Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹39.9 LAdmitted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | -37.53% | ₹39.9 L | L1 | Admitted-Finance |
| 2 | L2₹43.2 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | SHAHDARA | DELHI | 110032 | -32.50% | ₹43.2 L | L2 | Admitted-Finance |
| 3 | L3₹43.4 LAdmitted-Finance | -32.17% | ₹43.4 L | L3 | Admitted-Finance |
| 4 | L4₹48.0 LAdmitted-Finance GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | -24.88% | ₹48.0 L | L4 | Admitted-Finance |
| 5 | L5₹56.3 LAdmitted-Finance | -12.00% | ₹56.3 L | L5 | Admitted-Finance |
Tender Value
₹64.0 L
EMD Value
₹1.3 L
Closing Date
24 Feb 2026, 3:00 pmClosed
Executive Engineer (Elect.)
EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park
Sub Head- Operation and Maintenance of E.I, Pumps, DG Set and Electrical Works.
2026_PWD_287145_1
101/EE(E)/PWD NES ED/2025-26
Open Tender
Electrical Works
365 days
Under Sub Div-2511
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.3 L
Yes
25 Feb 2026
17 Feb 2026
24 Feb 2026
17 Feb 2026
24 Feb 2026
17 Feb 2026
Sub Head-I (Opt. & Maint) Providing Services of Electrical staff for attending day to day complaint related to all electrical installation in SDM Court & Various VREC Center Seelampur, Mustafabad, Ghonda, Balbir Nagar, Karawal Nagar in general shift on all working day excluding Sunday & holiday. Wireman cum operator -2 Nos. Khallasi - 02 Nos. (9 AM to 5 PM)
Providing Services of DG Set Operator for attending day to day complaint DG Set and Pump set in SDM Court in general shift on all working day excluding Sunday & holiday. DG Set Operator -1 Nos. (9 AM to 5 PM)
Providing Services of Wireman for attending day to day complaint related to all electrical installation in Dr. Bhim Rao Ambedkar College campus and residential campus on all working day including Sunday & holiday. Wireman cum operator -1 Nos. (9 AM to 5 PM)
Providing Services of Sub Station Operator cum DG Set Operator for attending day to day complaint DG Set and Pump set in Dr. Bhim Rao Ambedkar College campus and residential campus in three shift on all working day including Sunday & holiday. Sub Station cum DG Set Operator -3 Nos. (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM)
Providing Services of Khallasi for helping wireman cum operator during the electrical installation complaint & operation of pump sets, DG sets in on all working day including Sunday & holiday. Khallasi -1 Nos. (9 AM to 5 PM)
Sub Head- (E.I. Works)
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. "GROUP C"
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
6 way , Double door
12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
8 way (4 + 24), Double door
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 53 DELHI SCHEDULE OF RATES (E&M)-2025 as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
150 watt Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).
100 watt Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt).
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter type - Cooling only 2.0 TR with 5 Star BEE Rating
Providing and fixing pole box of size 250mm X 200mm X 105mm with side openable hinged cover complete with two strip aluminium bus-bar of 100 amps capacity mounted on DMC bus support and 1 no. of SPMCB of 6 amps 'C' series capacity with din rail on the existing street light pole with the help of two nos. MS clamps of suitable size, including making hole to insert the cable and dismantling the worn out MS box etc. complete as required.
Supplying, Installation Testing and Commissioning of 35 Watt LED post top lanterns fittings suitable for operation 220 volt 50 Hz single phase AC supply i/c connection, testing etc as reqd.
Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1, suitable clamp in following manners.
3.5 x 35 sq. mm (On Surface) (Clamped with 1 mm thick saddle)
3.5 x 50 sq. mm (On Surface) (Clamped with 25 x 3 mm MS flat clamp)
3.5 x 95 sq. mm (In Pipe)
Fabricating, Supplying & Fixing wire mesh protection frame work made out of 40 mm x 6 mm thick angle & "T" strengthened with intermediate members of MS flat iron of size 30 mm x 5 mm thick welded at a distance of 30 cm horizontally & vertically and duly welded with wire mesh of size 75 mm x 25 mm made with 6 SWG wire mash of size 75 mm x 25 mm made with 6 SWG wire on all sides and top i/c providing and fixing of double door gate with double locking arrangement ( Two Nos. sliding bolts and One No go down lock) having 0.5 mtr. long legs of 40 mm x 40 mm x 6 mm thick angle iron, duly grouted in cement concrete foundation ration 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate), up to suitable depth painting with one coat of red oxide & Two coats of synthetic enamel paint of approval colour, shade with fabric sheet etc. complete as reqd.
Supplying of Following Item:-
Supplying of 36 to 40 watt surface/recess mounted LED Luminaries of size 1200 mm (Length) x 300 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 100 luman per watt. and colour temperature of 5700-6500 K, CRI >80 with APFC driver having power factor > 0.90, THD <20% and efficiency > 85% driver should be IC Compliant, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve etc. etc. complete as required.
Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 Amp, 16 KA, TPMCCB
250 A,50KA,FPMCCB
Supplying of following 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete etc. as required.
Single pole
Double pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete etc. as required
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete etc. as required.
Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Power Coated die cast/extended aluminium Body thickness ≥ 1.20 mm)
36 watt LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)
Supplying of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. (Brush Less Direct Current (BLDC) Fan without Remote)
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Power Coated die cast/extended aluminium Body thickness ≥ 1.20 mm)
18- 22 Watt (LED Batten light (System lumen efficacy ≥120 <135 lm/Watt))
Supplying of 6.2 Mtr (20.5 Feet) Portable & Compact Aluminium Telescopic Ladder For Multipurpose Use with following specification Brand: Welbuilt Weight : 18 kg (not less than), Load Capacity : 150 kg or above, Number of Steps : 15 or above, Material: Aluminium Product Dimensions : 49W x 620H Centimeters, Maximum Height : 6.2 Meter ( 20.5 Feet) i/c connection, testing etc. as reqd.
Supplying of 300 mm dia 1400 RPM Exhaust fan M.S type suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC single core cable etc. as reqd.
Supplying of Oil Filled Room Heater with 11fins, Power Consumption up to 2400 watt, Heating Modes: 3, Over Heat Protection: Yes, Efficient & Fast Heating etc. as reqd.
Supplying of 2.5 MFD Capacitor for ceiling fans etc. as reqd.
Supplying of 15/16 Amp 3 Pin Power Top Plug etc. as reqd. at site.
Supplying and Fixing of 21 Watt or above Air Purifier, HEPA Nano Protect + Activated Carbon Filter, CADR 250m³/h for 65m2 and noise level 20.5 db or below Quiet, Smart and Energy Efficient etc. complete etc. as reqd.
Credit for old dismantle materials
Assorted Wire
Assorted Cable
Assorted Switch and Socket
Assorted LED Fittings/Post Top Fittings
Assorted Fans
Assorted LED Flood Light Fittings
Assorted MCCB
Assorted MCB,DB, TPN etc.
Assorted Top/Capacitor
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.85 MB
BOQ_380393.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid