycle de Mesure 3 (s)
Cycle de Mesure 4 (s)
Fifo : adresse de perte de donnée ou RTU Init (octet.bit)
Fifo : profondeur de tri chronologique (ms)
Fifo : condition vide
Fifo : délai de non activité, nouvelle tentative ou supervision (ms)
RTE : Periode d'analyse de qualité de ligne (s)
RTE : Message Bulle autorisé
RTE : Periode d'envoi d'un message Bulle (s)
RTE : Adresse de TOR Battante (octet.bit)
MV Donnée de Type
Cycle utilisé
Format
Structure de message
Conversion de la valeur originale
Envoyé sur variation
Mode de variation
Bande morte
SetPoint Donnée de Type
Type de commande SCADA
Format
Valeur Min
Valeur Max
FIN DES DONNEES
Unité par défaut
Unité par défaut pour le point de donnée
Unité par défaut
Unité par défaut pour le point de donnée
Unité par défaut
Unité par défaut pour le point de donnée
SHEET : Modèles T101 MAITRE
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT T101 MAITRE
Légende :
Réservé à GE
Lecture seule
Nom du protocole
Nom court(16 char)
Paramètres généraux du Protocole
Temps de référence
number of retries
station address size (bytes)
ASDU address size (bytes)
info address size (bytes)
taill cause de transmission (bytes)
acknowledgement time-out (x 100 ms)
synchronization cycle (x 10 s)
downgraded cycle (x 100 ms)
Type de lien
test frame time-out (s)
Durée inter trame
Vitesse de transmission (bit/s)
Legacy IED parameters
automatic disturbance
localisation for disturbance file
SPS Donnée de Type
DPS Donnée de Type
contact identifier
MPS Donnée de Type
SPC Donnée de Type
Type de commande
délai d'acquittement
DPC Donnée de Type
Type de commande
Type de contact
délai d'acquittement
MV Donnée de Type
output format
SetPoint Donnée de Type
Type de commande
output format
minimal value
maximal value
délai d'acquittement
Compteur de Donnée de Type
output format
FIN DES DONNEES
SHEET : Modèles T104 MAITRE
Désignation :
Réf. GE :
Révision :
N° Document :
Sous-Station Automation
Données de :
DEBUT T104 MAITRE
Légende :
Réservé à GE
Lecture seule
Nom du protocole
Nom court(16 char)
Paramètres généraux du Protocole
Référence horaire
Adresse TCP/IP
Adresse TCP/IP redondée
t0: délai d'établissement de connexion (s)
t1: délai d'envoi ou test d'APDU (s)
t2: délai d'acquittement si pas de données (s)
t3: délai d'envoi de trame de test en cas d'état en veille (s)
k: taille de la fenêtre des trames non transmises
w: taille de la fenêtre des trames reçues
Cycle de synchronisation (x 10s)
Durée inter trame
SPS Donnée de Type
DPS Donnée de Type
Identifiant contact
MPS Donnée de Type
SPC Donnée de Type
Type de commande
Délai acquittement
DPC Donnée de Type
Type de commande
Type de contact
Délai acquittement
MV Donnée de Type
Format de sortie
SetPoint Donnée de Type
Type de commande
Format de sortie
Valeur minimale
Valeur maximale
Délai acquittement
Compteur de Donnée de Type
Format de sortie
FIN DES DONNEES
Description of Remarks
Old Signal list
1. Distance relay - Missing internal signals related to functions such as AR, Weak-infeed, SOTF. 2. Addition of Differential Protection signals 3. Addition of Transformer phase wise Mechanical tripping signals 4. Addition of Centralized Busbar protection related signals. 5. Addition of tertiary transformer related protection signals. 6. Addition of Backup impedance protection signals for ICT & Reactor. 7. Addition of Directional OC & EF protection signals for ICT. 8. Addition of Mechanical trippings & alarms associated with REF. 9. Addition of NGR associated protection & CB Alarms 10. Addition of De-centralised - Busbar protection signals 11. Addition of Breaker failure protection initiation & Re-trip signals in standalone & centralized busbar protection 12. Addition of BCU – AR associated internal signals, TC phase wise, CSD related alarms, Bay wise measurements
IED MODEL
Time Synch
Project Name
BB7_P141_BVMT1
Auto generated
Port used (on gateway)
765KV SERVER M
BB7_P141_BVMT1
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Measurements;PriFouMMXU1
Measurements;PriFouMMXU1
Measurements;PriFouMMXU1
Measurements;PriFouMMXU1
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
BB7_P141_BVMT2
Auto generated
Port used (on gateway)
765KV SERVER M
BB7_P141_BVMT2
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Measurements;PriFouMMXU1
Measurements;PriFouMMXU1
Measurements;PriFouMMXU1
Measurements;PriFouMMXU1
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
BB7_P741_87CUA
Auto generated
Port used (on gateway)
765KV SERVER M
BB7_P741_87CUA
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
BB7_P741_87CUB
Auto generated
Port used (on gateway)
765KV SERVER M
BB7_P741_87CUB
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CftPhsPDIF1
Protection;CftPhsPDIF2
Protection;TrpPhsPDIF1
Protection;TrpPhsPDIF2
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;AlmGGIO1
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;DisPDIS5
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPSCH1
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
System;GosGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
Records;PriRFLO1
Records;PriRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;AlmGGIO1
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Control;PsbRPSB3
Control;PsbRPSB3
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS2
Protection;DisPDIS3
Protection;DisPDIS3
Protection;DisPDIS4
Protection;DisPDIS4
Protection;DisPDIS5
Protection;DisPDIS5
Protection;DisPSCH1
Protection;DisPSCH1
Protection;DisPSCH1
Protection;EfdPTOC1
Protection;EfdPTOC1
Protection;SofPSOF1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV1
Protection;VtpPhsPTOV2
System;GosGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
IED name
Customer Ref
Panel Number
Records;PriRFLO1
Records;PriRFLO1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
Protection;PTRC1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
Protection;PTRC1
Protection;SenRefPDIF1
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;AlmGGIO1
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
Protection;DisPDIS1
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
R707_P743_PU_A
Auto generated
Port used (on gateway)
765KV SERVER M
R707_P743_PU_A
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
Protection;CbfBbpRBRF3
Protection;CbfBbpRBRF4
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
R707_P743_PU_B
Auto generated
Port used (on gateway)
765KV SERVER M
R707_P743_PU_B
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
Protection;CbfBbpRBRF3
Protection;CbfBbpRBRF4
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF2
Protection;CbfBbpRBRF4
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;DifPDIF1
Protection;VhzWg1PVPH1
Protection;VhzWg1PVPH2
SPARE
System;OptGGIO1
System;OptGGIO1
SPARE
SPARE
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
System;PloGGIO1
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;HzrHvwPTOC1
Protection;HzrHvwPTOC1
Protection;HzrHvwPTOC1
Protection;VhzWg1PVPH1
Protection;VhzWg1PVPH2
SPARE
SPARE
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
Protection;PTRC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
Protection;OcpEI1PTOC1
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;PTRC1
Protection;SenRefPDIF1
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
R712_P743_PU_A
Auto generated
Port used (on gateway)
765KV SERVER M
R712_P743_PU_A
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
Protection;CbfBbpRBRF3
Protection;CbfBbpRBRF4
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
R712_P743_PU_B
Auto generated
Port used (on gateway)
765KV SERVER M
R712_P743_PU_B
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
Protection;CbfBbpRBRF1
Protection;CbfBbpRBRF2
Protection;CbfBbpRBRF3
Protection;CbfBbpRBRF4
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
B707_LINE
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Vbusbar RMS 2 value of the busbar voltage phase
cos ft : Power factor
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Freq (Line)
P total (MW)
Q total (Mvar)
cos ft : Power factor
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
Vbusbar RMS 2 value of the busbar voltage phase
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Vbusbar RMS 2 value of the busbar voltage phase
cos ft : Power factor
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
OIL FLOW SENSITIVE VALVE ALARM - RPH
LOW OIL FLOW/REVERSE FLOW - RPH
Customer Ref
Panel Number
OIL FLOW SENSITIVE VALVE ALARM - YPH
LOW OIL FLOW/REVERSE FLOW - YPH
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Vbusbar
Freq (Line)
P total (MW)
Q total (Mvar)
Vbusbar RMS 2 value of the busbar voltage phase
cos ft : Power factor
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
OIL FLOW SENSITIVE VALVE ALARM - BPH
LOW OIL FLOW/REVERSE FLOW - BPH
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
765KV SERVER M
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
SIGNAL
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
TIME SYNCHRONISATION ERROR
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CznPDIF1
Protection;BbpT01PDIF1
Protection;BbpT02PDIF1
** Any additional Signals as per Scheme & TS
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
Protection;CznPDIF1
Protection;BbpT01PDIF1
Protection;BbpT02PDIF1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Project Name
Auto generated
Port used (on gateway)
IED name
Customer Ref
Panel Number
System;LLN0
System;GosGGIO2
System;GosGGIO2
System;GosGGIO2
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
System;OptGGIO1
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
IED name
Customer Ref
Panel Number
SPARE
SPARE
SPARE
SPARE
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Customer Ref
Panel Number
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
We have submitted bid as individual firm.
We have submitted bid as joint venture of following firms :
2 or more
Attached copies of original documents defining :
The constitution or legal status;
The principal place of business;
The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
Attached original & copies of the following documents :
Written power of attorney of the signatory of the Bid to commit the bidder.
Joint Venture Agreement.
Particulars
For Other Partner(s)
Name of the Firm
Head Office/ Registered Office Address
Telephone
Contact Person
Place of Incorporation/ Registration
Year of Incorporation/ Registration
Nationality of
TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
Route-1: The Bidder must have designed, manufactured, tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least One (1) nos. GIS Circuit Breaker bay* of 715 kV or above voltage class in one (1) Substation or Switchyard and this bay must be in satisfactory operation# for at least Two (2) years as on the Originally scheduled last date of bid submission (soft copy) i.e 09.11.2026.
In case the Bidder is a Foreign Entity, following requirements shall be complied:
(i) If the bidder is submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, the bidder must, in its bid, propose an Indian Associate for executing the On-Shore Supply and On-Shore Services Contract, as per the provisions of bidding documents. The proposed Indian Associate must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays of 110KV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above For executing on-shore supply contract, the bidder in its bid, may alternatively propose its Indian Subsidiary or Group or Joint Venture Company as Indian Associate provided that the proposed Indian Associate has been registered in India (as per Companies Act 1956 or 2013 of India) for establishing manufacturing and testing facilities for 765kV GIS or above voltage level as on the date of bid opening mentioned above.
A) The Subsidiary or Group Company or a Joint Venture Company (JVC) of the bidder shall have manufacturing & testing facilities for 765kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned above. OR The bidder must have incorporated a Subsidiary or Group Company or a Joint Venture Company (JVC) as per Companies Act 1956 or 2013 of India, to manufacture 765kV or above voltage level GIS in India and it must have commenced the construction activities for establishment of 765kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening mentioned above. B) The bidder must supply at least one (1) no. 765kV GIS Circuit breaker bay* manufactured in the said facilities in India, for which Bidder shall furnish an undertaking (as per enclosed format in Volume-III of Bidding Document) along with the bid. C) Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from Indian works of its Subsidiary or Group Company or a Joint Venture Company (JVC) provided the Subsidiary/JVC/Group Company must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay should have been either supplied or type tested (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above.
Route-2: The Bidder, who has established manufacturing & testing facility in India for 715kV or above voltage level GIS but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that: a).1 The bidder must have manufactured at least one (1) no. 715KV or above voltage level GIS Circuit Breaker bay* based on the technological support of the Collaborator(s), provided that the Collaborator(s) meets the requirement stipulated in para 1.1 above. Further, the bidder must have either supplied or type tested the above GIS bay (as per IEC) as on the originally scheduled last date of bid submission(soft copy) mentioned above. OR a.2) i) The Bidder must have designed, manufactured, tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least Two (2) nos. GIS Circuit Breaker bays* of 345 kV or above voltage level in one (1) Substation or Switchyard and these bays must be in satisfactory operation# for at least Two (2) years as on the Originally scheduled last date of bid submission (soft copy) mentioned above a.2) ii) The Bidder must have technical collaboration for design, manufacture, test and supply 715kV or above voltage level GIS equipment with a GIS manufacture {Collaborator(s)} who meets the requirement stipulated in para 1.1 above. b) The bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the Collaborator(s)) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); ii. A confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 10 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 715kV or above voltage level GIS equipment in India.
Route-3: The Bidder, who has established manufacturing & testing facility in India for 715kV or above voltage level GIS as Subsidiary/JVC/Group company by its parent/principal but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that- a.1) The bidder must have manufactured at least one (1) no. 715KV or above voltage level GIS Circuit Breaker Bay* based on the technological support of the parent/principal company, provided that the parent/principal meets the requirement stipulated in para 1.1 above. Further, the bidder must have either supplied or type tested the above GIS bay (as per IEC) as on the originally scheduled last date of bid submission(soft copy) mentioned above. OR a.2) i) The Bidder must have designed, manufactured, tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least Two (2) nos. GIS Circuit Breaker bays* of 345 kV or above voltage level in one (1) Substation or Switchyard and these bays must be in satisfactory operation# for at least Two (2) years as on the Originally scheduled last date of bid submission (soft copy) mentioned above. a.2) ii) The Parent/Principal of Bidder must meet the requirement stipulated in para 1.1 above. b) The bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the parent/principal company) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); ii. A confirmation letter from the parent/principal company stating that they shall furnish performance guarantee for an amount of 10 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 715kV or above voltage level GIS equipment in India.
Route-4 In case, the bidder is not a GIS manufacturer, he shall also be considered provided: i.a. The bidder must have erected and commissioned at least two (02) nos. GIS circuit breaker bays of 345kV or above voltage class in one (01) GIS substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# as on the originally scheduled last date of bid Submission (soft copy) mentioned above. OR i.b. The bidder must have erected, tested and commissioned at least two (02) nos. AIS circuit breaker bays of 715 kV or above voltage class in one (01) substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# as on the originally scheduled last date of bid submission (soft copy) mentioned above. ii. The GIS must be offered from Indian manufacturer, who meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. QR Credential of proposed GIS Manufacturer(s) must be submitted along with the bid. iii. Bidder must submit a Manufacturer Authorization Form (MAF) from offered GIS manufacturer(s) (as per enclosed format in bidding document ) along with the Bid confirming that a legally enforceable Joint deed of Undertaking as per format enclosed at Section-VI, Volume-I of Bidding document shall be submitted at the time of signing of contract.
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
Voltage Level of GIS Substation commissioned under the Contract (Indicate 715KV or above class only)
No. of years, the above Substation have been in operation as on the originally scheduled last date of bid submission mentioned above
of Gas Insulated Switchgear (GIS) circuit breaker bays.
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
No. of GIS/AIS Circuit Breaker equipped bays under the contract
Name of the Collaborator
Whether bidder have established manufacturing and testing facilities in India for 715KV or above voltage level Gas Insulated Switchgear (GIS)
Whether 715KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder based on technological support of the collaborator have been supplied or Type tested
if Type tested details of Type test Report
Details of GIS supplied by them
Name of Contract Undertaken for manufacturing 715KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
No. of 715KV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 715KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
No. of Circuit Breaker bays under the contract
No. of years, the above facility have been in operation have been in operation as on the originally scheduled last date of bid submission mentioned above
Whether the Bidder have technical collaboration for design, manufacture, test and supply 715kV or above voltage level GIS equipment with above mentioned Collaborator
Name of the Bidder established as Subsidiary/JVC/Group company by its parent/principal Company
Name of the parent/principal Company
Whether bidder have established manufacturing and testing facilities in India for 715KV or above voltage level Gas Insulated Switchgear (GIS)
Whether 715KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bay manufactured by bidder have been supplied or Type tested based on Technological support of their Parent/ Principal Company
if Type tested details of Type test Report
Details of Gas Insulated Switchgear (GIS) Circuit Breaker Bays supplied by them
Name of Contract Undertaken for manufacturing 715KV or above voltage level Gas Insulated Switchgear (GIS) Circuit Breaker bays
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
No. of 715KV Gas Insulated Switchgear (GIS) Circuit Breaker bays manufactured under the contract (Indicate nos. of Gas Insulated Switchgear (GIS) Circuit Breaker equipped bays of 715KV or above voltage level, where circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs/Bushing CTs. GIS means SF6 Gas insulated Switchgear.)
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
No. of Circuit Breaker bays under the contract
No. of years, the above facility have been in operation have been in operation as on the originally scheduled last date of bid submission mentioned above
Name of Contract Undertaken
Contract Reference No. & Date of Award
No. of Circuit Breaker bays under the contract
No. of years, the above Gas Insulated Switchgear (GIS)/ Hybrid GIS /MTS CB bays are in operation as on the originally scheduled date of bid opening.
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm
Voltage Level of GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
Voltage Level of AIS Substation commsioned Under the Contract (Indicate 715kV or above class only)
FINANCIAL REQUIREMENTS :
Net Worth for last 3 financial years should be positive
Minimum Average Annual Turnover^ (MAAT) of the bidder for best three years i.e. 36 months out of last five financial years should be not less than Rs. 147.23 Crore or equivalent for 765kV GIS Extension Substation Package SS158.
Liquid Assets (LA) and/or evidence of access to or availability of credit facilities should be not less than Rs. 24.54 Crore or equivalent for 765kV GIS Extension Substation Package SS158.
Financial Qualification Data:
NET WORTH
Financial year
Turnover details:
Financial year
Liquid Assets
NET WORTH
Financial year
Turnover details:
Financial year
Liquid Assets
NET WORTH
Financial year
Turnover details:
Financial year
Liquid Assets
Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
Agreement entered into by the Joint Venture partners shall be submitted with the bid.
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above
In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
For Name of the Bidder
For Name of Other Partner-1 of JV
For Name of Other Partner-2 of JV
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm
Voltage Level of AIS/GIS Substation commissioned under the Contract (Indicate 345KV or above class only)
The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
For Name of Other Partner-2 of JV
Years preceding to the bid opening
In addition to the data/details furnished as above, the information available at ‘Information on Record’ (IoR) portal of POWERGRID may also be considered as our submission for purpose of QR compliance.
Printed Name :
Designation :
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
CC/NT/W-GIS/DOM/A02/26/13152
General guidelines for filling up the Attachments
Fill up only green shaded cells in the relevent attachments.
Attachments 3(QR), QR, 4, 4(A), 4(B), 5, 5(A), 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19 and Bid Form for 1st Envelope are included here.
Attachment 1: Bid Security : Not Applicable
Attachment 2: Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
Attachment 8: Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufacturer proposed to supply main items.
Attachment 14: Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
Attachment 18: Safety Pact
Attachment 20: KMP Declaration : Format enclosed in Volume-III of the Bidding Documents.
Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order, if applicable
Attachment 22: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
Attachment 23: Confirmation in regard to design & type test
Attachment 24: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
Attachment 25: Undertaking by the bidder regarding Compliance of DMI&SP policy
Attachment 26: Certification by the Bidder as per DoE Order in line with ITB Clause 2.1
Attachment 27: Bid Securing declaration
Attachment 28: Undertaking regarding submission of original/Hard copy part of the bid.
Attachment 29: Declaration by the bidder for ‘Code of Integrity for Public procurement’
Attachment 30: Declaration by the bidder for Acknowledgement and Acceptance of Supplier Code of Conduct
Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
Sole Bidder
2 or More
Sole Bidder
Attachment-3(JV) SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-3(QR) SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-QR SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Sole Bidder
upload scanned copies of original documents of Sole Bidder/ all Partner of the JV (if applicable) along with the bid on the portal.
The constitution or legal status;
The principal place of business;
The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
Whether bidder anticipate any change in legal structure/ ownership of their organisation at present
Important:
Bidders submitting their Bids in Joint Venture may note that they have to furnish the JV Agreement and Power of Attorney of JV in line with the provisions of Bidding Document alongwith Bid Security and Integrity Pact in physical form before deadline for submission of hard copy of documents.
Attach written Power of Attorney of the Signatory of the Bid (For sole bidder / Lead Partner of the JV) and signatories of other partners of the JV (Signing the JV Agreement / Attorney of the JV)
GENERAL INFORMATION
Particulars
Name of the Firm
Head Office/ Registered Office Address
Telephone
Contact Person
Place of Incorporation/ Registration
Year of Incorporation/ Registration
Nationality of
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
Case_Studies.pdf
TECHNICAL REQUIREMENTS
Technical Experience
{Reference para 1.1 of Annexure-A (BDS)}
The Bidder should have carried out the following as a prime contractor+: (a) Successfully completed$ physical construction of one (1) transmission line project of not less than 100 # kms of 345kV D/C or higher voltage class transmission line within the last seven (07) years as on the originally scheduled last date of bid submission (i.e. 12/05/2023) involving the following scope of work: i) Tower foundation, erection and stringing ii) Supply of tower & tower parts iii) Supply of line material viz. Conductor or Insulator or Hardware Fittings And (b) Designed and successfully tested/got successfully tested@ 345kV D/C or higher voltage class transmission line tower Note + : In case of works executed under a contract that had been awarded on a Joint Venture, the experience of individual Joint Venture partner shall be considered limited to the scope of that partner under the said contract. In case Bidder is a holding company, the technical experience referred to in clause 1.1 above shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case Bidder is a subsidiary of a holding company, the technical experience referred to in clause 1.1 above shall be of that subsidiary company only (i.e. excluding its holding companies). $ Successfully completed means issue of provisional or final taking over certificate (TOC) by the Employer to the contractor for the referred contract. @Designed and Successfully tested /got successfully tested means validation of design through testing and issue of test certificate thereof by the Test Agency to the contractor
Using the following format, each Bidder (individual firms ) is requested to list the contracts of a nature similar to the proposed contract for which the Bidder wishes to qualify, undertaken during the last seven (07) years. The information is to be summarised for each such contract separately.
Single Firm
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
(In Meters.)
(In Meters.)
(Yes/No)
Date of Completion of Contract
Details of documents furnished in the Bid, in support of the aforesaid data/ details/ information
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Voltage level of the Tower Designed (mention the voltage of the Tower)
Single Firm
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) & (ii) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
(In Meters.)
(In Meters.)
(Yes/No)
Date of Completion of Contract
Details of documents furnished in the Bid, in support of the aforesaid data/details/information
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Equipment Capabilities
{Reference para 1.2 of Annexure-A (BDS)}
The bidder should own or have access to the following key erection equipment: Minimum 6 no. of 15 Tonnes Capacity or #Minimum 3 no. of 24 Tonnes Capacity for Package TL01
The bidder is required to furnish data/details/information relevant to the stipulated QR as follows:
Capacity of Erection Equipment (in tonnes)
Whether Erection Equipments are Owned or leased
No. of Erection Equipments (Indicate separately no. of Erection Equipments)
Details of each of the TSEs stated at (i) above are to be furnished in the following table: {Use separate sheet, if required, and upload scanned copy}
If leased, whether Consent letter submitted alongwith the Bid?
Financial Position
{Reference para 1.2 of Annexure-A (BDS)}
In support of its ‘Financial Position’, in line with the above, the Bidder (Individual firm or all the JV partners in case of JV bidder) must provide the relevant information, alongwith documentary evidence, in the following format A:
Whether the bidder is a MSE (Yes/No) If Yes, please enclose supporting documents/documentary evidence
Whether the bidder is a Start-Up as defined by DIPP (Yes/No) If Yes, please enclose supporting documents/documentary evidence
For Partner – 1
Average Annual Turnover details:
Financial year
For Partner – 1
Net Worth (Paid Up Capital+Free Reserves and Surplus+Misc expenses to the extent not written off):
Financial year
For Partner – 1
Cash Flow from operations(Net Cash from Operating Activity+Dividend and Dividend Tax+Repayment of debt):
Financial year
For Partner – 1
Net Profit after Tax:
Financial year
Liquid Assets
Joint Venture (JV) Firms
In case a bid is submitted by a Joint Venture(JV) of two or more firms as partners, joint venture must comply with the following minimum criteria:
All the partners of the JV shall meet individually the financial position criteria given at Para 3.1 (a) above.
The lead partner of Joint Venture shall meet not less than 50 % of the Technical Experience criteria given at Para 2.1.1(i) above and not less than 40% of the Financial Position criteria given at Para 3.1 (b) & (c) above.
Each of the other partner(s) shall meet individually not less than 25% of the Technical Experience criteria given at Para 2.1.1(i) above or not less than 50% of Manufacturing facilities criteria given in para 2.2 above and not less than 25 % of the Financial position criteria given at Para 3.1 (b) & (c) above.
In case the JV intend to participate in the package proposing supply of tower parts from a manufacturer(s) then the manufacturer(s) shall meet the Manufacturing Facilities criteria given at para 2.2.1 above.
The joint venture must collectively meet the criteria of para 2.1.1, 2.2.1 and 3.1 above for which purpose the relevant figure of Technical Experience, Manufacturing Facilities, Equipment Capabilities and Financial Position (Para 3.1 (b) & (c) for each of the partners of the JV shall be added together.
In case of Joint Venture, the following conditions shall also apply:
the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners. (Form enclosed at Section-VI, Volume-I of Bidding Document)
one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in Section-VI of the Conditions of contract, Vol-I of the bidding document. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
all partners of the Joint Venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms, and a statement to this effect shall be included in the authorization mentioned under (ii) above as well as in the Bid Form and in the Contract Form (in case of a successful bid).
Agreement entered into by the Joint Venture partners shall be submitted with the bid.
In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the scanned copies of the corresponding documents are uploaded on the portal . Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents attached are to be indicated below:
The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.The Bidder shall also furnish documentary evidence/ declaration regarding Financial re-structuring of the company, if any
In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
F:\Orissa C\Rev\KRA.pdf
Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
For Partner – 1
Years preceding to the bid opening
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
Whether bidder organisation is underway of Financial re-structuring
Printed Name :
Designation :
Attachment-QR SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Sole Bidder
upload scanned copies of original documents of Sole Bidder/ all Partner of the JV (if applicable) along with the bid on the portal.
The constitution or legal status;
The principal place of business;
The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
Whether bidder anticipate any change in legal structure/ ownership of their organisation at present
Important:
Bidders submitting their Bids in Joint Venture may note that they have to furnish the JV Agreement and Power of Attorney of JV in line with the provisions of Bidding Document alongwith Bid Security and Integrity Pact in physical form before deadline for submission of hard copy of documents.
Attach written Power of Attorney of the Signatory of the Bid (For sole bidder / Lead Partner of the JV) and signatories of other partners of the JV (Signing the JV Agreement / Attorney of the JV)
GENERAL INFORMATION
Particulars
Name of the Firm
Head Office/ Registered Office Address
Telephone
Contact Person
Place of Incorporation/ Registration
Year of Incorporation/ Registration
Nationality of
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
Case_Studies.pdf
TECHNICAL REQUIREMENTS
Technical Experience
{Reference para 1.1 of Annexure-A (BDS)}
The Bidder should have carried out the following as a prime contractor+: (a) Successfully completed$ physical construction of one (1) transmission line project of not less than 100 kms of 345kV S/C or 345kV D/C or higher voltage class transmission line within the last seven (07) years as on the originally scheduled last date of bid submission (soft copy) i.e. 03/03/2025 involving the following scope of work: i) Tower foundation, erection and stringing ii) Supply of tower & tower parts iii) Supply of line material viz. Conductor or Insulator or Hardware Fittings Note + : In case of works executed under a contract that had been awarded on a Joint Venture, the experience of individual Joint Venture partner shall be considered limited to the scope of that partner under the said contract.
Using the following format, each Bidder (individual firms ) is requested to list the contracts of a nature similar to the proposed contract for which the Bidder wishes to qualify, undertaken during the last seven (07) years. The information is to be summarised for each such contract separately.
Single Firm
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
(In Meters.)
(In Meters.)
(Yes/No)
Date of Completion of Contract
Details of documents furnished in the Bid, in support of the aforesaid data/ details/ information
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Name of Contract Undertaken
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
(In Meters.)
(In Meters.)
(Yes/No)
Date of Completion of Contract
Voltage level of the Tower Designed (mention the voltage of the Tower)
Single Firm
Name of Contract Undertaken
Contract Reference No. & Date of Award
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) & (ii) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.2)
(In Meters.)
(In Meters.)
(Yes/No)
Date of Completion of Contract
Details of documents furnished in the Bid, in support of the aforesaid data/details/information
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Equipment Capabilities
{Reference para 1.2 of Annexure-A (BDS)}
The bidder should own or have access to the following key erection equipment: Minimum 6 no. of 15 Tonnes Capacity or #Minimum 3 no. of 24 Tonnes Capacity for Package TL01
The bidder is required to furnish data/details/information relevant to the stipulated QR as follows:
Capacity of Erection Equipment (in tonnes)
Whether Erection Equipments are Owned or leased
No. of Erection Equipments (Indicate separately no. of Erection Equipments)
Details of each of the TSEs stated at (i) above are to be furnished in the following table: {Use separate sheet, if required, and upload scanned copy}
If leased, whether Consent letter submitted alongwith the Bid?
Financial Position
{Reference para 1.2 of Annexure-A (BDS)}
In support of its ‘Financial Position’, in line with the above, the Bidder (Individual firm or all the JV partners in case of JV bidder) must provide the relevant information, alongwith documentary evidence, in the following format A:
Whether the bidder is a MSE (Yes/No) If Yes, please enclose supporting documents/documentary evidence
Whether the bidder is a Start-Up as defined by DIPP (Yes/No) If Yes, please enclose supporting documents/documentary evidence
For Partner – 1
Average Annual Turnover details:
Financial year
For Partner – 1
Net Worth (Paid Up Capital+Free Reserves and Surplus+Misc expenses to the extent not written off):
Financial year
For Partner – 1
Cash Flow from operations(Net Cash from Operating Activity+Dividend and Dividend Tax+Repayment of debt):
Financial year
For Partner – 1
Net Profit after Tax:
Financial year
Liquid Assets
Joint Venture (JV) Firms
In case a bid is submitted by a Joint Venture(JV) of two or more firms as partners, joint venture must comply with the following minimum criteria:
All the partners of the JV shall meet individually the financial position criteria given at Para 3.1 (a) above.
The lead partner of Joint Venture shall meet not less than 50 % of the Technical Experience criteria given at Para 2.1.1(i) above and not less than 40% of the Financial Position criteria given at Para 3.1 (b) & (c) above.
Each of the other partner(s) shall meet individually not less than 25% of the Technical Experience criteria given at Para 2.1.1(i) above or not less than 50% of Manufacturing facilities criteria given in para 2.2 above and not less than 25 % of the Financial position criteria given at Para 3.1 (b) & (c) above.
In case the JV intend to participate in the package proposing supply of tower parts from a manufacturer(s) then the manufacturer(s) shall meet the Manufacturing Facilities criteria given at para 2.2.1 above.
The joint venture must collectively meet the criteria of para 2.1.1, 2.2.1 and 3.1 above for which purpose the relevant figure of Technical Experience, Manufacturing Facilities, Equipment Capabilities and Financial Position (Para 3.1 (b) & (c) for each of the partners of the JV shall be added together.
In case of Joint Venture, the following conditions shall also apply:
the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners. (Form enclosed at Section-VI, Volume-I of Bidding Document)
one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in Section-VI of the Conditions of contract, Vol-I of the bidding document. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
all partners of the Joint Venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms, and a statement to this effect shall be included in the authorization mentioned under (ii) above as well as in the Bid Form and in the Contract Form (in case of a successful bid).
Agreement entered into by the Joint Venture partners shall be submitted with the bid.
In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the scanned copies of the corresponding documents are uploaded on the portal . Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents attached are to be indicated below:
The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.The Bidder shall also furnish documentary evidence/ declaration regarding Financial re-structuring of the company, if any
In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
F:\Orissa C\Rev\KRA.pdf
Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
For Partner – 1
Years preceding to the bid opening
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
Whether bidder organisation is underway of Financial re-structuring
In addition to the data/details furnished as above, the information available at ‘Information on Record’ (IoR) portal of POWERGRID may also be considered as our submission for purpose of QR compliance.
Printed Name :
Designation :
Attachment-4 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Equipments & Materials produced in [Name of countries]
Printed Name :
Designation :
country.
Attachment-4(A) SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
For Equipment
Printed Name :
Designation :
Attachment-4(B) SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-5 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Item Description
Nationality
FALSE
Item Description
Address
Printed Name :
Designation :
Annexure I to Attachment-5 SS-158
Item Description
Nationality
Printed Name :
Designation :
Annexure I to Attachment-5 SS-158
Item Description
Nationality
Printed Name :
Designation :
Attachment-5(A) SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Item Description
Category
Printed Name :
Designation :
Attachment-6 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Reference clause in the Specifications
Printed Name :
Designation :
Annexure I toAttachment-6 SS-158
Reference clause in the Specifications
Printed Name :
Designation :
Attachment-7 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-9 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Description of Work
Gairatganj-Pathari 132kV DCDS line
(b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
Detailed Engineering and drawing submission
Procurement of equipment/ components & assembly
Type Tests
Manufacturing
Shipments & Delivery
Establishment of site office
Installation at Site
Testing & Pre-commissioning
Trial Operation
Printed Name :
Designation :
Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Attachment-10 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-11 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of the person with designation in POWERGRID
Printed Name :
Designation :
Attachment-12 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of Materials/Labour
Circuit Breaker
Raw Material
Labour
Capacitive Voltage Transformer
Raw Material
Labour
Current Transformer
Raw Material
Labour
Isolators
Raw Material
Labour
Surge Arrester
Raw Material
Labour
PVC/XLPE Insulated Power and Control Cable
a=PVC/XLPE Compound
Published Price of Metal
IEEMA
IEEMA
Weight in MT of Metal per kM (Size wise)
Substation Structures
Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
Raw Materials
a=Structural steel
b=Electrolytic Zinc
L=Labour
For Installation Price Component
Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’ )
Labour, coefficient l =
Supply & Placement of Reinforcement Steel
High Speed Diesel, coefficient (HSD) a=
Labour, coefficient I=
Manufacture of Basic Metals b=
For Concereting
High Speed Diesel, coefficient (HSD) a=
Labour, coefficient I=
Manufacture of cement, lime and plaster b=
Cutting, shaping and finishing of stone c=
Printed Name :
Designation :
Attachment-13 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-14 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
The requisite format of Integrity Pact is getting generated automatically and displayed here below.
Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
For further details bidders may please refer ITB Clause 9.3 (o).
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 1 of 8
POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC/PC Act, or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID's Rules.
The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution :
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 2 of 8
The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or the execution of the contract.
The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC/IPC Act.
The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 3 of 8
If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban/blacklist the Bidder/Contractor in line with POWERGRID's policy for "Black-Listing of Firms/Banning of Business". The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the postion of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for the forfeiture of the Bid Guarantee under the Bid.
If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 4 of 8
If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID's policies.
POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 5 of 8
The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He/She reports to the Chairman-cum-Managing Director, POWERGRID.
The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his/her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
POWERGRID will provide to the IEMs information as sought by him/her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on 'Non-Disclosure of Confidential Information' and of 'Absence of Conflict of Interest'. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and rescue himself/herself from that case
As soon as the IEM notices, or believes to notice, a violation of this agreement, he/she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC/IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 6 of 8
While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
The word ‘IEM’ would include both singular and plural.
This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration/Conciliation clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral/Conciliation or judicial proceedings (arising out of the arbitral/Conciliation proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 7 of 8
Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal)
Designation :
Witness 1 :
Designation :
Witness 2 :
Designation :
Page 8 of 8
The requisite format of Integrity Pact is getting generated automatically and displayed here below.
Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
For further details bidders may please refer ITB Clause 9.3 (0).
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 1 of 8
POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles during its participation in the tender process and during the contract execution:
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 2 of 8
The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 3 of 8
If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 4 of 8
If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 5 of 8
The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case
As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 6 of 8
While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
The word ‘IEM’ would include both singular and plural.
This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration/Conciliation clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral/conciliation or judicial proceedings (arising out of the arbitral/conciliation proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 7 of 8
Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal)
Designation :
Witness 1 :
Designation :
Witness 1 :
Designation :
Page 8 of 8
Attachment-15 SS-158
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
Name of the Supplier/ Contractor in whose favour payment is to be made
Address with PIN Code and State
Status – Company/others
Permanent Account (PAN) No.
GSTIN Numbers
GSTIN in the Sates/UT from where the supply of goods take place
GSTIN number
GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
GSTIN number
UTTAR PRADESH
PF Regional Office covered (with Address)
Name of Contact Person
Contact Details
Bank Details for Electronic Payment
Current Account
9 digit MICR code printed at bottom in middle, next to cheque no.
IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
Attachment-15 SS-158
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
Name of the Supplier/ Contractor in whose favour payment is to be made
Address with PIN Code and State
Status – Company/others
Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement poliy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidenec is to be attached. Please refer remarks at the end of the attachment.
If 3.(b) is 'Yes' please mention whether you are (Proprietary MSE/Partnership MSE/Private Limited Company) owned by SC/ST entrepreneurs.
Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
Permanent Account (PAN) No.
GSTIN Numbers
GSTIN in the Sates/UT from where the supply of goods take place
GSTIN number
GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
GSTIN number
PF Regional Office covered (with Address)
Name of Contact Person
Contact Details
Bank Details for Electronic Payment
Current Account
9 digit MICR code printed at bottom in middle, next to cheque no.
IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
Printed Name :
Designation :
Attachment-16 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
The Bidder shall furnish
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
The Bidder should accordingly also provide the following information/documents
Details of Banker:
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Letter Ref.
Details of Provident Fund Code Number of the Bidder
Litigation History
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Name of client, cause of litigation/arbitration and matter in dispute
Details regarding previous transgressions of Integrity Pact
Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Name of client
OTHER INFORMATION
Current Contract Commitments of works in progress
Value of outstanding work (Rs.)
Financial Data:
Actual (Previous five years)
Printed Name :
Designation :
Attachment-16
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
The Bidder shall furnish
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
The Bidder should accordingly also provide the following information/documents
Details of Banker:
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Letter Ref.
Litigation History
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Name of client, cause of litigation/arbitration and matter in dispute
OTHER INFORMATION
Current Contract Commitments of works in progress
Value of outstanding work (Rs.)
Financial Data:
Actual (Previous five years)
Printed Name :
Designation :
Attachment-16
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
The Bidder shall furnish
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
The Bidder should accordingly also provide the following information/documents
Details of Banker:
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Letter Ref.
Litigation History
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Name of client, cause of litigation/arbitration and matter in dispute
OTHER INFORMATION
Current Contract Commitments of works in progress
Value of outstanding work (Rs.)
Financial Data:
Actual (Previous five years)
Printed Name :
Designation :
Attachment-17 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Printed Name :
Designation :
Attachment-17 SS-158
Gurgaon (Haryana) - 122001
Name of the person with designation in POWERGRID
Printed Name :
Designation :
Attachment-17 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of the person with designation in POWERGRID
Printed Name :
Designation :
Attachment-18 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
The requisite format of Safety Pact is getting generated automatically and displayed here below.
Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other six pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
For further details bidders may please refer ITB Clause 9.3 (s).
having its Registered Office at
(Signature)
(For & On behalf of Bidder/ Contractor)
Page 1 of 6
POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time.
POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
(Signature)
(For & On behalf of Bidder/ Contractor)
Page 2 of 6
POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by them by providing safe methods of work, working conditions and Tools & Plants for human safety.
The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of their Sub-contractors for safety awareness during construction works being executed by them.
The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
(Signature)
(For & On behalf of Bidder/ Contractor)
Page 3 of 6
The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at height and also medically fit for work at height are deployed for work at height in the Projects executed by them.
The Bidder / Contractor shall ensure daily before starting the work that their site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / support shall be provided to the victims / injured till they are completely fit to return to work.
The Bidder / Contractor shall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
(Signature)
(For & On behalf of Bidder/ Contractor)
Page 4 of 6
The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
The Bidder / Contractor accepts the provisions regarding safety, including payment of any sums to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration/Conciliation clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
(Signature)
(For & On behalf of Bidder/ Contractor)
Page 5 of 6
Signature
(For & On behalf of Bidder/ Contractor)
(Office Seal)
Designation :
Witness 1 :
Designation :
Witness 2 :
Designation :
Page 6 of 6
Attachment-19 SS-158
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
CC/NT/W-GIS/DOM/A02/26/13152
thirteen
fourteen
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
Enter details here.
Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently).
We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
Attachments to the Bid Form (First Envelope)
Pay Order
Not Applicable
Enter details here.
Online Payment
A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14.
The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR).
The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B.
The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein.
The details of Alternative Bids (Not Applicable)
Manufacturer’s Authorisation Forms.
Work Completion Schedule.
Guarantee Declaration.
Information regarding ex-employees of Employer in our firm.
Price Adjustment Data
Declaration regarding Social Accountability.
Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
Option for Interest Bearing Advance(s) (Initial Advance and/or Engineering Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Additional Information.
Declaration for tax exemptions, reductions, allowances or benefits
Safety Pact
Declaration.
Declaration of Key Managerial Person jointly with Power of Attorney holder
Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order and MoP Order, if applicable
Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
Confirmation in regard to Type Test (to be furnished in case bidder is proposing to qualify through Note-4 under Route-1 of QR).
Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1 (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture)
Affidavit of Self certification regarding Domestic Value Addition in Iron &Steel Products in line with DMI&SP policy
Certification by the Bidder as per DoE Order in line with ITB Clause 2.1(In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture)
Bid Securing Declaration to be submitted by the Bidder.
Undertaking regarding submission of original/Hard copy part of the bid
Declaration by the bidder for ‘Code of Integrity for Public procurement’
Declaration by the bidder for Acknowledgement and Acceptance of ‘Supplier Code of Conduct’
We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
We are aware that the Price Schedules do not generally give a full description of the Work to be performed under each item and we shall be deemed to have read the Technical Specifications and other sections of the Bidding Documents and Drawings to ascertain the full scope of Work included in each item while filling-in the rates and prices in Second Envelope.
We declare that as specified in Clause 11.5, Section-II:ITB, Vol.-I of the Bidding Documents, prices quoted by us in the Price Schedules in Second Envelope shall be subject to Price Adjustment during the execution of Contract in accordance with Appendix-2 (Price Adjustment) to the Contract Agreement.
We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
We further understand that notwithstanding 4.0 above, in case of award on us, you shall also bear and pay/reimburse to us, GST in respect of supplies by us to you, imposed on the Plant & Equipment including Mandatory Spare Parts to be incorporated into teh facilities Type Test charges for Type test to be conducted specified in Schedule No. 1, Installation Services specified in Schedule No. 3 and Charges for Training to be imparted specified in Schedule No. 4 of of the Price Schedule in Second Envelope, by the Indian Laws.
We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
Construction of the Contract
We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
Appendix 2 to Form of Contract Agreement
We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
We agree to abide by this bid for a period of Six (06) months after the last date of bid submission as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
We understand that you are not bound to accept the lowest or any bid you may receive.
Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Amount and Currency
# (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
* (applicable for MSE only) We are a Micro and Small Enterprise (MSE) registered with………….., a designated Authority of GoI under the Public Procurement Policy for MSEs Order, 2012, Notification dated 01/06/2020 and 26/06/2020 including subsequent amendments, read in conjunction with related notifications issued from time to time for such enterprises. Delete if not applicable
We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
We, hereby, declare that we, along with our associate/ collaborators/ sub-contractors/ sub-vendors/consultants/ service providers shall strictly adhere to the POWERGRID Whistle Blower and Fraud Prevention Policy. We, along with our associate / collaborator / subcontractors / sub-vendors / consultants / service providers shall observe the highest standard of ethics and shall not indulge or allow anybody else working in our organization to indulge in fraudulent activities during execution of the contract and would immediately apprise the Employer about any fraud or suspected fraud as soon as it comes to our notice.
Printed Name :
Designation :
Printed Name :
Designation :
Attachment 2(SS-158)
Three
Seven
Eight
Eleven
Twelve
Thirteen
Fourteen
Fifteen
Sixteen
Seventeen
Eighteen
Nineteen
Twenty
Twenty One
Twenty Two
Twenty Three
Twenty Four
Twenty Five
Twenty Six
Twenty Seven
Twenty Eight
Twenty Nine
Thirty
Thirty One
Thirty Two
Thirty Three
Thirty Four
Thirty Five
Thirty Six
Thirty Seven
Thirty Eight
Thirty Nine
Forty
Forty One
Forty Two
Forty Three
Forty Four
Forty Five
Forty Six
Forty Seven
Forty Eight
Forty Nine
Fifty
Fifty One
Fifty Two
Fifty Three
Fifty Four
Fifty Five
Fifty Six
Fifty Seven
Fifty Eight
Fifty Nine
Sixty
Sixty One
Sixty Two
Sixty Three
Sixty Four
Sixty Five
Sixty Six
Sixty Seven
Sixty Eight
Sixty Nine
Seventy
Seventy One
Seventy Two
Seventy Three
Seventy Four
Seventy Five
Seventy Six
Seventy Seven
Seventy Eight
Seventy Nine
Eighty
Eighty One
Eighty Two
Eighty Three
Eighty Four
Eighty Five
Eighty Six
Eighty Seven
Eighty Eight
Eighty Nine
Ninety
Ninety One
Ninety Two
Ninety Three
Ninety Four
Ninety Five
Ninety Six
Ninety Seven
Ninety Eight
Ninety Nine
One Hundred
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
Spec No: CC/NT/W-GIS/DOM/A02/26/13152
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
Fill up only green shaded cells in Sch-1, Sch-2, Sch-3 and Bid Form 2nd Envelope.
All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
While filling up the worksheets following may please be observed :
Fill up only green shaded cells.
Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
Do not link any cell of this work book with any other work book.
Do not use copy & paste or cut & paste options for filling up the data.
Do not reformat any of the cell of the work book.
This Workbook consists of following worksheets :
Fill up names and address of the Sole Bidder and /or Joint Venture.
Fill up date in dd-mmm-yyyy format from drop down menu.
Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
Total amount shall get calculated automatically.
Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
Total amount shall get calculated automatically.
Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
Total amount shall get calculated automatically.
Not applicable, hence no cell is required to be filled up.
No cell is required to be filled in by the bidder in this worksheet.
Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
No cell is required to be filled in by the bidder in this worksheet.
Not applicable, hence no cell is required to be filled up.
Total of this Sch-7 shall automatically appear in Sch-1.
Fill up ref. no. as bidder's ref no. of this letter.
This letter shall consider the net price as per Sch-6 (After Discount).
Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
Fill up additional information as required.
Sole Bidder
2 or More
Sole Bidder
Schedule - 1
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage lum-sum
Amount after Discount (Rs.)
SS158_Nalagarh 220kV GIS Bay
Not Applicable
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Printed Name :
Schedule - 1
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Direct
Bought-Out
Activity Description
10x500MVA, 765kV ICTs at Bidar PS
765/400/33kV Autotransformer
765/400/33kV Autotransformer
765/400/33kV Autotransformer
765/400/33kV Autotransformer
765/400/33kV Autotransformer
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Mandatory Spares
Not Applicable
Specify amount of GST on the transaction between the Contractor and the Employer.
Printed Name :
Schedule - 1
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Direct
Bought-Out
Item Description
Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Printed Name :
Schedule - 2 Dis
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage Discount
Amount after Discount (Rs.)
Description
Printed Name :
Schedule - 2
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Direct
SS158_Nalagarh 220kV GIS Bay
Diameter Completion at Sasaram
Printed Name :
Schedule - 3
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage lum-sum
Amount after Discount (Rs.)
Diameter Completion at Sasaram
In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Printed Name :
Schedule - 3
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage lum-sum
Amount after Discount (Rs.)
Description
Printed Name :
Schedule-4
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Designation :
Schedule - 5
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Item Nos.
TOTAL GST ON GOODS
TOTAL GST ON SERVICES
Designation :
Schedule - 6
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Description
TOTAL SCHEDULE NO. 1
TOTAL SCHEDULE NO. 2
TOTAL SCHEDULE NO. 3
TOTAL SCHEDULE NO. 4
TOTAL SCHEDULE NO. 5
TOTAL SCHEDULE NO. 7
Designation :
Schedule - 5
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Item Nos.
TOTAL GST ON GOODS
TOTAL GST ON SERVICES
Designation :
Schedule - 6 After Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Description
TOTAL SCHEDULE NO. 1
TOTAL SCHEDULE NO. 2
TOTAL SCHEDULE NO. 3
TOTAL SCHEDULE NO. 4
TOTAL SCHEDULE NO. 5
TOTAL SCHEDULE NO. 7
Designation :
Schedule 7
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage Discount
Designation :
Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage Discount
Description of Test
Designation :
Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Description of Test
Schedule 7
As per Lum-sum
AS per Percent
Total Discount
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Multipackage Discount
HSN Code
Designation :
Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Description of Test
Letter of Discount
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
Eq Weightage of Rs/ %
Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1, Sch-2 & Sch-3] In Rs.
Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1, Sch-2 & Sch-3] In Percent (%)
Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
In Percent (%)
In Percent (%)
In Percent (%)
In Percent (%)
In Percent (%)
We hereby offer Multi-package discount as given below:
Designation :
Bid Form 2nd Envelope
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. 0 or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents.
Price Schedules
In line with the requirements of the Bidding documents, we enclose herewith the following Price Schedules, duly filled - in as per your proforma:
Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges.
Local Transportation, In-transit Insurance, loading and unloading
Installation Charges.
Training charges for training to be imparted. (Not Applicable)
Taxes and Duties
Grand Summary [Schedule 1to 5]
Break-Up of Type Test Charges (Not Applicable)
We are aware that the Price Schedules do not generally give a full description of the Work to be performed under each item and we shall be deemed to have read the Technical Specifications and other sections of the Bidding Documents and Drawings to ascertain the full scope of Work included in each item while filling-in the rates and prices. We agree that the entered rates and prices shall be deemed to include for the full scope as aforesaid, including overheads and profit.
We declare that as specified in Clause 11.5, Section-II:ITB, Vol.-I of the Bidding Documents, prices quoted by us in the Price Schedules shall be subject to Price Adjustment during the execution of Contract in accordance with Appendix-2 (Price Adjustment) to the Contract Agreement.
We understand that, if POWERGRID becomes successful bidder in BPC bidding and we emerge as successful bidder in the subject Package, then prior to placing the award onto us for the subject Package, POWERGRID will proportionately adjust the unit prices of all the items in our bid by multiplying with a factor as defined at ITB sub-clause 27.7 b) in case the time gap between the deadline for bid submission for the subject Package and the deadline for RfP bid submission for POWERGRID in BPC bidding is more than 90 days (excluding the date of bid submission for subject Package).
We understand that in the price schedules, where there are errors between the total of the amounts given under the column for the price Breakdown and the amount given under the Total Price, the former shall prevail and the latter will be corrected accordingly. We further understand that where there are discrepancies between amounts stated in figures and amounts stated in words, the amount stated in words shall prevail. Similarly, any discrepancy in the total bid price and that of the summation of Schedule price (price indicated in a Schedule indicating the total of that schedule), the total bid price shall be corrected to reflect the actual summation of the Schedule prices.
We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
We further understand that notwithstanding 3.0 above, in case of award on us, you shall also bear and pay/reimburse to us, GST applicable on supplies by us to you, imposed on the Plant & Equipment including Mandatory Spare Parts to be incorporated into the Facilities including Type Test charges for Type test to be conducted specified in Schedule No. 1, Installation Services specified in Schedule No. 3 and Charges for Training to be imparted specified in Schedule No. 4 of the Price Schedule in this Second Envelope by the Indian Laws.
We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
# (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Designation :
Description of Items
Description of Items
Description of Items
Bid Form 2nd Envelope
765kV GIS Extension Substation Package SS158 for (a) Extn. of 765/400kV Sasaram (POWERGRID) S/S associated with ERES-51: Diameter completion at Sasaram (POWERGRID) S/s and (b) Extn. of 220kV Nalagarh (POWERGRID) S/S associated with Implementation of 2 nos. 220kV line bays (GIS) at 400/220kV Nalagarh (PG) S/s for the termination of 220kV D/c line from 220/132kV Kunihar S/s to Nalagarh S/s
Price Schedules
In line with the requirements of the Bidding documents, we enclose herewith the following Price Schedules, duly filled - in as per your proforma:
Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges.
Local Transportation, In-transit Insurance, loading and unloading
Installation Charges.
Training charges for training to be imparted.
Taxes and Duties not included in Schedule 1
Grand Summary [Schedule 1to 5]
Break-up of Type Test Charges for Type Tests to be conducted
We are aware that the Price Schedules do not generally give a full description of the Work to be performed under each item and we shall be deemed to have read the Technical Specifications and other sections of the Bidding Documents and Drawings to ascertain the full scope of Work included in each item while filling-in the rates and prices. We agree that the entered rates and prices shall be deemed to include for the full scope as aforesaid, including overheads and profit.
We declare that as specified in Clause 11.5, Section –II:ITB, Vol.-I of the Bidding Documents, prices quoted by us in the Price Schedules in Second Envelope shall be on ‘Firm’ basis during the entire currency of contract and shall not be subject to price variation, what-so-ever during contract execution.
We understand that in the price schedules, where there are errors between the total of the amounts given under the column for the price Breakdown and the amount given under the Total Price, the former shall prevail and the latter will be corrected accordingly. We further understand that where there are discrepancies between amounts stated in figures and amounts stated in words, the amount stated in words shall prevail. Similarly, any discrepancy in the total bid price and that of the summation of Schedule price (price indicated in a Schedule indicating the total of that schedule), the total bid price shall be corrected to reflect the actual summation of the Schedule prices.
We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
We further understand that notwithstanding 3.0 above, in case of award on us, you shall also bear and pay/reimburse to us, GST applicable on supplies by us to you, imposed on the Plant & Equipment including Mandatory Spare Parts to be incorporated into the Facilities including Type Test charges for Type test to be conducted specified in Schedule No. 1, Installation Services specified in Schedule No. 3 and Charges for Training to be imparted specified in Schedule No. 4 of the Price Schedule in this Second Envelope by the Indian Laws.
We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
# (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Designation :
#VALUE!
Price Component
TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges
TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services.
TOTAL SCHEDULE NO.3: Installation Charges
TOTAL SCHEDULE NO.4: Training Charges
TOTAL BID PRICE: (Excluding Taxes & Duties)
DISCOUNT
NET BID PRICE (Excluding Taxes & Duties)
TAXES & DUTIES PAYABLE ADDITIONALLY
TOTAL BID PRICE (INCLUDING TAXES & DUTIES)
TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above]
Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty
Entry Tax/ Octroi
Others
With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
Ex-Works Price of Direct Supplies (after discount, if any)
Excise Duty, as applicable on (a) above at the rate :
Amount on which Sales Tax is applicable
CST, as applicable on (a) + ED (b) above at the rate :
VAT, as applicable on (a) + ED (b) above at the rate :
Others [……………………………………………]
Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others)
Entry Tax, as applicable on (e) above at the rate :
Statement of Quoted / Corrected Prices
Spec No: CC/NT/W-GIS/DOM/A02/26/13152
Price Component
TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges
TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services.
TOTAL SCHEDULE NO.3: Installation Charges
TOTAL SCHEDULE NO.4: Training Charges
TOTAL BID PRICE: (Excluding Taxes & Duties)
DISCOUNT
NET BID PRICE (Excluding Taxes & Duties)
TAXES & DUTIES PAYABLE ADDITIONALLY
TOTAL BID PRICE (INCLUDING TAXES & DUTIES)
TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above]
Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty
CST /VAT
Entry Tax / Octroi
Others
Bidder has offered following discount(s)
With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
Ex-Works Price of Direct Supplies (after discount, if any)
Excise Duty @ 10.3% of (a) above
CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above
Others
Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others)
Entry Tax @ 1% of (e) above
Statement of Quoted / Corrected Prices
Three
Seven
Eight
Eleven
Twelve
Thirteen
Fourteen
Fifteen
Sixteen
Seventeen
Eighteen
Nineteen
Twenty
Twenty One
Twenty Two
Twenty Three
Twenty Four
Twenty Five
Twenty Six
Twenty Seven
Twenty Eight
Twenty Nine
Thirty
Thirty One
Thirty Two
Thirty Three
Thirty Four
Thirty Five
Thirty Six
Thirty Seven
Thirty Eight
Thirty Nine
Forty
Forty One
Forty Two
Forty Three
Forty Four
Forty Five
Forty Six
Forty Seven
Forty Eight
Forty Nine
Fifty
Fifty One
Fifty Two
Fifty Three
Fifty Four
Fifty Five
Fifty Six
Fifty Seven
Fifty Eight
Fifty Nine
Sixty
Sixty One
Sixty Two
Sixty Three
Sixty Four
Sixty Five
Sixty Six
Sixty Seven
Sixty Eight
Sixty Nine
Seventy
Seventy One
Seventy Two
Seventy Three
Seventy Four
Seventy Five
Seventy Six
Seventy Seven
Seventy Eight
Seventy Nine
Eighty
Eighty One
Eighty Two
Eighty Three
Eighty Four
Eighty Five
Eighty Six
Eighty Seven
Eighty Eight
Eighty Nine
Ninety
Ninety One
Ninety Two
Ninety Three
Ninety Four
Ninety Five
Ninety Six
Ninety Seven
Ninety Eight
Ninety Nine
One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
3.0_COMBINED LAYOUT-765 kV & 400 kV.pdf
pdf • 5.09 MB
4.1_Layout,Plan & Section-400 kV (Rev-5) sh.01.pdf
pdf • 1.92 MB
4.2_Layout Plan & Section-400 kV(Rev-5) sh-02.pdf
pdf • 1.21 MB
5.0_SAS Architecture.pdf
pdf • 0.46 MB
3_ROAD CULVERT.pdf
pdf • 1.50 MB
4_CABLE TRENCH & CROSSING DETAILS.pdf
pdf • 0.63 MB
5_Standard 765 kV GIS Building Arch Drawing R0 BW.pdf
pdf • 0.79 MB
1.0_20260821_SLD Sasaram.pdf
pdf • 0.34 MB
2.0_20260821_GA Sasaram.pdf
pdf • 3.62 MB
4.0 TR202308-1002103-SS1907-SAS-ARCH DRG_0 (2).pdf
pdf • 2.15 MB
1_DETAILS OF CONCRETE ROAD(RIGID PAVEMENT) WITH PCC SHOULDER..pdf
pdf • 1.76 MB
2_DRAIN_RCC_SECTIONS.pdf
pdf • 4.45 MB
2_DRAIN_RCC_SECTIONS_1.pdf
pdf • 4.45 MB
4_CABLE TRENCH & CROSSING DETAILS_1.pdf
pdf • 0.63 MB
1.0_SLD NALAGARH.pdf
pdf • 0.39 MB
2.0_GA NALAGARH.pdf
pdf • 0.68 MB
3.0 TR202308-1002103-SS1907-EARTHING LAYOUT SWRD_3.pdf
pdf • 3.04 MB
20.0 TS-Telecomm System-Rev 06-Pat-2.pdf
pdf • 5.56 MB
1_DETAILS OF CONCRETE ROAD(RIGID PAVEMENT) WITH PCC SHOULDER._1.pdf
pdf • 1.76 MB
20.0 TS-Telecomm System-Rev 06-Part-1.pdf
pdf • 9.19 MB
REV_03_GE_400kV_26_12_2023.xlsx
xlsx • 1.99 MB
REV 03_ABB_12122023_Final.xlsx
xlsx • 0.56 MB
220kV_BC.xlsx
xlsx • 0.02 MB
220kV_ICT_INCOMER.xlsx
xlsx • 0.02 MB
220kV_LINE.xlsx
xlsx • 0.07 MB
220kV_MCU.xlsx
xlsx • 0.02 MB
220kV_TBC.xlsx
xlsx • 0.02 MB
400kV_BR.xlsx
xlsx • 0.04 MB
400kV_ICT.xlsx
xlsx • 0.07 MB
400kV_LINE REACTOR.xlsx
xlsx • 0.04 MB
400kV_LINE.xlsx
xlsx • 0.07 MB
400kV_MCU.xlsx
xlsx • 0.03 MB
400kV_TIE.xlsx
xlsx • 0.03 MB
765kV_BUS REACTOR.xlsx
xlsx • 0.05 MB
765kV_ICT.xlsx
xlsx • 0.08 MB
765kV_LINE REACTOR.xlsx
xlsx • 0.04 MB
765kV_LINE.xlsx
xlsx • 0.07 MB
765kV_MCU.xlsx
xlsx • 0.03 MB
765kV_TIE.xlsx
xlsx • 0.03 MB
Referece_Siemens_Aux system.xlsx
xlsx • 0.02 MB
Trip logic Diagram & CT VT connection.pdf
pdf • 0.62 MB
Section-Sub-station Automation_Appendix-II_Standard SAS FAT format & procedure.pdf
pdf • 1.23 MB
Section-Sub-station Automation_Appendix-III_Standard CRP FAT format & procedure.pdf
pdf • 0.66 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Sub-station Automation_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
18.0 PLCC R5.pdf
pdf • 0.06 MB
19.0 PMU TS Rev 01.pdf
pdf • 0.45 MB
Annexure-1-Hirchman Ethernet Network switch Configuration.pptx
pptx • 1.51 MB
Annexure-2-Magnum Ethernet Network switch Configuration.pptx
pptx • 0.69 MB
Annexure-3-Ruggedcom Ethernet Network switch Configuration.pptx
pptx • 0.41 MB
Configuration for Root & Non-Root Ethernet Switch.docx
docx • 0.06 MB
FAT-SAT procedure_Router firemwall_Rev_0.pdf
pdf • 0.30 MB
AC SS datalist.xlsx
xlsx • 0.66 MB
FSC Datalist Rev1.xlsx
xlsx • 0.04 MB
NTAMC signal list -HVDC rev03.xlsx
xlsx • 0.02 MB
STATCOM NTAMC Signal proposed list for TS.xlsx
xlsx • 0.02 MB
SVC Datalist-Rev1.xlsx
xlsx • 0.04 MB
01_PROT_TRIP_ONE & HALF_Rev 00_Page_01.pdf
pdf • 0.19 MB
01_PROT_TRIP_ONE & HALF_Rev 00_Page_02.pdf
pdf • 0.19 MB
02_PROT_TRIP_DM & DMT_Rev 00-Page 01.pdf
pdf • 0.19 MB
02_PROT_TRIP_DM & DMT_Rev 00-Page 02.pdf
pdf • 0.18 MB
03_PROT_TRIP_400_220_ICT_Rev 00-Page_01.pdf
pdf • 0.10 MB
03_PROT_TRIP_400_220_ICT_Rev 00-Page_02.pdf
pdf • 0.10 MB
03_PROT_TRIP_400_220_ICT_Rev 00-Page_03.pdf
pdf • 0.06 MB
04_PROT_TRIP_765_400_ICT_Rev 00-Page-01.pdf
pdf • 0.11 MB
04_PROT_TRIP_765_400_ICT_Rev 00-Page-02.pdf
pdf • 0.08 MB
04_PROT_TRIP_765_400_ICT_Rev 00-Page-03.pdf
pdf • 0.07 MB
05_PROT_TRIP_BUS REACTOR_Rev 00-Page-01.pdf
pdf • 0.08 MB
05_PROT_TRIP_BUS REACTOR_Rev 00-Page-02.pdf
pdf • 0.08 MB
05_PROT_TRIP_BUS REACTOR_Rev 00-Page-03.pdf
pdf • 0.06 MB
06_PROT_TRIP_NON SW LR_Rev 00-Page-01.pdf
pdf • 0.05 MB
06_PROT_TRIP_NON SW LR_Rev 00-Page-02.pdf
pdf • 0.08 MB
06_PROT_TRIP_NON SW LR_Rev 00-Page-03.pdf
pdf • 0.07 MB
07_PROT_TRIP_SW LR_Rev 00-Page-01.pdf
pdf • 0.06 MB
07_PROT_TRIP_SW LR_Rev 00-Page-02.pdf
pdf • 0.09 MB
07_PROT_TRIP_SW LR_Rev 00-Page-03.pdf
pdf • 0.06 MB
08_ SPARE SELECTION LOGIC_ICT.pdf
pdf • 0.13 MB
09_ SPARE SELECTION LOGIC_REACTOR.pdf
pdf • 0.12 MB
Referece_GE_Aux system.xlsx
xlsx • 0.02 MB
REV_03_GE_ 220kV_26_12_2023.xlsx
xlsx • 1.84 MB
REV_03_GE_ 765kV_26_12_2023.xlsx
xlsx • 1.45 MB
13.0 Section_Switchyard Erection_Rev.10.pdf
pdf • 4.45 MB
14.0 Structure Rev 7.pdf
pdf • 0.30 MB
15.0 Civil Works Rev 12 with corr slip-1.pdf
pdf • 1.75 MB
16.0 CRP Rev 09.pdf
pdf • 0.37 MB
01_CT_VT_Conn_ONE AND HALF_LINE_Rev00.pdf
pdf • 0.05 MB
02_CT_VT_Conn_DMT_LINE_Rev00.pdf
pdf • 0.04 MB
03_CT_VT_Conn_SERIES REACTOR_01_Rev00_PAGE_01.pdf
pdf • 0.05 MB
03_CT_VT_Conn_SERIES REACTOR_01_Rev00_PAGE_02.pdf
pdf • 0.03 MB
04_CT_VT_Conn_1Phase_LR_SW_01_Rev00_PAGE_01.pdf
pdf • 0.06 MB
04_CT_VT_Conn_1Phase_LR_SW_01_Rev00_PAGE_02.pdf
pdf • 0.07 MB
05_CT_VT_Conn_3Phase_LR_SW_01_Rev00_PAGE_01.pdf
pdf • 0.05 MB
05_CT_VT_Conn_3Phase_LR_SW_01_Rev00_PAGE_02.pdf
pdf • 0.04 MB
06_CT_VT_Conn_1Ph_NON_LR_SW_Rev00_PAGE_01.pdf
pdf • 0.06 MB
06_CT_VT_Conn_1Ph_NON_LR_SW_Rev00_PAGE_02.pdf
pdf • 0.06 MB
07_CT_VT_Conn_3Ph_NON_LR_SW_Rev00_PAGE_01.pdf
pdf • 0.06 MB
07_CT_VT_Conn_3Ph_NON_LR_SW_Rev00_PAGE_02.pdf
pdf • 0.04 MB
08_CT_VT_Conn_1Phase_ICT01_Rev00_PAGE_01.pdf
pdf • 0.05 MB
08_CT_VT_Conn_1Phase_ICT01_Rev00_PAGE_02.pdf
pdf • 0.07 MB
08_CT_VT_Conn_1Phase_ICT01_Rev00_PAGE_03.pdf
pdf • 0.05 MB
09_CT_VT_Conn_3Phase_ICT01_Rev00_PAGE_01.pdf
pdf • 0.05 MB
09_CT_VT_Conn_3Phase_ICT01_Rev00_PAGE_02.pdf
pdf • 0.05 MB
09_CT_VT_Conn_3Phase_ICT01_Rev00_PAGE_03.pdf
pdf • 0.03 MB
10_CT_VT_Conn_BR_1PHASE_Rev00_PAGE_01.pdf
pdf • 0.05 MB
10_CT_VT_Conn_BR_1PHASE_Rev00_PAGE_02.pdf
pdf • 0.06 MB
11_CT_VT_Conn_BR_3PHASE_Rev00_PAGE_01.pdf
pdf • 0.05 MB
11_CT_VT_Conn_BR_3PHASE_Rev00_PAGE_02.pdf
pdf • 0.03 MB
DR Channel Standardization Revision Edition_02.pdf
pdf • 1.15 MB
1.5 Annexure-V_TECHNICAL SPECIFICATION_Polymer BPI Rev_2.pdf
pdf • 0.23 MB
1.6 Annexure-VI_TS for Substation Design Software_v1.pdf
pdf • 0.36 MB
1.7 Annexure-S1 (Revised).pdf
pdf • 0.10 MB
02.0 Section_GTR_rev16.pdf
pdf • 3.36 MB
03.0 GIS Rev-5A.pdf
pdf • 1.95 MB
04.0 Section-Switchgear-CB_Rev12.pdf
pdf • 1.73 MB
05.0 Section-Switchgear-ISO_Rev13.pdf
pdf • 0.68 MB
06.0 Section-Switchgear-INST_rev12.pdf
pdf • 0.86 MB
07.0 Section-Switchgear-SA_Rev13.pdf
pdf • 0.87 MB
08.0 Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
09.0 Lighting Specification Rev.07.pdf
pdf • 4.29 MB
10.0 Fire Protection Rev 6.pdf
pdf • 1.97 MB
11.0 LT Switchgear R5.pdf
pdf • 0.47 MB
12.0 Air conditioning R4.pdf
pdf • 0.04 MB
1.3 Annexure-III Specific Requirement with Annexures_Rev 10.pdf
pdf • 9.19 MB
1.4 Annexure-IV_DESCRIPTION OF 420KV GIS BAY MODULES & EQUIPMENTS-SS158.pdf
pdf • 0.20 MB
1.0 Section_Project_SS158_v2.pdf
pdf • 0.62 MB
1.1 Annexure-I_List of Drawings.pdf
pdf • 0.18 MB
1.2 Annexure-II_Breakup Mandatory Spare.pdf
pdf • 0.22 MB
00_Attachment -3 (QR)_25-Sep-26 14-43-46.xlsx
xlsx • 0.20 MB
02_Attachment-8(a)_Manufacturer Authorization Form.docx
docx • 0.03 MB
03_Attachment-8(b).docx
docx • 0.03 MB
04_Attachment-20_KMP Declaration.docx
docx • 0.02 MB
05_Attachment_21_Affidavit for Self-Certification_PPP-MII_.docx
docx • 0.03 MB
06_Attachment-22_Compliance to the process related to the e-RA_.docx
docx • 0.02 MB
07_Attachment-23_Confirmation in regard to Design and Type Test.docx
docx • 0.02 MB
08_Attachment-24_Declaration regarding events encountered.docx
docx • 0.03 MB
09_Attachment-25_Affidavit reg DMI&SP policy.docx
docx • 0.03 MB
10_Attachment 26_Certificate by bidder.docx
docx • 0.02 MB
11_Attachment-27_Bid Securing Declaration.docx
docx • 0.02 MB
12_Attachment-28_Undertaking-Original_Hard-Copy.docx
docx • 0.02 MB
13_Attachment-29_Decl by the bidder for Code of Integrity for Public procurement.docx
docx • 0.02 MB
14_Attachment-30_Declaration-Supplier Code of Conduct.docx
docx • 0.02 MB
15_Legends for Units.pdf
pdf • 0.03 MB
First_Envelope_and_Bid_Forms.xlsx
xlsx • 1.48 MB
Price_Schedule_SS158.xlsx
xlsx • 1.93 MB
01_Main Index_Vol-I.doc
doc • 0.02 MB
02-Section - I IFB SSTE.docx
docx • 0.04 MB
03_ Section - II ITB SSTE S&I DCB-PRANIT_Vol-I.docx
docx • 0.11 MB
04- Section-III-BDS.docx
docx • 0.10 MB
05-Annexure-A to BDS.docx
docx • 0.03 MB
06-Annexure-B to BDS.docx
docx • 0.02 MB
07-Annexure-C (BDS) - PRANIT.docx
docx • 0.03 MB
08-Annexure-C (BDS) - MJunction.docx
docx • 0.03 MB
09-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
10- Section-V-SCC (GIS).docx
docx • 0.10 MB
11_Appendix-I to SCC.pdf
pdf • 0.30 MB
12_Appendix-II to SCC.pdf
pdf • 0.31 MB
13_Appendix-III to SCC.pdf
pdf • 0.62 MB
14-Section - VI Forms and Proceedures.docx
docx • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .