| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-Finance | L1 | Accepted-Finance Lowest quoted. | |
| 2 | L2₹1.8 L+₹7,307.76 (4.15%)Rejected-Finance | L2 | Rejected-Finance Quoted higher than L1. |
Tender Value
₹1.8 L
EMD Value
₹3,600
Closing Date
5 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Registrar, C.U.
Office of the Registrar Department, Darbhanga Building, 87/1 College Street Kolkata- 700073, University of Calcutta.
Roof Water Proofing of the Roof of PRO Vice Chancellors (AA) office at Darbhanga Building College Street Campus, University of Calcutta.
2026_CU_1043468_1
R/34/CT-tender/26-27 (2nd call)
Open Tender
CIVIL WORKS
Percentage
30 days
College Street Campus, C.U.
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3,600
26 Nov 2026
28 Sept 2026
7 Oct 2026
28 Sept 2026
5 Oct 2026
28 Sept 2026
180 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out old damaged tarfelt from the roof, parapet etc.
preparing the roof surfaces by removing all spoils, blisters,
moss etc. from the working site and disposal of the same
beyond the compound and cleaning the site in all respect as
per direction of Engineer-in-ChargeAll floor | 79 | Sqm | 14.16 | ₹1,118.64 |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the
surface for plaster including disposal of rubbish to the dumping ground
within 50 metres lead | 79 | CuM | 54.65 | ₹4,317.35 |
| 3 | Cutting chase upto 125 x 150 mm. and subsequent
mending of damages. | 32 | M. | 109.74 | ₹3,511.68 |
| 4 | Providing, mixing and applying bonding coat of approved adhesive on
chipped portion of RCC as per specifications and direction of Engineer-
In-charge complete in all respectSBR Polymer (@10% of cement weight) modified
cementitious bond coat @ 2.2 kg cement per sqm of surface
area mixed with specified proportion of approved polymer | 55 | Sqm | 141.2 | ₹7,766 |
| 5 | Providing, mixing and applying SBR polymer (of approved make @
minimum 2% by wt. of cement used) modified plain/reinforced cement
concrete for structural members having minimum characteristic
compressive strength [with ordinary portland cement, coarse sand and
graded stone aggregate of 10 mm maximum size in proportion as per
design criteria] with specified average thickness50 mm thick in Grade M25 with cement content not less
than 330 kg per cum | 55 | Sqm | 569.15 | ₹31,303.25 |
| 6 | Providing, mixing and applying SBR polymer (of approved make) modified
Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with
polymer minimum 2% by wt. of cement used) as per specifications and
directions of Engineer-in-charge 25 mm average thickness in 2 layers. | 79 | each | 587.35 | ₹46,400.65 |
| 7 | Providing and laying APP (Atactic Polypropylene Polymer) modified
prefabricated five layer 3 mm thick water proofing membrane, black
finished reinforced with non-woven polyester matt consisting of a coat
of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same
membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity
70-160 cps. Over the primer coat the layer of membrane shall be laid
using Butane Torch and sealing all joints etc, and preparing the surface
complete. The vital physical and chemical parameters of the membrane3 mm thick
shall be as under : Joint strength in longitudinal and transverse direction
at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not less than 150°C.
Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D
- 5147. The laying of membrane shall be got done through the authorised
applicator of the manufacturer of membrane | 79 | cum | 560.95 | ₹44,315.05 |
| 8 | Painting wood work with Deluxe Multi Surface Paint of required
shade. Two or more coat applied @ 0.90 ltr/10 sqm over an
under coat of primer applied @0.75 ltr/10 sqm of approved
brand and manufacture | 35.04 | Sqm | 176.25 | ₹6,175.8 |
| 9 | Manpower for repairing the external windows and making of scaffolding toilets Mistry | 7 | Sqm | 897 | ₹6,279 |
| 10 | Helper (Technician | 6 | Sqm | 736 | ₹4,416 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
BOQ_2560294.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .