Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC Firm has fulfilled all criteria as per NIT and Price of this firm is less than L2 and L3 | |
| 2 | L2₹7.4 L+₹3,061.92 (0.42%)Rejected-Finance | L2 | Rejected-Finance Price of this Contractor is more than L1 contractor. | |
| 3 | L3₹7.4 L+₹3,921.20 (0.53%)Rejected-Finance | L3 | Rejected-Finance Price of this Contractor is more than L1 and L2 contractors. | |
| 4 | Rejected-Technical 41 RAGHUBANSH MARKET RAGHUBANSH MARKET EXHIBITION ROAD EXHIBITION ROAD PATNA BIHAR 800001 | PATNA | BIHAR | 800001 | - | Rejected-Technical Firm has not submitted any documents / Tender Cost etc in Offlinne / Tender BOx. | |
| 5 | Rejected-Technical | - | Rejected-Technical Firm registration doct not found and EMD and Tender Cost not deposited in Offline/Tender Box |
Tender Value
Refer Docs
EMD Value
₹14,814
Closing Date
18 Feb 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commandant 159 Bn, CRPF, Gaya (Bihar)
HQ 159 Bn CRPF, Jail Complex, Gaya (Bihar)
Construction of barrack at G/159 Bn, CRPF, Lutua, Gaya (Bihar)
2021_CRPF_612292_1
L.VIII-1/2019-20-Work-04-G/159 Bldg (SRE)
Open Tender
Construction Works
Works
60 days
G/159 Bn, CRPF, Lutua, Gaya (Bihar)
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Commandant 159 Bn CRPF, Gaya (Bihar)
₹14,814
Yes
8 Mar 2021
27 Jan 2021
19 Feb 2021
27 Jan 2021
18 Feb 2021
27 Jan 2021
180 days
DETAILS OF WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 1.1) i) For Room Wall Length= 2(4.87+0.23) + 2(4.87+.023) = 20.4m - 6m (6 nos Column)=14.4m (ii) For Verandah Length=(4.87+.23)+2(1.82+0.23)=9.2m (iii) For Column Base (6Nos X 1=6m)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 2.1) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) i)For Room Wall iiii) For Verandah iii)For Column Base (06Nos xo1=6m)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 3.1) Cement mortar 1:6 (1 cement : 6 coarse sand) i)For Room Wall (UP TO GL) ii) For Verandah (UP TO GL) iv)For Room Wall (GL TO PL) vi) For Verandah (GL TO PL)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III): 4 graded stone aggregate 20mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 5.1) Cement mortar 1:6 (1 cement : 6 coarse sand) i)For Room Wall ii) 04 Nos Shelves Partation Wall Size (3'x4.5"x5'),Total Length of Wall=4(0.91)=3.6m Deduction for Door, Length = 1.21= 1.21 m Deduction for 03 No windows, Length=3(1.21)=3.63m Deduction For Tie beam
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 6.1) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) For Foundation of Column (Length=6x0.6=3.6m) For Pedestral Length=0.45x6=2.7m
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). For Column 6x.23=1.38m Shelves Size of Slab (16'X3'X4'') Tie Beam
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 8.1) Thermo-Mechanically Treated bars of grade Fe-500D or more. {Total Volume of RCC Work = (2.89+2.18=5.07)}
Centering and shuttering including strutting, propping etc. and removal of form for 9.1) Foundations, footings, bases of columns, etc. for mass concrete up to pl work For Foundation of Column (One column Four side) For Pedestral
Centering and shuttering including strutting, propping etc. and removal of form for Super-structure Work 10.1) Columns, Pillars, Piers, Abutments, Posts and Struts (0.23x4=0.92m FOR 6 Column=6x0.92=5.52m) Tie Beam
12 mm cement plaster of mix : 11.1) 1:6 (1 cement: 6 fine sand) Internal Room Wall Surfac External Room Wall Surfac Shelves wall Deduction For Door Opening and 02 (outer+internal surface )Length = 1.21 = 2x1.21 = 2.42 m Deduction For 03 No Windows Opening and 02 (Outer+Internal surface) Length=3(1.21)=3.63x2=7.26m
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 12.1) 25 mm thick For inside of Barrack For Verandah
White washing with lime to give an even shade 13.1) New work (three or more coats),Length=19.51+20.43=39.94m
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 13A.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) For Room Floor For Verandah Floor
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 14.1) For Gap fiilling of foundation For Plinth fiilling :- i) Room ii) Verandah
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 15.1) Hot finished welded type tubes (Including 2'' and 4 post for verandah)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 17.1) 0.63 mm thick with zinc coating not less than 275 gm/ m² For Room For Verandah
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 18.1) 250x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 19.1) 125 mm
Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete 20.1) 300x20x6 mm
Providing and fixing aluminium work for doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 21.1) Power coated aluminum
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 22.1) 30 mm thick shutters
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 23.1) 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.
RCC Framed Structure 41.69 Sqm 30.1) Electrical external service Connection
Internal Electric Installation
Power wiring and Plug
Lighting Conductor
AGARWAL TRADING
CREATIVE CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .